Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “drops”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The Role of Normal Stress and Shear Stress Heterogeneity in the Inferred Depth‐Independence of Stress Drop

Earthquake stress drops are inferred to be independent of source depth, contradicting linear scaling predictions for earthquakes as frictional stick‐slip instabilities that assume increasing fault normal stress due to overburden. Here, we examine the scaling between averaged stress drops and increasing normal stress for simulated earthquake sequences in continuum rate‐and‐state fault models. The models produce a weaker dependence of stress drop on normal stress than the linearity of simple friction, which can be well‐fit by a sublinear power‐law. This result is more prominent when the fault dimension is much larger than nucleation scales. In such cases, the averaged behavior of ruptures is dominated by rupture propagation conditions, reflecting more heterogeneous shear stress conditions. As natural faults can be considerably larger than the smallest earthquakes they host, such a weaker scaling between averaged rupture conditions and normal stress may partially explain the lack of an inferred depth‐dependence of earthquake stress drops.

earthquake source↗

Prediction of heat transfer coefficient from pressure drop using machine learning techniques in smooth horizontal pipes

Limited experimental work has been done focusing specifically on the relationship between pressure drop and heat transfer in the transient flow regime in pipes. The aim of this study was therefore to use machine learning to find a relationship between pressure drop and heat transfer coefficients of developing and fully developed flow in smooth horizontal circular tubes in the laminar, transient, quasi-turbulent and turbulent. The data are collected from literature, coming from experimentation. Pressure drops and heat transfer measurements were taken simultaneously and the relationship between pressure drop, and heat transfer was determined using multiple machine learning techniques.

20 FOSSIL-FUELED POWER PLANTS↗

ECAR-6330 Rev 0 Computational Fluid Dynamics Evaluation of Core Pressure Drop for the Primary Coolant Apparatus Test

PCAT is a thermal-hydraulic test loop for MARVEL reactor. The design gap thickness between the heater rods of PCAT core is 1.0 mm. The heater elements were manufactured within a straightness tolerance for the designed gap thickness, but several elements have been distorted out of tolerance during the welding process. The distortion of heater rods could lead to flow maldistribution and excessive hotspot temperature when the gap between two heater rods is too narrow. Wire-wraps are the spacer devices widely used in the sodium cooled fast reactor system to maintain the design fuel pitch. Generally, a wire spacer can enhance the turbulent heat transfer, but it increases the pressure drop, which is not desirable for a natural-circulation system like PCAT. Therefore, three short wire-wrap spacers per heater have been proposed to contain the core pressure drops and keep the heater-to-heater gap in an acceptable range. The objectives of this ECAR is to evaluate the PCAR core pressure drop with short wire spacers to confirm that the additional pressure drop due to the wire spacer will not disturb the natural circulation of the PCAT.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Fungal drops: a novel approach for macro- and microscopic analyses of fungal mycelial growth

Abstract This study presents an inexpensive approach for the macro- and microscopic observation of fungal mycelial growth. The ‘fungal drops’ method allows to investigate the development of a mycelial network in filamentous microorganisms at the colony and hyphal scales. A heterogeneous environment is created by depositing 15–20 µl drops on a hydrophobic surface at a fixed distance. This system is akin to a two-dimensional (2D) soil-like structure in which aqueous-pockets are intermixed with air-filled pores. The fungus (spores or mycelia) is inoculated into one of the drops, from which hyphal growth and exploration take place. Hyphal structures are assessed at different scales using stereoscopic and microscopic imaging. The former allows to evaluate the local response of regions within the colony (modular behaviour), while the latter can be used for fractal dimension analyses to describe the hyphal network architecture. The method was tested with several species to underpin the transferability to multiple species. In addition, two sets of experiments were carried out to demonstrate its use in fungal biology. First, mycelial reorganization of Fusarium oxysporum was assessed as a response to patches containing different nutrient concentrations. Second, the effect of interactions with the soil bacterium Pseudomonas putida on habitat colonization by the same fungus was assessed. This method appeared as fast and accessible, allowed for a high level of replication, and complements more complex experimental platforms. Coupled with image analysis, the fungal drops method provides new insights into the study of fungal modularity both macroscopically and at a single-hypha level.

