Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “digital detector readout electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Development of an End-to-End Demonstration Readout Chain for Athena-X-IFU

The X-IFU (X-ray Integral Field Unit) of the Athena (Advanced Telescope for High-ENergy Astrophysics) telescope, scheduled for launch in the early 2030's, will provide X-ray spectroscopy data with unprecedented spectral and spatial resolution. This will be achieved by a 3 kilo-pixel array of TES (transition-edge sensor) microcalorimeters. The complete detection chain is under development by a large international collaboration. The detector array will be provided by NASA Goddard Space Flight Center, the cold TDM (time domain multiplexing) electronics by NIST, the cold amplifier by VTT, the cold focal-plane assembly by SRON, the warm front-end electronics by APC, and the DRE (digital readout electronics) by IRAP. In order to perform an end-to-end demonstration of the X-IFU readout chain, a 50 mK test bench is being developed at IRAP in collaboration with CNES. The test bench is based on a two-stage ADR cryostat from Entropy GmbH and a 1024-pixel array from Goddard associated with its cold TDM readout from NIST. The setup will initially be validated using a warm electronic chain from NIST and Goddard. We will describe the complete system being installed in the cryostat and the first results obtained with these electronics. We will also review the status of the integration of the DRE prototype in the demonstration chain and the way forward in the integration and testing of the complete X-IFU readout chain.

S Beaumont↗

Performance and characterization of the SPT-3G digital frequency-domain multiplexed readout system using an improved noise and crosstalk model

The third-generation South Pole Telescope camera (SPT-3G) improves upon its predecessor (SPTpol) by an order of magnitude increase in detectors on the focal plane. The technology used to read out and control these detectors, digital frequency-domain multiplexing (DfMUX), is conceptually the same as used for SPTpol, but extended to accommodate more detectors. A nearly 5× expansion in the readout operating bandwidth has enabled the use of this large focal plane, and SPT-3G performance meets the forecasting targets relevant to its science objectives. However, the electrical dynamics of the higher-bandwidth readout differ from predictions based on models of the SPTpol system due to the higher frequencies used and parasitic impedances associated with new cryogenic electronic architecture. To address this, we present an updated derivation for electrical crosstalk in higher-bandwidth DfMUX systems and identify two previously uncharacterized contributions to readout noise, which become dominant at high bias frequency. The updated crosstalk and noise models successfully describe the measured crosstalk and readout noise performance of SPT-3G. These results also suggest specific changes to warm electronics component values, wire-harness properties, and SQUID parameters, to improve the readout system for future experiments using DfMUX, such as the LiteBIRD space telescope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of a single area array detector for acquistion, tracking and point-ahead in space optical communications

Functions of acquisition, tracking, and point-ahead in space optical communications are being combined into a single system utilizing an area array detector. An analysis is presented of the feasibility concept. The key parameters are: optical power less than 1 pW at 0.86 micrometer, acquisition in less than 30 seconds in an acquisition field of view (FOV) of 1 mrad, tracking with 0.5 microrad rms noise at 1000 Hz update rate, and point ahead transfer function precision of 0.25 microrad over a region of 150 microrad. Currently available array detectors were examined. The most demanding specifications are low output noise, a high detection efficiency, a large number of pixels, and frame rates over 1kHz. A proof of concept (POC) demonstration system is currently being built utilizing the Kodak HS-40 detector (a 128 x 128 photodiode array with a 64 channel CCD readout architecture which can be operated at frame rates as high as 40,000/sec). The POC system implements a windowing scheme and special purpose digital signal processing electronic for matched filter acquisition and tracking algorithms.

