Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dose consequence analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Quantitative Assessment for Advanced Reactor Radioisotope Screening Utilizing a Heat Pipe Reactor Inventory

This report documents a method for the quantitative identification of radionuclides of potential interest for accident consequence analysis involving advanced nuclear reactors. Based on previous qualitative assessments of radionuclide inventories for advanced reactors coupled with the review of a radiological inventory developed for a heat pipe reactor, a 1 Ci activity airborne release was calculated for 137 radionuclides using the MACCS 4.1 code suite. Several assumptions regarding release conditions were made and discussed herein. The potential release of a heat pipe reactor inventory was also modeled following the same assumptions. Results provide an estimation of the relative EARLY and CHRONC phase dose contribution from advanced reactor radionuclides and are normalized to doses from equivalent releases of I-131 and Cs-137, respectively. Ultimately, a list of 69 radionuclides with EARLY or CHRONC dose contributions at least 1/100th that of I-131 or Cs-137, respectively – 48 of which are currently considered for LWR consequence analyses – was identified of being of potential importance for analyses involving a heat pipe reactor.

07 ISOTOPE AND RADIATION SOURCES↗

Mutations induced in Tradescantia by small doses of X-rays and neutrons - Analysis of dose-response curves.

Dose-response curves for pink somatic mutations in Tradescantia stamen hairs were analyzed after neutron and X-ray irradiation with doses ranging from a fraction of a rad to the region of saturation. The dose-effect relation for neutrons indicates a linear dependence from 0.01 to 8 rads; between 0.25 and 5 rads, a linear dependence is indicated for X-rays also. As a consequence the relative biological effectiveness reaches a constant value (about 50) at low doses. The observations are in good agreement with the predictions of the theory of dual radiation action and support its interpretation of the effects of radiation on higher organisms. The doubling dose of X-rays was found to be nearly 1 rad.

Sparrow, A. H.↗

Behavioral consequences of low dose radiation and sex differences in MCAT mouse model

Our study used 1-year old C57BL/6NJ male and female mice (astronaut-relevant age) that underwent exposure to 0.5 gray of gamma radiation and were euthanized 12 weeks after. In this study, we used an MCAT mouse model for mitochondrial ROS quenching, which overexpress human catalase. MCAT mice were shown to live longer and age better. Hence, in this study we determined whether quenching ROS in the mitochondria will mitigate the adverse effects of ionizing radiation exposure on spaceflight-relevant tissues. As part of the analysis, we have completed 5 different behavioral tests which focus on memory, physical stance, stress, anxiety, and other mission relevant behaviors. In the Neuro-score battery, performed after both 1and 8 weeks post IR we saw that all female groups had significantly higher scores compared to males. When comparing the baseline vs 8 weeks of radiation, we saw that all the male groups (including the sham) had lower neuro-score, pointing out to aging effect in addition to IR. In the female groups only the female IR group had lower neuro-score and the MCAT group was protected from this effect. In the Nestlet building test we saw similarly that only females were affected by radiation, having lower scores and this effect was mitigated in the MCAT animals as well. In the Catwalk test we saw that females were faster, had higher swing speed and stride length in all four paws. Males had higher stand, step cycle and max contact area. Aging is associated with slowing of gait speed, swing speed and shortening of stride length which we see in males, this is consistent with physical appearance where males look markedly older. In the Light-Dark Box test we saw that females were more frequently present in the light side and altered zones more frequently, pointing out to a more exploratory and less anxious pattern of behavior. Similarly, to what was detected in the Nest building and Neuro-score test, in the Barnes maze test, during the acquisition phase (learning) we saw that IR affected more the females who did not do better in the maze after 4 days. On the other hand, during the probe phase of the test (spatial memory) the females visited the target hole and the box quadrant more often, but also had more errors vs males, which points out to possible serial escape vs spatial escape strategy. Overall, we see that older females look physically better are faster and perform better almost in all behavioral tests compared to their male counterparts. On the other hand, they are more sensitive to low dose radiation in many cases, in some cases this effect was mitigated in the MCAT model pointing out to the importance of ROS in these stressors. In the near future we will focus on corelating these behavioral tests with molecular findings such as for example brain IHC, plasma and hippocampal cytokines in order to find specific biomarkers for behavioral deficits.

