Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “eddy current”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

INNOVATIVE EDDY CURRENT PROBE FOR MICRO DEFECTS

This paper reports the development of an innovative eddy current (EC) probe, and its application to micro-defects on the root of the Friction Stir Welding (FSW). The new EC probe presents innovative concept issues, allowing 3D induced current in the material, and a lift-off independence. Validation experiments were performed on aluminium alloys processed by FSW. The results clearly show that the new EC probe is able to detect and sizing surface defects about 60 microns depth.

36 MATERIALS SCIENCE↗

Magnetic Diagnostics for Equilibrium Reconstructions in the Presence of Nonaxisymmetric Eddy Current Distributions in Tokamaks

The lithium tokamak experiment LTX is a modest-sized spherical tokamak R0=0.4 m and a =0.26 m designed to investigate the low-recycling lithium wall operating regime for magnetically confined plasmas. LTX will reach this regime through a lithium-coated shell internal to the vacuum vessel, conformal to the plasma last-closed-flux surface, and heated to 300-400 oC. This structure is highly conductive and not axisymmetric. The three-dimensional nature of the shell causes the eddy currents and magnetic fields to be three-dimensional as well. In order to analyze the plasma equilibrium in the presence of three-dimensional eddy currents, an extensive array of unique magnetic diagnostics has been implemented. Sensors are designed to survive high temperatures and incidental contact with lithium and provide data on toroidal asymmetries as well as full coverage of the poloidal cross-section. The magnetic array has been utilized to determine the effects of nonaxisymmetric eddy currents and to model the start-up phase of LTX. Measurements from the magnetic array, coupled with two-dimensional field component modeling, have allowed a suitable field null and initial plasma current to be produced. For full magnetic reconstructions, a three-dimensional electromagnetic model of the vacuum vessel and shell is under development.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetic diagnostics for equilibrium reconstructions in the presence of nonaxisymmetric eddy current distributions in tokamaks (invited)

The lithium tokamak experiment (LTX) is a modest-sized spherical tokamak (R{sub 0}=0.4 m and a=0.26 m) designed to investigate the low-recycling lithium wall operating regime for magnetically confined plasmas. LTX will reach this regime through a lithium-coated shell internal to the vacuum vessel, conformal to the plasma last-closed-flux surface, and heated to 300-400 deg. C. This structure is highly conductive and not axisymmetric. The three-dimensional nature of the shell causes the eddy currents and magnetic fields to be three-dimensional as well. In order to analyze the plasma equilibrium in the presence of three-dimensional eddy currents, an extensive array of unique magnetic diagnostics has been implemented. Sensors are designed to survive high temperatures and incidental contact with lithium and provide data on toroidal asymmetries as well as full coverage of the poloidal cross-section. The magnetic array has been utilized to determine the effects of nonaxisymmetric eddy currents and to model the start-up phase of LTX. Measurements from the magnetic array, coupled with two-dimensional field component modeling, have allowed a suitable field null and initial plasma current to be produced. For full magnetic reconstructions, a three-dimensional electromagnetic model of the vacuum vessel and shell is under development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Eddy Current for Sizing Cracks in Canisters for Dry Storage of Used Nuclear Fuel

The storage of used nuclear fuel (UNF) in dry canister storage systems (DCSSs) at Independent Spent Fuel Storage Installations (ISFSI) sites is a temporary measure to accommodate UNF inventory until it can be reprocessed or transferred to a repository for permanent disposal. Policy uncertainty surrounding the long-term management of UNF indicates that DCSSs will need to store UNF for much longer periods than originally envisioned. Meanwhile, the structural and leak-tight integrity of DCSSs must not be compromised. The eddy current technique is presented as a potential tool for inspecting the outer surfaces of DCSS canisters for degradation, particularly atmospheric stress corrosion cracking (SCC). Results are presented that demonstrate that eddy current can detect flaws that cannot be detected reliably using standard visual techniques. In addition, simulations are performed to explore the best parameters of a pancake coil probe for sizing of SCC flaws in DCSS canisters and to identify features in frequency sweep curves that may potentially be useful for facilitating accurate depth sizing of atmospheric SCC flaws from eddy current measurements.

dry storage↗

Quantitative void fraction measurement with an eddy current flowmeter for generation IV Sodium cooled Fast Reactor

This study was carried out to understand the response of an eddy current type flowmeter in two phase liquid-metal flow. We use the technique of ellipse fit and correlate the fluctuations in the angle of inclination of this ellipse with the void fraction. The effects of physical parameters such as coil excitation frequency and flow velocity have been studied. The results show the possibility of using an eddy current flowmeter as a gas detector for large void fractions. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Quantitative void fraction detection with an eddy current flowmeter for generation IV Sodium cooled Fast Reactor