Clark, D. L.↗

Application of a single area array detector for acquisition, tracking and point-ahead in space optical communications

Functions of acquisition, tracking, and point-ahead in space optical communications are being combined into a single system utilizing an area array detector. An analysis is presented of the feasibility concept. The key parameters are: optical power less than 1 pW at 0.86 micrometer, acquisition in less than 30 seconds in an acquisition field of view (FOV) of 1 mrad, tracking with 0.5 microrad rms noise at 1000 Hz update rate, and point ahead transfer function precision of 0.25 microrad over a region of 150 microrad. Currently available array detectors were examined. The most demanding specifications are low output noise, a high detection efficiency, a large number of pixels, and frame rates over 1kHz. A proof of concept (POC) demonstration system is currently being built utilizing the Kodak HS-40 detector (a 128 x 128 photodiode array with a 64 channel CCD readout architecture which can be operated at frame rates as high as 40,000/sec). The POC system implements a windowing scheme and special purpose digital signal processing electronic for matched filter acquisition and tracking algorithms.

Clark, D. L.↗

The Zero-Degree Detector System

We will report on a detector system used for accelerator measurement of nuclear fragmentation cross sections. This system consists of two detector planes, each carrying a ring of 8 detectors. Each detector has 64 pads. These two detector planes are arranged facing each other so that the matching detector pads on each plane form a two element charged particle telescope. Each of these telescopes is capable of determining the elemental identity of nuclear fragments passing through it. The system is used to measure light fragment production in the presence of heavier fragments. We will present a detailed discussion of the 64-pad detector design, the substrate design. The front-end electronics used to read out the signals is based on a custom VLSI chip developed for the Advanced Thin Ionization Calorimeter experiment which has been flown successfully twice in Antarctica. Each of these chips has 16 channels and each channel consists of a charge-sensitive preamplifier followed by a shaping amplifier and a track-and-hold circuit. The track-and-hold circuits are connected via a multiplexer to an output line driver. This allows the held signals to be presented, one-by-one via a common data line to a analog-to-digital converter. Because the output line driver can be placed in a high input impedance state when not in use, it is possible to daisy-change many chips on the same common data line. The front-end electronics and data readout scheme will be discussed in detail. The Zero Degree Detector has been used in several accelerator experiments conducted at the NASA Space Radiation Laboratory and the Alternating Gradient Synchrotron at Brookhaven National Laboratory as well as at the HIMAC accelerator in Japan. We will show examples of data taken at these accelerator runs to demonstrate how the system works.

Adams, James H.↗

The GALILEO γ-ray array at the Legnaro National Laboratories

GALILEO, a new 4 pi high-resolution gamma-detection array, based on HPGe detectors, has been developed and installed at the Legnaro National Laboratories. The GALILEO array greatly benefits from a fully-digital readout chain, customized DAQ, and a variety of complementary detectors to improve the resolving power by the detection of particles, ions or high-energy gamma-ray transitions. In this paper, a full description of the array, including electronics and DAQ, is presented together with its complementary instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-dimensional ultraviolet imagery with a microchannel-plate/resistive-anode detector

An imaging ultraviolet detector has been designed for use with a precision pointed telescope flown on a sounding rocket. Resolution of better than 80 microns over a field of 5 mm has been achieved. The ultraviolet image is converted to electrons at the front surface of a CsI coated chevron microchannel-plate electron multiplier. For each photoelectron, the multiplier produces a burst of about 3,000,000 electrons, which impinges on a tellurium-coated resistive anode with four evaporated hyperbolic readout electrodes. The sizes of the four resulting output pulses are digitized to 10 bit accuracy and telemetered to the ground, where they are divided in pairs to give the x and y coordinates of the photoelectron event. The coordinates are used to generate a picture in real time, and are recorded for computer processing later. The detector was successfully flown in December 1978. Good images of Jupiter and Capella in hydrogen Lyman alpha emission were obtained.