radiation↗

Actively Controlled Louver for Human Spacecraft Radiator Ultraviolet (UV), Dust, and Freeze Protection

The paper examines the use of actively controlled louvers for human spacecraft radiators. State of the Art (SOA) radiators were design for Low Earth Orbit (LEO) operations where Ultraviolet (UV) radiation and dust have miniscule performance impacts. However, Artemis missions to the lunar orbit or surface will expose the radiators to high dose UV radiation and dust, which can degrade the radiator coating emissivity by up to 50% and consequently reduce performance early in missions. In addition, environmental nighttime temperatures at the lunar south pole are significantly colder and linger longer than LEO, and may require up to 4 kW of heater power to prevent coolant tubes from freezing, thawing, and rupturing. Analysis showed equipping the radiators with actively controlled louvers attenuated the UV radiation and dust effects, and limited degradation to less than 10% through End of Life (EOL) of missions. Furthermore, analysis demonstrated the ability to eliminate the heater power needed for freeze protection. Louver technology is a promising solution to maintain radiator performance and integrity for Artemis missions, but heritage louvers are passively controlled and only been used on small satellites. The technology requires maturing to active control, or motor actuated, to achieve faster thermal response times. Design considerations are discussed in this paper.

Louver↗

Statistical Uncertainty of Inhalation Dose Coefficients in Consequence Management: Propagated Dose Uncertainty in ICRP 66 Human Respiratory Tract Model

Reference inhalation dose models rely on deterministic biokinetics and reference computational phantoms, limiting their applicability to the variability present in population-specific exposures encountered in emergency response scenarios. Here, this study introduces REDCAL, a Python-based computational framework developed to propagate uncertainty in inhalation dose coefficients using the International Commission on Radiological Protection (ICRP) Publication 66 Human Respiratory Tract Model. REDCAL integrates ICRP deposition and clearance models, systemic biokinetics, and governing physics principles, and leverages Sandia National Laboratories’ Dakota toolkit for uncertainty quantification via Latin Hypercube Sampling. REDCAL was validated against DCAL, with biokinetic retention results differing by less than 1% and effective dose coefficients by less than 2% across all tested radionuclides. Stochastic sampling introduced variability in dose coefficients, with geometric standard deviations (GSD) in committed effective dose coefficients (CEDC) ranging from 1.0 to 1.5, based on lognormal distribution fits. Analysis demonstrated that variations in the activity median aerodynamic diameter (AMAD) notably influenced the computed CEDC values. Smaller particles (<1 µm) increased doses by 20–30% due to deeper lung deposition and prolonged retention for alpha emitting radionuclides, such as 241 Am and 239 Pu. Radionuclides with fast clearance, such as 133 I, demonstrated a dose reduction exceeding 50%, as AMAD increased beyond 5 µm due to upper airway deposition and rapid mucociliary clearance. The greatest GSD among the radionuclides reported in this study was for 241 Am. In most cases, the largest GSDs in the CEDC were associated with larger particle sizes, an expected outcome, as ICRP Publication 66 defines GSD in particle size as a function of AMAD, resulting in an extended tail of the lognormal distribution. The findings support improved inhalation dose assessments and enhance consequence management strategies for the U.S. Federal Radiological Monitoring and Assessment Center by quantifying uncertainty in dose coefficients and strengthening decision-making for emergency response scenarios.

Biokinetic Modeling↗

Modeling beta-adrenergic control of cardiac myocyte contractility in silico

The beta-adrenergic signaling pathway regulates cardiac myocyte contractility through a combination of feedforward and feedback mechanisms. We used systems analysis to investigate how the components and topology of this signaling network permit neurohormonal control of excitation-contraction coupling in the rat ventricular myocyte. A kinetic model integrating beta-adrenergic signaling with excitation-contraction coupling was formulated, and each subsystem was validated with independent biochemical and physiological measurements. Model analysis was used to investigate quantitatively the effects of specific molecular perturbations. 3-Fold overexpression of adenylyl cyclase in the model allowed an 85% higher rate of cyclic AMP synthesis than an equivalent overexpression of beta 1-adrenergic receptor, and manipulating the affinity of Gs alpha for adenylyl cyclase was a more potent regulator of cyclic AMP production. The model predicted that less than 40% of adenylyl cyclase molecules may be stimulated under maximal receptor activation, and an experimental protocol is suggested for validating this prediction. The model also predicted that the endogenous heat-stable protein kinase inhibitor may enhance basal cyclic AMP buffering by 68% and increasing the apparent Hill coefficient of protein kinase A activation from 1.0 to 2.0. Finally, phosphorylation of the L-type calcium channel and phospholamban were found sufficient to predict the dominant changes in myocyte contractility, including a 2.6x increase in systolic calcium (inotropy) and a 28% decrease in calcium half-relaxation time (lusitropy). By performing systems analysis, the consequences of molecular perturbations in the beta-adrenergic signaling network may be understood within the context of integrative cellular physiology.

