1393 Ring Bus at JPL: Description and Status

Completed Ring Bus IC V&V Phase - Ring Bus Test Plan Completed for SIM Project - Applicable to Other Projects Implemented a Avionics Bus Based upon the IEEE 1393 Standard - Excellent Starting Point for a General Purpose High-Speed Spacecraft Bus - Designed to Meet SIM Requirements for - Real-time deterministic, distributed systems. - Control system requirements - Fault detection and recovery Other JPL Projects Considering Implementation F'light Software Ring Bus Driver Module Began in 2006, Continues Participating in Standard Revision. Search for Earth-like planets orbiting nearby stars and measure the masses and orbits of the planets it finds. Survey 2000 nearby stars for planetary systems to learn whether our Solar System is unusual, or typical. Make a new catalog of star position 100 times more accurate than current measurements. Learn how our galaxy formed and will evolve by studying the dynamics of its stars. Critically test models of exactly how stars shine, including exotic objects like black holes, neutron stars and white dwarfs.

time synchronization↗

Advanced Sensor Deployment for Distribution System State Estimation and Fault Identification: Preprint

Distribution systems are currently facing steep operational challenges as a result of the rapidly increasing integration of renewables and other distributed energy resources (DERs)at both the primary and secondary circuit levels. Distribution utilities and system operators have traditionally had some visibility of their primary circuits using low-frequency supervisory control and data acquisition systems, and they have had very poor if not zero visibility of the secondary circuits where the presence of DERs is constantly increasing. Therefore, this paper presents simulation studies to demonstrate the benefits of an advanced, high-fidelity sensor technology, called as the Meta-Alert System (MAS), developed by Electrical Grid Monitoring Ltd. (EGM), on the distribution grid. First, a reliable model of the EGM sensors is developed, and then two use cases - distribution system state estimation (DSSE) and fault identification - are simulated to evaluate the performance of the MAS technology. Simulation results on the Electric Power Research Institute J1feeder demonstrate that the MAS can effectively participate in system-level DSSE programs and can detect and locate faults faster than traditional distribution protection schemes.

distribution system monitoring↗

Spatial-Temporal Recurrent Graph Neural Networks for Fault Diagnostics in Power Distribution Systems

Fault diagnostics are extremely important to decide proper actions toward fault isolation and system restoration. The growing integration of inverter-based distributed energy resources imposes strong influences on fault detection using traditional overcurrent relays. This paper utilizes emerging graph learning techniques to build new temporal recurrent graph neural network models for fault diagnostics. The temporal recurrent graph neural network structures can extract the spatial-temporal features from data of voltage measurement units installed at the critical buses. From these features, fault event detection, fault type/phase classification, and fault location are performed. Compared with previous works, the proposed temporal recurrent graph neural networks provide a better generalization for fault diagnostics. Moreover, the proposed scheme retrieves the voltage signals instead of current signals so that there is no need to install relays at all lines of the distribution system. Therefore, the proposed scheme is generalizable and not limited by the number of relays installed. The effectiveness of the proposed method is comprehensively evaluated on the Potsdam microgrid and IEEE 123-node system in comparison with other neural network structures.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Functional requirements for an intelligent RPC

An intelligent remote power controller (RPC) based on microcomputer technology can implement advanced functions for the accurate and secure detection of all types of faults on a spaceborne electrical distribution system. The intelligent RPC will implement conventional protection functions such as overcurrent, under-voltage, and ground fault protection. Advanced functions for the detection of soft faults, which cannot presently be detected, can also be implemented. Adaptive overcurrent protection changes overcurrent settings based on connected load. Incipient and high-impedance fault detection provides early detection of arcing conditions to prevent fires, and to clear and reconfigure circuits before soft faults progress to a hard-fault condition. Power electronics techniques can be used to implement fault current limiting to prevent voltage dips during hard faults. It is concluded that these techniques will enhance the overall safety and reliability of the distribution system.

