Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “droop operation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Numerical Oscillation Prevention for PV Inverter Controllers in Quasi-Steady-State Simulators

Droop-based PV inverter control methods are popular for preventing overvoltage in low voltage networks with high installations of PV solar. Quasi-steady-state simulators (QSTS) can be used to reduce the computational burden of conducting long-term techno-economic analyses of such PV inverter controllers. If dynamic models for droop-based controllers are directly implemented in QSTS, numerical oscillation occurs and the controllers fail to converge to their steady-state operation. In this paper, a power network sensitivity-based algorithm is proposed for preventing numerical oscillation while implementing active and reactive droop-based PV inverter controllers in quasisteady state simulation tool (e.g. in GridLAB-D). Convergence of the sensitivity-based algorithm is verified using a typical radial distribution feeder. It is found that all three controllers reached converged state in less than 15 iterations.

GridLAB-D, PV inverter control, quasi-steady-state↗

Generator Frequency Response Droop Monitoring Tool

Monitoring and analyzing the frequency response performance of power generation units is essential for maintaining reliable and secure power system operation. To address this need, an automation tool has been developed to provide a pipeline for processing historical power plant generation data, including large-scale SCADA archives. The tool performs end-to-end processing, including event detection, frequency response (FR) analysis in accordance with NERC standards, and estimation of speed governor droop characteristics. The tool is designed with a modular architecture, allowing individual components of the workflow to be extended, customized, or deployed independently. In addition, the tool provides an API that enables seamless integration with other production systems and operational analytics platforms.

Etingov, PavelV [Pacific Northwest National Labora↗

Investigation of Superluminescent Diodes for Smart Lighting Systems. Final Report

The solid-state lighting ecosystem has evolved very rapidly over the last few years, with significant improvements in the technical performance of light-emitting diodes (LEDs) and the commoditization of LED-based lighting fixtures. As the performance of conventional lighting products begins to saturate, there is growing market interest in “Lighting as a Service” applications that will leverage advanced systems to impart new functionalities to lighting and improve energy efficiency, human health, and productivity. These “Smart Lighting” systems will include high-performance light sources, specialized sensors, and dynamic controls to deliver high quality, energy efficient, color tunable lighting with customized spatial light delivery and integrated visible light communication capability. To achieve these capabilities, smart lighting systems will place greater demands on the performance of light sources. Highly efficient sources with additional functionalities compared to conventional LEDs, such as small form factor, large modulation bandwidth, and spatially coherent output beams, will be required. While laser diodes have been proposed as potential sources for smart lighting systems, they also exhibit several properties that pose challenges, such as temporal coherence, extremely high spatial coherence, and ultra-narrow linewidths. To address these issues, we propose an investigation of an alternative device architecture known as a superluminescent diode (SLD). SLDs are similar in form to ridge laser diodes and share many of the same characteristics, such as stimulated emission operation, spatially coherent output, small form factor, and the potential for large modulation bandwidth. However, the operating principle for SLDs is distinct from laser diodes in that SLDs lack a strong cavity feedback mechanism, resulting in spatially coherent but temporally incoherent light output. Thus, SLDs may address the issues with laser diodes for lighting, while simultaneously maintaining some of the desirable characteristics of both laser diodes and LEDs. The objectives of this proposal are to design, grow, and fabricate blue (450 nm) SLDs on polar c-plane and nonpolar m-plane free-standing GaN substrates, and to evaluate their potential as sources in smart lighting systems through basic device characterization and detailed investigations of their efficiency droop and modulation bandwidth. The primary scientific aims of this work are to understand the fundamental role of optical gain in the superluminescent (non-lasing) regime on efficiency droop and modulation bandwidth in III-nitride emitters and to understand the effects of higher optical gain on SLD performance by comparing polar c-plane and nonpolar m-plane SLDs. The University of New Mexico (UNM) will collaborate with Sandia National Laboratories (SNL) and the Center for Integrated Nanotechnologies to design, fabricate, grow, and characterize the SLDs. UNM will perform the design and epitaxial growth, while SNL will focus on the fabrication and device characterization. The novelty of the proposed work includes the first comprehensive theoretical and experimental investigations of efficiency droop and the first investigation of modulation bandwidth in GaN-based emitters operating in the superluminescent regime. Moreover, the comparison of c-plane and m-plane SLDs will enable the first analysis of the effects of higher optical gain on the device performance. The development of high-performance GaN-based SLDs may enable efficiency gains and improved functionality in next-generation smart lighting systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Isochronous Architecture-Based Voltage-Active Power Droop for Multi-Inverter Systems