This study was carried out to understand the response of an eddy current type flowmeter in two phase liquid-metal flow. We use the technique of ellipse fit and correlate the fluctuations in the angle of inclination of this ellipse with the void fraction. The effects of physical parameters such as coil excitation frequency and flow velocity have been studied. The results show the possibility of using an eddy current flowmeter as a gas detector for large void fractions. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Effects of eddy currents due to a vacuum chamber wall in the airgap of a moving-magnet linear actuator

This paper discusses the effects of eddy currents induced in an electrically conducting plate which is placed in the airgap of a linear synchronous actuator with moving permanent magnets. The eddy currents induced in this plate, which is part of a controlled atmosphere chamber, cause not only damping but also deteriorate the actuator performance by disturbing the position measurement with Hall sensors. Furthermore, feed-forward controllers are less effective due to the suppression of high frequent armature fields. These effects are analyzed with an analytical model and verified with finite element simulations and measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

COMPARATIVE ANALYSIS OF SELECTED EDDY CURRENT TRANSDUCERS FOR TITANIUM ALLOY EVALUATION

Titanium alloy based details due to their mechanical properties continue to be in extensive use in various structures (mainly aerospace, automotive and petro-chemical industrial applications). In this paper comparative study of various types of eddy current NDT transducers for testing titanium elements was done. Probes of absolute, differential and array configurations were constructed and analyzed. Two and three dimensional numerical analysis (FEM) were done in order to find the best type and configuration of the proposed transducers.

36 MATERIALS SCIENCE↗

Eddy Current Probe Parameters Identification Using a Genetic Algorithm and Simultaneous Perturbation Stochastic Approximation

This study tries to identify the coil parameters using numerical methods. The eddy current testing (ECT) is used for evaluation of a crack with the aid of numerical simulations by utilizing the identification of these parameters. In this study, a comparison of the performance of the GA and SPSA algorithms to identify the parameter values of the coil sensors are presented. So, the optimization probe geometry is introduced in the simulation with Three-dimensional finite element simulations (FLUX finite element code) were conducted to obtain eddy current signals resulting from a crack in a plate made of aluminium. The simulation results are compared with experimental measurements for the defect present in a plate.

42 ENGINEERING↗

Recent advances in modeling discontinuities in anisotropic and heterogeneous materials in eddy current NDE

Recent advances are presented to model discontinuities in random anisotropies that arise in certain materials, such as titanium alloys. A numerical model is developed to provide a full anisotropic representation of each crystalline in a gridded region of the material. Several simulated and experimental demonstrations are presented highlighting the effect of grain noise on eddy current measurements. Agreement between VIC-3D(c) model calculations and experimental data in titanium alloy specimens with known flaws is demonstrated.

36 MATERIALS SCIENCE↗

Exploring the eddy current excitation invariance to infer about defect characteristics

This paper explores the excitation probe excitation field invariance when the eddy current method is applied to detect, localize and characterize material defects in conductive nonmagnetic media. The cases relative to rotational symmetry in circular solenoidal probes and translation symmetry in constant field probes are presented. The experimental data shows that this theoretical treatment is useful to preview the behavior of these probes.

42 ENGINEERING↗

Baseline Evaluation of Eddy Current Testing for PWSCC Susceptible Materials

This technical letter report (TLR) summarizes technical efforts focused on assessments of eddy current testing (ET) examinations using various mockups for obtaining baseline surface and subsurface conditions on materials susceptible to primary water stress corrosion cracking (PWSCC). The scope of this work included nondestructive evaluation characterization of weld surfaces on mockups that were identified for application of various surface peening approaches. All of the work reported here was conducted prior to planned peening of these surfaces to evaluate pre-peening conditions, and subsequently compare the baseline ET results with post-peening conditions. The overall objective of this work was to demonstrate the effectiveness of employing ET for detecting near/sub-surface defects on mockups in support of peening assessments for surface stress improvement and mitigation of PWSCC in these materials. The U.S. Nuclear Regulatory Commission has communicated their expectations to industry for eddy current inspections of peened, inlayed, and onlayed dissimilar metal welds and is interested in better understanding detection performance and sensitivity of ET techniques to support the development of a technical foundation for detection and sizing limits, effective ET qualification requirements, alternate inspections or programs for evaluating PWSCC mitigation processes, and development of ET acceptance standards that can be referenced in the appropriate American Society of Mechanical Engineers Section XI Code Case (N-770-X). This TLR provides a technical discussion focused on the ET data obtained, the analysis, and conclusions drawn from surface examinations of various plate standards and actual components extracted from cancelled nuclear power plants.

36 MATERIALS SCIENCE↗

Crack detection using pulsed eddy current stimulated thermography

This contribution presents results from studies investigating factors that influence the detection of surface breaking cracks using pulsed eddy current thermography. The influences of the current strength and crack orientation in both ferromagnetic and non-ferromagnetic metals have been investigated. It has been found that crack detection is far more sensitive to crack orientation in non-ferromagnetic metals than in ferromagnetic metals. The effects of crack size on detectability are presented for a large number of steel, nickel alloy and titanium samples. Results of studies comparing crack images obtained prior and after coating a nickel alloy sample with a thermal barrier coating are presented.

