Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detector response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Demonstrating and Expanding DRiFT’s Helium-3 Detector Response Capabilities [Slides]

Helium-3 tubes are an efficient way to detect neutrons after they have thermalized by polyethylene. They are often arranged in rings to perform coincidence counting. Applications include nuclear safeguards, treaty verification, and emergency response. DRiFT has the ability to simulate pile-up, room return, and end effects. A new feature determines real and accidental correlated counts. The next steps include DRiFT 2.0 released as executable, continued demonstration of gas module capabilities, and semiconductor module under a development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing the Electromagnetic Response of the NOvA Detectors

The NOvA Test Beam Program was commissioned to complement the full-scale NOvA experiment in its goal of measuring neutrino oscillations. The NOvA Experiment consists of a 300-ton Near Detector and a 14-kton Far Detector, both exposed to the same beam, which can be operated in neutrino or antineutrino mode from Fermilab at an off-axis angle of 14.6~mrad. These detectors can discriminate between $\nu_\mu$-CC and $\nu_e$-CC neutrino (or corresponding antineutrino) events, enabling appearance and disappearance measurements of these flavors across the \SI{810}{\kilo\meter} near-to-far detector baseline. From these measurements, the underlying parameters of the three-flavor PMNS oscillations framework are measured. The NOvA Test Beam uses identical technology to the full-scale detectors, but scaled down to 30~tons. It is exposed to a beam of charged particles closely matched to the daughter products of NOvA (anti)neutrino interactions in both energy and species. An instrumented beamline determines both particle momentum and species upstream of the NOvA detector, allowing for a crisp measurement of the NOvA detector response to these known inputs. This dissertation presents an analysis of the electromagnetic response of the NOvA hardware and establishes a framework for incorporating these results to enhance the physics reach of the experiment. Prior to this work, the electromagnetic energy response of the NOvA detector relied primarily on simulation-driven calibration together with a globally applied energy scale uncertainty. The measurements presented here provide direct test beam constraints on the detector response, enabling particle-dependent and potentially energy-dependent uncertainty models derived from controlled electromagnetic inputs.

Myers, Dalton Grant [U. Texas, Austin (main)] (ORC↗

Spectrum Unfolding with the MC-15

The Multiplicity Counter 15 tube detector or MC-15 is an optimized detector designed for use in the field. It is composed of 15 3 He tubes embedded in high density polyethylene (HDPE). Recent work has explored expanding the use of the MC-15 beyond multiplicity counting to neutron dosimetry applications. Knowledge of the neutron energy spectrum information is required to use a detector as a neutron dosimeter. The MC-15 tube layout is shown in Figure 1. The unique layout makes it possible to use the detector for neutron spectroscopy via spectrum unfolding. Spectrum unfolding requires (1) energy dependence of the detector response, (2) a detector response matrix that precisely quantifies the response to mono-energetic neutrons, (3) an initial guess spectrum, (4) an unfolding algorithm, and (5) measured data (counts in the case of the MC-15). An energy dependent detector response matrix (DRM) can be constructed by considering either each of the three rows of 3 He tubes as a distinct detector or each individual tube as a distinct detector. The HDPE separating the 3 He in the MC-15 provides the distinct energy dependent response for the rows and individual tubes. In this report we detail the development of detector response matrices for the MC-15 and the application of the Los Alamos Unfolding Code (LUC) to both simulated and measured data. Three MC-15 orientations were studied: (1) standard orientation with the MC-15 front facing the source, (2) standard orientation with Cd sheet, (3) 90° orientation with the side of the MC-15 facing the source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo Simulation of Background and Source Measurements with CSG and CAD Geometries

Detecting radioactive sources in an urban environment is difficult due to the large magnitude and variability of the background radiation. To support the search mission of the National Nuclear Security Administration, a project was undertaken to determine if first-principles modeling and simulation could be used to accurately predict the response of radiation detectors in urban environments. This study demonstrates that the simulated detector responses to photon radiation from both an isotopic source and the background compare well to benchmark-quality measurements in a large urban-like test environment. Simulation results using a traditional combinatorial solid geometry and a CAD model generated from LiDAR measurements gave very similar detector responses. With this validation, further simulations could be used to predict detector responses for various situations in real urban settings.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The response of covered silicon detectors to monoenergetic gamma rays

Measurements were made of the efficiency in detecting gamma rays of a 0.3-mm, a 3-mm, and a 5-mm silicon detector covered with different absorbers. Calibrated sources covering the range from 279 KeV to 2.75 MeV were used. The need for the absorbers in order to obtain meaningful results, and their contribution to detector response at electron biases from 50 to 200 KeV, are discussed in detail. It is shown that the results are independent of the atomic number of the absorber. In addition, the role of the absorber in increasing the efficiency with increasing photon energy for low bias setting is demonstrated for the 0.3-mm crystal. Qualitative explanations are given for the shapes of all curves of efficiency versus energy at each bias.

Reier, M.↗

Low background spectral response of 30-130-micron detectors from blackbody measurements

Low background far infrared detector responsivity and low background spectral response calibrations can be performed simultaneously with a cooled, temperature-swept blackbody. This makes the use of a cooled, low background spectrometer unnecessary in many applications. Calibrations of a beryllium-doped germanium detector showing unwanted 100-micron response, and of a gallium-doped germanium detector, are described.

Moore, W. J.↗