This article proposes an isochronous architecture for parallel inverters with only voltage-active power droop (VP-D) control for improving active power sharing as well as plug-and-play of multi-inverter-based distributed energy resources (DERs). The isochronous framework obviates the need for an explicit regulation of the frequency while allowing for sharing of reactive power. The article shows that the detrimental effects of circulating currents between inverters can be addressed in the framework developed. The isochronous architecture is implemented by employing a GPS to disseminate clock timing signals that enable the microgrid to maintain the nominal system frequency. Small signal eigenvalue analysis of a Multi-inverter Microgrid system near the steady-state operating point is presented to evaluate the system stability. Moreover, unlike traditional droop-based methods, the isochronous strategy lends itself to analytical guarantees which are developed in the article. Furthermore, the effect of delays in receiving GPS clock signals by an inverter is experimentally characterized and an inverter isolation mechanism is proposed that disconnects inverters facing large GPS communication delays. Hardware experiments on an 1.2 kVA-prototype and controller-hardware-in-the-loop validation on the CIGRE distribution network are conducted to demonstrate the effectiveness of the proposed architecture towards active and reactive power sharing between inverters with load scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dispatchable Virtual Oscillator Control for Decentralized Inverter-Dominated Power Systems: Analysis and Experiments: Preprint

This paper presents an analysis and experimental validation of dispatchable virtual oscillator control (dVOC) for inverter-dominated power systems. dVOC is a promising decentralized control strategy that requires only local measurements to induce grid-forming behavior with programmable droop characteristics. It is dispatchable -- i.e., the inverters can vary their power generation via user-defined power set-points and guarantees strong stability. To verify its feasibility, a testbed comprising multiple dVOC-programmed inverters with transmission line impedances is designed. With an embedded synchronization strategy, the dVOC inverters are capable of dynamic synchronization, black start operation, and transient grid voltage regulation with dynamic load sharing, and real-time-programmable droop characteristics for backward compatibility. All these features are experimentally verified.

14 SOLAR ENERGY↗

Soft Actor Critic Based Volt-VAR Co-optimization in Active Distribution Grids

Modern distribution networks are undergoing several technical challenges, such as voltage fluctuations, because of high penetration of distributed energy resources (DERs). This paper proposes a deep reinforcement learning (DRL)-based Volt VAR co-optimization technique for reducing voltage fluctuations as well as power loss under high penetration of DERs. In addition, the proposed approach minimizes the operational cost of the grid. A stochastic policy optimization based soft actor critic (SAC) agent is proposed to configure the optimal set-points of the reactive power outputs of the inverters. The performance of the proposed model is verified on the modified IEEE 34- and 123-bus systems and compared with a base case scenario with no reactive supply by inverters, and a local droop control approach. The results demonstrate that the proposed framework outperforms the conventional droop control method in improving the voltage profile, minimizing the network power loss, and reducing grid operational cost.

