Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dual imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Ion trap with in-vacuum high numerical aperture imaging for a dual-species modular quantum computer

Photonic interconnects between quantum systems will play a central role in both scalable quantum computing and quantum networking. Entanglement of remote qubits via photons has been demonstrated in many platforms; however, improving the rate of entanglement generation will be instrumental for integrating photonic links into modular quantum computers. We present an ion trap system that has the highest reported free-space photon collection efficiency for quantum networking. We use a pair of in-vacuum aspheric lenses, each with a numerical aperture of 0.8, to couple 10(1)% of the 493 nm photons emitted from a 138Ba+ ion into single-mode fibers. We also demonstrate that proximal effects of the lenses on the ion position and motion can be mitigated.

Instruments & Instrumentation↗

The Bimodal Absorption System Imaging Campaign (BASIC). I. A Dual Population of Low-metallicity Absorbers at z < 1

The bimodal absorption system imaging campaign (BASIC) aims to characterize the galaxy environments of a sample of 36 H I-selected partial Lyman limit systems (pLLSs) and Lyman limit systems (LLSs) in 23 QSO fields at z ≲ 1. These pLLSs/LLSs provide a unique sample of absorbers with unbiased and well-constrained metallicities, allowing us to explore the origins of metal-rich and low-metallicity circumgalactic medium (CGM) at z < 1. Here we present Keck/KCWI and Very Large Telescope/MUSE observations of 11 of these QSO fields (19 pLLSs) that we combine with Hubble Space Telescope/Advanced Camera for Surveys imaging to identify and characterize the absorber-associated galaxies at 0.16 ≲ z ≲ 0.84. We find 23 unique absorber-associated galaxies, with an average of one associated galaxy per absorber. For seven absorbers, all with <10% solar metallicities, we find no associated galaxies with logM * ≳ 9.0 within ρ/R vir and |Δv|/v esc ≤ 1.5 with respect to the absorber. We do not find any strong correlations between the metallicities or H I column densities of the gas and most of the galaxy properties, except for the stellar mass of the galaxies: the low-metallicity ([X/H] ≤ –1.4) systems have a probability of $0.39_{–0.15}^{+0.16}$ for having a host galaxy with logM * ≥ 9.0 within ρ/R vir ≤ 1.5, while the higher metallicity absorbers have a probability of $0.78_{–0.13}^{+0.10}$. This implies metal-enriched pLLSs/LLSs at z < 1 are typically associated with the CGM of galaxies with logM * > 9.0, whereas low-metallicity pLLSs/LLSs are found in more diverse locations, with one population arising in the CGM of galaxies and another more broadly distributed in overdense regions of the universe. Using absorbers not associated with galaxies, we estimate the unweighted geometric mean metallicity of the intergalactic medium to be [X/H] ≲ –2.1 at z < 1, which is lower than previously estimated.

79 ASTRONOMY AND ASTROPHYSICS↗

Computational microscopy for fast widefield deep-tissue fluorescence imaging using a commercial dual-cannula probe

A solid-glass cannula serves as a micro-endoscope that can deliver excitation light deep inside tissue while also collecting emitted fluorescence. Then, we utilize deep neural networks to reconstruct images from the collected intensity distributions. By using a commercially available dual-cannula probe, and training a separate deep neural network for each cannula, we effectively double the field of view compared to prior work. We demonstrated ex vivo imaging of fluorescent beads and brain slices and in vivo imaging from whole brains. We clearly resolved 4 µm beads, with FOV from each cannula of 0.2 mm (diameter), and produced images from a depth of ∼1.2 mm in the whole brain, currently limited primarily by the labeling. Since no scanning is required, fast widefield fluorescence imaging limited primarily by the brightness of the fluorophores, collection efficiency of our system, and the frame rate of the camera becomes possible.

