Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “design validations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Design and Validation of a High-Temperature Comparative Thermal-Conductivity Measurement System

A measurement system has been designed and built for the specific application of measuring the effective thermal conductivity of a composite, nuclear-fuel compact (small cylinder) over a temperature range of 100 C to 800 C. Because of the composite nature of the sample as well as the need to measure samples pre- and postirradiation, measurement must be performed on the whole compact non-destructively. No existing measurement system is capable of obtaining its thermal conductivity in a non-destructive manner. The designed apparatus is an adaptation of the guardedcomparative-longitudinal heat flow technique. The system uniquely demonstrates the use of a radiative heat sink to provide cooling which greatly simplifies the design and setup of such high-temperature systems. The design was aimed to measure thermalconductivity values covering the expected range of effective thermal conductivity of the composite nuclear fuel from 10W {center_dot} m{sup -1} {center_dot} K{sup -1} to 70W {center_dot} m{sup -1} {center_dot} K{sup -1}. Several materials having thermal conductivities covering this expected range have been measured for system validation, and results are presented. A comparison of the results has been made to data from existing literature.Additionally, an uncertainty analysis is presented finding an overall uncertainty in sample thermal conductivity to be 6%, matching well with the results of the validation samples.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Horizontal Split Table Conceptual Design for Validation of Nuclear Data used in Advanced Reactors [Slides]

This presentation discusses a methodology that was developed to create conceptual designs of benchmark critical experiments for advanced reactors and nuclear data testing. A first concept that was explored was a pebble-bed high-temperature gas cooled reactor, based on the HTR-10 reactor. The very high correlation is a proof of concept that the design is similar to the application, and performing such critical experiments would help nuclear data testing and validation. Other concepts could be explored if needed, such as a molten-salt reactor, a sodium-cooled fast reactor, or heat pipe reactors/microreactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design and validation of an MR-conditional robot for transcranial focused ultrasound surgery in infants

Purpose: Current treatment of intraventricular hemorrhage (IVH) involves cerebral shunt placement or an invasive brain surgery. Magnetic resonance-guided focused ultrasound (MRgFUS) applied to the brains of pediatric patients presents an opportunity to treat IVH in a noninvasive manner, termed “incision-less surgery.” Current clinical and research focused ultrasound systems lack the capability to perform neonatal transcranial surgeries due to either range of motion or dexterity requirements. A novel robotic system is proposed to position a focused ultrasound transducer accurately above the head of a neonatal patient inside an MRI machine to deliver the therapy. Methods: A clinical Philips Sonalleve MRgFUS system was expanded to perform transcranial treatment. A five degree-of-freedom MR-conditional robot was designed and manufactured using MR compatible materials. The robot electronics and control were integrated into existing Philips electronics and software interfaces. The user commands the position of the robot with a graphical user interface, and is presented with real-time MR imaging of the patient throughout the surgery. The robot is validated through a series of experiments that characterize accuracy, signal-to-noise ratio degeneration of an MR image as a result of the robot, MR imaging artifacts generated by the robot, and the robot’s ability to operate in a representative surgical environment inside an MR machine. Results: Experimental results show the robot responds reliably within an MR environment, has achieved 0.59 ± 0.25 mm accuracy, does not produce severe MR-imaging artifacts, has a workspace providing sufficient coverage of a neonatal brain, and can manipulate a 5 kg payload. A full system demonstration shows these characteristics apply in an application environment. Conclusions: This paper presents a comprehensive look at the process of designing and validating a new robot from concept to implementation for use in an MR environment. An MR conditional robot has been designed and manufactured to design specifications. The system has demonstrated its feasibility as a platform for MRgFUS interventions for neonatal patients. The success of the system in experimental trials suggests that it is ready to be used for validation of the transcranial intervention in animal studies.

60 APPLIED LIFE SCIENCES↗

Design Load Analysis for Wave Energy Converters: Preprint

This study demonstrates a systematic methodology for establishing the design loads of a wave energy converter (WEC). The proposed design load methodology incorporates existing design guidelines, where they exist, and follows a typical design progression; namely, advancing from many, quick, order-of-magnitude accurate, conceptual stage design computations to a few, computationally intensive, high-fidelity, design validation simulations. The goal of the study is to streamline and document this process based on quantitative evaluations of the design loads' accuracy at each design step and consideration for the computational efficiency of the entire design process. For the WEC, loads, and site conditions considered, this study demonstrates an efficient and accurate methodology of evaluating the design loads.

