Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “double pulse test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Magnetically Suspended Linear Pulse Motor for Semiconductor Wafer Transfer in Vacuum Chamber

This paper describes a magnetically suspended linear pulse motor for a semiconductor wafer transfer robot in a vacuum chamber. The motor can drive a wafer transfer arm horizontally without mechanical contact. In the construction of the magnetic suspension system, four pairs of linear magnetic bearings for the lift control are used for the guidance control as well. This approach allows us to make the whole motor compact in size and light in weight. The tested motor consists of a double-sided stator and a transfer arm with a width of 50 mm and a total length of 700 mm. The arm, like a ladder in shape, is designed as the floating element with a tooth width of 4 mm (a tooth pitch of 8 mm). The mover mass is limited to about 1.6 kg by adopting such an arm structure, and the ratio of thrust to mover mass reaches to 3.2 N/kg under a broad air gap (1 mm) between the stator teeth and the mover teeth. The performance testing was carried out with a transfer distance less than 450 mm and a transfer speed less than 560 mm/s. The attitude of the arm was well controlled by the linear magnetic bearings with a combined use, and consequently the repeatability on the positioning of the arm reached to about 2 micron. In addition, the positioning accuracy was improved up to about 30 micron through a compensation of the 128-step wave current which was used for the micro-step drive with a step increment of 62.5 micron.

Moriyama, Shin-Ichi↗

A versatile burst generator for LDV

A laser-Doppler velocimeter (LDV) burst generator developed for calibration of an LDV before an actual test is described. This generator uses voltage-controlled oscillators to produce the information frequency up to 1 MHz and the pedestal frequency up to 10 MHz. The amplitude and the frequency of each signal can be adjusted independently, and the generator is capable of producing a single burst or a variety of periodic and aperiodic bursts. Variable symmetry in the burst signal can be introduced to the point of producing the 'double-pulse' burst. An LED display is used for the readout of the information and the pedestal frequencies.

Youngbluth, O., Jr.↗

Copper atom based measurements of velocity and turbulence in arc jet flows

Laboratory and field measurements were combined with a modeling effort to explore the feasibility of using atomic copper laser-induced fluorescence to measure velocity, turbulence, and temperature in arcjet flows. Both CW and pulsed frequency-doubled dye lasers were used to demonstrate the ability to measure velocity with 10 percent accuracy at rates of 200,000 cm/s in a rarefied flow of Cu atoms seeded in He. The pulsed laser established a threshold energy for power-broadening of the absorption line at 3.5 x 10 to the -8th J/sq cm. Field measurements at the NASA/JSC 10-MW arcjet facility demonstrated the ability to perform these measurements under actual test conditions. The use of this technique to measure freestream temperatures in the flow was examined for the 0.08/cm linewidth laser used in the NASA/JSC effort. Finally, single-shot turbulence measurements at the USAF/AEDC 35-MW H2 arcjet facility were measured with 4 percent accuracy using the laser/absorption line-overlap technique.

Marinelli, William J.↗

Terrestrial whisker growth experiments which anticipate some special effects of a space station environment

The effects of the absence of gravitationally driven thermal convection on the growth of whiskers by chemical reduction of metal salts was studied. It was possible to accomplish nearly complete suppression of such convection. Suppression of the convection does indeed effect the growth but in subtle, not necessarily detrimental ways: none of the changes observed were such as to hamper efforts to produce whiskers in space. Copper whiskers grown from cuprous iodide respond most positively to the suppression of convection; therefore, they are strongly recommended for tests in the space environment. Cobalt whiskers grown from cobaltous bromide show the greatest independence from conditions of convection and applied electric fields of any material studied; therefore, this medium is highly recommended. A strong pulse of electric field forces the whiskers to stick to the growth vessel top plate, this facilitates study or "harvesting'. On the space station it is recommended that the growth vessels be mounted outside the laboratory and joined with the station by means of double vacuum valves and gas service lines.