Non-NASA Center↗

Radiological Safety Analysis Computer Program V 7.2

Users generates a fission product inventory from either reactor operating history or a nuclear criticality event. RSAC-7 models the effects of high-efficiency particulate air filters or other cleanup systems and calculates the decay and ingrowth during transport through processes, facilities, and the environment. Doses are calculated for inhalation, air immersion, ground surface, ingestion, and cloud gamma pathways. RSAC-7 is used as a tool to evaluate accident conditions in emergency response scenarios, radiological sabotage events, and safety basis accident consequences.

Jordan, RobertaA. [Idaho National Laboratory (INL)↗

Application of multi-criteria decision analysis techniques and decision support framework for informing select agent designation for agricultural animal pathogens

The United States Department of Agriculture (USDA), Division of Agricultural Select Agents and Toxins (DASAT) established a list of biological agents and toxins (Select Agent List) that potentially threaten agricultural health and safety, the procedures governing the transfer of those agents, and training requirements for entities working with them. Every 2 years the USDA DASAT reviews the Select Agent List, using subject matter experts (SMEs) to perform an assessment and rank the agents. To assist the USDA DASAT biennial review process, we explored the applicability of multi-criteria decision analysis (MCDA) techniques and a Decision Support Framework (DSF) in a logic tree format to identify pathogens for consideration as select agents, applying the approach broadly to include non-select agents to evaluate its robustness and generality. We conducted a literature review of 41 pathogens against 21 criteria for assessing agricultural threat, economic impact, and bioterrorism risk and documented the findings to support this assessment. The most prominent data gaps were those for aerosol stability and animal infectious dose by inhalation and ingestion routes. Technical review of published data and associated scoring recommendations by pathogen-specific SMEs was found to be critical for accuracy, particularly for pathogens with very few known cases, or where proxy data (e.g., from animal models or similar organisms) were used to address data gaps. The MCDA analysis supported the intuitive sense that select agents should rank high on the relative risk scale when considering agricultural health consequences of a bioterrorism attack. However, comparing select agents with non-select agents indicated that there was not a clean break in scores to suggest thresholds for designating select agents, requiring subject matter expertise collectively to establish which analytical results were in good agreement to support the intended purpose in designating select agents. The DSF utilized a logic tree approach to identify pathogens that are of sufficiently low concern that they can be ruled out from consideration as a select agent. In contrast to the MCDA approach, the DSF rules out a pathogen if it fails to meet even one criteria threshold. Both the MCDA and DSF approaches arrived at similar conclusions, suggesting the value of employing the two analytical approaches to add robustness for decision making.

60 APPLIED LIFE SCIENCES↗

Application of Multi-Criteria Decision Analysis Techniques for Informing Select Agent Designation and Decision Making

