Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “direct detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

High speed QPPM direct detection optical communication receivers for FSDD intersatellite links

This final report consists of four separate reports, one for each project involved in this contract. The first report is entitled '325 Mbps QPPM (quaternary pulse position modulation) Direct Detection Free Space Optical Communication Encoder and Receiver,' which was our primary work. The second report is entitled 'Test Results of the 325 Mbps QPPM High Speed Data Transmission GaAs ASICs,' which describes our work in connection with Galaxy Microsystems, Inc. who produced these ASICs for NASA. The third report, 'Receiver Performance Analysis of BPPM Optical Communication Systems Using 1.3 micron Wavelength Transmitter and InGaAs PIN Photodiodes,' was prepared at the request of the NASA/Photonics Branch for their efforts in upgrading the 1773 optical fiber data bus. The fourth report, 'Photomultiplier Tubes for Use at 1.064 micron Wavelength,' was also prepared at the request of the NASA/Photonics Branch as a research project.

Davidson, Frederic M.↗

Capacity, cutoff rate, and coding for a direct-detection optical channel

It is shown that when Pierce's pulse-position modulation scheme with 2 to the L power positions (where L is some positive integer) is used on a self-noise-limited direct-detection optical communication channel, there results a (2 to the L power)-ary erasure channel that is equivalent to the parallel combination of L completely correlated binary erasure channels. The capacity of the full channel is the sum of the capacities of the component channels, but the cutoff rate of the full channel is shown to be much smaller than the sum of the cutoff rates. An interpretation of the cutoff rate is given that suggests a complexity advantage in coding separately on the component channels. It is shown that if short-constraint length convolutional codes with Viterbi decoders are used on the component channels, then the performance and complexity compare favorably with the Reed-Solomon coding system proposed by McEliece (1979) for the full channel. The reasons for this unexpectedly fine performance by the convolutional code system are explored in detail, as are various facets of the channel structure.

Massey, J. L.↗

Receiver processing for direct-detection optical communication systems.

A model that is sufficiently general to describe the predominant statistical characteristics of the output of many real optical detectors is formulated. This model is used to study the optimum receiver processing for direct-detection optical communication systems. In particular, the structures of detectors and estimators for filtered doubly stochastic Poisson processes (DSPP) observed in additive white Gaussian noise are considered. Representations for the posterior statistics of a vector Markov process that modulates the intensity of the DSPP are obtained.

Hoversten, E. V.↗

2-Micron Pulsed Direct Detection IPDA Lidar for Atmospheric CO2 Measurement

A 2-micron high energy, pulsed Integrated Path Differential Absorption (IPDA) lidar has been developed for atmospheric CO2 measurements. Development of this lidar heavily leverages the 2-micron laser technologies developed in LaRC over the last decade. The high pulse energy, direct detection lidar operating at CO2 2-micron absorption band provides an alternate approach to measure CO2 concentrations. This new 2-micron pulsed IPDA lidar has been flown in spring of this year for total ten flights with 27 flight hours. It is able to make measurements of the total amount of atmospheric CO2 from the aircraft to the ground or cloud. It is expected to provide high-precision measurement capability by unambiguously eliminating contamination from aerosols and clouds that can bias the IPDA measurement.

Yu, Jirong↗

Design of a Direct-Detection Wind and Aerosol Lidar for Mars Orbit

The present knowledge of the Mars atmosphere is greatly limited by a lack of global measurements of winds and aerosols. Hence, measurements of height-resolved wind and aerosol profiles are a priority for new Mars orbiting missions. We have designed a direct-detection lidar (MARLI) to provide global measurements of dust, winds and water ice profiles from Mars orbit. From a 400-km polar orbit, the instrument is designed to provide wind and backscatter measurements with a vertical resolution of 2 km and with resolution of 2° in latitude along track. The instrument uses a single-frequency, seeded Nd:YAG laser that emits 4 mJ pulses at 1064 nm at a 250 Hz pulse rate. The receiver utilizes a 50-cm diameter telescope and a double edge Fabry-Pérot etalon as a frequency discriminator to measure the Doppler shift of the aerosol-backscatter profiles. The receiver also includes a polarization-sensitive channel to detect the cross-polarized backscatter profiles from water ice. The receiver uses a sensitive 4 × 4 pixel HgCdTe avalanche photodiode array as a detector for all signals. Here we describe the measurement concept, instrument design, and calculate its performance for several cases of Mars atmospheric conditions. The calculations show that under a range of atmospheric conditions MARLI is capable of measuring wind speed profiles with random error of 2–4 m/s within the first three scale heights, enabling vertically resolved mapping of transport processes in this important region of the atmosphere.