Hobbs, H. H.↗

Mode-locked frequency doubled Nd:YAG laser

The design, fabrication, test, and delivery of two mode-locked, frequency doubled Nd:YAG laser systems are described. Each system was comprised of two units, the laser head and optics on an Invar plate and the electronics control unit in a relay rack chassis panel. Laser number one operated at a repetition rate of 400 MHz and was designed for use in an optical communication system. Laser number two operated at 200 MHz repetition rate and was designed for optical ranging and target signature experiments. Both lasers had a pulse width of 200 ps at the 10% amplitude points at 1.064 micrometer wavelength (150 ps at 0.532 micrometers) with an amplitude stability of + or - 4%. Output power exceeded the design goals.

Brookman, J. S.↗

A xenon ion propulsion module for enhanced spacecraft capability

Design, development and preliminary testing of a two-engine xenon ion propulsion module for early flight evaluation is described. Extensive use is made of flight spare propellant system components and also engineering model 30-cm ion engines and assemblies originally developed for the Solar Electric Propulsion System program. Significant design features include a redundant propellant feed system that incorporates a novel gas pulse assembly for rapid and completely reliable engine startup, a central neutralizer subsystem with dual neutralizers for redundancy, and major ion engine performance improvements resulting in a nearly doubling of the 30-cm engine thrust in addition to operating on xenon rather than mercury propellant. At a module input power of 10.0 kw, maximum thrust and specific impulse are projected to be 0.4 N and 3,500 sec. respectively, for a total module efficiency of 67 percent. Total mass of the xenon ion module, including the propellant tank, is only 70.2 kg. The technical approaches taken towards developing and integrating the subsystems comprising this ion propulsion module are presented and discussed in detail.

Aston, G.↗

The 30 GHz solid state amplifier for low cost low data rate ground terminals

This report details the development of a 20-W solid state amplifier operating near 30 GHz. The IMPATT amplifier not only met or exceeded all the program objectives, but also possesses the ability to operate in the pulse mode, which was not called for in the original contract requirements. The ability to operate in the pulse mode is essential for TDMA (Time Domain Multiple Access) operation. An output power of 20 W was achieved with a 1-dB instantaneous bandwidth of 260 MHz. The amplifier has also been tested in pulse mode with 50% duty for pulse lengths ranging from 200 ns to 2 micro s with 10 ns rise and fall times and no degradation in output power. This pulse mode operation was made possible by the development of a stable 12-diode power combiner/amplifier and a single-diode pulsed driver whose RF output power was switched on and off by having its bias current modulated via a fast-switching current pulse modulator. Essential to the overall amplifier development was the successful development of state-of-the-art silicon double-drift IMPATT diodes capable of reproducible 2.5 W CW output power with 12% dc-to-RF conversion efficiency. Output powers of as high as 2.75 W has been observed. Both the device and circuit design are amenable to low cost production.

Ngan, Y. C.↗

Chromosome Model reveals Dynamic Redistribution of DNA Damage into Nuclear Sub-domains

Several proteins involved in the response to DNA double strand breaks (DSB) form microscopically visible nuclear domains, or foci, after exposure to ionizing radiation. Radiation-induced foci (RIF) are believed to be located where DNA damage is induced. To test this assumption, we analyzed the spatial distribution of 53BP1, phosphorylated ATM and gammaH2AX RIF in cells irradiated with high linear energy transfer (LET) radiation. Since energy is randomly deposited along high-LET particle paths, RIF along these paths should also be randomly distributed. The probability to induce DSB can be derived from DNA fragment data measured experimentally by pulsed-field gel electrophoresis. We used this probability in Monte Carlo simulations to predict DSB locations in synthetic nuclei geometrically described by a complete set of human chromosomes, taking into account microscope optics from real experiments. As expected, simulations produced DNA-weighted random (Poisson) distributions. In contrast, the distributions of RIF obtained as early as 5 min after exposure to high LET (1 GeV/amu Fe) were non-random. This deviation from the expected DNA-weighted random pattern can be further characterized by relative DNA image measurements. This novel imaging approach shows that RIF were located preferentially at the interface between high and low DNA density regions, and were more frequent in regions with lower density DNA than predicted. This deviation from random behavior was more pronounced within the first 5 min following irradiation for phosphorylated ATM RIF, while gammaH2AX and 53BP1 RIF showed very pronounced deviation up to 30 min after exposure. These data suggest the existence of repair centers in mammalian epithelial cells. These centers would be nuclear sub-domains where DNA lesions would be collected for more efficient repair.

