Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “degradation diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Modeling of a spatially resolved ion temperature diagnostic for inertial confinement fusion

Here, the performance of modern laser-driven inertial confinement fusion (ICF) experiments is degraded by contamination of the deuterium–tritium (DT) fuel with high-Z material during compression. Simulations suggest that this mix can be described by the ion temperature distribution of the implosion, given that such contaminants deviate in temperature from the surrounding DT plasma. However, existing neutron time-of-flight (nTOF) diagnostics only measure the spatially integrated ion temperature. This paper describes the techniques and forward modeling used to develop a novel diagnostic imaging system to measure the spatially resolved ion temperature of an ICF implosion for the first time. The technique combines methods in neutron imaging and nTOF diagnostics to measure the ion temperature along one spatial dimension at yields currently achievable on the OMEGA laser. A detailed forward model of the source and imaging system was developed to guide instrument design. The model leverages neutron imaging reconstruction algorithms, radiation hydrodynamics and Monte Carlo simulations, optical ray tracing, and more. The results of the forward model agree with the data collected on OMEGA using the completed diagnostic. The analysis of the experimental data is still ongoing and will be discussed in a separate publication.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cell degradation quantification—a performance metric-based approach

A safe and reliable battery operation needs effective diagnostic tools. A quantitative failure analysis (FA) to enable cell qualification and quantify its effectiveness for reliable and safe operation of rechargeable Li batteries (RLB) is shown here. The method can identify and quantify potential failure based on the state of charge (SOC) under any operating conditions. A precise and accurate electrochemical analytic diagnosis (eCAD) of 14 rechargeable Li || NMC622 cells of the same build are used as an example. The FA by eCAD can quantitatively decipher good, bad and ugly cells in cycle aging. The cell qualification is based on thermodynamic SOC, not experimental conditions. The method provides a quantitative failure mode and effect analysis (FMEA) to reveal diverse “dead Li” formation that affects the reversibility of the Li anode and charge retention in the cell. This cell qualification method highlights the potential to improve cell quality for safe operation, with strong implications for early fault detection, FA, risk mitigation, state estimation and life prediction for reliable and safe RLB operations

25 ENERGY STORAGE↗

Automatic Calibration and Health Monitoring of Infrastructure Sensors

Smart transportation infrastructure relies on networks of heterogeneous sensors - cameras, radars, and lidars - continuously monitoring traffic conditions. However, executing the initial spatial calibration of multiple sensors and the subsequent health monitoring presents significant operational challenges. Environmental factors, mechanical vibrations, and gradual drift cause spatial misalignment, degrading fusion performance and tracking accuracy. Traditional calibration approaches require manual intervention with specialized targets or survey equipment, resulting in service interruptions and high maintenance costs. This work presents an automated framework for initial calibration and continuous health monitoring without human intervention or service disruption. Our approach addresses two critical problems: (1) detecting when sensors become miscalibrated during operation, and (2) automatically re-establishing spatial alignment using only operational traffic data. The health monitoring component analyzes measurement innovations - differences between sensor observations and predicted object states - to detect systematic biases indicative of calibration drift. By computing bias magnitude, directional consistency, and rejection rates, the system identifies miscalibrations as small as 0.5 meters. Unlike traditional methods requiring known calibration targets, our diagnostic operates continuously on live traffic observations, enabling early detection before fusion quality degrades. The automatic recalibration algorithm leverages overlapping sensor fields-of-view and temporal correlation of vehicle observations. Using graph-based optimization, the system automatically discovers which sensor pairs observe common regions, estimates pairwise spatial transformations using RANSAC-based robust estimation, and jointly optimizes all sensor poses through bundle adjustment. The framework handles practical deployment challenges, including different sensor sampling rates (1-10 Hz), varying installation positions, unknown orientations, and limited overlap regions (>10%). When approximate sensor positions are available from installation surveys (+/-1m accuracy), the algorithm additionally estimates sensor orientations, refining both position and rotation to sub-meter and sub-degree accuracy. We validate the framework on multi-hour traffic datasets from six heterogeneous sensors with sampling rates ranging from 1 Hz to 10 Hz. Results demonstrate successful calibration even with sparse overlap (<20%) and automatic detection of miscalibrations exceeding 0.8 meters. This work enables a "deploy-and-forget" sensor infrastructure that maintains calibration autonomously, reducing maintenance costs while improving tracking accuracy. The techniques generalize beyond transportation to any multi-sensor monitoring application requiring robust spatial alignment, including smart cities, industrial monitoring, and surveillance systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Diagnostics, Prognostics, and Optimization for Lithium-Ion Battery Systems

