At least 55 records · Page 3

Improvements of VIIRS and MODIS Solar Diffuser and Lunar Calibration

Both VIIRS and MODIS instruments use solar diffuser (SD) and lunar observations to calibrate their reflective solar bands (RSB). A solar diffuser stability monitor (SDSM) is used to track the SD on-orbit degradation. On-orbit observations have shown similar wavelength-dependent SD degradation (larger at shorter VIS wavelengths) and SDSM detector response degradation (larger at longer NIR wavelengths) for both VIIRS and MODIS instruments. In general, the MODIS scan mirror has experienced more degradation in the VIS spectral region whereas the VIIRS rotating telescope assembly (RTA) mirrors have seen more degradation in the NIR and SWIR spectral region. Because of this wavelength dependent mirror degradation, the sensor's relative spectral response (RSR) needs to be modulated. Due to differences between the solar and lunar spectral irradiance, the modulated RSR could have different effects on the SD and lunar calibration. In this paper, we identify various factors that should be considered for the improvements of VIIRS and MODIS solar and lunar calibration and examine their potential impact. Specifically, we will characterize and assess the calibration impact due to SD and SDSM attenuation screen transmission (uncertainty), SD BRF uncertainty and onorbit degradation, SDSM detector response degradation, and modulated RSR resulting from the sensor's optics degradation. Also illustrated and discussed in this paper are the calibration strategies implemented in the VIIRS and MODIS SD and lunar calibrations and efforts that could be made for future improvements.

VIIRS↗

Is the Narrow E-Peak Distribution of Gamma-Ray Bursts Real?

Over the performance period of the research grant, the authors conducted a study of the role that the detector response plays in the detection of gamma-ray bursts. The goal of the study was to determine whether the fact that the gamma-ray bursts observed by the BATSE instrument on the Compton Gamma-ray Observatory are characterized by approximately the same characteristic energy is a consequence of the instrument's characteristics, or whether the distribution is a physical attribute of gamma-ray bursts. The authors succeeded in showing that instrumental effects are mild, and that the observed characteristic energy is a physical attribute of bursts. In the course of this research, the authors ported the computer code for calculating the BATSE detector response matrices to the Sun Solaris platform, and created a version of the code that runs under any platform that supports a Fortran 77 compiler with DEC extensions. This code has already been used by other investigators to analyze BATSE data. The authors constructed a Monte Carlo simulation of the BATSE burst trigger, with which they determined the efficiency of detecting a burst as a function of characteristic burst spectral energy. The results were then applied to BATSE observations to determine the physical model for the distribution of burst characteristic energies.

Brainerd, Jerome J.↗

Thin-film scintillators for extended ultraviolet /UV/ response silicon detectors

The preparation and radiometric properties of silicon detectors coated with fluorescent thin films are described. The films are deposited from solutions of clear plastics, such as acrylic resins, polyvinyl toluene or polystyrene, and of organic laser dyes in a common solvent. They are optically clear, mechanically and chemically stable, yet easily applied and removed. Multiple doped films of a few microns thickness exhibit broad-band absorption from less than 250 nm to about 450 nm and narrow band emissions with peaks ranging from 380 nm to 600 nm. Internal quantum efficiencies are close to 100 percent and fluorescence decay times are in the nanosecond range. When deposited on optically denser media, a large fraction of the fluorescent emission is trapped in the substrate. Silicon photodiodes coated with multiple doped films exhibit high external quantum efficiencies and virtually flat photon response in the near UV.

Viehmann, W.↗

Far Infrared Spectroscopy of (O III) in M82

Emission lines at 52 and 88 micron from O III in the galaxy M82 were observed with the cooled grating spectrometer aboard the Kuiper Airborne Observatory. Raw spectra were corrected for telluric water vapor absorption, instrument response function, and relative detector response by ratioing to a spectrum of Saturn or Mars taken on the same flight. An average electron density Pn regions where oxygen is doubly ionized was derived. The electron density calculated for M 82 is significantly lower than those found in the galaxy using the same method. Results suggest that observations of the galaxy made from a great distance would yield a higher electron density than observed in M82.