Opal, C. B.↗

A superconducting nanowire binary shift register

We present a design for a superconducting nanowire binary shift register, which stores digital states in the form of circulating supercurrents in high-kinetic-inductance loops. Adjacent superconducting loops are connected with nanocryotrons, three-terminal electrothermal switches, and fed with an alternating two-phase clock to synchronously transfer the digital state between the loops. A two-loop serial-input shift register was fabricated with thin-film NbN and a bit error rate of less than 10 –4 was achieved, when operated at a maximum clock frequency of 83 MHz and in an out-of-plane magnetic field of up to 6 mT. A shift register based on this technology offers an integrated solution for low-power readout of superconducting nanowire single photon detector arrays and is capable of interfacing directly with room-temperature electronics and operating unshielded in high magnetic field environments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Study of CMOS strip sensor for future silicon tracker

Monolithic silicon sensors developed with High-Voltage CMOS (HV-CMOS) processes have become highly attractive for charged particle tracking. Compared with the standard CMOS sensors, HV-CMOS sensors can provide larger and deeper depletion regions that lead to larger signals and faster charge collection. They can provide high position resolution, low material budget, high radiation hardness and low cost that are desirable for high performance tracking in harsh collision environment. Various studies have been conducted to explore the technology feasibility for the large-area tracking systems at future collider experiments. CHESS (CMOS HV/HR Evaluation for Strip Sensor) sensor series have been developed as an alternative solution to the conventional silicon micro-strip detectors for the ATLAS inner tracker upgrade. The first prototype (named CHESS1) was to evaluate the diode geometry and the in-pixel analog electronics. Obtained test results were used to optimize the second prototype (named CHESS2). CHESS2 was implemented with a full digital readout architecture and realized as a full reticle sized monolithic sensor. Here, the basic characteristics of the CHESS2 prototype sensors and their performance in response to different input signals are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geant4 Monte-Carlo (GEMC) A database-driven simulation program

GEMC[1] is an application that harnesses the power of databases to execute Geant4 Monte-Carlo simulations. The databases (MYSQL, CSQL, TEXT) define the geometry, materials, digitization algorithms, readout electronics and output formats. Implemented in C++, GEMC also boasts a user-friendly Python API that facilitates detector construction and database population. GEMC can handle real-life scenarios such as geometry variations and the run number-dependent calibration constants and digitization parameters. This abstract provides an overview of GEMC, accompanied by examples that showcase its versatility. We delve into the practical application of GEMC within the the CLAS12 experimental program at Jefferson Lab.

Ungaro, Maurizio↗

The large-area hybrid-optics CLAS12 RICH: First years of data-taking

The CLAS12 deep-inelastic scattering experiment at the upgraded 12 GeV continuous electron beam accelerator facility of Jefferson Lab conjugates luminosity and wide acceptance to study the 3D nucleon structure in the yet poorly explored valence region, and to perform precision measurements in hadron spectroscopy. A large area ring-imaging Cherenkov detector has been designed to achieve the required hadron identification in the momentum range from 3 GeV/c to 8 GeV/c, with the kaon rate about one order of magnitude lower than the rate of pions and protons. The adopted solution comprises aerogel radiator and composite mirrors in a novel hybrid optics design, where either direct or reflected light could be imaged in a high-packed and high-segmented photon detector. The first RICH module was assembled during the second half of 2017 and installed at the beginning of January 2018, in time for the start of the experiment. The second RICH module, planned with the goal to be ready for the beginning of the operation with polarized targets, has been timely built despite the complications caused by the pandemic crisis and successfully installed in June 2022. Finally, the detector performance is here discussed with emphasis on the operation and stability during the data-taking, calibration and alignment procedures, reconstruction and pattern recognition algorithms, and particle identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast, High-Precision Readout Circuit for Detector Arrays