Cremons, Daniel R.↗

A Direct Detection LiDAR Detector for the Europa Lander Concept

NASA's Jet Propulsion Laboratory is developing a Europa Lander astrobiology mission concept to search for biosignatures within Europa’s subsurface. However, Europa’s rugged terrain presents a number of physical hazards for landing. MIT Lincoln Laboratory is designing a radiation-hardened real-time direct-detection LIDAR system at 532nm to aid with autonomous hazard avoidance and landing site selection for this Europa Lander concept. The detector for this system is a 2048x32 array of silicon Geiger-mode APDs and covers the required field-of-view in one dimension, removing the need for 2D stitching and enabling real-time data processing. Detector design, improvements for radiation tolerance and component characterization results are presented.

San Martin, Alejandro Miguel↗

Direct detection of the Yarkovsky effect by radar ranging to ateroid 6489 Golevka

Radar ranging from Arecibo, Puerto Rico, to the 0.5-kilometer near-Earth asteroid 6489 Golevka unambiguously reveals a small nongravitational acceleration caused by the anisotropic thermal emission of absorbed sunlight. The magnitude of this perturbation, known as the Yarkovsky effect, is a function of the asteroid's mass and surface thermal characteristics. Direct detection of the Yarkovsky effect on asteroids will help constrain their physical properties, such as bulk density, and refine their orbital paths.

asteriod mass radar orbital paths↗

Airborne, Direct-Detection, 2-μm Triple-Pulse IPDA Lidar for Simultaneous and Independent Atmospheric Water Vapor and Carbon Dioxide Active Remote Sensing

Atmospheric water vapor and carbon dioxide are important greenhouse gases that significantly contribute to the global radiation budget on Earth. A 2-micron triple-pulse, Integrated Path Differential Absorption (IPDA) lidar instrument for ground and airborne atmospheric carbon dioxide and water vapor concentration measurements using direct detection was developed at NASA Langley Research Center. This active remote sensing instrument provides an alternate approach with significant advantages for measuring atmospheric concentrations of the gases. A high energy pulsed laser transmitter approach coupled with sensitive receiver detection provides a high-precision measurement capability by having a high signal-to-noise ratio. This paper presents the concept, development, integration and testing of the 2-micron triple-pulse IPDA. The integration includes the various IPDA transmitter, receiver and data acquisition subsystems and components. Ground and airborne testing indicated successful operation of the IPDA lidar.

Refaat, Tamer F.↗

Micro-spec: an Integrated Direct-detection Spectrometer for Far-infrared Space Telescopes

The far-infrared and submillimeter portions of the electromagnetic spectrum provide a unique view of the astrophysical processes present in the early universe. Our ability to fully explore this rich spectral region has been limited, however, by the size and cost of the cryogenic spectrometers required to carry out such measurements.Micro-Spec (μ-Spec) is a high-sensitivity, direct-detection spectrometer concept working in the 450-1000 (micrometers) wavelength range which will enable a wide range of flight missions that would otherwise be challenging due tothe large size of current instruments with the required spectral resolution and sensitivity. The spectrometer design utilizes two internal antenna arrays, one for transmitting and one for receiving, superconducting microstrip transmission lines for power division and phase delay, and an array of microwave kinetic inductance detectors (MKIDs) to achieve these goals. The instrument will be integrated on a approximately 10 sq cm silicon chip and can therefore become an important capability under the low background conditions accessible via space and high-altitude borne platforms. In this paper, an optical design methodology for micro-Spec is presented, with particular attention given to its two-dimensional diffractive region, where the light of different wavelengths is focused on the different detectors. The method is based on the maximization of the instrument resolving power and minimization of the RMS phase error on the instrument focal plane. This two-step optimization can generate geometrical configurations given specific requirements on spectrometer size, operating spectral range and performance.Two point designs with resolving power of 260 and 520 and an RMS phase error less than approximately 0.004 radians were developed for initial demonstration and will be the basis of future instruments with resolving power up to about 1200.