Buffi, Matteo↗

Lifetime extension drop-test of real-world corroded 5 Quart Hagan nuclear material storage container

A 5Qt Hagan container with a 20-year history of nuclear material storage was challenged with three successive drop tests at a height of 3.7 meters. The total mass of the test package was 12.1 kg. The 1st and 2nd drop tests (center of gravity over the container bottom corner but 180 degrees apart on the container bottom face) passed the pre- and post- impact helium leak criterion at less than 1.00E-6 atm-cc/sec (ambient cubic centimeters per second). The 3rd and final test (center of gravity over top corner) failed with a post-impact gross leak of 1.1E-1 atmcc/sec. The RRFMC (Respirable Release Fraction Measurement Chamber) is a drop tower test system that is critical for the sustainability of the SAVY-4000™ series and Hagan-type (NFT Inc. Golden CO) nuclear material storage containers. These are the primary in-use nuclear material storage container types at the Los Alamos National Laboratory TA-55 facility. Results are presented to expand the technical knowledge basis for container lifetime, regarding actual exposure to corrosive gas species on the container inner surfaces. The primary source of general corrosion throughout the container is gaseous hydrogen chloride (HCl). This gas is generated by the degradation of the polyvinylchloride (PVC) bag-out bag. Additionally, in most cases, the nuclear material itself also releases HCl gas (due to residual chemical components associated with the material formation). The RRFMC drop tower gives the end-user the ability record and analyze high-speed video and photography and if needed aerosol mass release measurements. In this report the principal issue is the physical deformation of the 5Qt Hagan container. There were no mass release experiments of test aerosol mass in the present study.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Rapid Spaceborne Mapping of Wildfire Retardant Drops for Active Wildfire Management

Aerial application of fire retardant is a critical tool for managing wildland fire spread. Retardant applications are carefully planned to maximize fire line effectiveness, improve firefighter safety, protect high-value resources and assets, and limit environmental impact. However, topography, wind, visibility, and aircraft orientation can lead to differences between planned drop locations and the actual placement of the retardant. Information on the precise placement and areal extent of the dropped retardant can provide wildland fire managers with key information to (1) adaptively manage event resources, (2) assess the effectiveness of retardant slowing or stopping fire spread, (3) document location in relation to ecologically sensitive areas; and perform or validate cost-accounting for drop services. This study uses Sentinel-2 satellite data and commonly used machine learning classifiers to test an automated approach for detecting and mapping retardant application. We show that a multiclass model (retardant, burned, unburned, and cloud artifact classes) outperforms a single-class retardant model and that image differencing (post-application minus pre-application) outperforms single-image models. Compared to the random forest and support vector machine, the gradient boosting model performed the best with an overall accuracy of 0.88 and an F1 Score of 0.76 for fire retardant, though results were comparable for all three models. Our approach maps the full areal extent of the dropped retardant within minutes of image availability, rather than linear representations currently mapped by aerial GPS surveys. The development of this capability allows for the rapid assessment of retardant effectiveness and documentation of placement in relation to sensitive environments.

54 ENVIRONMENTAL SCIENCES↗

Drop Analysis of Department of Energy Standard Canister with Fort Saint Vrain SNF

DOE manages over 300 types of SNF, most of which are located at the INL site. The Idaho Cleanup Project and INL are collaborating on the Road-Ready Capability Demonstration Project, which will develop and demonstrate the designs, technology, processes, and regulatory framework for packaging DOE-managed SNF at the INL site for ?road-ready dry storage?. ?Road-ready dry storage? is a SNF management concept where SNF is packaged into dry and sealed canisters, which are then placed in on-site storage in anticipation of later transportation. The forward-looking goal of the Demonstration is establishing the foundation for a large-scale road-ready dry storage program at the INL site. The Demonstration will first package Fort Saint Vrain SNF currently stored at INL into several DOE Standard Canisters. These Standard Canisters will then be loaded into another commercial transportation or storage containment system (e.g., storage cask or transportation package). The Standard Canister is a class of standardized canisters designed for containing the large variety of DOE-managed SNF during interim storage, transportation and/or disposal at a geological repository. One critical aspect of road-ready dry storage is the ability to license the DOE Standard Canisters and its associated transportation package to 10 CFR 71. Depending on the SNF and transportation strategy, the Standard Canisters may have to maintain structural integrity under normal conditions of transport and hypothetical accident scenarios (i.e., drop events). The Standard Canisters have been tested and analyzed under various SNF loading configurations and accident drop events in support of the Idaho Spent Fuel Facility and other DOE programs. However, no analysis has been completed to support the recent Demonstration. This analysis will consider the Ø0.5 m × 5.1 m Standard Canister under drop scenario(s) considered in previous INL tests and analyses, including the 9 m drop at 80 degree off vertical. However, this analysis will consider the more recent Fort Saint Vrain loading configurations proposed for the Demonstration. This analysis will performed using strain-based acceptance criteria established by the American Society of Mechanical Engineers Boiler and Pressure Vessel Code, Section III, Division 3. It will be compared to previous analyses and form the foundation of further formal calculations that will be used to support licensing efforts of the road-ready dry storage system at INL.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Improvement of Drop‐Hammer Impact Testing for Safety Assessment of High Explosives Using 10‐mg Samples