The Centers for Disease Control and Prevention (CDC) Select Agent Program establishes a list of biological agents and toxins that potentially threaten public health and safety, the procedures governing the possession, utilization, and transfer of those agents, and training requirements for entities working with them. Every 2 years the Program reviews the select agent list, utilizing subject matter expert (SME) assessments to rank the agents. In this study, we explore the applicability of multi-criteria decision analysis (MCDA) techniques and logic tree analysis to support the CDC Select Agent Program biennial review process, applying the approach broadly to include non-select agents to evaluate its generality. We conducted a literature search for over 70 pathogens against 15 criteria for assessing public health and bioterrorism risk and documented the findings for archiving. The most prominent data gaps were found for aerosol stability and human infectious dose by inhalation and ingestion routes. Technical review of published data and associated scoring recommendations by pathogen-specific SMEs was found to be critical for accuracy, particularly for pathogens with very few known cases, or where proxy data (e.g., from animal models or similar organisms) were used to address data gaps. Analysis of results obtained from a two-dimensional plot of weighted scores for difficulty of attack (i.e., exposure and production criteria) vs. consequences of an attack (i.e., consequence and mitigation criteria) provided greater fidelity for understanding agent placement compared to a 1-to-n ranking and was used to define a region in the upper right-hand quadrant for identifying pathogens for consideration as select agents. A sensitivity analysis varied the numerical weights attributed to various properties of the pathogens to identify potential quantitative (x and y) thresholds for classifying select agents. The results indicate while there is some clustering of agent scores to suggest thresholds, there are still pathogens that score close to any threshold, suggesting that thresholding “by eye” may not be sufficient. The sensitivity analysis indicates quantitative thresholds are plausible, and there is good agreement of the analytical results with select agent designations. A second analytical approach that applied the data using a logic tree format to rule out pathogens for consideration as select agents arrived at similar conclusions.

60 APPLIED LIFE SCIENCES↗

Radiological Safety Analysis Computer (RSAC) Program Version 7.4 Users’ Manual

The Radiological Safety Analysis Computer (RSAC) Program Version 7.4 (RSAC-7) is the newest version of the RSAC legacy code. RSAC-7 calculates the consequences of a release of radionuclides to the atmosphere. Users generates a fission product inventory from either reactor operating history or a nuclear criticality event. RSAC-7 models the effects of high-efficiency particulate air filters or other cleanup systems and calculates the decay and ingrowth during transport through processes, facilities, and the environment. Doses are calculated for inhalation, air immersion, ground surface, ingestion, and cloud gamma pathways. RSAC-7 is used as a tool to evaluate accident conditions in emergency response scenarios, radiological sabotage events, and safety basis accident consequences. This users’ manual contains the mathematical models and operating instructions for RSAC-7. Instructions, screens, and examples are provided to guide the user through the functions provided by RSAC-7. This program is designed for users who are familiar with radiological dose assessment methods.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Proton Effects and Test Issues for Satellite Designers

Microelectronic and photonic systems in the natural space environment are bombarded by a variety of charged particles including electrons, trapped protons, cosmic rays, and solar particles (protons and other heavy ions). These incident particles cause both ionizing and non-ionizing effects when traversing a device, and the effects can be either transient or permanent. The vast majority of the kinetic energy of an incident proton is lost to ionization, creating the single event effects (SEES) and total ionizing dose (TID) effects. However, the small portion of energy lost in non-ionizing processes causes atoms to be removed from their lattice sites and form permanent electrically active defects in semiconductor materials. These defects, i.e., "displacement damage," can significantly degrade device performance. In general, most of the displacement damage effects in the natural space environment can be attributed to protons since they are plentiful and extremely energetic (and therefore not readily shielded against). For this reason, we consider only proton induced displacement damage in this course. (Nevertheless, we identify solar cells as an important example of a case where both electron and proton damage can be important since only very light shielding is feasible.) The interested reader is encouraged to explore the three previous NSREC and RADECS short courses which also treat displacement damage issues for satellite applications. Part A of this segment of the short course introduces the space environment, proton shielding issues, and requirements specifications for proton-rich environments. In order to exercise the displacement damage analysis tools for on-orbit performance predictions, the requirements document must provide the relevant proton spectra in addition to the usual total ionizing dose-depth curves. Ion-solid interactions and the nature of the displacement damage they generate have been studied extensively for over half a century, yet they still remain a subject of investigation. In this section, a description of the mechanisms by which displacement damage is produced will be followed by a summary of the major consequences for device performance in a space environment. Often the degradation of a device parameter can be characterized by a damage factor (measured in a laboratory using monoenergetic protons) that is simply the change in a particular electrical or optical parameter per unit proton fluence. In addition, we will describe the concept of a non-ionizing energy loss rate (NIEL) which quantifies that portion of the energy lost by an incident ion that goes into displacements. It has been calculated as a function of proton energy, and is analogous to (and has the same units as) the linear energy transfer (LET) for ionizing energy. We will discover that, to first order, the calculated NIEL describes the energy dependence of the measured device damage factors. This observation provides the basis for predicting proton induced device degradation in a space environment based on both the calculated NIEL and relatively few laboratory test measurements. The methodology of such on-orbit device performance predictions will be described, as well as the limitations. Several classes of devices for which displacement damage is a significant (if not the dominant) mode of radiation induced degradation will be presented.