42 ENGINEERING↗

Automated scanning probe microscopy of combinatorial ferroelectric libraries: Gaussian-process-guided exploration and noise-aware experiment planning

Combinatorial materials libraries provide an efficient route for mapping composition–property relationships, but their broader impact depends on rapid, quantitative, and functionally relevant characterization. Scanning Probe Microscopy (SPM), including piezoresponse force microscopy (PFM), offers significant potential for quantitative, functionally relevant combi-library readouts. Here, we implement a fully automated SPM workflow for ferroelectric combinatorial libraries and benchmark Gaussian-process-based Bayesian optimization strategies for autonomous experiment planning. The workflow integrates automated probe motion, contact optimization, imaging, and dual amplitude resonance tracking-PFM spectroscopy, and uses scalarized spectroscopic observables to guide subsequent measurements. Stage motion, probe engagement, in-contact tuning, imaging, spectroscopy, and the choice of the next measurement location all proceed without human input. We demonstrate the approach on Sm-doped BiFeO 3 and Zn x Mg 1−x O libraries. By comparing vanilla Bayesian optimization with a measured-noise variant, we show that explicit treatment of local reproducibility can improve modeling of composition-dependent response when the measured variance is physically meaningful, but can also reduce robustness when variability is dominated by outliers or topographic artifacts. Furthermore, these results establish automated SPM as a bridge between combinatorial synthesis and quantitative functional characterization.

Liu, Yu [University of Tennessee, Knoxville, TN (U↗

The 𝑚=2 amplituhedron and the hypersimplex: Signs, clusters, tilings, Eulerian numbers

The hypersimplex Δ <#comment/> k + 1 , n \Delta _{k+1,n} is the image of the positive Grassmannian G r k + 1 , n ≥ <#comment/> 0 Gr^{\geq 0}_{k+1,n} under the moment map. It is a polytope of dimension n − <#comment/> 1 n-1 in R n \mathbb {R}^n . Meanwhile, the amplituhedron A n , k , 2 ( Z ) \mathcal {A}_{n,k,2}(Z) is the projection of the positive Grassmannian G r k , n ≥ <#comment/> 0 Gr^{\geq 0}_{k,n} into the Grassmannian G r k , k + 2 Gr_{k,k+2} under a map Z ~ <#comment/> \tilde {Z} induced by a positive matrix Z ∈ <#comment/> M a t n , k + 2 > 0 Z\in Mat_{n,k+2}^{>0} . Introduced in the context of scattering amplitudes , it is not a polytope, and has full dimension 2 k 2k inside G r k , k + 2 Gr_{k,k+2} . Nevertheless, there seem to be remarkable connections between these two objects via T-duality , as conjectured by Łukowski, Parisi, and Williams [Int. Math. Res. Not. (2023)]. In this paper we use ideas from oriented matroid theory, total positivity, and the geometry of the hypersimplex and positroid polytopes to obtain a deeper understanding of the amplituhedron. We show that the inequalities cutting out positroid polytopes —images of positroid cells of G r k + 1 , n ≥ <#comment/> 0 Gr^{\geq 0}_{k+1,n} under the moment map—translate into sign conditions characterizing the T-dual Grasstopes —images of positroid cells of G r k , n ≥ <#comment/> 0 Gr^{\geq 0}_{k,n} under Z ~ <#comment/> \tilde {Z} . Moreover, we subdivide the amplituhedron into chambers , just as the hypersimplex can be subdivided into simplices, with both chambers and simplices enumerated by the Eulerian numbers. We use these properties to prove the main conjecture of Łukowski, Parisi, and Williams [Int. Math. Res. Not. (2023)]: a collection of positroid polytopes is a tiling of the hypersimplex if and only if the collection of T-dual Grasstopes is a tiling of the amplituhedron A n , k , 2 ( Z ) \mathcal {A}_{n,k,2}(Z) for all Z Z . Moreover, we prove Arkani-Hamed–Thomas–Trnka’s conjectural sign-flip characterization of A n , k , 2 \mathcal {A}_{n,k,2} , and Łukowski–Parisi–Spradlin–Volovich’s conjectures on m = 2 m=2 cluster adjacency and on positroid tiles for A n , k , 2 \mathcal {A}_{n,k,2} (images of 2 k 2k -dimensional positroid cells which map injectively into A n , k , 2 \mathcal {A}_{n,k,2} ). Finally, we introduce new cluster structures in the amplituhedron.

