Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “eem”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Exposure of chick embryos to cadmium changes the extra-embryonic vascular branching pattern and alters expression of VEGF-A and VEGF-R2

Cadmium (Cd) has several industrial applications, and is found in tobacco products, a notable source of human exposure. Vascular endothelial cells are key targets of Cd toxicity. Here, we aim to quantify the alteration to vascular branching pattern following Cd exposure in the chick extra-embryonic membrane (EEM) using fractal analysis, and explore molecular cues to angiogenesis such as VEGF-A and VEGF-R2 expression following Cd treatment. Chicken embryos were incubated for 60 h to Hamburger–Hamilton developmental stage 16–17, then explanted and treated with 50 μL of 50 μmol cadmium acetate (CdAc) or an equivalent volume of equimolar sodium acetate (NaAc). Images of embryos and their area vasculosa (AV) were captured and analyzed at 4 different time points (4, 8, 24 and 48 h) following treatment. Vascular branching in the AV was quantified using its fractal dimension (D{sub f}), estimated using a box counting method. Gallinaceous VEGF ELISA was used to measure the VEGF-A concentration in the EEM following treatment, with determination of the relative expression of VEGF-A and VEGF-R2 using quantitative real-time RT-PCR. Vascular branching increased monotonically in the control group at all time points. The anti-angiogenic effect of Cd exposure on the AV was reflected by a significant reduction in D{sub f} when compared with controls. D{sub f} was more markedly reduced in cultures with abnormal embryos. The expression of VEGF-A protein, and VEGF-A and VEGF-R2 mRNA were reduced in Cd-exposed EEMs. Both molecules contribute to growth, vessel sprouting and branching processes, which supports our findings using fractal analysis. - Highlights: • The chick area vasculosa was undersized in embryos exposed to 50 μM cadmium acetate. • Fractal dimension was reduced in the AV after Cd exposure, indicating decreased branching. • VEGF-A protein was decreased in Cd-treated extraembryonic membranes. • VEGF-A and VEGF-R2 mRNA was decreased in Cd-treated extraembryonic membranes. • Vascular effects were more notable in malformed embryo's AVs after Cd exposure.

60 APPLIED LIFE SCIENCES↗

Influence of Carbon-Nitride Dot-Emitting Species and Evolution on Fluorescence-Based Sensing and Differentiation

Carbon dots have attracted widespread interest for sensing applications based on their low cost, ease of synthesis, and robust optical properties. We investigate structure–function evolution on multiemitter fluorescence patterns for model carbon-nitride dots (CNDs) and their implications on trace-level sensing. Hydrothermally synthesized CNDs with different reaction times were used to determine how specific functionalities and their corresponding fluorescence signatures respond upon the addition of trace-level analytes. Archetype explosives molecules were chosen as a testbed due to similarities in substituent groups or inductive properties (i.e., electron withdrawing), and solution-based assays were performed using ratiometric fluorescence excitation–emission mapping (EEM). Analyte-specific quenching and enhancement responses were observed in EEM landscapes that varied with the CND reaction time. We then used self-organizing map models to examine EEM feature clustering with specific analytes. Finally, the results reveal that interactions between carbon-nitride frameworks and molecular-like species dictate response characteristics that may be harnessed to tailor sensor development for specific applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Injection mechanisms in a III -nitride light-emitting diode as seen by self-emissive electron microscopy

Here, we report on the investigation of an electrically biased high efficiency green III-nitride light-emitting diode (LED) by electron emission microscopy (EEM) using a low-energy electron microscope (LEEM). The surface of the LED was activated to negative electron affinity via deposition of a submonolayer of Cs. With the illumination column of the LEEM turned off, upon electrical injection of the LED, we directly image the hot electrons generated by eeh Auger-Meitner nonradiative processes that diffuse through the top p-Ga N layer and emit out the surface of the biased LED. By determining the source of emitted electrons using complementary electron emission spectroscopy measurements, EEM allows us to effectively map the carrier density within the LED. Using EEM, we observed nonelectron emitting regions with a density of approximately 3 × 10 8 cm -2 , identified as V-shaped defects (V-defects). This is confirmed through the corresponding dark spots of panchromatic cathodoluminescence measurements of the same sample and by plan-view transmission electron microscopy. The absence of electron emission at the sidewall of the V-defects can be attributed to several factors, including reduced carrier density in the sidewall quantum wells due to carriers traveling fast through the semipolar sidewalls before being injected into the planar quantum wells, the reduced population of hot electrons surviving diffusion through the thicker p-GaN filling in the V-defect before emission onto vacuum, and a smaller Auger-Meitner coefficient for the low In content semipolar sidewall quantum wells. The stronger electron emission observed at the ridges of most V-defects compared to the planar quantum well regions indicates larger local injected carrier densities, confirming that V-defect sidewalls allow for strong lateral carrier injection when compared to the weaker vertical injection away from the V-defect as evidenced by the weaker electron emission intensity away from the V-defects.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Evaluation of Electromechanical Systems Dynamically Emulating a Candidate Hydrokinetic Turbine

