Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “drop on demand”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Exploring impacts of electricity tariff on charging infrastructure planning: An activity-based approach

In the past decade, electric vehicles (EVs) have gained popularity for their efficiency and environmental benefits. Advances in battery technology and charging equipment have yielded long-range EVs and fast-charging. However, many major cities lack adequate charging infrastructure for daily EV use. This study addresses this gap by integrating activity-based modeling, charging behavior simulation, and charging infrastructure optimization. The research utilizes the POLARIS agent-based transportation model to accurately capture user activities, trip patterns, and traffic flows. Additionally, the study investigates the impact of fixed and spatiotemporal electricity rate distributions on optimal charging infrastructure deployment. The framework is applied to the Chicago regional area network and analyzed under various EV ownership scenarios. Further, the results reveal significant impacts of the charging pricing strategy on user decision-making and charging demand distribution. There is also a need for consistent pricing policies in charging infrastructure planning and operational phases to avoid drops in service quality.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Case Study: NREL Campus Chilled Water Storage Potential: Benchmark Datasets Development and Applications, Task 4 - Use Case Demonstration

The Benchmark Datasets Development and Applications project is a three-year collaboration between the National Renewable Energy Laboratory (NREL), Oak Ridge National Laboratory, Pacific Northwest National Laboratory, and Lawrence Berkeley National Laboratory. The project seeks to collect and curate high-resolution, well-calibrated time series of building operational and indoor/outdoor environmental data, which are crucial to understanding and optimizing building energy efficiency performance and demand flexibility capabilities as well as benchmarking energy algorithms. Project outcomes include approximately twelve high-fidelity building datasets, enhanced data representation tools, and four case studies to illustrate example applications. The goal of these case studies is to define and execute analyses that demonstrate how one or more datasets collected through this project can address a data gap or challenge historically faced by building stakeholders. This technical paper summarizes the findings of one of these case studies, in which we studied the operational efficiencies of the central cooling system at NREL. We looked at three years of data from the three chillers in the Field Test Laboratory Building (FTLB), from 2019 to 2021, to compare equipment operation and demand throughout the time period. Our analysis indicates that all three chillers are operating at or below the optimal loading conditions for most of the operation time, and thus there was no efficiency drop due to loading of the chillers at full capacity. Our recommendation is that no chiller capacity increase is needed; instead, the central plant could benefit from adopting advanced control logics for optimal sequencing of chillers during part load operations. Analysis of adding chilled water thermal storage to the central plant indicated 34% savings in demand cost and 24.5% savings in total cost (energy consumption and demand charge cost). The payback period is estimated to be 11-22 years with an assumed TES cost of $\$$100-$200 per ton. This case study shows how a selected dataset is used to solve a practical building problem - learning the operational status of its components, analyzing the effectiveness of a proposed new technique, and aiding decision-making for the building operations and maintenance team.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lifting and Dropping VMs to Dynamically Transition Between Time- and Space-sharing for Large-Scale HPC Systems

As HPC environments increasingly integrate with edge based systems, system architectures will need to handle a broader class of workloads and scheduling requirements. One result of this shift will be the need to simultaneously support bulk-synchronous parallel (BSP) and on-demand service based applications on the same infrastructure. This in turn will require that future resource management approaches utilize both space-shared as well as time-shared resource scheduling strategies. In this work we introduce the concept of "VM-lifting'' (and its inverse "VM-Dropping'') which allows dynamically switching an HPC workload between space-shared and time-shared scheduling regimes. Our work targets co-kernel based HPC system software environments, in which multiple specialized OS kernels execute natively on dedicated physical resource partitions inside a single compute node. With VM-lifting, a native co-kernel can be migrated at runtime to and from locally hosted Virtual Machine Environments due to changing scheduling requirements of the node. This allows an HPC node to be dynamically (re-)configured as either a time-shared Infrastructure-as-a-Service (IaaS) resource or a dedicated space shared resource based on the current workload demands. We have implemented this approach in the context of the Hobbes Exascale System Software stack and have demonstrated that a node can be reconfigured with minimal impact on the running applications.