Duffy, P.↗

Numerical Filtering of Spurious Transients in a Satellite Scanning Radiometer: Application to CERES

The Clouds and Earth Radiant Energy System (CERES) scanning, radiometer was designed to provide high accuracy measurements of the radiances from the earth. Calibration testing of the instruments showed the presence of all undesired slow transient in the measurements of all channels at 1% to 2% of the signal. Analysis of the data showed that the transient consists of a single linear mode. The characteristic time of this mode is 0.3 to 0.4 s and is much greater than that the 8-10-ms response time of the detector, so that it is well separated from the detector response. A numerical filter was designed for the removal of this transient from the measurements. Results show no trace remaining of the transient after application of the numerical filter. The characterization of the slow mode on the basis of ground calibration data is discussed and flight results are shown for the CERES instruments aboard the Tropical Rainfall Measurement Mission and Terra spacecraft. The primary influence of the slow mode is in the calibration of the instrument and the in-flight validation of the calibration. This method may be applicable to other radiometers that are striving for high accuracy and encounter a slow spurious mode regardless of the underlying physics.

Smith, G. Louis↗

On-Orbit Noise Characterization for MODIS Reflective Solar Bands

Since launch, the Moderate Resolution Imaging Spectroradiometer (MODIS) has operated successfully on-board the NASA Earth Observing System (EOS) Terra and EOS Aqua spacecraft. MODIS is a passive cross-track scanning radiometer that makes observations in 36 spectral bands with spectral wavelengths from visible (VIS) to long-wave infrared. MODIS bands 1-19 and 26 are the reflective solar bands (RSB) with wavelengths from 0.41 to 2.2 micrometers. They are calibrated on-orbit using an on-board solar diffuser (SD) and a SD stability monitor (SDSM) system. For MODIS RSB, the level 1B calibration algorithm produces top of the atmosphere reflectance factors and radiances for every pixel of the Earth view. The sensor radiometric calibration accuracy, specified at each spectral band's typical scene radiance, is 2% for the RSB reflectance factors and 5% for the RSB radiances. Also specified at the typical scene radiance is the detector signal-to-noise ratio (SNR), a key sensor performance parameter that directly impacts its radiometric calibration accuracy and stability, as well as the image quality. This paper describes an on-orbit SNR characterization approach developed to evaluate and track MODIS RSB detector performance. In order to perform on-orbit SNR characterization, MODIS RSB detector responses to the solar illumination reflected from the SD panel must be corrected for factors due to variations of the solar angles and the SD bi-directional reflectance factor. This approach enables RSB SNR characterization to be performed at different response levels for each detector. On-orbit results show that both Terra and Aqua MODIS RSB detectors have performed well since launch. Except for a few noisy or inoperable detectors which were identified pre-launch, most RSB detectors continue to meet the SNR design requirements and are able to maintain satisfactory short-term stability. A comparison of on-orbit noise characterization results with results derived from pre-launch calibration and characterization are also provided.

Xiong, X.↗

Microwave characteristics of GaAs MMIC integratable optical detectors

Interdigitated photoconductive detectors were fabricated on microwave device structures, making them easily integratable with Monolithic Microwave Integrated Circuits (MMIC). Detector responsivity as high as 2.5 A/W and an external quantum efficiency of 3.81 were measured. Response speed was nearly independent of electrode geometry, and all detectors had usable response at frequencies to 6 GHz. A small signal model of the detectors based on microwave measurements was also developed.

Claspy, Paul C.↗

Fast Neutron Spectroscopy with Organic Scintillation Detectors in a High-Radiation Environment

Organic scintillators with pulse shape discrimination capability are widely used in both research and practical applications of neutron detection. The neutron and gamma-ray identification performance of the detector depends on the classification algorithms, noise filters and pileup rejection criteria in a high-flux bremsstrahlung radiation environment. In this paper, a technique has been developed and implemented for the neutron detection with multiple filter and discrimination steps, which to a high confidence level eliminates counting of gamma-ray pulses. Such a technique is merited when making measurements in a high flux bremsstrahlung and secondary fluorescence environment. The EJ-309 and stilbene detectors coupled to the digital data acquisition system were used for the calibration assessments with standard gamma-ray and neutron sources such as 137Cs, 60Co, 252Cf, and Am-Be. The MCNPX-PoliMi and GEANT4 toolkits were used to simulate the light output and the optical photon transport in the scintillators and create detector response functions for each type of detector. The neutron spectrum unfolding algorithm, GRAVELW, was used to recreate and calibrate with the Am-Be as final step before applying the neutron detection system to extract fusion neutron spectra generated in an intense bremsstrahlung radiation environment. This new technique described offers the user the ability to measure neutron spectra in a high-flux gamma-ray field and tune the parameters to meet required filtering needs.