Far-infrared↗

Micro-Spec: an Integrated, Direct-Detection Spectrometer for Far-Infrared and Submillimeter Astronomy

The far-infrared and submillimeter portions of the electromagnetic spectrum provide a unique view of the astrophysical processes present in the early universe. Our ability to fully explore this rich spectral region has been limited, however, by the size and cost of the cryogenic spectrometers required to carry out such measurements. Micro-Spec (u-Spec) is a high-sensitivity, direct-detection spectrometer concept working in the 450-1000 micromillimeter wavelength range which will enable a wide range of flight missions that would otherwise be challenging due to the large size of current instruments with the required spectral resolution and sensitivity. The spectrometer design utilizes two internal antenna arrays, one for transmitting and one for receiving, superconducting microstrip transmission lines for power division and phase delay, and an array of microwave kinetic inductance detectors (MKIDs) to achieve these goals. The instrument will be integrated on a approximately 10 square cm silicon chip and can therefore become an important capability under the low background conditions accessible via space and high-altitude borne platforms. In this paper, an optical design methodology for Micro-Spec is presented, with particular attention given to its twodimensional diffractive region, where the light of different wavelengths is focused on the different detectors. The method is based on the maximization of the instrument resolving power and minimization of the RMS phase error on the instrument focal plane. This two-step optimization can generate geometrical configurations given specific requirements on spectrometer size, operating spectral range and performance. A point design with resolving power of 257, an RMS phase error less than 0.1 radians and four stigmatic points was developed for initial demonstration and will be the basis of future instruments with resolving power up to about 1200.

microwave kinetic inductance detectors (MKIDs)↗

Atmospheric contributions to the column variance in direct-detection dial

One of the most important parameters of a Differential Absorption Lidar (DIAL) system is the delay time between the on and off resonant pulses. It is important that this delay time is sufficiently small to ensure that the atmosphere is effectively frozen between the pulses. Therefore, most Dial systems were designed with two lasers firing alternately less than 1 msec apart. Despite the importance of this parameter in the design of DIAL systems and its contribution to the overall error of a column measurement, very little is known about the size of the error for the case of a direct-detection system using atmospheric backscatter. The ultraviolet DIAL system uses two independent YAG/dye lasers and is therefore suitable for measuring the effects of different pulse delays on the variance of column measurements for a variety of atmospheric conditions. A set of DIAL returns were acquired with the two lasers tuned to the same wavelength and with a range of pulse delay times between 250 microseconds and several minutes. This data set was recorded in full on a computer and was used both to test different averaging techniques and also to evaluate atmospheric contributions to DIAL columns.

Milton, M. J. T.↗

Development of an Airborne Molecular Direct Detection Doppler Lidar for Tropospheric Wind Profiling

Global measurement of tropospheric winds is a key measurement for understanding atmospheric dynamics and improving numerical weather prediction. Global wind profiles remain a high priority for the operational weather community and also for a variety of research applications including studies of the global hydrologic cycle and transport studies of aerosols and trace species. In addition to space based winds, high altitude airborne Doppler lidar systems flown on research aircraft, UAV's or other advanced sub-orbital platforms would be of great scientific benefit for studying mesoscale dynamics and storm systems such as hurricanes. The Tropospheric Wind Lidar Technology Experiment (TWiLiTE) is a three year program to advance the technology readiness level of the key technologies and subsystems of a molecular direct detection wind lidar system by validating them, at the system level, in an integrated airborne lidar system. The TWiLiTE Doppler lidar system is designed for autonomous operation on the WB57, a high altitude aircraft operated by NASA Johnson. The WE357 is capable of flying well above the midlatitude tropopause so the downward looking lidar will measure complete profiles of the horizontal wind field through the lower stratosphere and the entire troposphere. The completed system will have the capability to profile winds in clear air from the aircraft altitude of 18 km to the surface with 250 m vertical resolution and < 3 mis velocity accuracy. Progress in technology development and status of the instrument design will be presented.

Gentry, Bruce↗

Lenslet Array to Further Suppress Star Light for Direct Exoplanet Detection

Direct imaging plays a key role in the detection and characterization of exoplanets orbiting within its host star's habitable zone. Many innovative ideas for starlight suppression and wavefront control have been proposed and developed over the past decade. However, several technological challenges still lie ahead to achieve the required contrast, including controlling the observatory pointing performance, fabricating occulting masks with tight optical tolerances, developing wavefront control algorithms, controlling stray light, advancing single photon detecting detectors, and integrated system-level issues. This paper explores how a lenslet array and pinhole mask may be implemented to further suppress uncorrected starlight that leaks through the occulting mask. An external occulter, or star shade, is simulated to demonstrate this concept, although this approach can be implemented for internal coronagraphs as well. We describe how to use simple relay optics to control the scene near the inner working angle and the level of the suppression expected. Furthermore, if the lenslet array is the input to an integral field spectrograph, as planned for the WFIRST mission, the spectral content of the exoplanet atmospheres can be obtained to determine if the observed planet is habitable and ultimately, if it is inhabited.