36 MATERIALS SCIENCE↗

Influence of soil-structure interaction on performance of a super tall building using a new eddy-current tuned mass damper

Tuned mass dampers (TMDs) can be used as vibration control devices to improve the vibration performance of high-rise buildings. The Shanghai Tower (SHT) is a 632-m high landmark building in China, featuring a new eddy-current TMD. Special protective mechanisms have been adopted to prevent excessively large amplitude of the TMD under extreme wind or earthquake loading scenarios. This paper presents a methodology for simulating behavior of the new eddy-current TMD that features displacement-dependent damping behavior. The TMD model was built into the SHT finite element model to perform frequency analysis and detailed response analyses under wind and earthquake loads. Furthermore, soil-structure interaction (SSI) effects on wind and seismic load responses of the SHT model were investigated, as SSI has a significant impact on the vibration performance of high-rise buildings. It was found that SSI has more significant effects on acceleration response for wind loads with a short return period than for wind loads with a long return period. Some of the acceleration responses with SSI effects exceed design limits of human comfort for wind loads with shorter return periods. As to the seismic analyses, it was found that SSI slightly reduces the displacement amplitude, the damping force, and the impact force of the TMD.

42 ENGINEERING↗

An analytical demonstration of coupling schemes between magnetohydrodynamic codes and eddy current codes

In order to model a magnetohydrodynamic (MHD) instability that strongly couples to external conducting structures (walls and/or coils) in a fusion device, it is often necessary to combine a MHD code solving for the plasma response, with an eddy current code computing the fields and currents of conductors. We present a rigorous proof of the coupling schemes between these two types of codes. One of the coupling schemes has been introduced and implemented in the CARMA code [R. Albanese, Y. Q. Liu, A. Portone, G. Rubinacci, and F. Villone, IEEE Trans. Magn. 44, 1654 (2008); A. Portone, F. Villone, Y. Q. Liu, R. Albanese, and G. Rubinacci, Plasma Phys. Controlled Fusion 50, 085004 (2008)] that couples the MHD code MARS-F[Y. Q. Liu, A. Bondeson, C. M. Fransson, B. Lennartson, and C. Breitholtz, Phys. Plasmas 7, 3681 (2000)] and the eddy current code CARIDDI[R. Albanese and G. Rubinacci, Adv. Imaging Electron Phys. 102, 1 (1998)]. While the coupling schemes are described for a general toroidal geometry, we give the analytical proof for a cylindrical plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preliminary Design Study for an Eddy Current Flow Meter for Versatile Test Reactor

The eddy current flow meter (ECFM) serves the purpose of monitoring velocities and temperatures of conductive liquid coolant surrounding nuclear reactor cells. The ECFM can also detect voids in two-phase liquid metal flows. Measurement of this flow in reactor cells can greatly improve the accuracy of the empirical formulas used for fluid dynamics near the reactor core, as well as, aid in mapping any non-uniformities in fluid flow, its temperature estimation and phase. With modeling and experimental verification, an extensible ECFM for multiple facilities and environments can lead to an understanding of the liquid coolant flow; while saving cost of calibration and development. This can be done by characterizing the ECFM performance based on its parameters and then optimizing a sensor for a given use case. Simulation results using an ECFM and an aluminum rod medium are presented and discussed herein. Additionally, liquid metal simulations for Mercury and Galinstan will compare the ECFM behavior for different liquid velocities and excitation frequencies. After sensor calibration curves are generated and experimentally verified, ECFMs can be developed and deployed using the model introduced.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modified eddy current probe for low conductivity surfaces

A modified eddy current (MEC) probe includes a probe body having a bore formed therein. A printed circuit board (PCB) assembly includes a circuit board defining a plane, has a plurality of electronic components mounted thereon, and is configured for mounting within the bore of the probe body. A coil board assembly is electrically connected to the PCB assembly and comprises a coil board defining a plane, a transmitter coil formed on a first side of the coil board, and a sensor coil formed on second side of the coil board. The plane of the coil board is arranged orthogonally to the plane of the circuit board.

42 ENGINEERING↗

Modified eddy current probe having a faraday shield

A modified eddy current (MEC) probe includes a probe body having a bore formed therein. A printed circuit board (PCB) assembly includes a circuit board defining a plane, has a plurality of electronic components mounted thereon, and is configured for mounting within the bore of the probe body. A coil board assembly is electrically connected to the PCB assembly, defines a plane, and includes a first coil board layer, a second coil board layer bonded to the first coil board layer, a transmitter coil formed on an outside surface of the first coil board layer, a Faraday shield formed on an outside surface of the second coil board layer, and a sensor coil formed on one of an inside surface of the first coil board layer and the second coil board layer, such that the sensor coil is positioned between the first coil board layer and the second coil board layer. The plane of the coil board assembly is arranged orthogonally to the plane of the circuit board.

47 OTHER INSTRUMENTATION↗