Marshall, Cheryl J.↗

Experimental Evaluation of Deformation and Fracture Mechanisms in Highly Irradiated Austenitic Steels

The present report documents recent experimental results of analysis using scanning electron microscopy/electron backscatter diffraction (SEM-EBSD) of plastic deformation mechanisms and strain localization phenomena in austenitic steels irradiated by neutrons. Experiments were performed with specimens irradiated to 125 dpa and, additionally, with specimens that experienced radiation-induced swelling up to 3%. Section 1 briefly analyzes the deformation localization in irradiated steels and its consequences on the material performance. The section describes the advantages and importance of the SEM-EBSD approach combined with in situ mechanical testing capability. Section 2 briefly introduces the experimental tools and methods (i.e., SEM/EBSD in situ tensile frame, electric discharge machine to manufacture irradiated specimens) and describes the investigated materials (i.e., element composition, irradiation conditions, and general microstructure). Section 3 describes the key experimental results and provides a brief analysis and comparison with the datasets obtained earlier within the same task (i.e., low-dose specimens). The discussion focuses on EBSD microstructure maps with strain localization features, misorientation evolution as a function of strain, and observed deformation mechanisms. Section 4 evaluates data collected in recent years on highly irradiated steel and estimates the possible misorientation evolution under irradiation. The section introduces and discusses the concept of in-service-induced damage as an irradiation-assisted stress-corrosion cracking precursor. Section 5 summarizes the work performed. As expected, the present work results are beneficial for exploring and understanding degradation mechanisms in highly irradiated in-core materials found in light water reactors after long-term in-service life.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Improving Efficacy and Safety of Pharmacological Treatment Through Precision Health and Pharmacogenomics

INTRODUCTION: Future spaceflight will require increased crew medical autonomy as exploration class missions expand in duration and distance from Earth, especially for Mars missions. As mission duration increases, it will be essential to have appropriate amounts of effective medication to ensure the maintenance of crew health and performance. Conversely, mass and volume constraints will become more severe as future spaceflight expands beyond low Earth orbit, where resupply is difficult or becomes impossible. These constraints thus convey an urgency to tailor medications for individual crewmembers and further examine appropriate dosing regimens. BACKGROUND: Precision Health is an exciting area of medicine focused on maintaining an individual’s health and performance through in-depth understanding of an individual’s unique clinical and environmental history, genetic makeup, and molecular profiles. This approach can be adapted to better predict, monitor, and address physiological responses to the spaceflight environment. A subset of this field is pharmacogenomics (PGX), the study of how the expressed genome impacts drug responses with the goal of prescribing the right dose of the right drug at the right time. Specifically, PGX testing provides valuable information on an individual’s precise allelic variations to guide physicians in making informed decisions on drug choice and dosing to avoid adverse events and maximize efficacy. The study goal was to identify which current space pharmacy drugs could be evaluated using PGX testing and to understand the potential impact on the health and wellness of the astronaut population. Additionally, we sought to evaluate clinically available FDA-approved PGX testing solutions to better understand its applicability. METHODS: A complete list of drugs on the ISS was analyzed for risk and likelihood of drug failure and PGX actionability. This analysis encompassed both astronauts’ personal medications, including supplements and over the counter drugs (n=151) contained in the ISS medical accessory kit (IMAK), and ISS MedKit formulary medications (n=95). Duplicate medications and different formulations were removed, which resulted in a total of 157 drugs used in the subsequent analysis. A 5x5 risk assessment table was produced by examining the likelihood of drug failure compared to the consequence of drug failure (LxC). Likelihood of individual drug failure was defined by whether existing processes are sufficient to prevent ineffective treatment or impactful side effect events, as ranked from 1 (very low, can easily be prevented) to 5 (very high, cannot be prevented) during a Mars mission. In contrast, the consequence of drug failure was defined by impact to safety, schedule, cost, or technical criteria and ranked from 1 (very low) to 5 (very high). An assessment of PGX reference laboratories is currently underway to evaluate sample requirements, benefit analysis (cost vs. utility of allele variant analysis), relevance to inflight medication usage, quality of reporting in enabling clinical application, and ease of integration into electronic medical records. RESULTS: Risk assessments (LxC 5x5 table) indicated 128 medications were in the green zone where risk is acceptable, with the remaining 29 of the medications in the yellow or red zone driven predominantly due to drug failure or safety concerns. We found that current PGX testing results could impact 21% of the total medications in the ISS MedKit and IMAK; of these, 9 medications currently have direct clinically actionable guidance available. Results of the clinical PGX solution evaluations as related to these medications will be presented. CONCLUSION: PGX testing has demonstrated clear benefits in terrestrial medicine and clinical environments for the selection of proper medications, avoiding adverse drug reactions, and maximizing drug efficacy. We propose that similar benefits would be bestowed on the astronaut and commercial spaceflight passenger population by performing preemptive preflight PGX testing to reduce risk of mission failure due to ineffective or toxic medications, improve drug efficacy, and further open the door to countermeasure research. For example, PGX results could allow tailoring of specific medications at optimal doses more precisely to each individual astronaut, particularly in areas of space motion sickness, sleep aids, and analgesics. An additional benefit is that PGX results could provide information for better planning of the components of a space pharmacy for deep space missions to be more effective and efficient in the utilization of limited pharmaceutical resources. Finally, while PGX testing of the astronaut corps is not currently conducted, this approach could provide immediate impact in support of mission success by reducing risks, optimizing astronaut performance, and providing valuable insights into long-term astronaut health. Such advancements in clinical decision making are important next steps in building dynamic individual risk profiles for astronauts, increasing selection of the best treatment choice, and providing tailored countermeasures for individual crewmembers.