—Distribution grids, deep reinforcement learning, ↗

Fairness-Aware Distributed Energy Coordination for Voltage Regulation in Power Distribution Systems

The accelerating deployment of solar photovoltaics into low-voltage distribution networks can cause reverse power flow and overvoltage problems. However, if coordinated properly, the real and reactive power flexibility of these resources enables distribution operators to manage their networks more efficiently. Existing literature is rich in droop-based control (Volt-Watt and Volt-VAr) and optimization-based distributed energy coordination for four-quadrant control of photovoltaics to prevent overvoltage issues. While optimal coordination can effectively mitigate overvoltage, it tends to treat resources at sensitive parts of the grid unfairly. Here, to address this concern, we propose a distributed optimal power flow formulation that incorporates fairness in curtailing photovoltaic generation and utilizes the reactive power capability of smart inverters. The proposed distributed formulation allows for scalable resource aggregation that can be leveraged to achieve fairness within a certain segment of the grid and/or fairness across the entire network. Fair curtailment of photovoltaic systems is demonstrated with aggregation at each of two layers in a distribution network: 1) area-level fairness and 2) feeder-level fairness. To explore the trade-off between fairness and optimal utilization, the fairness-aware control actions are compared against the performance of a centralized controller that aims to maximize the aggregate PV generation without incorporating fairness. Simulation results show that introducing area-level fairness increased curtailment by 0.0101 percentage points and feeder-level fairness increased curtailment by 0.0458 percentage points compared to a fairness-agnostic control.

Poudel, Shiva↗

Autonomous Microgrid Restoration Using Grid-Forming Inverters and Smart Circuit Breakers

The proliferation of distributed inverter-based resources (IBRs) raises the questions if these IBRs can be used to blackstart microgrids and distribution feeders after major outages. In this paper, we propose and evaluate an autonomous microgrid restoration concept using grid-forming (GFM) IBRs and smart circuit creakers (SCBs). The concept is first explored in simulation platform and then a hardware testbed containing actual GFM inverters is developed to demonstrate these functionalities. A combination of dispatchable virtual oscillator control (dVOC) and droop-based control schemes have been designed for GFM inverter controls in the software simulations and hardware testbed. Subsequently, operation of SCBs using two distinct principles have been demonstrated that can restore or connect portions of the network.

black start↗

A Secondary Control Framework for Microgrid Interoperability With Vendor-Agnostic Grid-Forming Units: Design, Implementation, and Demonstration via Large-Scale Hardware Setup

The reliable operation of islanded microgrids increasingly depends on secondary controls that restore voltage and frequency to nominal values and ensure accurate active and reactive power sharing. Centralized secondary control architectures achieve high accuracy through global coordination at the cost of single-point failures and limited scalability compared with decentralized/distributed approaches. But a critical gap remains in addressing the interoperability and vendor-agnostic operation of secondary controls in real-world microgrids where heterogeneous diesel generator(s) and grid-forming (GFM) inverter(s) from multiple manufacturers always coexist. Practical and vendor-agnostic interoperability guidelines for the secondary control architecture of microgrids with multiple GFM units have not yet been developed; therefore, this paper proposes an interoperable and vendor-agnostic secondary control framework that operates seamlessly across GFM units from different vendors without relying on proprietary controls and protocols, hardware, or lock-ins. The framework leverages existing communication infrastructures (e.g., Modbus TCP/IP) to enable cost-effective deployment while addressing practical challenges, such as packet loss and quantization errors. Mitigation strategies-including data averaging, situational event-triggered control, and finite-iteration execution-are introduced to enhance reliability under real-world conditions. A generalized modeling and design framework is also presented, supported by robustness analysis to demonstrate independence from vendor-specific implementations. The proposed framework is validated through a large-scale hardware demonstration using a 3-$\phi$, 480-V, 60-Hz, 713-kVA laboratory hardware microgrid involving a heterogeneous diesel generator and multiple GFM inverters, showcasing its effectiveness in achieving stable voltage and frequency restoration and accurate power sharing under practical constraints. The results highlight the framework's potential as a scalable and practical solution for next-generation microgrids requiring openness, standard framework, and interoperability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Small-Signal Stability Conditions for Inverter-Based Unbalanced Microgrids