Neutron Detector, Organic Scintillator, PulseShape↗

Imaging Calorimeter for ACCESS Simulations with GEANT/FLUKA

Imaging Calorimeter for ACCESS (ICA) is a candidate of the calorimeter for the NASA's ACCESS program. The ICA studies the origin and acceleration mechanism of cosmic rays by measuring the elemental composition of the cosmic rays in the energy up to 10(exp 16) eV. For the past year, Monte Carlo simulation study for the ICA has been conducted to predict the detector performance and to design the system for match the scientific objectives. Simulation results show that the detector response resembles a Gaussian distribution and the energy resolution with ICA can be achieved about 40%. In addition, simulations of the detector's response to an assumed bent power law spectra in the region where the knee occurs have been conducted and clearly show that this detector can provide sufficiently accurate estimates of the spectral parameters that are a science goal of ACCESS.

Lee, Jeongin↗

Spectral response from blackbody measurements

Far-infrared and submillimeter detector responsivity and spectral response measurements can be performed simultaneously by sweeping the temperature of a cooled blackbody. Such measurements yield n simultaneous linear equations for n blackbody temperatures. Matrix inversion solutions are observed to fail due to a matrix ill-conditioned for inversion. However, an unconditionally convergent iterative solution can be performed. Results for a gallium-doped germanium detector are described.

Moore, W. J.↗

Design Improvements and X-Ray Performance of a Time Projection Chamber Polarimeter for Persistent Astronomical Sources

The design of the Time-Projection Chamber (TPC) Polarimeter for the Gravity and Extreme Magnetism Small Explorer (GEMS) was demonstrated to Technology Readiness Level 6 (TRL-6)3 and the flight detectors fabricated, assembled and performance tested. A single flight detector was characterized at the Brookhaven National Laboratory Synchrotron Light Source with polarized X-rays at 10 energies from 2.3-8.0 keV at five detector positions. The detector met all of the GEMS performance requirements. Lifetime measurements have shown that the existing flight design has 23 years of lifetime4, opening up the possibility of relaxing material requirements, in particular the consideration of the use of epoxy, to reduce risk elsewhere. We report on design improvements to the GEMS detector to enable a narrower transfer gap that, when operated with a lower transfer field, reduces asymmetries in the detector response. In addition, the new design reduces cost and risk by simplifying the assembly and reducing production time. Finally, we report on the performance of the narrow-gap detector in response to polarized and unpolarized X-rays.

GEMS↗

Gated photomultiplier response characterization for DIAL measurements

The characteristics of various detector responses are studied to understand the cause of various systematic biases and to minimize these undesirable effects in measurements of transient signals with large dynamic range. Signal-induced bias, gain variation, and the linearity of commonly used gated photomultipliers in the current integrating mode are quantitatively evaluated. Analysis of the results indicates that impurity ions inside the photomultiplier tubes (PMT) are the source of the signal induced bias and gain variation. Two different PMTs used in this study show significant differences in the magnitude and decay behavior of signal-induced bias. It was found that it can be minimized by using an external amplifier to reduce PMT gain, and by applying a low potential between the cathode and first dynode. The linearity of a PMT is also studied over a large dynamic range of input intensities employing a new technique which does not require an absolute calibration. The result of this study shows that the photomultiplier response is linear only for a limited input intensity range below a certain anode current.