Gordon, Nick↗

Active tungsten expulsion in ELM-absent H-mode plasmas via on-demand ELM triggering with lithium granule injection

Lithium granules gravitationally injected into the upper X-point region demonstrated on-demand edge-localized modes (ELM) triggering in otherwise ELM-suppressed H-mode plasmas on the Experimental Advanced Superconducting Tokamak. Sub-mm lithium granules dropped into enhanced D-alpha H-mode plasmas achieved a high triggering efficiency, while enabling ELM frequencies from several to hundreds of hertz. Core radiation from heavy impurities, dominated by W, was reduced by up to 60%, and the normalized energy confinement increased by up to 30%. At low injection frequencies, ELMs of substantially reduced size compared to spontaneous type-I ELMs were observed. At high injection frequencies, a transition to a mixed ELM phase occurred, characterized by intermittent larger ELMs and suppression of the quasi-coherent mode, achieving the most significant W reduction and energy confinement improvement. These results highlight a promising pathway for active W control via controlled, small ELMs in long-pulse, high-performance scenarios.

EDA H-mode↗

Fifty years of lithium-ion batteries and what is next?

Here, the first rechargeable lithium batteries were built 50 years ago, at the same time as the Materials Research Society was formed. Great strides have been made since then taking a dream to domination of portable energy storage. During the past two decades, the demand for the storage of electrical energy has mushroomed both for portable applications such as for the iPhone and electric vehicles and for more than 1 GWh grid applications. As storage and power demands have increased, the batteries have evolved with their chemistries being pushed to the limits. This has resulted in the energy densities almost doubling and the cost dropping by more than an order of magnitude. However, the present electrochemical systems are still too costly to penetrate major new markets, still higher performance is required, and environmentally acceptable and sustainable materials are required.

25 ENERGY STORAGE↗

CTF Improved Drag Model and Flow Regime Transition Criteria

The demand for accurate prediction of two-phase flow behavior in a boiling water reactor (BWR) requires a comprehensive understanding of flow regime, void fraction, heat transfer, and pressure drop. The CTF subchannel code, which is used for the Thermal/Hydraulic (T/H) solution in the Consortium for Advanced Simulation of Light Water Reactors (CASL)-developed Virtual Environment for Reactor Application (VERA) core simulator, is being further developed for BWR applications. In support of this goal, the present work highlights some of the two-phase closure model developments towards improving the CTF void fraction prediction, especially for subcooled boiling. The drift-flux approach has been well-developed for upward dispersed two-phase flows and proven to be accurate in predicting void fraction in bubbly and slug flow regimes. In this work, these kinematic constitutive relations for the drift-flux velocity have been implemented into CTF to describe the interfacial drag of bubbly flow as an alternative to the existing model for better void fraction prediction. The success of these constitutive relations also relies on a good flow regime map that accounts for flow conditions and channel geometry. A more reliable flow regime transition criteria that account for the flow condition has also been implemented in this study for modeling the flow regime transition criteria. The newly implemented models are shown to give improved void fraction predictions in comparison to experimental data.

Hizoum, Belgacem↗

Water and Climate Impacts on ERCOT Long-Term Systems Assessment

Water and climate change pose many potential challenges to the electric power system. Substantial water is withdrawn every day to support thermoelectric power generating unit operations, and changes to water supply have the potential to affect generation dispatch. Climate change can accelerate growing demand for electricity, which can necessitate additional generating capacity, often in locations with limited water supply. Drought conditions also threaten thermoelectric power plant operations due to streamflow and reservoir levels dropping below intake structures, or water temperatures exceeding a power plants' permitted operating conditions. Here we explore how future climate change might influence decisions related to electricity capacity expansion planning in Electric Reliability Council of Texas (ERCOT) using a multi-model framework. Specifically, water resource modeling is used to simulate climate impacts on the future water supply for thermoelectric and hydropower generation for four future climate projections. Separately, temperature impacts on electricity load are evaluated for these scenarios. These climate impacts are applied to five alternative electricity futures in an electricity capacity expansion model that projects future generation and transmission capacity additions in ERCOT. Results indicate that climate has a measurable influence on future generation and transmission capacity needs, with temperature-driven increases in peak and average load resulting in 5-15 GW additional generating capacity and up to 1 GW additional transmission capacity. Additional capacity is a diverse mix of PV, natural gas, and wind, depending on the makeup of economic, policy and technology assumptions. Climate impacts increase total system costs 2-5%, while the marginal cost of energy and emissions are not affected substantially by climate change effects.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Climate Impact on CO2 Capture Efficiency and Levelized Cost of Liquid solvent-based DAC (Direct Air Capture) System

