Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “diffraction tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Mapping of axial strain in InAs/InSb heterostructured nanowires

The article presents a mapping of the residual strain along the axis of InAs/InSb heterostructured nanowires. Using confocal Raman measurements, we observe a gradual shift in the transverse optical phonon mode along the axis of these nanowires. We attribute the observed shift to a residual strain arising from the InAs/InSb lattice mismatch. We find that the strain is maximum at the interface and then monotonically relaxes towards the tip of the nanowires. We also analyze the crystal structure of the InSb segment through selected area electron diffraction measurements and electron diffraction tomography on individual nanowires.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ab initio structure determination of nanocrystals of organic pharmaceutical compounds by electron diffraction at room temperature using a Timepix quantum area direct electron detector

A specialized quantum area detector for electron diffraction studies makes it possible to solve the structure of small organic compound nanocrystals in non-cryo conditions by direct methods. Until recently, structure determination by transmission electron microscopy of beam-sensitive three-dimensional nanocrystals required electron diffraction tomography data collection at liquid-nitrogen temperature, in order to reduce radiation damage. Here it is shown that the novel Timepix detector combines a high dynamic range with a very high signal-to-noise ratio and single-electron sensitivity, enabling ab initio phasing of beam-sensitive organic compounds. Low-dose electron diffraction data (∼0.013 e{sup −} Å{sup −2} s{sup −1}) were collected at room temperature with the rotation method. It was ascertained that the data were of sufficient quality for structure solution using direct methods using software developed for X-ray crystallography (XDS, SHELX) and for electron crystallography (ADT3D/PETS, SIR2014)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Accurate measurement of relative tilt and azimuth angles in electron tomography: A comparison of fiducial marker method with electron diffraction

Electron tomography is a method whereby a three-dimensional reconstruction of a nanoscale object is obtained from a series of projected images measured in a transmission electron microscope. We developed an electron-diffraction method to measure the tilt and azimuth angles, with Kikuchi lines used to align a series of diffraction patterns obtained with each image of the tilt series. Since it is based on electron diffraction, the method is not affected by sample drift and is not sensitive to sample thickness, whereas tilt angle measurement and alignment using fiducial-marker methods are affected by both sample drift and thickness. The accuracy of the diffraction method benefits reconstructions with a large number of voxels, where both high spatial resolution and a large field of view are desired. The diffraction method allows both the tilt and azimuth angle to be measured, while fiducial marker methods typically treat the tilt and azimuth angle as an unknown parameter. The diffraction method can be also used to estimate the accuracy of the fiducial marker method, and the sample-stage accuracy. A nano-dot fiducial marker measurement differs from a diffraction measurement by no more than ±1°.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Slip localization behavior at triple junctions in nickel-base superalloys

Incipient slip localization in the vicinity of hundreds of grain boundary triple junctions (TJs) in a lightly deformed nickel-base superalloy IN718 is studied using a combination of three-dimensional (3D) crystal plasticity finite element (CPFE) modeling, high resolution digital image correlation (HR-DIC) and 3D electron back-scatter diffraction tomography (3D EBSD). A 3D reconstruction method enables identification of thousands of TJs and correspondence of any observed slip bands with their originating TJ lines below the specimen surface. Here, we present a large-scale CPFE model of the experimental 3D microstructure composed of high-fidelity representation of the TJ lines and the boundaries and interiors of the parent grains and use it to calculate the local micromechanical response and slip activity of all TJs at the onset of macroscopic yielding. Statistical analysis of the calculated quantities reveal TJs develop larger stress concentration and grain-average re-orientation than grain interiors and grain boundaries, however no substantial differences in cumulative slip were found among these microstructural regions. We find that TJs with observed slip bands generate lower grain-average re-orientation, fewer active slip systems, and more localized slip on a single system than those without. The distinctions in the reorientation and slip activity are stronger in TJs that experience more intense slip.

36 MATERIALS SCIENCE↗

A Rutile Chevron Modulation in Delafossite-Like Ga 3– x In 3 Ti x O 9+ x /2

The structure solution of the modulated, delafossite-related, orthorhombic Ga 3–x In 3 Ti x O 9+x/2 for x = 1.5 is reported here in conjunction with a model describing the modulation as a function of x for the entire system. Previously reported structures in the related A 3–x In 3 Ti x O 9+x/2 (A = Al, Cr, or Fe) systems use X-ray diffraction to determine that the anion lattice is the source of modulation. Neutron diffraction, with its enhanced sensitivity to light atoms, offers a route to solving the modulation and is used here, in combination with precession electron diffraction tomography (PEDT), to solve the structure of Ga 1.5 In 3 Ti 1.5 O 9.75 . We construct a model that describes the anion modulation through the formation of rutile chevrons as a function of x. This model accommodates the orthorhombic phase (1.5 ≤ x ≤ 2.1) in the Ga 3-x In 3 Ti x O 9+x/2 system, which transitions to a biphasic mixture (2.2 ≤ x ≤ 2.3) with a monoclinic, delafossite-related phase (2.4 ≤ x ≤ 2.5). The optical band gaps of this system are determined, and are stable at ~3.4 eV before a ~0.4 eV decrease between x = 1.9 and 2.0. After this decrease, stability resumes at ~3.0 eV. Resistance to oxidation and reduction is also presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pressure Heterogeneity and Material Utilization in Thin-Film Solid-State Cathodes