The use of controllable motor-generator sets to emulate the dynamics of a hydrokinetic turbine is evaluated as an alternative to field testing a prototype. The emulator control dynamic equations are presented, methods for scaling turbine parameters are examined, and experimental results are presented from three electromechanical emulation machines (EEMs) programmed to emulate the same vertical-axis fixed-pitch turbine. Although hardware platforms and control implementations varied, results show that each EEM is successful in emulating the turbine model, thus demonstrating the general feasibility of the approach. However, performance of motor control under torque command, current command or speed command differed. In one of the EEMs evaluated, the power take off controller tracks the maximum power-point of the turbine in response to turbulence. Utilizing realistic inflow conditions and control laws, the emulator dynamic speed response is shown to agree well at low frequencies with numerical simulation but to deviate at high frequencies.

13 HYDRO ENERGY↗

FY2020 Energy Efficient Mobility Systems Annual Progress Report

EEMS Program activities during FY 2020 focused on analytical research and large-scale modeling and simulation to understand the impacts that new mobility technologies and services will have at the vehicle-, traveler-, and overall transportation system-level. This research included the development of a multi-fidelity, end-to-end transportation system models and tools to evaluate the complex interactions among the various actors within the mobility landscape, analysis of empirical data to characterize which solutions may provide the largest benefits, and development of new control systems and algorithms that use vehicle connectivity and automation to improve the performance and efficiency of individual vehicles as well as the overall traffic system. This document presents a brief overview of the EEMS Program and documents progress and results from projects within each of the EEMS activity areas. The Computational Modeling and Simulation key activity area summarizes work within the sub-areas of (1) the SMART (Systems and Modeling for Accelerated Research in Transportation) Mobility Lab Consortium, (2) Artificial Intelligence, High-Performance Computing, and Data Analytics, and (3) Core Simulation and Evaluation Tools. Additionally, the program’s advanced R&D projects are summarized within (4) the Connectivity and Automation Technology key activity area. Each of the individual progress reports provide a project overview and highlights of the technical results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exploring Decarbonization and Clean Energy Pathways for Disadvantaged Communities in California

California has a state-wide goal of carbon neutrality by 2045. Decarbonization for disadvantaged communities (DACs) poses extra challenges due to financial, informational, language, and other barriers. This paper presents the methodology, results, and analysis of energy efficiency measures (EEMs) to save energy, reduce CO 2 emission, and promote clean energy access at the district scale for two DACs in Fresno, California. The methods are broadly applicable to other neighborhoods across the U.S. 22 EEMs were identified and modelled for all residential buildings in the two DACs both individually and as packages. Results show that for energy and CO 2 reduction purposes, the top performing EEM package can decrease energy use and CO 2 emissions by an average of 60%. For electrification, heat pump water heaters are a viable solution, coupled with air source or mini-split heat pumps. Replacing gasoline vehicles with electric vehicles is another important measure in electrification and reducing GHG emissions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy Efficient Mobility Systems (2022 Annual Progress Report)

DOE conducts research to understand how the changing mobility landscape will affect transportation energy consumption and identifies opportunities to create more efficient, affordable, reliable, accessible, equitable, and secure transportation options that enhance mobility for individuals and businesses. Within EERE, the EEMS Program is responsible for this research portfolio. This APR describes work that the EEMS Program conducted during FY 2022 in support of the EEMS Program goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficient Mobility Systems (2023 Annual Progress Report)