Costes, Sylvain V.↗

Wind Tunnel Testing of Active Flow Control on High-Lift Common Research Model

A 10%-scale high-lift version of the Common Research Model (CRM-HL) and an Active Flow Control (AFC) version of the model equipped with a simple-hinged flap (CRM-SHLAFC) were successfully tested. The tests were performed in the 14- by 22-Foot Subsonic Tunnel (14x22) at the NASA Langley Research Center (LaRC). The CRM-HL has a set of 37° inboard and outboard single-element Fowler flaps. The CRM-SHL-AFC has a set of 50° inboard and 55° outboard simple-hinged flaps equipped with integrated modular AFC cartridges on the flap shoulder. Both high-lift configurations share the same 30° slats and engine nacelle. Three new types of AFC devices were examined: the Double-Row Sweeping Jets (DRSWJ), the Alternating Pulsed Jets (APJ), and the High Efficiency Low Power (HELP) actuators. The DRSWJ and the APJ actuators used two rows of unsteady jets, whereas the HELP actuators used a combination of unsteady and steady jets, to overcome strong adverse pressure gradients while minimizing the mass flow usage. Nozzle pressure ratio, mass flow consumption and the power coefficient, which takes account of both supply air pressure and mass flow usage for the actuators, were used for judging the performance efficiency of the AFC devices. A prestall lift performance degradation for the CRM-HL configuration was resolved with a properly placed nacelle chine. The configuration with nacelle chine was chosen as the representative reference conventional high-lift case for comparison with the CRMSHL- AFC. The AFC-induced lift coefficient increment (DCL) was maintained for the entire lift curve over the CRM-SHL-AFC case with no AFC for almost all flow-control cases examined. The lift curve of the reference CRM-HL have a slightly steeper slope compared to those of the CRM-SHL-AFC configurations. The HELP actuation concept was extremely effective in controlling flow separation in the “linear region” of the curves comparing lift coefficient to mass flow rate. The HELP actuation achieved a targeted DCL of 0.50 using a moderate amount of mass flow and supply air pressure. The CRM-SHL-AFC configuration equipped with HELP actuation was able to match or exceed the lift performance of the reference conventional high-lift configuration (i.e., CRM-HL equipped with a nacelle chine), thus meeting the NASA Advanced Air Transport Technology (AATT) project goal.

Lin, John C.↗

Optimization of Picosecond Laser Parameters for Surface Treatment of Composites Using a Design of Experiments (DOE) Approach

Based on guidelines from the Federal Aviation Administration, research supported by the NASA Advanced Composites Project is investigating methods to improve process control for surface preparation and pre-bond surface characterization on aerospace composite structures. The overall goal is to identify high fidelity, rapid, and reproducible surface treatments and surface characterization methods to reduce the uncertainty associated with the bonding process. The desired outcome is a more reliable bonded airframe structure, and to reduce time to achieve certification. In this work, a design of experiments (DoE) approach was conducted to determine optimum laser ablation conditions using a pulsed laser source with a nominal pulse width of 10 picoseconds. The laser power, frequency, scan speed, and number of passes (1 or 2) were varied within the laser system operating boundaries. Aerospace structural carbon fiber reinforced composites (Torayca® 3900-2/T800H) were laser treated, then characterized for contamination, and finally bonded for mechanical testing. Pre-bond characterization included water contact angle (WCA) using a handheld device, ablation depth measurement using scanning electron microscopy (SEM), and silicone contamination measurement using laser induced breakdown spectroscopy (LIBS). In order to accommodate the large number of specimens in the DoE, a rapid-screening, double cantilever beam (DCB) test specimen configuration was devised based on modifications to ASTM D5528. Specimens were tested to assess the failure modes observed under the various laser surface treatment parameters. The models obtained from this DoE indicated that results were most sensitive to variation in the average laser power. Excellent bond performance was observed with nearly 100% cohesive failure for a wide range of laser parameters. Below about 200 mW, adhesive failure was observed because contamination was left on the surface. For laser powers greater than about 600 mW, large amounts of fiber were exposed, and the failure mode was predominately fiber tear.