Aucoin, B. M.↗

RAMP - A fault tolerant distributed microcomputer structure for aircraft navigation and control

Design methodologies for realizing future high authority autoflight control systems are being investigated, taking into account also the study of distributed microcomputer architectures. Attention is given to the redundant asynchronous microprocessor (RAMP) structure. RAMP comprises a connected network of microcomputers which has as input command and sensor information, and which generates servo information to drive actuators, and thrust linkages. Tolerance to hardware failures is achieved by static redundancy. Results of a failed microcomputer are simply rejected. This is done in lieu of dynamic redundancy wherein the distributed computer system performs real time fault detection and reconfiguration of the system. Attention is given to the RAMP network structure and operation, flight control with parallel asynchronous computers, and intermittent fault tolerance.

Dunn, W. R.↗

Flight elements subpanel introduction and overview

Major objectives, milestones, key contacts, technology issues, accomplishments, and candidate programs are outlined. Topics addressed include: advanced avionics systems architectures; advanced information processing; avionics concepts; integrated Global Positioning System/guidance, navigation, and command concepts; advanced communication and telemetry; display and control concepts; advanced sensors and instrumentation; fault detection and fault management; advanced electric power, distribution, and control; EMA/power systems; and in-flight crew training. This presentation is represented by viewgraphs only.

Sollock, Paul E.↗

A model-based executive for commanding robot teams

The paper presents a way to robustly command a system of systems as a single entity. Instead of modeling each component system in isolation and then manually crafting interaction protocols, this approach starts with a model of the collective population as a single system. By compiling the model into separate elements for each component system and utilizing a teamwork model for coordination, it circumvents the complexities of manually crafting robust interaction protocols. The resulting systems are both globally responsive by virtue of a team oriented interaction model and locally responsive by virtue of a distributed approach to model-based fault detection, isolation, and recovery.

domain compilations↗

Augmentation of the space station module power management and distribution breadboard

The space station module power management and distribution (SSM/PMAD) breadboard models power distribution and management, including scheduling, load prioritization, and a fault detection, identification, and recovery (FDIR) system within a Space Station Freedom habitation or laboratory module. This 120 VDC system is capable of distributing up to 30 kW of power among more than 25 loads. In addition to the power distribution hardware, the system includes computer control through a hierarchy of processes. The lowest level consists of fast, simple (from a computing standpoint) switchgear that is capable of quickly safing the system. At the next level are local load center processors, (LLP's) which execute load scheduling, perform redundant switching, and shed loads which use more than scheduled power. Above the LLP's are three cooperating artificial intelligence (AI) systems which manage load prioritizations, load scheduling, load shedding, and fault recovery and management. Recent upgrades to hardware and modifications to software at both the LLP and AI system levels promise a drastic increase in speed, a significant increase in functionality and reliability, and potential for further examination of advanced automation techniques. The background, SSM/PMAD, interface to the Lewis Research Center test bed, the large autonomous spacecraft electrical power system, and future plans are discussed.

Walls, Bryan↗

Roadmap for Advancement of Low-Voltage Secondary Distribution Network Protection

Downtown low-voltage (LV) distribution networks are generally protected with network protectors that detect faults by restricting reverse power flow out of the network. This creates protection challenges for protecting the system as new smart grid technologies and distributed generation are installed. This report summarizes well-established methods for the control and protection of LV secondary network systems and spot networks, including operating features of network relays. Some current challenges and findings are presented from interviews with three utilities, PHI PEPCO, Oncor Energy Delivery, and Consolidated Edison Company of New York. Opportunities for technical exploration are presented with an assessment of the importance or value and the difficulty or cost. Finally, this leads to some recommendations for research to improve protection in secondary networks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Toward Statistical Real-Time Power Fault Detection