This document summarizes the progress of VTO Energy Efficient Mobility Systems projects supported during the fiscal year 2023. DOE conducts research to understand how the changing mobility landscape will affect transportation energy consumption and identifies opportunities to create more efficient, affordable, reliable, accessible, equitable, and secure transportation options that enhance mobility for individuals and businesses. Within EERE, the EEMS Program is responsible for this research portfolio. This APR describes work that the EEMS Program conducted during FY 2023 in support of the EEMS Program goals.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Savings Results from Small Commercial Building Retrofits in the US

Small commercial buildings, or those comprising less than 50,000 square feet of floor area, represent 94% of U.S commercial buildings by count and consume approximately 8% of the nation’s primary energy; as such, they represent a largely unexploited opportunity for energy savings. Small commercial buildings also represent a large economic market—the National Institute of Building Sciences (NIBS) estimated the small commercial retrofit market at USD 35.6 billion. Despite the prominence of small commercial buildings and the economic opportunity for energy retrofits, many energy efficiency programs focus on large commercial buildings, and create efficiency solutions that do not meet the needs of the small commercial market. This paper presents an analysis of 34 small commercial case study projects that implemented energy efficiency retrofits. This paper contributes to the existing building retrofit body of knowledge in the following ways: (1) it identifies the decision criteria used by small commercial building stakeholders that decided to complete an energy retrofit; (2) it identifies the most commonly implemented efficiency measures in small commercial buildings, and discusses why this is the case; and (3) it provides empirical evidence about the efficacy of installing single energy efficiency measures (EEMs) compared to packages of EEMs in small commercial buildings by reporting verified energy savings. To the authors’ knowledge, this paper is the first to catalog decision criteria and energy savings for the existing small commercial buildings market, and this research illustrates that small commercial building decision-makers seem most motivated to retrofit their spaces by energy cost savings and operational concerns. Furthermore, small commercial building decision-makers opted to implement single-system retrofits in fifteen (15) of the thirty-four cases studied. Finally, this research documents the improved savings, in the small commercial buildings market, associated with a more integrated package of EEMs compared to a single-system approach, achieving approximately 10% energy savings for a single-system approach and more than 20% energy savings for integrated approaches. These savings translate to CO2 savings of 1,324,000 kgCO2/year to 2,647,000 kgCO2/year, respectively, assuming small commercial buildings are retrofit at a rate of 0.95% of the stock annually.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigation of Energy Efficient Retrofit HVAC Systems for a University: Case Study

We did energy efficient retrofits for the Indiana University Purdue University—Indianapolis Health Science Building using the eQuest energy software. The current dual-fan dual-duct (DFDD) system is 41 years old and has a higher energy utilization index (EUI) than the national average for similar building types. The baseline model with the DFDD system was compared with the actual electrical consumption. Then, two energy efficiency measures (EEMs) were applied to the model. The first EEM was ‘DFDD system with chilled water and steam heating,’ and the second EEM was ‘single-duct variable air volume (VAV) with chilled water and electric reheat.’ After comparative simulations and analyses, it was determined that the ‘single duct VAV with chilled water and electric reheat’ was the most energy efficient and saved 28% in utility costs. The recommendation given to the facility services was to change the current DFDD system to the single-duct VAV system. The single-duct VAV system will save energy and create additional space above the ceiling after the heating duct is removed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measuring Impact: Evaluating Thermal Zoning Simplification on Energy Efficiency Measures Analysis

Building Energy Modeling (BEM) is a versatile tool for designing, retrofitting, ensuring code compliance, obtaining certifications, qualifying for incentives, and enabling real-time building control. However, capturing all the details of building geometry for thermal zoning can be time-consuming, costly, and sometimes computationally challenging. As a result, modelers have been applying zoning simplification based on factors such as space functions and internal loads, as well as relying on their experience and judgment while adhering to zoning rules outlined in industry standards. Despite the prevalence of this common practice, a notable gap exists in the literature regarding studies quantifying the influence of simplified thermal zoning on the evaluation of Energy Efficiency Measures (EEMs). Recognizing this gap, this paper seeks to contribute to the field by enhancing the understanding of how the simplification of thermal zoning influences the evaluation of EEMs against a baseline design. The study utilized a medium office prototype model with a detailed floor plan featuring over 20 zones per floor covering diverse functional spaces with varying internal loads and occupancy schedules. A standard thermal zoning strategy outlined in ASHRAE Standard 90.1 Appendix G was employed as the simplified zoning method. This strategy condenses the zoning into a core zone and four perimeter zones per floor. It was compared with the detailed zoning approach, which involves one zone per space. Common Energy EEMs, such as enhanced envelope, high-efficiency appliances and equipment, and HVAC controls, were individually implemented and evaluated. The results indicate that the performance comparison between the two zoning methods varies depending on the type of measures considered. Basic measures, such as adding wall insulation, demonstrate similar energy impacts, while advanced HVAC control measures, such as static pressure reset, exhibit a more substantial difference that cannot be overlooked.