Health management of lithium-ion battery systems presents a host of challenges due to their complex physics, large numbers of components, and a wide variety of degradation behaviors across different battery types. Dr. Paul Gasper will present on research from the Electrochemical Energy Storage Group on Lithium-ion battery diagnostics, prognostics, and optimization. Diagnostics research, including state-estimation via machine-learning from electrochemical impedance spectroscopy and DC pulses as well as continuous state-estimation via Kalman filters, will highlight the ongoing challenges for accurately measuring the state of batteries without performing time-consuming characterization tests. NLR's industry-recognized battery prognostics work, which predicts real-world battery degradation by identifying degradation rate models from accelerated aging data using statistical modeling and machine-learning, will be used to demonstrate the critical impact of battery controls, thermal management, and operating strategy on durability and lifetime. Finally, the use of prognostic models for financial or lifetime optimization will be discussed.

25 ENERGY STORAGE↗

A physics-based parametric regression approach for feedwater pump system diagnosis

Here in this paper, we assessed the performance of a model-based approach for fault diagnosis of a nuclear power plant feedwater pump system. Physics-based models were constructed to monitor the performance of the system components. Plant data were used for the calibration of the models and subsequently in the diagnosis of abnormal events. We considered two real-time events representing scenarios of a pump fault and component performance degradation. The two events were correctly diagnosed, and the results demonstrated the high detection sensitivity of the physics-based models. Various sensor fault scenarios were simulated to show the capability of the approach to detect and uniquely identify sensor faults. Results for a scenario in which the plant operated in flexible power mode also showed that the diagnostic approach is insensitive to changes of operating conditions, which is one of the advantages of the model-based approach using physics-based models over purely data-driven approach.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Impact of Operational Strategies and Load Fluctuations on Anion Exchange Membrane Water Electrolyzer Degradation

This study reports on the durability of anion exchange membrane water electrolyzers (AEMWEs) at the cell level in a supporting electrolyte (1 M) and the impact of operational profiles on cell degradation. While constant load shows significant voltage loss, including a current hold at 1 A cm −2 and a potential hold at 2 V, it generally occurs in the first 70 h of testing. These losses are likely due to passivation altering site reactivity and cell kinetics, and are largely recoverable upon load cycling and diagnostics at the end of test. Furthermore, square and triangular-wave cycling do not show cell degradation and indicate that AEMWEs are not vulnerable to load cycling. When operating outside of this potential window (1.45–2 V), cell voltage decay rates markedly increase and the losses are not recoverable. This includes a current density hold at 4.0 A cm −2 with high cell voltages (>2.4 V for test duration) and cycling between 0 and 2 V to simulate start–stop, where more than a 50% loss in current density occurs over 50 h. The findings presented here demonstrate the high durability of AEMWEs, particularly when operating with load fluctuations, and may allow for durability advantages compared to iridium and proton exchange membrane systems.

08 HYDROGEN↗

Nondestructive Characterization of Antireflective Coatings on PV Modules

Antireflective coatings (ARCs) are used on the vast majority of solar photovoltaic (PV) modules to increase power production. However, ARC longevity can vary from less than 1 to over 15 years depending on coating quality and deployment conditions. A technique that can quantify ARC degradation nondestructively on commercial modules would be useful both for in-field diagnostics and accelerated aging tests. In this article, we demonstrate that accurate measurements of ARC spectral reflectance can be performed using a modified commercially available integrating-sphere probe. The measurement is fast, accurate, nondestructive, and can be performed outdoors in full-sun conditions. We develop an interferometric model that estimates coating porosity, thickness, and fractional area coverage from the measured reflectance spectrum for a uniform single-layer coating. We demonstrate the measurement outdoors on an active PV installation, identify the presence of an ARC, and estimate the properties of the coating.