Intimate interfacial contact between the solid electrolyte and the cathode active material is critical for maximizing cathode utilization in solid-state batteries. However, volume changes during electrochemical cycling induce internal stresses that drive interfacial degradation, particularly under nonuniform stack pressure. In this study, we employ in situ energy-dispersive X-ray diffraction tomography to visualize and quantify reaction heterogeneities across a 3 mm-diameter solid-state cathode with a well-defined interface. Our results reveal that regions under a lower stack pressure exhibit reduced material utilization and reversibility, which negatively affect the high-pressure regions. Interfacial degradation further impedes lithium-ion transport and amplifies microscale reaction heterogeneity. These findings highlight the critical role of stack pressure distribution in governing interfacial stability and electrochemical performance, offering important design insights into practical solid-state battery systems.

36 MATERIALS SCIENCE↗

Exploring Cr and molten salt interfacial interactions for molten salt applications

Molten salts play an important role in various energy-related applications such as high-temperature heat transfer fluids and reaction media. However, the extreme molten salt environment causes the degradation of materials, raising safety and sustainability challenges. A fundamental understanding of material–molten salt interfacial evolution is needed. This work studies the transformation of metallic Cr in molten 50/50 mol% KCl–MgCl 2 via multi-modal in situ synchrotron X-ray nano-tomography, diffraction and spectroscopy combined with density functional theory (DFT) and ab initio molecular dynamics (AIMD) simulations. Notably, in addition to the dissolution of Cr in the molten salt to form porous structures, a δ-A15 Cr phase was found to gradually form as a result of the metal–salt interaction. This phase change of Cr is associated with a change in the coordination environment of Cr at the interface. DFT and AIMD simulations provide a basis for understanding the enhanced stability of δ-A15 Cr vs. bcc Cr, by revealing their competitive phase thermodynamics at elevated temperatures and probing the interfacial behavior of the molten salt at relevant facets. This study provides critical insights into the morphological and chemical evolution of metal–molten salt interfaces. Finally, the combination of multimodal synchrotron analysis and atomic simulation also offers an opportunity to explore a broader range of systems critical to energy applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Online Plug-and-Play Algorithm for Regularized Image Reconstruction

Plug-and-play priors (PnP) is a powerful framework for regularizing imaging inverse problems by using advanced denoisers within an iterative algorithm. Recent experimental evidence suggests that PnP algorithms achieve state-of-the-art performance in a range of imaging applications. Here, we introduce a new online PnP algorithm based on the proximal gradient method (PGM). The proposed algorithm uses only a subset of measurements at every iteration, which makes it scalable to very large datasets. We present a new theoretical convergence analysis, for both batch and online variants of PnP-PGM, for denoisers that do not necessarily correspond to proximal operators. We also present simulations illustrating the applicability of the algorithm to image reconstruction in diffraction tomography. Finally, the results in this paper have the potential to expand the applicability of the PnP framework to very large datasets.

97 MATHEMATICS AND COMPUTING↗

Concurrent determination of nanocrystal shape and amorphous phases in complex materials by diffraction scattering computed tomography

Advanced functional materials often contain multiple phases which are (nano)crystalline and/or amorphous. The spatial distribution of these phases and their properties, including nanocrystallite size and shape, often drives material function yet is difficult to obtain with current experimental techniques. This article describes the use of diffraction scattering computed tomography, which maps wide-angle scattering information onto sample space, to address this challenge. The wide-angle scattering signal contains information on both (nano)crystalline and amorphous phases. Rietveld refinement of reconstructed diffraction patterns is employed to determine anisotropic nanocrystal shapes. The background signal from refinements is used to identify contributing amorphous phases through multivariate curve resolution. Thus it is demonstrated that reciprocal space analysis in combination with diffraction scattering computed tomography is a very powerful tool for the complete analysis of complex multiphase materials such as energy devices.

Birkbak, Mie Elholm↗

Quantitative Scanning Transmission Electron Microscopy for Materials Science: Imaging, Diffraction, Spectroscopy, and Tomography

Scanning transmission electron microscopy (STEM) is one of the most powerful characterization tools in materials science research. Due to instrumentation developments such as highly coherent electron sources, aberration correctors, and direct electron detectors, STEM experiments can examine the structure and properties of materials at length scales of functional devices and materials down to single atoms. STEM encompasses a wide array of flexible operating modes, including imaging, diffraction, spectroscopy, and 3D tomography experiments. This review outlines many common STEM experimental methods with a focus on quantitative data analysis and simulation methods, especially those enabled by open source software. The hope is to introduce both classic and new experimental methods to materials scientists and summarize recent progress in STEM characterization. The review also discusses the strengths and weaknesses of the various STEM methodologies and briefly considers promising future directions for quantitative STEM research.