Pharmacogenomics↗

Improving Efficacy and Safety of Pharmacological Treatment Through Precision Medicine and Pharmacogenomics for Human Deep Space Exploration

INTRODUCTION: Future spaceflight will require increased crew medical autonomy as exploration class missions expanding duration and distance from Earth, especially for Mars missions. As mission duration increases, it will be even more essential to have appropriate amounts of effective medication to ensure the maintenance of crew health and performance. Conversely, mass and volume constraints will become more severe as future spaceflight expands beyond low Earth orbit, where resupply is difficult or becomes impossible. These constraints thus convey an urgency to further tailor medications included in the spacecraft formulary and increased examination of appropriate dosing regimens. BACKGROUND: Precision Health is an exciting area of cutting-edge research and medicine focused on maintaining an individual’s health and performance through in-depth understanding of an individual’s unique factors and molecular profiles. This approach can be adapted to better predict, monitor, and address physiological responses to the spaceflight environment. One example is the field of pharmacogenomics (PGX),the study of how the expressed genome impacts drug responses with the goal of prescribing the right dose of the right drug at the right time. Specifically, PGX testing provides valuable information on an individual’s precise allelic variations to guide physicians in making informed decisions on pharmaceutical choice and dosing to avoid adverse drug events and maximize pharmacological efficacy. The goal of this study was to evaluate which drugs in the current space pharmacy could be evaluated using PGX testing and to understand the potential impact on the health and wellness of the astronaut population. Additionally, we sought to evaluate clinically available FDA-approved PGX testing solutions to better understand its applicability. METHODS: A complete list of drugs onboard the International Space Station (ISS) was analyzed for risk and likelihood of drug failure and PGX actionability. This analysis encompassed both personal astronaut medications, including supplements and over the counter drugs (n=151) and ISS MedKit formulary medications (n=95). Duplicate medications and different formulations were removed, which resulted in 157 total drugs used in the subsequent analysis. A 5x5 risk assessment table was produced by examining the likelihood of drug failure compared to the consequence of drug failure. Likelihood of individual drug failure was defined by whether existing processes are sufficient to prevent adverse events, as ranked from 1 (very low, can easily be prevented) to 5 (very high, cannot be prevented) during a Mars mission. In contrast, the consequence of drug failure was defined by impact to safety, schedule, cost or technical and ranked from 1 (very low) to 5 (very high).A comprehensive assessment of commercially available PGX solutions is currently underway to evaluate specimen requirements, cost/benefit analysis (cost vs. number of alleles assessed), utility of variant analysis, relevance to inflight medication usage, quality of reporting in enabling clinical application, and ease of integration into electronic medical records. RESULTS: Risk assessments(LxC 5x5 table) indicated29medicationswere in the yellow or red zone driven predominantly by drug failure or safety concerns, with the remainder(n=128)of the medications in the green zone where risk is acceptable. We found that current PGX testing results could impact 21% of the total medications in the ISS MedKit and IMAK; of these, 9 medications currently have direct clinically actionable guidance available. Results of the clinical PGX solution evaluations as related to these medications will be presented. CONCLUSION: PGX testing has demonstrated clear benefits in terrestrial medicine and clinical environments for the selection of proper medications, avoiding adverse drug reactions, and maximizing drug efficacy. We propose that similar benefits would be bestowed on the astronaut and commercial spaceflight passenger population by performing preemptive pre-flight PGX testing to reduce risk of mission failure due to ineffective or toxic medications, improve targeting drug efficacy and safety, and further open the door to countermeasure research exploring PGX-related allelic variants. For example, PGX results could allow tailoring of specific medications at optimal doses more precisely to each individual astronaut, particularly in areas of space motion sickness, sleep aids, and analgesics. An additional benefit is that PGX results could provide information for better planning of the components of a space pharmacy for deep space missions to be more cost effective and more efficient in the utilization of limited pharmaceutical resources. Finally, while PGX testing of the astronaut corps is not currently conducted, this approach could provide immediate impact in support of mission success by reducing risks, optimizing astronaut performance, and providing valuable insights into long-term astronaut health. Such advancements in clinical decision making are important next steps in building dynamic individual risk profiles for astronauts, increasing crew autonomy and providing tailored countermeasures