We propose statistical fault detection methodology based on high-frequency data streams that are becoming available in modern power grids. Our approach can be treated as an online (sequential) change point monitoring methodology. However, due to the mostly unexplored and very nonstandard structure of high-frequency power grid streaming data, substantial new statistical development is required to make this methodology practically applicable. The paper includes development of scalar detectors based on multichannel data streams, determination of data-driven alarm thresholds and investigation of the performance and robustness of the new tools. Due to a reasonably large database of faults, we can calculate frequencies of false and correct fault signals, and recommend implementations that optimize these empirical success rates.

bolted faults↗

Electrical substation grid testbed for DLT applications of electrical fault detection, power quality monitoring, DERs use cases and cyber-events

Electrical utilities continue to deploy more intelligent electronic devices (IEDs) inside and outside electrical substation, and are associated with customer-owned distributed energy resources (DERs). The integrity and confidentiality of data from these IEDs, like power meters and protective relays, is crucial. Blockchain technology could improve the resilience of microgrids by improving the security of data sharing. The penetration of customer-owned DERs (renewable energy sources) and the increasing deployment of IEDs can lead to integrate power system applications with Distributed Ledger Technology (DLT). In this study, we implemented the electrical faulted phase detection and power quality monitoring algorithms with a Cyber Grid Guard (CGG) system using DLT. In addition, the DERs (wind turbine farms) use case and protective relay cyber-event tests were assessed, by using the CGG system with DLT. In the experimental model, the testbed was created by using a real-time simulator and CGG system with power meters/ protective relays in-the-loop. The data collected from the CGG system and IEDs were compared with the same time stamp source. These results had shown the successful assessment of protection, control and monitoring applications using a CGG system with DLT. In the future, the ESGT with DERs and the CGG system will be used in other power system applications, based on implementing smart contracts between electrical utilities with customer-owned DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A distributed programming environment for Ada

Despite considerable commercial exploitation of fault tolerance systems, significant and difficult research problems remain in such areas as fault detection and correction. A research project is described which constructs a distributed computing test bed for loosely coupled computers. The project is constructing a tool kit to support research into distributed control algorithms, including a distributed Ada compiler, distributed debugger, test harnesses, and environment monitors. The Ada compiler is being written in Ada and will implement distributed computing at the subsystem level. The design goal is to provide a variety of control mechanics for distributed programming while retaining total transparency at the code level.

Brennan, Peter↗

Wattile: Probabilistic Deep Learning-based Forecasting of Building Energy Consumption [SWR-20-94]

Accurate energy forecasting is becoming critical due to many reasons: i ) optimal distributed energy resources operations and dispatch, ii) fault detection and diagnostics, and iii) meeting operational energy efficiency targets. Wattile uses deep learning (DL) for the building's short-term load forecasting application. Two specific types of neural networks called, Long Short Term Memory (LSTM) and Sequence-to-Sequence (S2S) models are used to make predictions. Forecasting models are trained using online historical weather and occupancy indicator data streams from the Intelligent Campus Program's data acquisition systems at the National Renewable Energy Laboratory (NREL) for main meters and sub-meters of multiple building types. These models use probabilistic methods to provide quantile-based forecasts in addition to nominal conditional median predictions of electricity consumption.

Frank, Stephen↗

Fault Current Control and Protection in a Standalone DC Microgrid Using Adaptive Droop and Current Derivative

This report presents a novel fault detection, characterization, and fault current control algorithm for a standalone solar-photovoltaic (PV) based dc microgrids. The protection scheme is based on the current derivative algorithm. The overcurrent and current directional/differential comparison based protection schemes are incorporated for the dc microgrid fault characterization. For a low impedance fault, the fault current is controlled based on the current/voltage thresholds and current direction. Generally, the droop method is used to control the power-sharing between the converters by controlling the reference voltage. In this article, an adaptive droop scheme is also proposed to control the fault current by calculating a virtual resistance R droop , and to control the converter output reference voltage. For a high impedance fault, differential comparison method is used to characterize the fault. These algorithms effectively control the converter pulsewidth and reduce the flow of source current from a particular converter, which helps to increase the fault clearing time. Additionally, a trip signal is sent to the corresponding dc circuit breaker (DCCB), to isolate the faulted converter, feeder or a dc bus. The dc microgrid protection design procedure is detailed, and the performance of the proposed method is verified by simulation analysis.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Qualitative Event-Based Diagnosis: Case Study on the Second International Diagnostic Competition