The proliferation of inverter-based generation and advanced sensing, controls, and communication infrastructure have facilitated accelerated deployment of microgrids. A coordinated network of microgrids can maintain reliable power delivery to critical facilities during extreme events. Low-inertia offered by the power-electronics–interfaced energy resources, however, can present significant challenges to ensuring stable operation of the microgrids. In this work, distributed small-signal stability conditions for inverter-based microgrids are developed that involve the droop-controller parameters and the network parameters (e.g. line impedances, loads). The distributed closed-form parametric stability conditions derived in this paper can be verified in a computationally efficient manner, facilitating reliable design and operations of networks of microgrids. Dynamic phasor models have been used to capture the effects of electromagnetic transients. Furthermore, numerical results are presented, along with PSCAD simulations, to validate the analytical stability conditions. Effects of design choices, such as the conductor types, and inverter sizes, on the small-signal stability of inverter-based microgrids are investigated to derive useful engineering insights.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Equivalent-Circuit Models for Grid-Forming Inverters under Unbalanced Steady-State Operating Conditions: Preprint

Positive- and negative-sequence equivalent-circuit models are put forth to capture the operation of grid-forming (GFM) inverters in unbalanced steady-state operating conditions acknowledging the impact of current limiting. The particular control architecture examined adopts droop control (for primary control), nested inner-current and outer-voltage control (in the stationary reference frame), and it is adaptable to two different types of current limiting (current-reference saturation and virtual-impedance limiting). We anticipate the proposed models to be of interest in modeling, analysis, and simulation of GFM inverters in unbalanced settings that may arise, e.g., in the face of faults. Validation of the equivalent-circuit models is pursued via comparison with full-order electromagnetic-transient (EMT) simulations for representative balanced and unbalanced faults.

equivalent-circuit models↗

Solar PV and BESS Plant-Level Voltage Control and Interactions: Experiments and Analysis

In real world operation, low-frequency oscillations associated with plant-level voltage control of inverter-based resources (IBRs) have been a concern of grid operators. Here, this research aims to demonstrate and analyze the effect of plant-level voltage control on system stability and potential interactions among IBRs. The experiment results of a 13.2-kV system interconnected with two IBRs—a 1-MW battery energy storage system (BESS) and a 430-kW solar photovoltaic (PV) plant—are presented. Both 0.5-Hz and 3-Hz oscillations become visible at certain conditions. The phenomenon is further explained by use of a feedback system consisting of the plant-level droop control and the effect of reactive power or var injection on voltage. The main components of the block diagram are obtained via frequency scan measurements. The analysis offers an understanding of the main contributors and other influencing factors of the 3-Hz and 0.5-Hz modes. It also reveals the role of the volt-var droop gain, the low-pass filter time constant, and the system impedance in stability.

14 SOLAR ENERGY↗

Single-Phase to Split-Phase Inverters with Advanced Grid Support Functions for Grid-Interactive Applications

This work presents a cost-effective single-phase to split-phase inverter with a reduced switch count, achieving grid interactive performance while maintaining operational efficiency. The proposed system integrates an Andronov-Hopf oscillator based secondary controller, which inherently embeds a nonlinear resistive droop architecture, ensuring rapid dynamic response. A Lyapunov energy function-based primary control enhances transient stability and regulation, while an internal model-based point of common coupling voltage estimation enables cost optimization without additional sensors. Equipped with advanced grid support functionalities, the inverter facilitates seamless distribution system operation with enhanced robustness. The effectiveness of the proposed architecture and control strategy is validated through MATLAB/Simulink and PLECS simulations, demonstrating its feasibility for high-performance grid-supportive applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Evaluation of a Single-Phase Grid-Forming Inverter Through Hardware Experiments