Alice R W Tang↗

Radiological Releases from Novel Fuel Forms in Advanced Reactors During Severe Accidents for Consequence Analyses

Various advanced reactor developers are exploring the potential for reductions in the size of physical security forces and emergency planning zones. These reductions are based on robust fuel forms and inherently safe reactor designs. However, such reductions in physical protection measures could increase the risk of sabotage. To assess the possibility of reducing these measures, sabotage-induced radiological consequence analyses were carried out. These analyses considered accident scenarios that were beyond design basis accidents and overly conservative (Shah, 2025a; Shah, 2025b; Shah and Hartanto, 2026), yielding very large release fractions. These fractions, which can be used to evaluate physical protection and emergency planning requirements, have been crudely determined and applied as demonstrations for a sodium-cooled fast reactor (SFR) (Shah and Hartanto, 2025a), a high-temperature gas-cooled reactor (HTGR) (Shah and Hartanto, 2025b), a heat pipe–cooled reactor (HPR) (Shah and Hartanto, 2025c), and a molten salt–cooled reactor (MSR) (Shah et al., 2026). A Sandia National Laboratories (SNL) team used MELCOR—a fully integrated severe accident analysis code—to demonstrate the code’s capability to analyze advanced (i.e., not light water–cooled) reactors (including a fluoride salt–cooled high-temperature reactor [FHR]) and calculate radiological releases to the environment during severe accidents (Wagner et al., 2022a, 2022b, 2022c, 2023a, and 2023b). Although the analyses were carried out to demonstrate MELCOR’s growing capability, the release source terms were estimated for advanced reactors, providing valuable insights into the accident progression and radiological releases. These findings from prior SNL studies, including estimated source terms and related sensitivity studies, were leveraged to derive source terms for postulated sabotage-induced accidents. Insights from these sensitivity studies informed the scaling of SNL’s estimated source terms for the defined accident scenarios. The derived release fractions for the severe accident scenarios for the respective reactor designs can be used to perform more nuanced dose consequence analyses to evaluate the reactors’ physical protection and emergency planning zone requirements. These analyses are in accordance with the risk-informed, performance-based approach proposed under 10 CFR Part 53. This study builds on the prior source term analyses and associated sensitivity studies by SNL to derive time-dependent and design-informed release fractions. Section 2 describes the diverse advanced reactor designs analyzed by the SNL team. Section 3 discusses the severe accident analyses, the release fractions calculated, and the limitations and assumptions of the demonstration project. Section 4 presents the release percentages derived for the hypothetical sabotage-induced severe accidents at the advanced reactors. Section 5 summarizes the study’s findings and conclusions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modeling Radionuclide Inventories in MSR Off-Gas Systems with Radiochemical Transport Analysis