Palmieri, Frank L.↗

Pulsed electromagnetic gas acceleration

Terminal voltage measurements with various cathodes and anodes in a high power, quasi-steady magnetoplasmadynamic (MPD) are discussed. The magnitude of the current at the onset of voltage fluctuations is shown to be an increasing function of cathode area and a weaker decreasing function of anode area. Tests with a fluted cathode indicated that the fluctuations originate in the plasma adjacent to the cathode rather than at the cathode surface. Measurements of radiative output from an optical cavity aligned to examine the current-carrying portion of a two-dimensional, 56 kA magnetoplasmadynamic discharge reveal no lasing in that region, consistent with calculations of electron excitation and resonance radiation trapping. A voltage-swept double probe technique allows single-shot determination of electron temperature and electron number density in the recombining MPD exhaust flow. Current distributions within the cavity of MPD hollow cathodes for various static prefills with no injected mass flow are examined.

Jahn, R. G.↗

Oxygen Spectroscopy Laser Sounding Instrument for Remote Sensing of Atmospheric Pressure

We report on the progress of an Oxygen spectroscopy laser sounding instrument designed as a calibration channel for a carbon dioxide (CO2) laser sounding instrument. We have developed a pulsed, frequency-doubled, fiber laser transmitter for use in an oxygen instrument. The instrument concept uses the pressure broadening of spectroscopic lines of the diatomic oxygen A-band to deduce atmospheric pressure. There are many uses for this measurement but we are developing it primarily to make a measurement of the dry mixing ratio of CO2. The CO2 measurement can be affected by changes in atmospheric properties such as humidity, temperature and pressure. To remove these variances requires measuring a stable, well-mixed gas like Oxygen. We will report on the basic theory behind the instrument, measurements made at a test site at Goddard, review the current state of the instrument technologies and the necessary steps to bring them to space readiness, and review the current state of the instrument development.

Stephen Mark A.↗

NIAC Phase-2 Final Report for Astrophysics and Technical Lab Studies of a Solar Neutrino Spacecraft Detector

The Sun provides all the energy that our planet needs for life and has been doing so for five billion years. Understanding our Sun and its interior is one of the major goals of the NASA Science program. Still this is a very difficult task because very little makes it directly out of the Sun’s interior. The energy we see today, that warms the Earth, was made 50,000 to 80,000 years ago and is only now coming to the surface to make light. However, neutrinos penetrate matter almost without interaction and make it to Earth in only eight minutes from creation. Since neutrinos interact only weakly they are hard to detect; never-the-less within the last ten years neutrino detectors on Earth have started to reliably detect neutrinos from the fusion reactions in the interior of the Sun and scientists have started to use this information to investigate the Sun’s nuclear furnace. Changes in solar neutrino flux make it advantageous to take a neutrino detector into space since the solar neutrino intensity changes dramatically as the inverse square of the distance from the Sun, by five orders of magnitude when going from the Earth to the Sun. Launch of a neutrino detector into space toward the Sun will: a) aim to significantly increase the neutrino flux 10,000x allowing for a smaller detector which improves detector energy resolution and performance, b) attempt to completely eliminate background terrestrial neutrino sources for improved measurement accuracy, and c) conduct unique science experiments near the Sun not achievable with much larger detectors on the Earth. NASA's interest in deep space exploration has been a key factor in its unmanned spacecraft development and launch of exploration science satellites and spacecraft. NASA has done exceptional experiments in space where science benefits from the unique platform of spacecraft that provides unprecedented views. For example, the Hubble Space Telescope is really a small and very common instrument, but when it is put into an orbit high above the Earth, it becomes one of the most powerful optical observatories man has ever made. Moving neutrino observations to space is the next obvious step. The concept of putting a neutrino detector in close orbit of the sun is completely unexplored and innovative. Its scientific return is to vastly enhance the understanding of the solar interior which is a NASA major goal as stated in the decadal survey. Preliminary calculations show that such a spacecraft if properly shielded, can operate in this environment both taking data of neutrino interactions which can be distinguished from random background rates of solar Electromagnetic emissions, Galactic charged cosmic-ray, and gamma-rays by using a double pulsed signature. The NIAC Phase-1 simulations have shown this idea to be very successful in eliminating background and identifying the neutrino interaction signal, hence this spacecraft detector concept once demonstrated to be Technical Readiness Level 7 and flight mission-ready would enable a whole new type of mission to explore and study our Sun, in details that could neither be done with the largest neutrino detectors on Earth nor other types of space-craft measurements that are not using neutrino detection. Our goal in this NIAC Phase-2 was to take the detector simulation ideas and construct a prototype for testing in the lab with tagged sources to evaluate and demonstrate that the performance in the simulations are borne out by a prototype.