Lee, H. Sang↗

Results from Solar Reflective Band End-to-End Testing for VIIRS F1 Sensor Using T-SIRCUS

Verification of the Visible Infrared Imager Radiometer Suite (VIIRS) End-to-End (E2E) sensor calibration is highly recommended before launch, to identify any anomalies and to improve our understanding of the sensor on-orbit calibration performance. E2E testing of the Reflective Solar Bands (RSB) calibration cycle was performed pre-launch for the VIIRS Fight 1 (F1) sensor at the Ball Aerospace facility in Boulder CO in March 2010. VIIRS reflective band calibration cycle is very similar to heritage sensor MODIS in that solar illumination, via a diffuser, is used to correct for temporal variations in the instrument responsivity. Monochromatic light from the NIST T-SIRCUS was used to illuminate both the Earth View (EV), via an integrating sphere, and the Solar Diffuser (SD) view, through a collimator. The collimator illumination was cycled through a series of angles intended to simulate the range of possible angles for which solar radiation will be incident on the solar attenuation screen on-orbit. Ideally, the measured instrument responsivity (defined here as the ratio of the detector response to the at-sensor radiance) should be the same whether the EV or SD view is illuminated. The ratio of the measured responsivities was determined at each collimator angle and wavelength. In addition, the Solar Diffuser Stability Monitor (SDSM), a ratioing radiometer designed to track the temporal variation in the SD BRF by direct comparison to solar radiation, was illuminated by the collimator. The measured SDSM ratio was compared to the predicted ratio. An uncertainty analysis was also performed on both the SD and SDSM calibrations.

McIntire, Jeff↗

Effects of ionizing radiation on cryogenic infrared detectors

The Diffuse Infrared Background Experiment (DIRBE) is one of three experiments to be carried aboard the Cosmic Background Explorer (COBE) satellite scheduled to be launched by NASA on a Delta rocket in 1989. The DIRBE is a cryogenic absolute photometer operating in a liquid helium dewar at 1.5 K. Photometric stability is a principal requirement for achieving the scientific objectives of this experiment. The Infrared Astronomy Satellite (IRAS), launched in 1983, which used detectors similar to those in DIRBE, revealed substantial changes in detector responsivity following exposure to ionizing radiation encountered on passage through the South Atlantic Anomaly (SAA). Since the COBE will use the same 900 Km sun-synchronous orbit as IRAS, ionizing radiation-induced performance changes in the detectors were a major concern. Here, ionizing radiation tests carried out on all the DIRBE photodetectors are reported. Responsivity changes following exposure to gamma rays, protons, and alpha particle are discussed. The detector performance was monitored following a simulated entire mission life dose. In addition, the response of the detectors to individual particle interactions was measured. The InSb photovoltaic detectors and the Blocked Impurity Band (BIB) detectors revealed no significant change in responsivity following radiation exposure. The Ge:Ga detectors show large effects which were greatly reduced by proper thermal annealing.

Moseley, S. H.↗

Evaluation of radiation interference in the Voyager Sun Sensor's cadmium sulfide detector

The simulation of radiation interference effects and the results of a radiation interference test on two Voyager Sun Sensor prototype detector assemblies are reported. The derivation of test levels and requirements are discussed and show that cobalt 60 gamma radiation is an effective and practical simulator of the ionization dose rate effects induced by high-energy electron flux incident on the spacecraft at a rate of 3.7 x 10 to the 8th e/sq cm-sec (10 rad(Si)/s) during closest approach to Jupiter. The test results provide information that is used to confirm an analytic correlation, and to predict satisfactory performance of a spacecraft sun sensing device having stringent angular resolution requirements. The measured detector response shows that at dose rates incident on the detector elements of 2 rad(Si)/sec, which is four times that expected during Jupiter encounter, the radiation-induced angle error is almost an order of magnitude less than that allowed by the acceptance criteria.

Clarke, T. C.↗

Characterization of NTD germanium and ion-implanted Si bolometers at 0.3K and 0.1K

Bolometer elements were built and tested using NTD germanium and ion-implanted Si thermometer elements. The thermal links were made using aluminum wires and NbC(x)N(y) coated carbon fibers. The temperature dependence of the detector resistance, lead thermal conductivity, and heat capacity were measured. The dependence of the detector resistance on applied electric field was also measured. This, combined with the current-voltage curve for the detector, allowed the calculation of the detector responsivity. Known amounts of energy were deposited into the detector by allowing X-rays from the decay of Fe-55 to be thermalized in the detector. In the best-measured case, the predicted pulse height/measured height was 1.04 + or - .05. The noise at frequencies above 25 Hz in the NTD Ge was near that predicted by thermodynamics. The noise below 25 Hz has a 1/f character and may be in the carbon fiber/bolometer junction. The implanted detectors show some 1/f noise which depends on the total thermometer volume. Comparison between noise measurements and theory will be presented.

Moseley, H.↗