Molten salt reactors (MSR) contain unique characteristics that may require enhancements to modeling tools to accurately predict phenomena. One characteristic that may be advantageous to leverage during normal operation is on-line processing of the circulating fuel salt, such as an off-gas system (OGS) to remove volatile fission products. Therefore, new modeling tools must be developed to integrate spatial resolution and chemistry effects into fuel depletion tools to be able to account for these non-core sources of radioactivity. Such types of radiochemical transport analysis tools were used to estimate the removal rates for 12 elements within a flow model of the Molten Salt Reactor Experiment (MSRE) by optimizing against legacy experimental data of the gas-borne (GB) percentages of 12 nuclides. The removal rates were used in a depletion model to calculate the FP inventory that enters the MSRE OGS. Calculations are in good agreement with the empirical GB percentages reported for the 12 nuclides, which validates the approach and verifies each tool’s treatment of the radiochemical flow effects. The OGS inventory is discussed in terms of the largest nuclide contributors to activity, dose consequence, decay heat, and elemental composition. Finally, insights from the study allow recommendations to be made for future code development activities.

Shahbazi, Shayan↗

Analysis of Radiological Release From Fueled Irradiation Experiments During Manual Handling (Slides)

Irradiation experiments are manually handled at the Advanced Test Reactor (ATR) by qualified operators using long handled tools. Standard handling evolutions include insertion and removal from the reactor vessel, transfer to/from a storage location or cask in the ATR canal, and handling/reconfigurations at a canal working tray. Such routine handling has the potential to result in mechanical damage to the experiment boundary which is credited to retain fission products. Since damage can occur due to operator error, this is an anticipated occurrence. This work determines the radiological consequences to receptors inside the ATR facility, as well as public receptors. Given the wide variety of fuel types tested at the ATR, a generic approach to the analysis is taken. The radiological inventory is determined to bound a variety of fuel types (e.g., ceramic and molten fuel matrices) and fission powers on the U-235 enrichment spectrum. The source term analysis considers different release fractions to bound different fuel types and burnups. The postulated handling events occur underwater; thus, retention of the released isotopic content is considered within the canal water column. Retention of radionuclides in the water column is determined using a modified approach of United States (US) Nuclear Regulatory Commission (NRC) Regulatory Guide (RG) 1.183. Radiological dose to the facility receptor is determined using a compartment release model. Dose to the public receptor is determined using atmospheric dispersion models using site specific atmospheric conditions with the use of the Radiological Safety Analysis Computer (RSAC) program version 7.2.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Dose-dependent consequences of sub-chronic fentanyl exposure on neuron and glial co-cultures

Fentanyl is one of the most common opioid analgesics administered to patients undergoing surgery or for chronic pain management. While the side effects of chronic fentanyl abuse are recognized (e.g., addiction, tolerance, impairment of cognitive functions, and inhibit nociception, arousal, and respiration), it remains poorly understood what and how changes in brain activity from chronic fentanyl use influences the respective behavioral outcome. Here, we examined the functional and molecular changes to cortical neural network activity following sub-chronic exposure to two fentanyl concentrations, a low (0.01 μM) and high (10 μM) dose. Primary rat co-cultures, containing cortical neurons, astrocytes, and oligodendrocyte precursor cells, were seeded in wells on either a 6-well multi-electrode array (MEA, for electrophysiology) or a 96-well tissue culture plate (for serial endpoint bulk RNA sequencing analysis). Once networks matured (at 28 days in vitro ), co-cultures were treated with 0.01 or 10 μM of fentanyl for 4 days and monitored daily. Only high dose exposure to fentanyl resulted in a decline in features of spiking and bursting activity as early as 30 min post-exposure and sustained for 4 days in cultures. Transcriptomic analysis of the complex cultures after 4 days of fentanyl exposure revealed that both the low and high dose induced gene expression changes involved in synaptic transmission, inflammation, and organization of the extracellular matrix. Collectively, the findings of this in vitro study suggest that while neuroadaptive changes to neural network activity at a systems level was detected only at the high dose of fentanyl, transcriptomic changes were also detected at the low dose conditions, suggesting that fentanyl rapidly elicits changes in plasticity.

59 BASIC BIOLOGICAL SCIENCES↗