Here, in this study, we established an improved method for drop-hammer impact testing of small quantities of high explosives (10 mg). We performed about seven hundred impact tests under various experimental conditions (e.g., sandpaper vs bare anvil, different sample masses, drop-weights, and striker diameters) to determine an optimal set of conditions and reaction detection methods (e.g., gas analysis, video, and sound recordings) that give the most statistically reliable results with 10 mg samples. We used both Frequentist and Bayesian statistical approaches to compare estimates of the drop height (DH50) that initiates a reaction 50% of the time, and to quantify the associated uncertainty. Gas analysis proved to be the most reliable reaction detection method, showing unambiguous rises in HE decomposition products (e.g., CO 2 ) even when the other indicators (e.g., sound, video) were inconclusive. The impact tests performed with a bare anvil showed much better reproducibility than those conducted with sandpaper, reducing the largest uncertainty observed in the data sets by a factor of 1.7. The DH 50 values obtained from three different sample masses (10, 20, and 35 mg) fell within the uncertainties of the measurements. We demonstrated the improved procedure (i.e., 10-mg samples, gas analysis, bare anvil, and Bayesian approach) on a variety of PETN samples having different surface areas and thermal histories.

PETN↗

An improved pressure drop correlation for modeling localized effects in a pebble bed reactor

Advances in the development of pebble bed reactors (PBRs) has created a desire for accurate and cost-effective simulation tools for design scoping studies and safety analysis. The current state-of-the-art for these simulations is the use of porous media models, although these models rely on correlations to capture the effects of flow features that are not explicitly modeled. One of the areas where correlation accuracy is currently lacking is in the near-wall region of the bed. In this region, the presence of the wall causes the pebbles to pack more orderly, drastically changing the geometry and flow behavior in this region. This work presents a new generalized pressure drop correlation for PBRs based on the KTA equation. A high-to-low methodology is applied, where large eddy simulation (LES) is performed on two beds of 1568 and 1700 pebbles to generate a high-fidelity dataset. The flow fields are then averaged in time and separated into concentric rings of 0.05 D peb width. Average porosity, velocity, and pressure drop are extracted for each ring and the friction and form losses are calculated. The Reynolds number range for this study is 625–10,000, and thus the form losses are dominant over the friction losses. The form losses across the rings are investigated, and a correction term for the form loss calculation is determined and applied to the KTA equation to drastically improve the capability of modeling localized porosity effects in a porous media code. Finally, the improved correlation reduces near-wall velocity prediction error from over 50% with the KTA correlation to around 5%. Agreement in pressure drop prediction between LES and porous media simulations is also improved.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaporation and propagation of liquid drop streams at vacuum pressures: Experiments and modeling

Evaporation of streams of liquid droplets in environments at vacuum pressures below the vapor pressure has not been widely studied. Here, experiments and simulations are reported that quantify the change in droplet diameter when a steady stream of ≈100 μm diameter drops is injected into a chamber initially evacuated to <10 –8 bar. In experiments, droplets fall through the center of a 0.8 m long liquid nitrogen cooled shroud, simulating infinity radiation and vapor mass flux boundary conditions. Furthermore, experimentally measured changes in drop diameters vary from ≈0 to 6 μm when the initial vapor pressure is increased from 10 –6 to 10 –3 bar by heating the liquid. Measured diameter changes are predicted by a model based on the Hertz-Knudsen equation. One uncertainty in the calculation is the “sticking coefficient” β. Assuming a constant β for all conditions studied here, predicted diameter changes best match measurements with β≈0.3. This value falls within the range of β reported in the literature for organic liquids. Finally, at the higher vapor pressure conditions considered here, the drop stream disperses transverse to the main flow direction. This spread is attributed to forces imparted by an absolute pressure gradient produced by the evaporating stream.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Drop Size Distribution Variability in Central Argentina during RELAMPAGO-CACTI