16 TIDAL AND WAVE POWER↗

Design and Validation of Mechanical & Autonomous Systems in Harsh Environments [Poster]

The autonomous systems within the Mobile Hot Cell provide advanced capabilities over traditional hot cells, pushing the boundaries of these systems in harsh environments. The degraded state of some radiological devices and the variety of designs present a series of challenges that require innovative tooling and procedural solutions. By leveraging technical knowledge and experience from disposition experts at SwRi and other institutions, initial design concepts were produced using rapid prototyping techniques. These concepts were then validated and optimized in a non-hazardous test bed, resulting in iterative improvements at minimal cost.

07 - ISOTOPES AND RADIATION SOURCES↗

Computational discovery of ultra-strong, stable, and lightweight refractory multi-principal element alloys. Part II: comprehensive ternary design and validation

Abstract Here the discovery of refractory multi-principal element alloys (MPEAs) with high-temperature strength and stability is pursued within a constrained and application-relevant design space. A comprehensive approach is developed and applied to explore all 165 ternary systems in the Al-Ce-Fe-Hf-Mo-Nb-Ta-Ti-V-W-Zr family. A subset of ternary systems that contain large areas in composition–temperature space with high strength and robust BCC phase stability is found. Twelve sets of high-performing alloys are identified, each set optimized for one combination of phase constraint, optimization target, and temperature range. Preliminary mechanical tests support the viability of the method. This work highlights the importance of considering phase stability, exploring non-equiatomic regions of composition space, and applying application-relevant constraints. Parts I and II provide three down-selection techniques for identifying high-performing BCC refractory MPEAs, design guidelines, and many candidates predicted to have BCC phase stability and strengths 2–3 times higher than any reported to date.

36 MATERIALS SCIENCE↗

Design and validation of a nanosecond short-wave infrared streak camera using gaseous detonation experiments

A custom short-wave infrared (SWIR) galvanometric streak camera was developed to provide nanosecond- scale, time-resolved optical diagnostics. The system was designed as a compact, mechanically driven alternative to traditional tube-based streak cameras, using a galvanometer mirror and multiple-reflection optical path to achieve high temporal resolution while maintaining electronic synchronization for trigger sequencing. Temporal resolution achieved 139.5 ns/px, allowing direct conversion of image-slope gradients to physical wave velocities. The instrument was validated using hydrogen-oxygen-argon detonations within a modular detonation tube, capturing transient emission structures and post-detonation decay behavior with microsecond precision. Although signal levels in filtered configurations were limited by lens transmission and detector sensitivity, the system successfully resolved intensity rise and decay characteristics across 10-60 % argon mixtures. The observed trends demonstrate the feasibility of compact galvanometer-based streak systems for high-speed SWIR imaging in reactive environments!

42 ENGINEERING↗

Search for Dark Matter with the LZ Experiment

Overwhelming evidence from astrophysical observations indicates that only 20% of the matter in the universe consists of ordinary matter, while the remaining 80% is made of some form of matter called "dark matter''. Although these indirect astrophysical observations convince us that dark matter exists, dark matter has not yet been directly observed. The standard model of particle physics, which has been very successful in explaining the properties of ordinary matter, can neither explain dark matter's presence nor its properties. The discovery and identification of dark matter would have a profound impact on cosmology, astronomy, and particle physics. A leading dark matter candidate consistent with all astrophysical data is a weakly interacting massive particle (WIMP). WIMPs could be detected through their interactions with atomic nuclei in specially designed detectors. Since the collision rates are expected to be very small (a few collisions per year for a 1-ton detector), large detectors with low backgrounds and excellent detection capability for rare collisions are needed to gain knowledge of the nature of dark matter. With dark matter experiments such as the LZ experiment, we are in a position to detect and study this dark matter through sensitive terrestrial direct detection experiments. If no discovery is made with LZ, it will be very difficult to reconcile the sensitivity limit of this experiment with most conventional WIMP scenarios, and alternate paradigms will have to be strongly considered for dark matter. The main focus of the U-M dark matter group over the past two years was on design validation and fabrication for the LZ project, followed by commissioning and operation of the LZ dark matter experiment, and the analysis of the science data during the following funding cycle. The U-M dark matter group had identified two key areas to contribute to the LZ project: the design and fabrication of a radon removal element for the xenon circulation system, and the execution and coordination of prototyping and design validation performed by the small xenon chamber group.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Data for NB6 HBRR Science Design ORNL/TM-2025/3807