36 MATERIALS SCIENCE↗

Study on the morphology of bulk hydrides by synchrotron X-ray tomography

Highlights: • The first DCT measurements in zirconium using high energy X-rays is shown. • A modified Hough Transform algorithm brings orientation calculation to pixel level. • The hydride plate normals are clustered in the {0002} pole direction. - Abstract: The morphologies of hydrides was studied using synchrotron X-ray at the European Synchrotron Radiation Facility (ESRF) using Diffraction Contrast Tomography (DCT). Diffraction Contrast Tomography is a relatively new technique that uses simultaneous collection of tomographic and diffraction data to reconstruct the 3D microstructural volume; in this case precipitates and matrix grains, while providing crystallographic orientation of neighbouring matrix grains. Previously the method was limited to light metals such as Al or Mg (due to the use of 8–30 keV X-rays). Here we show the first DCT measurements in a high atomic number metal zirconium using high energy X-rays (60 keV).

36 MATERIALS SCIENCE↗

Correlated high-resolution x-ray diffraction photoluminescence and atom probe tomography analysis of continuous and discontinuous In x Ga 1-x N quantum wells

In this study, atom probe tomography (APT) is used to characterize the influence of hydrogen dosing duringGaN barrier growth on the indium distribution of In x Ga 1-x N quantum wells, and correlatedmicro-photoluminescence is used to measure changes in the emission spectrum and efficiency. We found that relative to the control growth, hydrogen dosing leads to a 50% increase in emission intensity arising from discontinuous quantum wells that are narrower, of lower indium content, and with more abrupt interfaces. Additionally, simulations of carrier distributions based on APT composition profiles indicate that the greater carrier confinement leads to an increased radiative recombination rate. Furthermore, APT analysis of quantum well profiles enables refinement of x-ray diffractionanalysis for more accurate nondestructive measurements of composition.

36 MATERIALS SCIENCE↗

Electron tomography imaging methods with diffraction contrast for materials research

Transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM) enable the visualization of three-dimensional (3D) microstructures ranging from atomic to micrometer scales using 3D reconstruction techniques based on computed tomography algorithms. This 3D microscopy method is called electron tomography (ET) and has been utilized in the fields of materials science and engineering for more than two decades. Although atomic resolution is one of the current topics in ET research, the development and deployment of intermediate-resolution (non-atomic-resolution) ET imaging methods have garnered considerable attention from researchers. This research trend is probably not irrelevant due to the fact that the spatial resolution and functionality of 3D imaging methods of scanning electron microscopy (SEM) and X-ray microscopy have come to overlap with those of ET. In other words, there may be multiple ways to carry out 3D visualization using different microscopy methods for nanometer-scale objects in materials. From the above standpoint, this review paper aims to (i) describe the current status and issues of intermediate-resolution ET with regard to enhancing the effectiveness of TEM/STEM imaging and (ii) discuss promising applications of state-of-the-art intermediate-resolution ET for materials research with a particular focus on diffraction contrast ET for crystalline microstructures (superlattice domains and dislocations) including a demonstration of in situ dislocation tomography.

36 MATERIALS SCIENCE↗

The Detection of Monoclinic Zirconia and Non-Uniform 3D Crystallographic Strain in a Re-Oxidized Ni-YSZ Solid Oxide Fuel Cell Anode

The solid oxide fuel cell (SOFC) anode is often composed of nickel (Ni) and yttria-stabilized zirconia (YSZ). The yttria is added in small quantities (e.g., 8 mol %) to maintain the crystallographic structure throughout the operating temperatures (e.g., room-temperature to >800 °C). The YSZ skeleton provides a constraining structural support that inhibits degradation mechanisms such as Ni agglomeration and thermal expansion miss-match between the anode and electrolyte layers. Within this structure, the Ni is deposited in the oxide form and then reduced during start-up; however, exposure to oxygen (e.g., during gasket failure) readily re-oxidizes the Ni back to NiO, impeding electrochemical performance and introducing complex structural stresses. In this work, we correlate lab-based X-ray computed tomography using zone plate focusing optics, with X-ray synchrotron diffraction computed tomography to explore the crystal structure of a partially re-oxidized Ni/NiO-YSZ electrode. These state-of-the-art techniques expose several novel findings: non-isotropic YSZ lattice distributions; the presence of monoclinic zirconia around the oxidation boundary; and metallic strain complications in the presence of variable yttria content. This work provides evidence that the reduction–oxidation processes may destabilize the YSZ structure, producing monoclinic zirconia and microscopic YSZ strain, which has implications upon the electrode’s mechanical integrity and thus lifetime of the SOFC.

25 ENERGY STORAGE↗