The Remote sensing of Electrification, Lightning, And Meso-scale/micro-scale Processes with Adaptive Ground Observations (RELAMPAGO) and the Cloud, Aerosol, and Complex Terrain Interactions Experiment Proposal (CACTI) field campaigns provided an unprecedented thirteen-disdrometer dataset in Central Argentina during the Intensive (IOP, 15 November to 15 December 2018) and Extended (EOP, 15 October 2018 to 30 April 2019) Observational Periods. The drop size distribution (DSD) parameters and their variability were analyzed across the region of interest, which was divided into three subregions characterized by the differing proximity to the Sierras de Córdoba (SDC), in order to assess the impact of complex terrain on the DSD parameters. A rigorous quality control of the data was first performed. The frequency distributions of DSD-derived parameters were analyzed, including the normalized intercept parameter (logN w ), the mean volume diameter (D 0 ), the mean mass diameter (D m ), the shape parameter (μ), the liquid water content (LWC), and the rain rate (R). The region closest to the SDC presented higher values of logN w , lower D 0 , and higher μ, while the opposite occurred in the farthest region, i.e., the concentration of small drops decreased while the concentration of bigger drops increased with the distance to the east of the SDC. Furthermore, the region closest to the SDC showed a bimodal distribution of D 0 : the lower values of D 0 were associated with higher values of logN w and were found more frequently during the afternoon, while the higher D 0 were associated with lower logN w and occurred more frequently during the night. The data were analyzed in comparison to the statistical analysis of Dolan et al. 2018 and sorted according to the classification proposed in the cited study. The logN w -D 0 and LWC-D 0 two-dimensional distributions allowed further discussion around the applicability of other mid-latitude and global precipitation classification schemes (startiform/convection) in the region of interest. Finally, three precipitation case studies were analyzed with supporting polarimetric radar data in order to relate the DSD characteristics to the precipitation type and the microphysical processes involved in each case.

54 ENVIRONMENTAL SCIENCES↗

RRFMC Drop Tester: Conduct of R&D Engineering System Risk Assessment

This report provides a documented risk assessment and subsequent determination of engineering rigor for the modification of the drop tester system inside of the Respirable Release Fraction Measurement Chamber (RRFMC) located in TA03-130. This risk assessment does not apply to the modification of the structural support system, containment barrier, pressure system, nor fluid system of the RRFMC, but only seeks to address the risk associated with the specific system used to raise and drop test articles.

42 ENGINEERING↗

Pure quark and gluon observables in collinear drop

We construct a class of pure quark and gluon observables by using the collinear drop grooming technique. The construction is based on linear combinations of multiple cumulative distributions of the jet mass in collinear drop, whose specific weights are fully predicted perturbatively. This yields observables which obtain their values purely from quarks (or purely from gluons) in a wide region of phase space. We demonstrate this by showing that these observables are effective in two phase space regions, one dominated by perturbative resummation and one dominated by nonperturbative effects. The nonperturbative effects are included using shape functions which only appear as a common factor in the linear combinations constructed. We test this construction using a numerical analysis with next-to-leading logarithmic resummation and various shape function models, as well as analyzing these observables with PYTHIA and VINCIA. Choices for the collinear drop parameters are optimized for experimental use.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ultra-low thermal resistance and pressure drop copper and copper-tungsten diamond-shaped pin fin cold plates for liquid cooling of electronics

Modern and future data centers face increasing cooling challenges due to increasing chip thermal design power and die size, along with the need to reduce energy consumption used for cooling. High performance cooling solutions that maintain a low chip junction temperature are needed to ensure electronics reliability. This work develops an ultra-low thermal resistance and low pressure drop 75 mm × 75 mm cold plate, intended for next-generation electronics cooling. The cold plate features an array of diamond-shaped pin fins and integrated copper tungsten heat spreader, selected for its low coefficient of thermal expansion which reduces thermomechanical deformation and allows for closer integration of the cold plate with silicon dies. Starting with 300 candidate designs, three-dimensional computational fluid dynamics simulations predict the thermal-hydraulic performance of cold plate subsections. The highest performing geometries are evaluated with high fidelity simulations. Four cold plates are manufactured for experiments: three with diamond-shaped pin fins and one with straights fins for comparison purposes. The cold plates are fabricated from copper-tungsten (CuW), copper (Cu), or aluminum-silicon-magnesium alloy (AlSi10Mg). The diamond-shaped pin fins achieve a roughly 15 % lower thermal resistance compared to the conventional straight fin microchannel. The highest performing design achieves a chip-to-coolant (including thermal interface material) thermal resistance of 9.0 K/kW in CuW and 6.9 K/kW in Cu under a 1 kW heat load with an inlet-to-outlet pressure drop of 9.0 kPa and water as the working fluid. This work demonstrates ultra-low thermal resistance and pressure drop cold plates for large die, high heat load applications, and shows that CuW is an attractive cold plate material for improved reliability in next generation data center cooling.