Data for the report (ORNL/TM-2025/3807) that describes the calculations and the Monte Carlo Ray Tracing simulations performed using the McStas package to determine the coatings and geometry for the NB-6 guide. It provides the information to inform the mechanical design, validation tests and verification that it meets the science requirements.

47 OTHER INSTRUMENTATION↗

Design and Validation Testing of TruckScan to Assay Large Sacks of Fukushima Radioactive Debris on a Truck

As a result of the March 2011 earthquake and resulting tsunami in Japan, there was a serious accident at the Fukushima Dai-ichi Nuclear Power Plant. This accident has contaminated soil and vegetation in a wide area around the plant. Decontamination projects over the last 4 years have resulted in large numbers of 1 cubic meter canvas bags of debris, commonly called Super Sacks [SS]. These are currently stored nearby where they were generated, but starting in 2015, they will be moved to various Interim Storage Facilities [ISF]. Trucks will typically carry 8-20 of these SSs. When the trucks arrive at the ISF they need to be rapidly sorted into groups according to radioactivity level, for efficient subsequent processing. Canberra Industries, Inc. [CI] has designed a new truck monitoring system 'TruckScan' for use at these ISFs. The TruckScan system must measure the entire truck loaded with multiple closely packed SSs, and generate a nuclide specific assay report showing the radioactivity in each individual SS. The Canberra-Japan office, along with Obayashi Corporation have performed validation testing to demonstrate to the regulatory authorities that the proposed technique was sufficiently accurate. These validation tests were conducted at a temporary storage area in Fukushima prefecture. Decontaminated waste of various representative types and of various levels of radioactivity was gathered and mixed to create homogeneous volumes. These volumes were sampled multiple times and assayed with laboratory HPGe detectors to determine the reference concentration of each pile. Multiple SSs were loaded from each pile. Some of the SSs were filled 50% full, others 75% full, and others 100% full, to represent the typical loading configuration of the existing SSs in the field. The content of the SSs are either sand, soil, or vegetation with densities ranging from 0.3 g/cc - 1.6 g/cc. These SSs with known concentrations of Cs-134 and Cs-137 were then loaded onto trucks in a variety of configurations, typical of how they might be on the real trucks. A partial system was installed at the site and used to assay these trucks with the various loading configurations. Whereas the full system will have 8 collimated 3 x 3'' NaI detectors, the test system only had two detectors; therefore the truck was moved and counted 4 times. The data were acquired and analyzed with the Canberra Genie software to determine the peak counts for both Cesium nuclides. That data was then analyzed with a prototype version of a Maximum Entropy algorithm, to determine the individual SS activity. The goal of the validation tests was to demonstrate that the system could detect 1000 Bq/kg in 15 seconds, and to determine how accurately it could quantify individual SSs. The validation tests demonstrated that the product would perform as predicted. The TruckScan results were consistent with the sample assay results [y = 1.0029 x, R{sup 2} = 0.914]. The Total Propagated Uncertainty, including both uncertainties from these tests and others that were estimated but not tested was 16.6% percent. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design and validation of a high-voltage levitation circuit for electrostatic accelerometers

A simple high-voltage circuit with a voltage range of 0 to 900 V and an open-loop bandwidth of 11 kHz is realized by using an operational amplifier and a MOSFET combination. The circuit is used for the levitation of a test mass of 71 g, suspended below the top-electrodes with a gap distance of 57 μm, so that the performance of an electrostatic accelerometer can be tested on the ground. The translation noise of the accelerometer, limited by seismic noise, is about 4 × 10{sup −8} m/s{sup 2}/Hz{sup 1/2} at 0.1 Hz, while the high-voltage coupling noise is one-order of magnitude lower.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and validation of the ball-pen probe for measurements in a low-temperature magnetized plasma