The GEO-CAPE mission described in NASA's Earth Science and Applications Decadal Survey requires high spatial, temporal, and spectral resolution measurements to monitor and characterize the rapidly changing chemistry of the troposphere over North and South Americas. High-frame-rate focal plane arrays (FPAs) with many pixels are needed to enable such measurements. A high-throughput digital detector readout integrated circuit (ROIC) that meets the GEO-CAPE FPA needs has been developed, fabricated, and tested. The ROIC is based on an innovative charge integrating, fast, high-precision analog-to-digital circuit that is built into each pixel. The 128×128-pixel ROIC digitizes all 16,384 pixels simultaneously at frame rates up to 16 kHz to provide a completely digital output on a single integrated circuit at an unprecedented rate of 262 million pixels per second. The approach eliminates the need for off focal plane electronics, greatly reducing volume, mass, and power compared to conventional FPA implementations. A focal plane based on this ROIC will require less than 2 W of power on a 1×1-cm integrated circuit. The ROIC is fabricated of silicon using CMOS technology. It is designed to be indium bump bonded to a variety of detector materials including silicon PIN diodes, indium antimonide (InSb), indium gallium arsenide (In- GaAs), and mercury cadmium telluride (HgCdTe) detector arrays to provide coverage over a broad spectral range in the infrared, visible, and ultraviolet spectral ranges.

Rider, David M.↗

Improved noise performance from the next-generation buried-channel p-MOSFET SiSeROs

The Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors. Developed at MIT Lincoln Laboratory, this technology uses a p-MOSFET transistor with a depleted internal gate beneath the transistor channel. The transistor source-drain current is modulated by the transfer of charge into the internal gate. At Stanford, we have developed a readout module based on the drain current of the on-chip transistor to characterize the device. In our earlier work, we characterized a number of first prototype SiSeROs with the MOSFET transistor channels at the surface layer. An equivalent noise charge (ENC) of around 15 electrons root mean square (RMS) was obtained. In this work, we examine the first buried-channel SiSeRO. Here we have achieved substantially improved noise performance of around 4.5 electrons root mean square (RMS) and a full width half maximum (FWHM) energy resolution of 132 eV at 5.9 keV, for a readout speed of 625 kpixel/s. We also discuss how digital filtering techniques can be used to further improve the SiSeRO noise performance. Additional measurements and device simulations will be essential to further mature the SiSeRO technology. This new device class presents an exciting new technology for the next-generation astronomical X-ray telescopes requiring fast, low-noise, radiation-hard megapixel imagers with moderate spectroscopic resolution.

79 ASTRONOMY AND ASTROPHYSICS↗

RD53A: A large-scale prototype chip for the phase II upgrade in the serially powered HL-LHC pixel detectors

The phase II upgrade of the HL-LHC experiments within the LHC intends to deepen the studies of the Higgs boson and to allow the discovery of further particles by adding an integrated luminosity of about 4000 fb -1 over 10 years of operation. This upgrade would overwhelm the installed pixel detector readout chips with higher hit rates and radiation levels than ever before. To match these extreme requirements the RD53 collaboration, a joint effort between ATLAS and CMS, developed RD53A, a new generation pixel detector readout chip prototype manufactured in a 65 nm CMOS technology. It is half the size of the final pixel chips and designed to meet requirements in the face of 3 GHz/cm 2 hit rate after irradiation to 500 Mrad. The detector is able to use 50×50 μm 2 or 25×100 μm 2 pixels with high readout speed of up to 4 links per chip with 1.28 Gbit/s each. Shunt–LDO regulators integrated on the bottom of the chip provide the required voltages to the two power domains, analog and digital. These regulators enable serial powering of the pixel modules, which is the only feasible, radiation hard scheme to ensure acceptable power cable losses and to stay within the material budget for the future pixel detectors. Finally, an overview of the status and challenges of serial powering and the Shunt–LDO regulator development will be given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A PIPS + SrI 2 (Eu) detector for atmospheric radioxenon monitoring