Parisi, Matteo↗

Artificial Intelligence for imaging Cherenkov detectors at the EIC

Abstract Imaging Cherenkov detectors form the backbone of particle identification (PID) at the future Electron Ion Collider (EIC). Currently all the designs for the first EIC detector proposal use a dual Ring Imaging CHerenkov (dRICH) detector in the hadron endcap, a Detector for Internally Reflected Cherenkov (DIRC) light in the barrel, and a modular RICH (mRICH) in the electron endcap. These detectors involve optical processes with many photons that need to be tracked through complex surfaces at the simulation level, while for reconstruction they rely on pattern recognition of ring images. This proceeding summarizes ongoing efforts and possible applications of AI for imaging Cherenkov detectors at EIC. In particular we will provide the example of the dRICH for the AI-assisted design and of the DIRC for simulation and particle identification from complex patterns and discuss possible advantages of using AI.

Instruments & Instrumentation↗

Gamma-ray imaging of Np-237 metal using an organic glass imager

Neutron and gamma-ray imaging systems are deployed within the field of nuclear safeguards for the detection and localization of special nuclear materials and other materials of interest. 237 Np is one of these materials of interest due its presence in spent nuclear fuel and potential for use in nuclear weapons when purified. Here, for the first time, a 6 kg neptunium sphere (98.8 wt% 237 Np) was measured using a dual-particle imager, from the University of Michigan, consisting of organic glass and inorganic scintillators. The novel composition of organic glass scintillator was recently developed at Sandia National Labs and has been used in particle imaging systems due to its time resolution and particle discrimination capabilities. Gamma-ray energy spectra from single and coincident events were extracted and the sequencing of Compton scatter and photoelectric absorption gamma-ray events was used to generate images using simple backprojection. The emissions of interest in this work are the 312 keV and 416 keV gamma rays from 233 Pa, a daughter isotope from the neptunium decay series. The results of this work show that there is close agreement between the true source location in angular space and the converged location from the gamma ray images created using the system. The gamma spectroscopy from single and coincident events also identified the characteristic emission from the daughter isotope and could be used to assist with the identification of 237 Np. Furthermore, successful localization of the source with 5 s of data demonstrates the practical application of the imaging system for imaging and detection of material in weapons-useable quantities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Separate-Effects Tests for Studying Temperature-Gradient-Driven Cracking in UO 2 Pellets

We report a variety of normal operation and accident scenarios can generate thermal stresses large enough to cause cracking in light-water reactor (LWR) fuel pellets. Cracking of fuel pellets can lead to reduced heat removal, higher centerline temperatures, and localized stress in cladding, all of which impact fuel performance. It is important to experimentally characterize the thermal and mechanical behavior in the pellet before and after cracking to improve cracking models in fuel performance codes. However, in-reactor observation and measurement of cracking is very challenging due to the harsh environment and logistics. Recently, an experimental pellet cracking test stand was developed for separate effects testing of normal operations and accident temperature conditions, using thermal imaging to capture the pellet surface temperature for evaluation of thermal stresses and optical imaging to capture the evolution of cracking in real time. Experiments were performed using depleted uranium dioxide (UO 2 ) pellets, which are useful for collecting data valuable for development and validation of cracking models. A combination of induction and resistance heating was used to create an average temperature gradient of 236°C/cm and 193°C/cm before and after cracking respectively. Characterization of the pellets were done before as well as after cracking. The cracking patterns are somewhat different than those expected in a typical reactor because of the differences in thermal conditions and pellet microstructure. However, if the actual conditions of these experiments are reproduced in computational models, these out-of-pile tests on UO 2 pellets provide relevant data for modeling purposes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Simulation study for particle identification with the dRICH of the ePIC experiment at the EIC