We describe a diagnosis algorithm entered into the Second International Diagnostic Competition. We focus on the first diagnostic problem of the industrial track of the competition in which a diagnosis algorithm must detect, isolate, and identify faults in an electrical power distribution testbed and provide corresponding recovery recommendations. The diagnosis algorithm embodies a model-based approach, centered around qualitative event-based fault isolation. Faults produce deviations in measured values from model-predicted values. The sequence of these deviations is matched to those predicted by the model in order to isolate faults. We augment this approach with model-based fault identification, which determines fault parameters and helps to further isolate faults. We describe the diagnosis approach, provide diagnosis results from running the algorithm on provided example scenarios, and discuss the issues faced, and lessons learned, from implementing the approach

Daigle, Matthew↗

Towards a State Based Control Architecture for Large Telescopes: Laying a Foundation at the VLT

Large telescopes are characterized by a high level of distribution of control-related tasks and will feature diverse data flow patterns and large ranges of sampling frequencies; there will often be no single, fixed server-client relationship between the control tasks. the architecture is also challenged by the task of integrating heterogeneous subsystems which will be delivered by multiple different contractors. Due to the high number of distributed components, the control system needs to effectively detect errors and faults, impede their propagation, and accurately mitigate them in the shortest time possible, enabling the service to be restored. The presented Data-Driven Architecture is based on a decentralized approach with an end-to-end integration of disparate, independently developed software components. These components employ a high-performance standards-based communication middle-ware infrastructure, based on the Data Distribution Service. A set of rules and principles, based on JPL's State Analysis method and architecture, are use to constrain component-to component interactions, where the Control System and System Under Control are clearly separated. State Analysis provide a model-based process for capturing system and software requirements and design, greatly reducing the gap between the requirements on software specified by systems engineers and the implementation by software engineers. The method and architecture has been field tested at the Very Large Telescope, where it has been integrated into an operational system.

European Extremely Large Telescope (E-ELT)↗

Cascadia Subduction Zone Fault Heterogeneities From Newly Detected Small Magnitude Earthquakes

The Cascadia subduction zone (CSZ) is known to host M9 megathrust ruptures; however, no such event has occurred in historical observation. The distribution and characteristics of small- to moderate-sized earthquakes can be used to determine the behavior of the megathrust fault but are notably absent offshore the CSZ due to the distance from onshore seismometers. We use automated subspace detection coupled with an onshore-offshore seismic deployment to find small-magnitude earthquakes in the offshore seismogenic zone and analyze their locations in the context of interseismic locking and seismogenic zone extent. Here we detected and located 5,282 earthquakes, 4,096 of which had been previously undetected. We find that the downdip extent of the seismogenic zone as defined by interplate seismicity agrees with the 20% locking contour of the Schmalzle et al. (2014, https://doi.org/10.1002/2013GC005172) geodetic model and extends deeper than predicted by previous thermal models. We cannot determine the updip extent of the seismogenic zone; this may be due to a lack of templates for detection in the updip source area, stress shadows updip of asperity loading, and/or strong locking to the trench. We present a map of possible asperities determined by the small earthquakes in this study. Our asperity locations and extents show some, but not complete, agreement with the asperities modeled from the 1700 M9 rupture and geodetic locking models, and good agreement with the paleo-rupture extents determined from offshore turbidites and forearc basin-based asperity estimates. This highlights the need of continued offshore observations over time, and to elucidate fine-scale variation in locking.

58 GEOSCIENCES↗