14 SOLAR ENERGY↗

Capsule defects measurement [Slides]

Recent high yield shots a NIF showed that capsule defects are limiting shot performance. Voids in the capsule are not well understood in how they degrade yield performance. Recent simulations show that voids can reduce compressibility without any diagnostic signatures but reduced yield. In extreme cases loss of compression is expected. Up to 10,000 voids might be necessary to measure the different effects. Experiments using capsules with engineered defects can help guide simulations and improve our understanding of the physics involved. The knowledge gained can be applied to other problems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Yield degradation due to laser drive asymmetry in D3He backlit proton radiography experiments at OMEGA

Mono-energetic proton radiography is a vital diagnostic for numerous high-energy-density-physics, inertial-confinement-fusion, and laboratory-astrophysics experiments at OMEGA. With a large number of campaigns executing hundreds of shots, general trends in D3He backlighter performance are statistically observed. Each experimental configuration uses a different number of beams and drive symmetry, causing the backlighter to perform differently. Here, we analyze the impact of these variables on the overall performance of the D3He backlighter for proton-radiography studies. This study finds that increasing laser drive asymmetry can degrade the performance of the D3He backlighter. The results of this study can be used to help experimental designs that use proton radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the 70 Ge( d , n ) 71 As cross section from 2.1 MeV to 10 MeV

This work reports experimental 70 Ge(d,n) 71 As cross sections producing Arsenic-71 (t 1/2 = 65.3 h, 28% β + ), a potentially useful diagnostic radionuclide. Target stacks containing two nat Ge foils, a nat Ni monitor foil, and an Al degrader were irradiated with 5.5–10 MeV deuterons using an FN Tandem Van de Graaff accelerator. 71 As and 61 Cu, 56 Co, and 58 Co (from nat Ni(d,x)) were quantified in the foils by high purity germanium gamma spectrometry. Furthermore, the measured cross sections are larger than previously reported and suitable for producing preclinical quantities of diagnostic radiopharmaceuticals.

07 ISOTOPE AND RADIATION SOURCES↗

Optimising the processing and storage of visibilities using lossy compression

The next-generation radio astronomy instruments are providing a massive increase in sensitivity and coverage, largely through increasing the number of stations in the array and the frequency span sampled. The two primary problems encountered when processing the resultant avalanche of data are the need for abundant storage and the constraints imposed by I/O, as I/O bandwidths drop significantly on cold storage. An example of this is the data deluge expected from the SKA Telescopes of more than 60 PB per day, all to be stored on the buffer filesystem. While compressing the data is an obvious solution, the impacts on the final data products are hard to predict. In this paper, we chose an error-controlled compressor – MGARD – and applied it to simulated SKA-Mid and real pathfinder visibility data, in noise-free and noise-dominated regimes. As the data have an implicit error level in the system temperature, using an error bound in compression provides a natural metric for compression. MGARD ensures the compression incurred errors adhere to the user-prescribed tolerance. To measure the degradation of images reconstructed using the lossy compressed data, we proposed a list of diagnostic measures, exploring the trade-off between these error bounds and the corresponding compression ratios, as well as the impact on science quality derived from the lossy compressed data products through a series of experiments. We studied the global and local impacts on the output images for continuum and spectral line examples. We found relative error bounds of as much as 10%, which provide compression ratios of about 20, have a limited impact on the continuum imaging as the increased noise is less than the image RMS, whereas a 1% error bound (compression ratio of 8) introduces an increase in noise of about an order of magnitude less than the image RMS. For extremely sensitive observations and for very precious data, we would recommend a 0.1% error bound with compression ratios of about 4. These have noise impacts two orders of magnitude less than the image RMS levels. At these levels, the limits are due to instabilities in the deconvolution methods. We compared the results to the alternative compression tool DYSCO, in both the impacts on the images and in the relative flexibility. MGARD provides better compression for similar error bounds and has a host of potentially powerful additional features.