The transition towards net-zero emission poses economic, technical, and political challenges for the commercial-scale deployment of CO2 removal technologies by 2050. The opportunities for large-scale deployment will largely depend on the distinctive conditions found in the different locations of the world such as energy cost, carbon intensity of energy source, construction, transportation, and weather conditions. In this work, we focus on one of the promising negative emission technology, DAC (Direct Air Capture), and its response to different weather conditions. This work presents two potential operation scenarios: (i) natural gas standalone, (ii) grid electricity connected DAC plant. For the first time, we investigated the influence of temperature and RH (relative humidity) of the air on liquid-based DAC system and its response to carbon capture efficiency and levelized cost of carbon capture with operational sensitivity analysis. It is observed that the overall energy demand decreases from 11.1 to 8.3 GJ/ton-CO2 as the CO2 capture rate increases from 40 to 85%. We observed that a CO2 capture rate of 75% is only possible above 17°C even at 90% RH and this drops tremendously at lower temperatures. It is also observed that water evaporation in the air contactor is highest at dry and low RH as expected. The sensitivity analysis showed that weather conditions are insensitive to CO2 capture efficiency for the liquid-solvent based DAC plant for both scenarios. In addition, higher CO2 capture efficiency is achievable from lower upstream methane emissions and carbon intensity of grid electricity (for grid-connected scenario). Lastly, the levelized cost of natural gas standalone scenario varies from 239.7 to 408.8 $/t-CO2 is sensitive to temperature conditions more than relative humidity and compared to electricity grid-connected scenario, from 265.3 to 440.1 $/t-CO2.

An, Keju↗

Multiplexing core & sheath extrusion system development for additive manufacturing for inner-bead multi-material capability

Single-feed polymer extruders are widely used in large-format additive manufacturing (AM) systems; however, the increasing demand for multi-material functionality within a single part has driven significant innovation in this field. One approach involves robotic pick-and-place operations, while another explores mechanical switching of feed lines during extrusion. Although robotic pick-and-drop systems offer flexibility, they introduce longer layer times during material changes, which can negatively affect the structural integrity of the part. On the other hand, mechanical feed switching causes delays in material transitions, as the existing material must be flushed before the new material emerges from the nozzle. This poses particular challenges for smaller or more intricate parts. In this study we are developing a unique multiplexing extrusion system with core & sheath nozzle that combines two extruders via co-extrusion. This allows for a unique inside and outside inner-bead (i.e., within the same bead) multi-material capability. We believe that this technology will allow for combining neat and filled materials, ductile and stronger materials, and many other combinations to address the problems aforementioned above and disrupt the AM technology creating new opportunities and opening application areas.

Tekinalp, Halil [ORNL]↗

Nitrogen Deposition Weakens Soil Carbon Control of Nitrogen Dynamics Across the Contiguous United States

ABSTRACT Anthropogenic nitrogen (N) deposition is unequally distributed across space and time, with inputs to terrestrial ecosystems impacted by industry regulations and variations in human activity. Soil carbon (C) content normally controls the fraction of mineralized N that is nitrified ( ƒ nitrified ), affecting N bioavailability for plants and microbes. However, it is unknown whether N deposition has modified the relationships among soil C, net N mineralization, and net nitrification. To test whether N deposition alters the relationship between soil C and net N transformations, we collected soils from coniferous and deciduous forests, grasslands, and residential yards in 14 regions across the contiguous United States that vary in N deposition rates. We quantified rates of net nitrification and N mineralization, soil chemistry (soil C, N, and pH), and microbial biomass and function (as beta‐glucosidase (BG) and N ‐acetylglucosaminidase (NAG) activity) across these regions. Following expectations, soil C was a driver of ƒ nitrified across regions, whereby increasing soil C resulted in a decline in net nitrification and ƒ nitrified . The ƒ nitrified value increased with lower microbial enzymatic investment in N acquisition (increasing BG:NAG ratio) and lower active microbial biomass, providing some evidence that heterotrophic microbial N demand controls the ammonium pool for nitrifiers. However, higher total N deposition increased ƒ nitrified , including for high soil C sites predicted to have low ƒ nitrified , which decreased the role of soil C as a predictor of ƒ nitrified . Notably, the drop in contemporary atmospheric N deposition rates during the 2020 COVID‐19 pandemic did not weaken the effect of N deposition on relationships between soil C and ƒ nitrified . Our results suggest that N deposition can disrupt the relationship between soil C and net N transformations, with this change potentially explained by weaker microbial competition for N. Therefore, past N inputs and soil C should be used together to predict N dynamics across terrestrial ecosystems.