The PIPS–SrI 2 (Eu) is a prototype atmospheric radioxenon detection system designed at Oregon State University in support of international efforts towards monitoring clandestine nuclear weapon testing activities. This detector aims to address some shortcomings found in currently deployed beta–gamma atmospheric radioxenon detection systems, such as lackluster energy resolution and memory effect, by employing modern detection materials and readout. The system uses a PIPSBox, a silicon-based gas cell, for electron detection, and a pair of ultrabright, D-shaped SrI 2 (Eu) scintillators coupled to silicon photomultipliers for photon detection. A custom eight-channel digital pulse processor equipped with a field programmable gate-array (FPGA) identifies electron–photon coincidences between the volumes in near real-time. Gas samples of the four radioxenon isotopes of interest were independently measured with the PIPS–SrI 2 (Eu) detection system to determine energy resolution and efficiency. Application of FPGA-based coincidence discrimination in near real-time reduced the ambient background count rate by 95.85 ± 0.04%. Using parameters from the Xenon International gas processing unit and assuming a blank sample and zero memory effect the minimum detectable concentrations (MDCs) for the isotopes were calculated to be 0.12 ± 0.03, 0.27 ± 0.05, 0.15 ± 0.02, and 1.00 ± 0.08 mBq/m 3 air for 131m Xe, 133 Xe, 133m Xe, and 135 Xe, respectively. These MDC estimates compare well with other radioxenon detection systems employed in the International Monitoring System (IMS) and indicate that the PIPS–SrI 2 (Eu) is in compliance with the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO) sensitivity requirement of ≤ 1 mBq/m 3 for 133 Xe.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial assessment of second generation of large-area picosecond photodetectors with multi-channel systems-on-a-chip readout

Here, we first briefly describe the history and motivation behind Cherenkov and scintillation light detection. We then discuss the instrumentation needed to detect these photons as it applies to both photodetectors and readout electronics. One of the motivations is future large neutrino detectors that could, in principle, differentiate between Cherenkov and scintillation light if using novel water-based scintillators. In this paper, we present the first measurements utilizing the second generation of Large Area Picosecond Photodetectors (LAPPDs) in conjunction with commercial system-on-a-chip readouts from Nalu Scientific—in particular, the High Density System on Chip (HDSoC) and Advanced ASoC Rapid Digitizer, Variable Adaptive Readout Chip (AARDVARC) platforms. These state-of-the-art full-waveform digitizers feature sampling rates on the order of 1 and 10 samples per nanosecond, respectively. Using a picosecond laser, we measured the timing jitter between a pair of LAPPD channels, demonstrating the potential of this setup for precise timing applications.

Li, V. A. [Lawrence Livermore National Laboratory ↗

Design and Modeling of the Charge Readout of a SiMOS Quantum Dot with a Single Electron Transistor and CryoCMOS

Single electron spin qubits trapped in SiMOS quantum dots are a promising technology for scaling to thousand- or million-qubit systems due to their compatibility with mature CMOS manufacturing processes. A readout system that combines a single electron transistor with a custom cryogenic CMOS amplification and digitization chain offers key advantages by avoiding the use of bulky RF components or room-temperature interconnects. We present design techniques and simulation results for an optimized qubit-SET cryoCMOS interface, culminating in the design of the QNDR1 ASIC, the first cryogenic readout ASIC designed under the Quandarum project, which targets the development of a many-channel spin qubit based detector for use in high energy physics.

Quinn, Adam [Fermilab] (ORCID:0009000605056371)↗

Fundamental and practical limitations of FUV/EUV photon-counting image detectors

In EUV and FUV space-astronomy applications, the best contemporary detector designs are based on the use of microchannel plates due to their ability to deliver photon-counting performance with high efficiency. The major unresolved issue is the choice of position-readout system for the individual photoevents. Electrical event-readout systems are divided into two classes: the discrete wire anodes that perform coordinate digitization by wire-group selection, and the continuous centroid-position encoders for which coordinates are digitized in the associated electronics. The centroid-position encoder techniques are discussed in terms of how they overcome the four chief limitations of the discrete-wire readouts - their limited format size, their flat focal surface, their fundamental hex-channel vs squared-pixel moire pattern, and their image undersampling. With these limitations overcome, microchannel based image systems can deliver the performance demanded by the forthcoming generation of applications in space astronomy.

Lampton, M.↗