Xie, Jiarong↗

NLR Core Modeling & Decision Support Capabilities: FASTSim, RouteE, T3CO & OpenPATH

This project is part of the program area to develop and improve core capabilities for the Energy-Efficient Mobility Systems (EEMS) program that enable research, development and deployment of advanced mobility solutions and enhance the EEMS Program's ability to address system-level transportation challenges. Advancements to the Future Automotive Systems Technology Simulator (FASTSim), Route Energy Prediction Model (RouteE), Transportation Technology Total Cost of Ownership (T3CO) and Open Platform for Agile Trip Heuristics (OpenPATH) core capabilities under this project supports the overall EEMS Program goals to effectively evaluate energy and mobility impacts of future transportation technologies and services, and to identify the most promising pathways to reduce transportation costs and environmental harms, and to improve mobility access. This presentation was prepared for the 2026 Annual Merit Review of this project.

33 ADVANCED PROPULSION SYSTEMS↗

iLIDS Simulations and Videos for Docking TIM

The video shows various aspects of the International Low Impact Docking System, including team members, some production, configuration, mated androgynous iLIDS, SCS Lockdown system, thermal analysis, electrical engineering aspects, the iLIDS control box and emulator, radiation testing at BNL, component environmental testing, component vibration testing, 3G processor board delivery system, GTA vibe test, EMA testbed, hook and hook disassembly, flex shaftdrive assembly, GSE cradle MISSE-6 Columbus, MISSE 6 and 7 seal experiments, actuated full scale seal test rig, LIDS on Hubble, dynamics test prep, EDU 54 mass emulation and SCS, load ring characterization, 6DOF proof test, SCS at 6DOF, machining EEMS and inner ring assembly, APAS assembly, inner ring fitting, rotation stand assembly, EEMS mating, and EEMS proof of concept demonstration.

Lewis, James L.↗

Thinking Like a Whole Building: A Whole Foods Market New Construction Case Study

Whole Foods Market participates in the U.S. Department of Energy's Commercial Building Partnerships (CBP) to identify and develop cost-effective, readily deployed, replicable energy efficiency measures (EEMs) for commercial buildings. Whole Foods Market is working with the National Renewable Energy Laboratory (NREL) on a retrofit and a new construction CBP project. Whole Foods Market's CBP newconstruction project is a standalone store in Raleigh, North Carolina. Whole Foods Market examined the energy systems and the interactions between those systems in the design for the new Raleigh store. Based on this collaboration and preliminary energy modeling, Whole Foods Market and NREL identified a number of cost-effective EEMs that can be readily deployed in other Whole Foods Market storesand in other U.S. supermarkets. If the actual savings in the Raleigh store - which NREL will monitor and verify - match the modeling results, each year this store will save nearly $100,000 in operating costs (Raleigh's rates are about $0.06/kWh for electricity and $0.83/therm for natural gas). The store will also use 41% less energy than a Standard 90.1-compliant store and avoid about 3.7million pounds of carbon dioxide emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thinking Like a Whole Building: Whole Foods Market New Construction Summary, U.S. Department of Energy's Commercial Building Partnerships (Fact Sheet)