Techniques: interferometric↗

Electron cyclotron emission detection of neoclassical tearing modes for control for ITER

Successful operation of ITER requires control of magnetic instabilities including neoclassical tearing modes (NTMs) that can degrade confinement and lead to disruption. Low latency detection by electron cyclotron emission (ECE) diagnostics has been demonstrated in a few current experiments. Using a synthetic diagnostic, we demonstrate low latency NTM detection for ITER with plasmas described by ITER IMAS database scenarios and with realistic limitations imposed on the instrumentation by these high temperature scenarios. 2/1 NTMs are detected 430 ms after magnetic island seeding and before island locking. The radiometer configuration was optimized using simulation, and the smallest detectable island size was explored. Island sizes of ∼3 cm are detectable at the 2/1 surface. The simulated signals incorporate recent physics models for island growth and rotation, which show early locking and continued island growth after locking and before disruption. This work determines limits for ITER ECE spatial resolution imposed by relativistic broadening of channels, which informs hardware design. Real-time detection is demonstrated in hardware that is required by ITER, including on an NI PXI-7853R FPGA system. Development of a synthetic diagnostic and details of the hardware will be discussed.

Cyclotron radiation↗

Degradation of Magnetic Materials for High-Temperature Active Magnetic Bearing Applications in CO₂-Based Environments

High-temperature Active Magnetic Bearings (AMBs) are a promising alternative to conventional bearings in hermetically sealed turbomachinery for supercritical CO₂ (sCO₂) systems. They offer reduced CO₂ leakage, lower windage losses, enhanced misalignment tolerance, reduced wear, and built-in diagnostic capabilities. A critical challenge, however, is ensuring long-term material stability in harsh CO₂-rich environments. This study investigated the degradation behavior of permanent and soft magnetic materials (Alnico 9C, Alnico 5-7C, SmCo 18-T550, Hiperco-50, and coated variants) after up to 6,000 hours of exposure in gaseous CO₂, sCO₂, or air at 450 °C and 550 °C. The evaluation included post-exposure mass change measurements, scanning electron microscopy (SEM) analysis, and magnetic property assessments. The results demonstrate oxidation rates, microstructural evolution, and retention of magnetic performance across conditions. The findings offer essential insights into the thermal corrosion behavior of magnetic materials under CO₂ rich environments and serve as a reference for material selection in AMB system designs.

36 MATERIALS SCIENCE↗

Yield degradation due to laser drive asymmetry in D 3 He backlit proton radiography experiments at OMEGA

Mono-energetic proton radiography is a vital diagnostic for numerous high-energy-density-physics, inertial-confinement-fusion, and laboratory-astrophysics experiments at OMEGA. With a large number of campaigns executing hundreds of shots, general trends in D 3 He backlighter performance are statistically observed. Each experimental configuration uses a different number of beams and drive symmetry, causing the backlighter to perform differently. Here, we analyze the impact of these variables on the overall performance of the D 3 He backlighter for proton-radiography studies. This study finds that increasing laser drive asymmetry can degrade the performance of the D 3 He backlighter. The results of this study can be used to help experimental designs that use proton radiography.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Monitoring the long-term performance of organic redox flow battery by a distribution of relaxation time analysis