The dual-radiator Imaging Cherenkov detector (dRICH), employing an aerogel and a gas radiator, is a key component of the forward particle identification system for the ePIC experiment at the Electron-Ion Collider (EIC). This study evaluates the dRICH performance using Geant4 simulations in the context of the global ePIC simulation stack, focusing on the optimization of the aerogel radiator and the impact of sensor noise. We compare two aerogel configurations: the initial design (n = 1.019) and the current default (n = 1.026). The latter, characterized by improved optical properties and a higher refractive index, demonstrates enhanced π/K separation at high momenta, effectively extending the operational overlap with the C 2 F 6 gas radiator (n = 1.00076 at 25 °C, as implemented in the simulation software). Additionally, the study investigates the impact of Silicon Photomultiplier (SiPM) dark noise, showing that a 300 kHz noise rate per 3mm x 3mm channel leads to a moderate reduction (approximately 1.5 GeV/c) in the 3σ separation threshold. These results validate the current dRICH design and quantify the purity levels achievable for both radiators under expected experimental conditions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reuniting crystallography with real space: Ab initio structure elucidation with 4D-STEM

Structure elucidation via single-crystal methods has historically lacked experimental access to real-space information, instead relying exclusively on diffraction-space measurements of Bragg reflections. Here we exploit the dual-space imaging power of 4D scanning transmission electron microscopy to meaningfully integrate real-space information into the crystallographic workflow. We show that virtual apertures assembled by segmentation of high-angle annular dark-field images enable i) pixel-by-pixel separation of coherent Bragg signal from clusters of closely spaced nanocrystals and ii) selective extraction of integrated intensities from thinner subregions of individual specimens, facilitating retroactive tuning of multiple scattering artifacts. This strategy empowers us to simply pick and choose whichever nanoscale regions of interest generate the highest-quality diffraction patterns, allowing us to solve several independent structures of the metal-organic framework UiO-66 from specimens whose agglomerated morphology proved intractable for conventional microcrystal electron diffraction. Our method is compatible with both rotational and serial approaches to data processing, ultimately divulging the first scanning nanobeam electron diffraction structures determined by direct methods at subangstrom resolution.

Saha, Ambarneil↗

Advanced Collision Detection and Site Monitoring for Avian and Bat Species for Offshore Wind Energy (Final Technical Report)

This final technical report summarizes the outcomes from a project that aimed to design, build, and test a persistent and autonomous monitoring system for avian and bat collisions with offshore wind turbines blades and structures. The system comprises four primary sensor modules: 1) on-blade sensor modules for collision detection and dual-vision image capture on each blade with both visible light and near-infrared imagers; 2) additional on-blade collision sensors mounted further from the root; 3) a nacelle-mounted unit including a 360º camera and ultrasonic microphone array; and, 4) an on-blade, high-performance infrared camera module. Primary targeted outcomes were high sensitivity for the detection of blade strikes from bats and small birds, and automatically captured visual confirmation of the striking object; these features are critical for monitoring offshore wind turbine installations, where ground-based methods are not viable. In addition, local recording will provide a long-term sensor recording database. Following laboratory validation, field testing was conducted on an operational wind turbine in collaboration with the National Wind Technology Center at the NREL Flatirons campus over two planned field tests.

17 WIND ENERGY↗

Comparison of automated chemical-guided segmentation and human annotation of soil organic matter in X-ray microcomputed tomography imaging in contrasted soil types