This study conducts hardware experiments to assess the performance of a commercial single-phase grid-forming (GFM) inverter using a purely hardware-based approach. We adhere to a testing protocol for the GFM inverter and enhance it by exploring the transient performance of GFM inverters across various grid dynamic events. Quantifiable performance metrics are established for each testing scenario to gain insights into the performance of the single-phase GFM inverters. Based on the comprehensive tests, the following observations are summarized: 1) The performance of the single-phase GFM inverter is satisfactory, and it is capable of being the islanding master for residence homes when the main grid is gone. 2) For frequency response, the inverter is able to stay connected but cannot inject the needed active power to support the grid. This may be improved by the manufacturer by using droop control. 3) The GFM inverter exhibits harmful transients in voltage and frequency during islanding operation, which can be enhanced by maintaining the same operating points before and after the breaker is open.

dynamic performance↗

Testing and Analysis of Grid Forming Inverter Control for Achieving Resilient and Economic Operation of an Islanded Microgrid

This investigation examines the feasibility of operating a battery energy storage system (BESS) in parallel with synchronous generation by using grid forming (GFM) control in order to achieve frequency control objectives while mitigating increases to operating costs in the context of an islanded microgrid. The BESS GFM control system, which is based on conventional droop techniques, is modeled along with the overall microgrid using the Real Time Digital Simulator (RTDS) to allow for integration of genset controller hardware. A series of simulations are performed to test the voltage and frequency regulation capability of the BESS control system when the primary frequency regulating genset is tripped offline. The results of the simulations suggest that the GFM control scheme will successfully maintain frequency and voltage stability, which will enable operation without a back-up genset while not compromising the microgrid resiliency to contingencies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lyapunov stability of smart inverters using linearized distflow approximation

Fast-acting smart inverters that utilize preset operating conditions to determine real and reactive power injection/consumption can create voltage instabilities (over-voltage, voltage oscillations and more) in an electrical distribution network if set-points are not properly configured. In this work, linear distribution power flow equations and droop-based Volt–Var and Volt–Watt control curves are used to analytically derive a stability criterion using Lyapunov analysis that includes the network operating condition. The methodology is generally applicable for control curves that can be represented as Lipschitz functions. The derived Lipschitz constants account for smart inverter hardware limitations for reactive power generation. A local policy is derived from the stability criterion that allows inverters to adapt their control curves by monitoring only local voltage, thus avoiding centralized control or information sharing with other inverters. The criterion is independent of the internal time-delays of smart inverters. Simulation results for inverters with and without the proposed stabilization technique demonstrate how smart inverters can mitigate voltage oscillations locally and mitigate real and reactive power flow disturbances at the substation under multiple scenarios. The study concludes with illustrations of how the control policy can dampen oscillations caused by solar intermittency and cyberattacks.

42 ENGINEERING↗

UNIFI 1-MW Multi-Vendor Grid-Forming Inverter Test Updates

This presentation gives an update on UNIFI 1MW multi-vendor GFM inverter testing. The 1MW demo enters the last stage of the test, which is the integration test. And the main objectives of the integration tests include: 1) explore the interoperability of dispatching a future grid with energy mix (GFM inverters, GFL inverters and synchronous machine). The presentation highlights one example test, ROCOF, and summarizes all the key learning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a Marx Modulator for FNAL Linac

A Marx-topology modulator has been designed and developed at the Fermi National Accelerator Laboratory under the Proton Improvement Plan (PIP). This modulator replaces the previous triode hard-tube design, increasing reliability, lowering operational costs, and maintaining waveform accuracy. The Marx modulator supplies the anode of the 7835 VHF power triode tube with a 35 kV, 375 Amp, 460 μs pulse at 15 Hz. It consists of 54 individual Marx cells, each containing a 639 μF capacitor charged to 900 Volts, combined in series with IGBT switches to create the desired output waveform. This requires variable rise and fall times, flattening of capacitive droop, and feedforward beam loading compensation. All five 201.25 MHz RF systems have been upgraded to Marx modulators to ensure continued operation of the linear accelerator.

43 PARTICLE ACCELERATORS↗