Ball-pen probes have been used in fusion devices for direct measurements of the plasma potential. Their application in low-temperature magnetized plasma devices is still subject to studies. In this context, a ball-pen probe has been recently implemented on the linear plasma device Mirabelle. Produced by a thermionic discharge, the plasma is characterized by a low electron temperature and a low density. Plasma confinement is provided by an axial magnetic field that goes up to 100 mT. The principle of the ball-pen probe is to adjust the saturation current ratio to 1 by reducing the electron current contribution. In that case, the floating potential of the probe is close to the plasma potential. A thorough study of the ball-pen probe operation is performed for different designs of the probe over a large set of plasma conditions. Comparisons between ball-pen, Langmuir, and emissive probes are conducted in the same plasma conditions. The ball-pen probe is successfully measuring the plasma potential in these specific plasma conditions only if an adapted electronics and an adapted probe size to the plasma characteristic lengths ({lambda}{sub D}, {rho}{sub ce}) are used.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and Validation of In-Source Atmospheric Pressure Photoionization Hydrogen/Deuterium Exchange Mass Spectrometry with Continuous Feeding of D{sub 2}O

In this study, continuous in-source hydrogen/deuterium exchange (HDX) atmospheric pressure photoionization (APPI) mass spectrometry (MS) with continuous feeding of D{sub 2}O was developed and validated. D{sub 2}O was continuously fed using a capillary line placed on the center of a metal plate positioned between the UV lamp and nebulizer. The proposed system overcomes the limitations of previously reported APPI HDX-MS approaches where deuterated solvents were premixed with sample solutions before ionization. This is particularly important for APPI because solvent composition can greatly influence ionization efficiency as well as the solubility of analytes. The experimental parameters for APPI HDX-MS with continuous feeding of D{sub 2}O were optimized, and the optimized conditions were applied for the analysis of nitrogen-, oxygen-, and sulfur-containing compounds. The developed method was also applied for the analysis of the polar fraction of a petroleum sample. Thus, the data presented in this study clearly show that the proposed HDX approach can serve as an effective analytical tool for the structural analysis of complex mixtures. .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Exometabolomics Assisted Design and Validation of Synthetic Obligate Mutualism

Synthetic microbial ecology has the potential to enhance the productivity and resiliency of biotechnology processes compared to approaches using single isolates. Engineering microbial consortia is challenging; however, one approach that has attracted significant attention is the creation of synthetic obligate mutualism using auxotrophic mutants that depend on each other for exchange or cross-feeding of metabolites. In this paper, we describe the integration of mutant library fitness profiling with mass spectrometry based exometabolomics as a method for constructing synthetic mutualism based on cross-feeding. Two industrially important species lacking known ecological interactions, Zymomonas mobilis and Escherichia coli, were selected as the test species. Amino acid exometabolites identified in the spent medium of Z. mobilis were used to select three corresponding E. coli auxotrophs (proA, pheA and IlvA), as potential E. coli counterparts for the coculture. A pooled mutant fitness assay with a Z. mobilis transposon mutant library was used to identify mutants with improved growth in the presence of E. coli. An auxotroph mutant in a gene (ZMO0748) with sequence similarity to cysteine synthase A (cysK), was selected as the Z. mobilis counterpart for the coculture. Exometabolomic analysis of spent E. coli medium identified glutathione related metabolites as potentially available for rescue of the Z. mobilis cysteine synthase mutant. Three sets of cocultures between the Z. mobilis auxotroph and each of the three E. coli auxotrophs were monitored by optical density for growth and analyzed by flow cytometry to confirm high cell counts for each species. Taken together, our methods provide a technological framework for creating synthetic mutualisms combining existing screening based methods and exometabolomics for both the selection of obligate mutualism partners and elucidation of metabolites involved in auxotroph rescue.

59 BASIC BIOLOGICAL SCIENCES↗