Neutrino↗

Multiphoton ionization of N2 by the third harmonic of a Nd:YAG laser - A new avenue for air diagnostics

Laser-induced N2 ionization is accomplished using a commercially available Nd:YAG laser, and confirmed by means of ion-collection and spectral measurements. Neutral N2 is excited by six photons of the third harmonic frequency, or 355 nm, and is transformed to an ionized state. The radiation at 355 nm is separated from the fundamental and frequency-doubled Nd:YAG radiation to guarantee monochromatic incident radiation. Intense lines near 391.4 nm are found in the initial laser polarization and for a 90-degree rotation of polarization. The radiation at 391.4 nm is associated with an incoherent laser-induced flourescence process related to an ionized-state transition, and increases quadratically with laser power. A 45-mJ laser pulse focused to a diameter of 17 microns can produce an ion concentration of 3.25 x 10 to the 13th ions/cu cm. The large ion concentration and robust fluorescence signal make this technique an efficient method for time-of-flight velocimetry and in-flight testing.

Laufer, Gabriel↗

The 15 cm diameter ion thruster research

The startup reliability of a 15 cm diameter mercury bombardment ion thruster which employs a pulsed high voltage tickler electrode on the main and neutralizer cathodes is examined. Startup of the thruster is achieved 100% of the time on the main cathode and 98.7% of the time on the neutralizer cathode over a 3640 cycle test. The thruster was started from a 20 C initial condition and operated for an hour at a 600 mA beam current. An energy efficiency of 75% and a propellant utilization efficiency of 77% was achieved over the complete cycle. The effect of a single cusp magnetic field thruster length on its performance is discussed. Guidelines are formulated for the shaping of magnetic field lines in thrusters. A model describing double ion production in mercury discharges is presented. The production route is shown to occur through the single ionic ground state. Photographs of the interior of an operating-hollow cathode are presented. A cathode spot is shown to be present if the cathode is free of low work-function surfaces. The spot is observed if a low work-function oxide coating is applied to the cathode insert. Results show that low work-function oxide coatings tend to migrate during thruster operation.

Wilbur, P. J.↗

Performance Improvements to the Lidar Atmospheric Sensing Experiment (LASE)