Integral Field spectrograph↗

Precluding nonlinear ISI in direct detection long-haul fiber optic systems

Long-distance, high-rate fiber optic systems employing directly modulated 1.55-micron single-mode lasers and conventional single-mode fiber suffer severe intersymbol interference (ISI) with a large nonlinear component. A method of reducing the nonlinearity of the ISI, thereby making linear equalization more viable, is investigated. It is shown that the degree of nonlinearity is highly dependent on the choice of laser bias current, and that in some cases the ISI nonlinearity can be significantly reduced by biasing the laser substantially above threshold. Simulation results predict that an increase in signal-to-nonlinear-distortion ratio as high as 25 dB can be achieved for synchronously spaced samples at an optimal sampling phase by increasing the bias current from 1.2 times threshold to 3.5 times threshold. The high SDR indicates that a linear tapped delay line equalizer could be used to mitigate ISI. Furthermore, the shape of the pulse response suggests that partial response precoding and digital feedback equalization would be particularly effective for this channel.

Swenson, Norman L.↗

Direct detection of XUV radiation with a CCD

A thinned CCD illuminated from the back has been used for direct imaging in the 584 and 304 A resonance lines of helium and in the 736 A line of neon. During operation, the CCD was cooled to minus 10 C and output was displayed on a CRT screen or in numerical printout. The results demonstrate that the back-illuminated CCD can be used as a position-sensitive flux detector with good imaging properties over a wide range of photon energies, including the extreme ultraviolet.

Burstein, P.↗

The Circumstellar Imager: Direct detection of extra-solar planetary systems

The Astrometric Imaging Telescope (AIT) is designed to probe the circumstellar environment by both direct imaging and indirect astrometric measurements. The Circumstellar Imager (CI) is a coronagraphic camera and is the direct imaging component of the AIT. The CI is designed to obtain high-sensitivity images of the circumstellar region. It provides crucial non-inferential information relating to the frequency, origin, and evolution of planetary systems and all forms of circumstellar matter. Such imaging is usually limited by the scattered and diffracted light halos of the star itself, which are greatly suppressed in the CI by mating a novel high-efficiency coronagraph with a phase-compensated optical system. For faint point sources in the circumstellar region, the CI will have a sensitivity in excess of 5 magnitudes fainter than the as-designed Hubble Space Telescope (HST). Laboratory data are shown for the coronagraph, which, in a diffraction-limited environment, is capable of suppressing the stellar diffraction sidelobes by several orders of magnitude without significant sacrifice of field of view. In order to realize the high rejection levels inherent in the coronagraph design, it is necessary to limit scatter in the optical systems, imposing a mid-spatial frequency figure error requirement an order of magnitude smaller than that of the HST. Experimental data directed toward meeting this requirement are also shown.

Ftaclas, Christ↗

Broadband Direct Detection Submillimeter Spectrometer with Multiplexed Superconducting Transition Edge Thermometer Bolometers

We present performance results based on the first astronomical use of multiplexed superconducting bolometers as direct detectors (i.e., with cold electrons) for spectroscopy. The Fabry-Perot Interferometer Bolometer Research Experiment (FIBRE) is a broadband submillimeter spectrometer for the Caltech Submillimeter Observatory (CSO). FIBRE's detectors are superconducting transition edge sensor (TES) bolometers read out by a SQUID multiplexer. The Fabry-Perot uses a low resolution grating to order sort the incoming light. A linear bolometer array consisting of 16 elements detects this dispersed light, capturing 5 orders simultaneously from one position on the sky. With tuning of the Fabry-Perot over one free spectral range, a spectrum covering Delta lambda/lambda = 1/7 at a resolution of delta lambda/lambda = 1/1200 can be acquired. This spectral resolution is sufficient to resolve Doppler-broadened line emission from external galaxies. FIBRE has been operated in the 350 Am (850 GHz) band. These bands cover line emission from the important star formation tracers neutral carbon [CI] and carbon monoxide (CO).

Benford, D. J.↗