Whole Foods Market participates in the U.S. Department of Energy's Commercial Building Partnerships (CBP) to identify and develop cost-effective, readily deployed, replicable energy efficiency measures (EEMs) for commercial buildings. Whole Foods Market is working with the National Renewable Energy Laboratory (NREL) on a retrofit and a new construction CBP project. Whole Foods Market's CBP new construction project is a standalone store in Raleigh, North Carolina. Whole Foods Market examined the energy systems and the interactions between those systems in the design for the new Raleigh store. Based on this collaboration and preliminary energy modeling, Whole Foods Market and NREL identified a number of cost-effective EEMs that can be readily deployed in other Whole Foods Market stores and in other U.S. supermarkets. If the actual savings in the Raleigh store - which NREL will monitor and verify - match the modeling results, each year this store will save nearly $100,000 in operating costs (Raleigh's rates are about $0.06/kWh for electricity and $0.83/therm for natural gas). The store will also use 41% less energy than a Standard 90.1-compliant store and avoid about 3.7 million pounds of carbon dioxide emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reducing Transaction Costs for Energy Efficiency Investments and Analysis of Economic Risk Associated With Building Performance Uncertainties: Small Buildings and Small Portfolios Program

The small buildings and small portfolios (SBSP) sector face a number of barriers that inhibit SBSP owners from adopting energy efficiency solutions. This pilot project focused on overcoming two of the largest barriers to financing energy efficiency in small buildings: disproportionately high transaction costs and unknown or unacceptable risk. Solutions to these barriers can often be at odds, because inexpensive turnkey solutions are often not sufficiently tailored to the unique circumstances of each building, reducing confidence that the expected energy savings will be achieved. To address these barriers, NREL worked with two innovative, forward-thinking lead partners, Michigan Saves and Energi, to develop technical solutions that provide a quick and easy process to encourage energy efficiency investments while managing risk. The pilot project was broken into two stages: the first stage focused on reducing transaction costs, and the second stage focused on reducing performance risk. In the first stage, NREL worked with the non-profit organization, Michigan Saves, to analyze the effects of 8 energy efficiency measures (EEMs) on 81 different baseline small office building models in Holland, Michigan (climate zone 5A). The results of this analysis (totaling over 30,000 cases) are summarized in a simple spreadsheet tool that enables users to easily sort through the results and find appropriate small office EEM packages that meet a particular energy savings threshold and are likely to be cost-effective.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Advance Local Mobility Through Energy Efficient Mobility Systems Technologies

Everyone deserves reliable, affordable, and safe transportation to connect people to jobs, healthcare, education, and recreation. Our transportation systems are interconnected, multimodal networks working together to move people and goods. These systems are dynamic and are being reshaped by factors such as population trends, new technologies, shifting labor models, economic forces, and changing climate. Energy efficient mobility systems (EEMS) technologies can help transportation planners ensure changes in our transportation systems are equitable and sustainable by improving energy efficiency, travel time, and affordability, as well as overall access to mobility. Transportation planners and decision makers can use the following EEMS tools and strategies to advance local mobility.

ADVANCED PROPULSION SYSTEMS↗

Vascular apoptosis associated with meglumine antimoniate: In vivo investigation of a chick embryo model

Highlights: • Meglumine antimoniate possesses vascular apoptotic effect. • Meglumine antimoniate alters expression of apoptotic-regulating genes. • Induction of apoptotic signaling pathways lead to vascular defect during pregnancy. • Meglumine antimoniate induces embryo malformation. • Physicians should limit the use of meglumine antimoniate during embryo development. The vasculo-toxic effect of meglumine antimoniate (MA) was confirmed in our previous investigation. The current study investigates the association of this effect with altered VEGF-A and VEGF-R2 expression. Additional mechanisms by which MA causes vascular toxicity are not clearly understood. We hypothesized that MA may alter normal expression of apoptotic genes and cause vascular toxicity. The current investigation was designed to address this issue using a chick embryo model. Fertile chicken eggs were treated with MA and the extra-embryonic membrane (EEM) vasculature was evaluated by morphometric, molecular and immunohistochemistry assays. The results showed that MA not only altered apoptotic gene expression, but that this alteration may disturb the normal development of the vascular network and cause embryo malformation. The relative expression level of the CASP3, CASP7, CASP9, APAF1, AIF1 and TP53 genes increased in drug-exposed EEMs. In addition, IHC assay confirmed the low expression BCL2 and increased expression of Bax, which are associated with a high rate of apoptosis. We suggest that induction of an apoptotic signaling pathway can lead to vascular defects during embryo development and the consecutive cascade of events can lead to the embryo malformation.

60 APPLIED LIFE SCIENCES↗