Nieland, Matthew A. [Stockbridge School of Agricul↗

Hydrogen Detection Strategies to Support H2@SCALE - The NREL Sensor Laboratory

Hydrogen represents a major pathway to decarbonize and stabilize the national and international energy industry and select manufacturing markets. To facilitate the development of hydrogen markets, the US Department of Energy initiated H2@Scale to bring together stakeholders to advance affordable hydrogen production, transport, storage, and utilization to increase revenue opportunities in multiple energy sectors. One major impediment to hydrogen implementation is cost. To expedite the use of hydrogen in energy and other markets, the United States announced in 2021 the Hydrogen Shot, which seeks to reduce the cost of clean hydrogen by 80% to $1 per 1 kilogram in 1 decade ("1 1 1"). As the cost of hydrogen drops, new applications will emerge that will require unique configurations of existing equipment and infrastructure, and eventually lead to advances in the generation and utilization of hydrogen. As the hydrogen economy expands, sensors and detection methods will need to adapt to changing infrastructure demands to address the primary targets of health & safety, emissions monitoring, and process control. The NREL Sensor Laboratory is playing a pivotal role in advancing the use of hydrogen sensors and detection methodologies in each of these categories to support DOE's mission for safe and efficient utilization in emerging markets. Health & safety monitors are required to ensure that operators and facilities can react to unintended hydrogen releases, either as GH2, LH2, or as a constituent of blends (e.g., natural gas or ammonia). Current detection methodologies focus on safety applications to detect near its lower flammable limit (4 vol %), and typically include point sensors in applications such as fixed or mobile detectors (e.g., personal gas monitors). Methodologies amenable for area detection include acoustic, emerging optical imaging methods, and flame detectors. Comparable detection strategies can be utilized for emissions monitoring and quantization, however few methods can simultaneously cover both low (emissions) and high (health & safety) levels. Deployment of emission level detectors will be required to 1) reduce product loss through small but potentially significant leaks from an environmental or cost perspective, 2) reduce downtime of high demand systems by early identification of eminent system failures (leaks through pump or compressor seals indicative of impending failure), and 3) address potential emission monitoring requirements that may be set by regulating bodies. The first two points should be adopted by industry to reduce the cost-of-goods-sold. The third main category for hydrogen detection relates to process control and may be advantageous for many existing applications. Two main applications are emerging. For example, the purity requirements for hydrogen that is dispensed from refueling systems for hydrogen fuel cell electric vehicles (FCEV) is rigorously regulated by the Standard SAE J2719, which prescribes maximum allowable levels of multiple impurities in the hydrogen fuel and must be verified by a regulatory body. Hydrogen contaminant detectors (HCD) integrated to the fueling station can assure this compliance. HCDs must be able operate in 100% H2 backgrounds and be able to distinguish between multiple contaminants at low ppm to low ppb levels. Secondly, as a strategy to decarbonize the natural gas grid, there are proposals to blend hydrogen with natural gas. This blending will affect transport applications (pipeline infrastructure), stationary combustion systems (turbines), and consumer and commercial appliances. In the short-term, hydrogen levels up to 20% are proposed. Variations in the hydrogen level can have dramatic impact on the combustion process and on the potential response of safety sensors. These mixtures may be regulated so that the concentration at a delivery point must be monitored with high precision. However, routine maintenance may introduce background gases such as ambient air (with water) or maintenance gases (introduced with welding processes or adhesive outgassing.) Therefore, the detection methodology must be robust enough to recover or respond to various contaminants. Several reviews can be found in literature addressing sensing and detection technologies, including their limitations and applications. However, for most applications, limitations can be alleviated by combining various detection techniques either through system integration or implementation of machine learning methods (artificial intelligence). In this presentation, we will discuss several applications, highlight their current approach for hydrogen detection, and suggest detection strategies to supplement their limitations.