Soil organic matter (OM) formation and persistence is strongly influenced by the spatial distribution of organic substrates and microscale soil heterogeneity by dictating OM accessibility to microorganisms. However, traditional size and/or density fractionation techniques disrupt aggregate architecture, eliminating spatial information needed to fully understand intra-aggregate OM distribution. To quantify three-dimensional OM spatial distribution and automate segmentation in X-ray microcomputed tomography (µCT) imaging without human annotation bias, we developed an iodine gas vapor (I2) based staining workflow that eliminates labor-intensive manual annotation while maintaining segmentation accuracy, using aggregates from four taxonomically diverse soils (Xerofluvent, Haploxeroll Sphagnofibrist, Palehumult) with an 8-fold range of soil organic carbon. Human annotation of 10 µCT slices by the experienced and inexperienced annotators resulted in variations up to 3% in the Dice similarity coefficient (DSC), reflecting a degree of inherent subjectivity of manual labeling. Such inconsistencies are expected to compound as the number of manually annotated slices increases. Dual-energy µCT imaging at 33.1 keV (below the iodine (I) K-edge) and 33.2 keV (above the I K-edge) was used to resolve aggregate microstructure following I2 staining. The automated image subtraction pipeline identified OM regions by the I Kedge induced brightness increases, achieving DSC values of 0.58–0.83 relative to an experienced annotator. Sensitivity analyses revealed that the reconstruction alpha value—optimized via the open-source tool TomocuPy—and the 3D registration slice count were the primary determinants of accuracy, providing a novel benchmark for dual-energy soil imaging. The pipeline without GPU acceleration achieved 9.6 to 43.2 times faster than manual annotation. Using GPU-accelerated image post-processing and affine transformation matrices, the pipeline successfully segmented OM elements for large-scale datasets (3232×3232 pixel, 2048 slices) within ~5200 s from raw file acquisition to segmented output. The high-throughput approach enables the quantification of OM spatial distribution across diverse and heterogeneous soil.

Soil microbial biomass↗

Power-Dependent Dual Analyte Tip-Enhanced Raman Spectral Imaging

In this work, we explore the information content in tip-enhanced Raman (TER) spectral images of gold nanoplates coated with two distinct molecular reporters: 4-thiobenzonitrile (TBN) and 4-nitrothiophenol (NTP). Using our dual analyte approach, we rigorously demonstrate pixel-limited spatial resolution in Raman nano-images that are otherwise dominated by local optical fields that vary more gently in space. Reproducibility is ensured through power dependent TERS mapping. Power-dependent imaging also (i) directly illustrates that TBN is more robust than NTP at higher laser powers, and (ii) reveals an increase in population of the Stark-tuned nitrile resonances of TBN molecules with increasing incident laser power.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

RockFlow: Fast Generation of Synthetic Source Rock Images Using Generative Flow Models

Image-based evaluation methods are a valuable tool for source rock characterization. The time and resources needed to obtain images has spurred development of machine-learning generative models to create synthetic images of pore structure and rock fabric from limited image data. While generative models have shown success, existing methods for generating 3D volumes from 2D training images are restricted to binary images and grayscale volume generation requires 3D training data. Shale characterization relies on 2D imaging techniques such as scanning electron microscopy (SEM), and grayscale values carry important information about porosity, kerogen content, and mineral composition of the shale. Here, we introduce RockFlow, a method based on generative flow models that creates grayscale volumes from 2D training data. We apply RockFlow to baseline binary micro-CT image volumes and compare performance to a previously proposed model. We also show the extension of our model to 2D grayscale data by generating grayscale image volumes from 2D SEM and dual modality nanoscale shale images. The results show that our method underestimates the porosity and surface area on the binary baseline datasets but is able to generate realistic grayscale image volumes for shales. With improved binary data preprocessing, we believe that our model is capable of generating synthetic porous media volumes for a very broad class of rocks from shale to carbonates to sandstone.

58 GEOSCIENCES↗

Vector elastic deconvolution migration with dual wavefield decomposition

Here, we report elastic-wave imaging using multicomponent data can provide more useful subsurface information than acoustic-wave imaging, but it is usually algorithmically challenging. We have developed a vector elastic deconvolution migration method for high-resolution imaging of subsurface structures in isotropic and anisotropic elastic media. Our new method uses a vector deconvolution imaging condition based on dual wavefield decomposition, including an explicit directional wavefield separation using the Hilbert transform and a P/S vector wavefield decomposition using the low-rank decomposition method. Using three elastic models, we numerically determine that our new method produces notably higher resolution and more amplitude-balanced elastic images compared with a crosscorrelation-based vector elastic reverse time migration method.

58 GEOSCIENCES↗