Organic redox flow batteries hold great promise as an energy storage technology, but their intricate chemistry makes them vulnerable to various degradation mechanisms. Monitoring this degradation is essential for identifying the limiting processes within the cells. Electrochemical impedance spectroscopy (EIS) offers a straightforward, in-situ method for measuring the total resistance of an operating cell. However, to pinpoint the limiting processes during long-term cycling, EIS data must be complemented by other techniques. Distribution of relaxation time (DRT) analysis is particularly effective for differentiating resistance components. Here, in this study, we perform a comprehensive analysis of resistance evolution and the separation of anode and cathode contributions during long-term cycling of a full cell employing 7,8-dihydroxyphenazine-2-sulfonic acid (DHPS) as the anolyte. Separate analyses of the DHPS anolyte and ferri-/ferrocyanide catholyte were conducted using a symmetric cell setup. The relaxation times derived from symmetric cells facilitate the identification of peaks in the DRT profiles from the full cell. Importantly, the DRT profiles indicate a correlation between the evolution of charge transfer resistance and the chemical degradation of DHPS. The methodologies and results outlined in this study offer significant insights for developing diagnostic tools applicable to other types of redox flow batteries.

Distribution of relaxation time↗

A compact, high resolution energy, and emittance diagnostic for electron beams using active plasma lenses

High-resolution (sub-%), single-shot energy distribution, and emittance measurements of GeV-class electron beams generated by laser plasma accelerators (LPAs) have been enabled through the use of an active plasma lens combined with relatively short dipole magnets. This setup, with only 60 cm between the LPA source and the final diagnostic screen, was facilitated through the use of a replenishable ∼20–40 nm thick liquid crystal plasma mirror to separate remnant laser radiation from the electron beam without emittance degradation. As LPAs capable of generating GeV-class electron beams at cm-scale distances become increasingly ubiquitous, there is a need to supplement these compact accelerators with equally compact diagnostics.

Barber, S. K. (ORCID:0000000172518755)↗

Spot size measurement of a deuterium–tritium dense plasma focus using neutron radiography

Neutron radiography is a technique uniquely suited to applications in nuclear diagnostics, non-destructive testing, and subcritical experiments. The spatial resolution of neutron radiographs is degraded by optical blur in the imaging system and the neutron source size, where the ideal source is point-like to optimize the point-spread function. A potential neutron source for radiography is the dense plasma focus (DPF), a coaxial Z-pinch that produces thermonuclear and beam-target neutrons. To assess if the source size is suitable for radiography, a neutron imaging system was used to measure the source size of the 4 MA Sodium DPF at the Nevada National Security Site operating with deuterium–tritium gas-fill. The source size was measured using the edge-spread function of tungsten objects, each having a rolled (convex) edge. The spot size was found to be 7–12 mm full-width at half-max (FWHM) assuming a Gaussian source, though comparison is presented for Lorentzian and Bennett distributions. The average FWHM was found to be 8.6 ± 1.2 mm vertically and 10.8 ± 1.2 mm horizontally with respect to the image plane, averaging over varied edges and alignments. The results were sensitive to source alignment and edge metrology, which introduced notable uncertainties. These results are consistent with separate experimental measurements as well as magnetohydrodynamics simulations of this DPF, which suggest that neutron production can originate from pinches ∼5–7 mm off-axis. These results suggest that the DPF should be used for radiography at low magnification (M < 1) where spot size does not dominate spatial blur.

47 OTHER INSTRUMENTATION↗

First lower hybrid current drive experiments on the WEST tokamak

The first lower hybrid current drive experiments in the full tungsten WEST tokamak are reported. Good wave coupling is found at rather low plasma current (q 95 ~4.3) and medium density (n e ~3×10 19 m -3 ). Reflection coefficient is in agreement with the expectation from the linear theory of coupling. With low reflection coefficients, 5MW was coupled for 2 seconds. High central electron temperature, up to 5keV, is achieved at ne = 3-4×10 19 m -3 . Flat and even hollow profiles of tungsten density are derived from the bolometry diagnostic. The stored thermal energy follows the H96-P scaling law with very slight degradation with density. The current drive efficiency has been assessed in low loop voltage (V L ~0.15V) discharges. Low plasma current operation and rather high effective charge (Z eff ~3) lead to modest current drive efficiency (η = 0.5-0.65 × 10 19 A.W -1 m -2 ). Long pulse operation (~30s) with high LHCD power (P LH =2.7MW) is achieved with stationary parameters, in particular electron and impurity densities, with the upper water-cooled tungsten divertor.

Goniche, M.↗