ENERGY STORAGE,HYDROGEN↗

Analysis and mitigation of parasitic resistance effects for analog in-memory neural network acceleration

To support the increasing demands for efficient deep neural network processing, accelerators based on analog in-memory computation of matrix multiplication have recently gained significant attention for reducing the energy of neural network inference. However, analog processing within memory arrays must contend with the issue of parasitic voltage drops across the metal interconnects, which distort the results of the computation and limit the array size. This work analyzes how parasitic resistance affects the end-to-end inference accuracy of state-of-the-art convolutional neural networks, and comprehensively studies how various design decisions at the device, circuit, architecture, and algorithm levels affect the system's sensitivity to parasitic resistance effects. Here, a set of guidelines are provided for how to design analog accelerator hardware that is intrinsically robust to parasitic resistance, without any explicit compensation or re-training of the network parameters.

97 MATHEMATICS AND COMPUTING↗

The Convergence of Vehicle Electrification and Automation - Enabling Sustainable Automated Mobility Districts

The transportation industry is entering a new frontier with three major simultaneous transformations: electrification, automation, and on-demand services. All three directly affect the same spaces of vehicle technology, infrastructure, and system operational performance. Further, each area of change adds its own driving forces of complexity to the others' design challenges. This paper explores these transformations, framing the implications for vehicle technology and infrastructure and their impact on operating concepts and strategies, which in turn impact the sustainability of the transportation infrastructure in the built environment. Specifically, this paper examines battery-electric vehicles operating in a fully automated fleet within an "automated mobility district" (AMD) setting with multiple on-demand services. From this examination, the paper assesses the implications for transportation electrification, comparing and contrasting traditional fixed-route services with those of on-demand transit and automated transit networks, including the trade-offs between vehicle range (battery capacity), charging parameters, power availability, and operations predictability with respect to policy and infrastructure configurations. The paper also addresses the configuration and management of boarding and alighting zones (also called pickup and drop-off zones), and the need for complementary infrastructure intelligence at intersections and curbs. Finally, conclusions are drawn with respect to the system integration and analysis needs for AMDs regarding resilience and sustainability of mobility infrastructure.

ADVANCED PROPULSION SYSTEMS↗

Performance Assessment of a Dual-purpose HP-TES for a Typical Year Comparing Different Climate Zones

Complete electrification of heating and cooling systems in the United States would overload the existing electrical grid. To this end, recent research efforts have focused on energy storage as one way to reduce ever-increasing peak electricity demands. One such technology is heat pump integrated thermal-energy storage (HP-TES) systems, which can enable load-shifting and reduce demand during peak hours. In this work, a Modelica model of a 4-Ton, dual-mode (heating and cooling) HP-TES system using a room-temperature phase-change material (PCM) integrated through a secondary hydronic loop was developed and simulated for a typical meteorological year in Riverside, CA (ASHRAE Climate Zone 2B), and Chicago, IL (ASHRAE Climate Zone 5A), for a DOE small office prototype building. The COP improvement and demand reduction were analyzed during the time-of-use peak hours along with the required recharge cycle energy demand. A typical summer in Riverside, CA resulted in model-predicted peak COP increases of 50 – 100% compared to the baseline heat pump, especially at higher outdoor temperatures, coupled with maximum peak energy reductions of 22%. During shoulder and winter season simulations, heating energy savings were higher as outdoor temperatures dropped below the PCM phase change temperature. For Chicago, IL, backup heating was necessary to meet the required system capacity for very cold ambient conditions, resulting in winter peak energy savings between 16 – 60% when accounting for backup heating requirements. The recharge energy was found to be mostly below the baseline HP energy during the peak. With improved component selections and controls, the recharge energy may be reduced. The outcomes from the simulations can provide first-order estimates for potential peak energy savings, challenges, and required controls in any location before conducting any field testing.

25 ENERGY STORAGE↗

A New Era for Solar and Storage: Partnering for Continued Success

Solar energy has grown faster than experts projected. Energy storage technologies are poised to repeat that success, enabling a partnership to keep the lights on even after the sun sets. As current impacts and growing threats of climate change become more visible and the world accelerates efforts to adopt new clean-energy technology, electricity generation from solar and wind is playing an increasing role in the energy system. However, it can be confusing - we hear that solar has great potential, but we also hear that solar and wind are too small to make a meaningful difference, providing just 3% and 6% of the world's electricity in 2020, respectively (1). What is the reality and what can we expect in the coming years? This article focuses on solar, but wind has an equally impressive and interesting story. This article reviews how prices for solar have dropped dramatically and deployment has increased correspondingly to the point where solar is almost half of the new electricity generating capacity being installed globally today. It shows how solar-generated electricity has grown to the point where we need to pair it with storage or other strategies for balancing electricity supply and demand. The article also explores how lithium-ion batteries are replicating solar technology's big success and discusses new storage technologies that are being developed.