Lidar Atmospheric Sensing Experiment (LASE) is the first fully-engineered, modular, tunable, autonomous Differential Absorption Lidar (DIAL) system for the remote measurement of water vapor, aerosols and clouds across the troposphere. It was designed, built and environmentally tested at LARC. LASE was designed to fly aboard a NASA/Ames ER-2 aircraft (NASA's high altitude aircraft) and operate at altitudes from 58,000 to 70,000 feet. Since its first flight on May 11, 1994, it has flown 28 total missions on board the ER-2. LASE has been validated with results showing an accuracy better than the initial requirement for vertical profiles of water vapor in the troposphere. LASE can also deploy on several other aircraft including the NASA P-3 and will fly aboard the NASA DC-8 during the Convection And Moisture EXperiment (CAMEX) in July-September 1998. The tunable laser system of LASE was designed to operate in a double-pulse mode at 5Hz, with energy outputs of up to 15OmJ per pulse in the 813 to 819nm wavelength region and with 99% of the output energy within a spectral interval of 1.06 pm. Sixteen wavelengths were selected to cover the various water vapor absorption cross sections needed for the DIAL measurement. The Ti:Sapphire laser was constructed using a frequency-doubled Nd:YAG laser as the pump source and a single mode diode laser as a injection seeder for the Ti:Al2O3 laser. We have improved the LASE instrument in several important ways. Improvements to the seed source have demonstrated that DFB laser diodes can be used as reliable seed sources on airborne DIAL instruments. The DFB diode has enabled LASE to gather more data and significantly reduced the maintenance required to insure that the system performance requirements are met. The multiwavelength sequential seeding technique is the current method of data collection for LASE. It has the advantages of providing an entire atmospheric coverage of H2O(v) from the ground to the aircraft altitude along a single ground track. The development of a flight deployable system to measure spectral purity will insure that the LASE instrument or any future flight based DIAL system can meet the performance specifications to insure data accuracy.

Edwards, W. C.↗

Development and Evaluation of a High Sensitivity DIAL System for Profiling Atmospheric CO2

A ground-based 2-micron Differential Absorption Lidar (DIAL) CO2 profiling system for atmospheric boundary layer studies and validation of space-based CO2 sensors is being developed and tested at NASA Langley Research Center as part of the NASA Instrument Incubator Program. To capture the variability of CO2 in the lower troposphere a precision of 1-2 ppm of CO2 (less than 0.5%) with 0.5 to 1 km vertical resolution from near surface to free troposphere (4-5 km) is one of the goals of this program. In addition, a 1% (3 ppm) absolute accuracy with a 1 km resolution over 0.5 km to free troposphere (4-5 km) is also a goal of the program. This DIAL system leverages 2-micron laser technology developed under NASA's Laser Risk Reduction Program (LRRP) and other NASA programs to develop new solid-state laser technology that provides high pulse energy, tunable, wavelength-stabilized, and double-pulsed lasers that are operable over pre-selected temperature insensitive strong CO2 absorption lines suitable for profiling of lower tropospheric CO2. It also incorporates new high quantum efficiency, high gain, and relatively low noise phototransistors, and a new receiver/signal processor system to achieve high precision DIAL measurements. This presentation describes the capabilities of this system for atmospheric CO2 and aerosol profiling. Examples of atmospheric measurements in the lidar and DIAL mode will be presented.

Ismail, Syed↗

A Joint NICER and XMM-Newton View of the "Magnificent" Thermally Emitting X-ray Isolated Neutron Star RX J1605.3+3249

Thermally emitting X-ray isolated neutron stars (NSs) represent excellent targets for testing cooling surface emission and atmosphere models, which are used to infer the physical parameters of the NS. Among the seven known members of this class, RXJ1605.3+3249 is the only one that still lacks confirmation of its spin period. Here we analyze NICER and XMM-Newton observations of RXJ1605.3+3249, in order to address its timing and spectral behavior. Contrary to a previous tentative detection, but in agreement with the recent work by Pires et al., we find no significant pulsation with a pulsed fraction higher than 1.3% (3σ) for periods above 150 ms. We also find a limit of 2.6% for periods above 2 ms, despite searches in different energy bands. The X-ray spectrum can be fit by either a double-blackbody model or by a single-temperature magnetized atmosphere model, both modified by a Gaussian absorption line at ∼0.44 keV. The origin of the absorption feature as a proton cyclotron line or as an atomic transition in the NS atmosphere is discussed. The predictions of the best-fit X-ray models extended to IR, optical, and UV bands, are compared with archival data. Our results are interpreted in the framework of a fallback disk scenario.

Christian Malacaria↗