Coefficient of thermal expansion↗

VIPIR: A High-Throughput Drop-Weight Impact Instrument for Imaging the Initiation and Propagation of Reactions in Energetic Materials

Characterizing the handling safety and sensitivity of explosives has been a challenging area of study for over 60 years. Historically one of the most accessible and widely utilized experiments has been the drop-weight impact test, which involves dropping a weight on a small sample sandwiched between two anvils. Because this experiment generally only utilizes sound thresholds to determine whether or not a sample reacted, the physical and chemical properties governing sensitivity remain convolved. Better understanding of chemical and material characteristics is needed to give the chemistry and engineering communities a predictive tool to determine the handling sensitivity of explosives prior to pursuing expensive and potentially hazardous synthesis and formulation operations. Here, we are developing a high throughput drop tower instrument capable of imaging the deformation and flow of energetic materials during impact and the resulting thermal ignition and propagation events. This instrument is based on previous designs but has been modified for higher throughput and tailorable modifications in the future. Herein, we present key design features that enable high-speed visible and thermal imaging of explosive initiation by sub-shock impacts, as well as preliminary results in which ignition sites were observed in an erythritol tetranitrate sample.

47 OTHER INSTRUMENTATION↗

Enhancement of mid-/high-Z impurity transport by continuous Li-granule dropping in a stellarator plasma

An enhancement of core impurity transport is observed in high-density plasmas of the stellarator large helical device, heated by neutral beam injection, when continuous lithium (Li) granule dropping is performed. In the reported experiments, in which the tracer-encapsulated solid pellet is employed to inject trace amounts of titanium (Ti) and molybdenum (Mo) into the plasma core, confinement times for these impurities are seen to reduce significantly when Li dropping is applied, this reduction being more notable for Mo. To gain some initial insight into these observations, simulations are performed using the drift-kinetic transport code SFINCS for the Mo case. These simulations indicate that, while neoclassical transport prevails for the main plasma components (electrons, majority ions, and low-Z impurities), the classical contribution appears dominant for transporting Mo impurities. In summary, this work reports the first experimental observation of the degradation of mid-Z and high-Z impurity confinement induced by the continuous dropping of Li granules into a high-density stellarator plasma. In the case of the Mo impurity, simulations suggest that classical transport is the key mechanism underlying the enhanced impurity transport.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

“Hybridizing heat-integrated 3D printed modules with mass manufacturable, low pressure drop fiber sorbents” (Final Report)

The overall objective of this proposal was to research, develop, and evaluate a modular direct air capture (DAC) system that is simple and scalable. This system was based on the adsorption of CO 2 into commercial polyamines supported by porous fiber sorbents, which can be produced at kilometer per hour scales using our pre-pilot spinning line. We have housed these fiber materials in novel 3D printed modular housing systems that provide easy-to-manufacture and localized heat integration and flow control. This hybridization of fiber sorbent technology with modular housing provided several advantages that led to lower air pressure drops, higher sorbent productivity, as well as ease of manufacturing and assembly unrivaled by existing and emerging heat integrated contactor designs. The modular housing was fabricated with the following features, at a minimum: (i) a tapered air intake to reduce pressure drop related to entrance effects, (ii) a structured network of heat transfer channels to enable localized cooling and heating during adsorption and desorption, respectively, and (iii) low pressure drop supports for the fiber sorbents. This hybrid manufacturing approach provides a facile method for taking fiber sorbents from lab scale to pilot scale as it dramatically simplifies the fabrication of heat integrated contactor structures.

42 ENGINEERING↗

Drop Tower Statement of Work

This document details the needs and requirements for a propulsion-assisted drop tower system (further referenced simply as Drop Tower) to perform hardware testing at Lawrence Livermore National Laboratory (LLNL). LLNL is managed and operated by Lawrence Livermore National Security, LLC (LLNS) for the Department of Energy (DOE). LLNL requires a robust testing platform that will allow for the characterization of interactions between objects of interest. The initial siting of the equipment will be located in an existing test facility (B191). When another test facility becomes online, the objective will be to move the test capability to the new facility as a final location (B132N). The Drop Tower will be a cornerstone capability for testing and model validation for LLNL interested programs.

42 ENGINEERING↗