14 SOLAR ENERGY↗

High-Fidelity Modeling of Curbside Driving Behavior in SUMO: Preprint

Recent advances in mobility technologies have considerably increased the need for curbside use and congestion at curb-lanes. At airports and in dense urban centers, the growing adoption of Transportation Network Companies (TNCs), such as Uber and Lyft, has led to an increase in curbside traffic due to the reduction in the use public transit and other shared modes. In dense city areas, the curbside demand and congestion were further augmented by the growing use of e-commerce, which requires home-delivery of goods. To model vehicles' curbside interactions realistically, there is a need for high-fidelity simulation models that can represent the complex interplay of vehicles as they complete pick-up or drop-off trips. Vehicles' curbside behaviors are usually not modeled with high-fidelity in microscopic simulators such Simulation of Urban of Mobility (SUMO). This paper presents such a high-resolution model for vehicle curbside behavior in SUMO, using SUMO's Traci interface. Simulations results demonstrate that the improved curbside behavior captures vehicles' curbside maneuvering more accurately than the default SUMO curbside model, and increases the curbside utilization and capacity.

ADVANCED PROPULSION SYSTEMS↗

Improving chiller performance and energy efficiency in hydrogen station operation by tuning the auxiliary cooling

In a hydrogen station that operates with direct fueling through the use of a 700 bar boost compressor, the outlet hydrogen temperature can significantly increase, stressing the chiller system. Here, this paper evaluates improvements that can be made to the auxiliary cooling system integrated with the compressor. Both theoretical modeling and experiments were performed at Cal State LA Hydrogen Research and Fueling Facility. The findings suggest that adjusting the auxiliary closed-loop cooling system from 15 °C to 10 °C reduced the station energy consumption and decreased the demand on the station chiller that needed to provide –20 °C hydrogen at the hose. The overall energy consumption for a single fueling reduced by between 2.86 and 9.43% for the set of experiments conducted. After the temperature of the closed-loop cooling system was reduced by 5 °C, the boost compressor outlet temperature dropped from 46-50 °C–40 °C and consequently at the hose the hydrogen temperature declined by 3 °C. Results were scaled up with a forecast on the number of daily refueling events. With a low number of daily fuelings, the proposed set-up showed a minor influence on the overall station energy consumption. However, the benefits were more pronounced for a connector station with sales at 180 kg/day, where the energy efficiency improved by between 1.4 and 5.5%, and even more so for a higher capacity station at 360 kg/day, where the improvement was between 2.9 and 8%.

08 HYDROGEN↗

The impact of climate on solvent-based direct air capture systems

Direct air capture (DAC) is increasingly seen as a critical technology to reach mid-century net-zero targets and limit climate change to well below 2 °C. While the commercialization of DAC technologies is being pursued by numerous companies, there remains remarkably little information on their performance under “real-world” conditions. In this paper, for the first time, we investigate the influence of temperature and relative humidity of air on the CO 2 capture rate at the air contactor, overall energy requirement, CO 2 capture efficiency, and levelized cost of liquid-solvent based DAC systems. We observe that the overall energy demand decreases from 11.1 to 8.3 GJ/tCO 2 as the CO 2 capture rate increases from 40 to 85 % and that high capture rates can only be achieved in hot and humid climate conditions. We observe that a CO 2 capture rate of 75 % is only possible above 17 °C and 90 % relative humidity, and this drops dramatically at lower temperatures. It is also observed that water evaporation in the air contactor is highest at dry and low relative humidity, as expected. The sensitivity analysis showed that CO 2 capture efficiency is relatively insensitive to climate conditions for the liquid-solvent based DAC plant. Lastly, the levelized cost of natural gas standalone scenario varies from $240/tCO 2 to $409/tCO 2 , and this is more sensitive to temperature than relative humidity. The levelized cost of the natural gas stand-alone case is between 7 % and 10 % lower than that of an electric grid-connected case across all climate conditions.

54 ENVIRONMENTAL SCIENCES↗