Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “deformation estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Estimation of Crystal Lattice Deformations with Depth of Proton-Exchanged Optical Waveguides on Lithium Niobate Single Crystal Substrates

A method for determining the crystal phase and estimating the crystal lattice deformations in H{sub x}Li{sub 1-x}NbO{sub 3} proton-exchanged optical waveguides from an analysis of the Raman light scattering spectra measured with high spatial resolution (the so-called method of micro-RS spectroscopy) is suggested.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Shape Servoing of Deformable Objects Using Model Estimation and Barrier Lyapunov Function

An adaptive shape servoing control method is presented in this article to manipulate a deformable object into a desired shape in 3-D. A finite-point-based representation of the deformable object is used and the deformation Jacobian matrix is approximated using Fourier series basis functions. The unknown parameters of the deformation Jacobian are learned by using the velocity applied to a control point on the object and corresponding change of positions of the points describing the entire object. An integral concurrent learning (ICL)-based parameter update law is designed along with a constrained controller to satisfy the state constraints on the motion of the control point using Barrier Lyapunov function analysis. ICL-based parameter update law uses data history of velocity and corresponding positions of the points along with their current values. An efficient algorithm to update the history stack using singular value maximization is proposed based on the structure of the regressor matrix. Simulations using a physical simulator and experiments using a robot platform are performed to validate the performance of the proposed controller on two different deformable objects.

Vrithik Raj Guthikonda↗

Waveguide detuning caused by transverse magnetic fields on a simulated in-line 6 MV linac

Purpose: Due to the close proximity of the linear accelerator (linac) to the magnetic resonance (MR) imager in linac-MR systems, it will be subjected to magnet fringe fields larger than the Earth's magnetic field of 5x10{sup -5} T. Even with passive or active shielding designed to reduce these fields, some magnitude of the magnetic field is still expected to intersect the linac, causing electron deflection and beam loss. This beam loss, resulting from magnetic fields that cannot be eliminated with shielding, can cause a detuning of the waveguide due to excessive heating. The detuning, if significant, could lead to an even further decrease in output above what would be expected strictly from electron deflections caused by an external magnetic field. Thus an investigation of detuning was performed through various simulations. Methods: According to the Lorentz force, the electrons will be deflected away from their straight course to the target, depositing energy as they impact the linac copper waveguide. The deposited energy would lead to a heating and deformation of the copper structure resulting in resonant frequency changes. PARMELA was used to determine the mean energy and fraction of total beam lost in each linac cavity. The energy deposited into the copper waveguide from the beam losses caused by transverse magnetic fields was calculated using the Monte Carlo program DOSRZnrc. From the total energy deposited, the rise in temperature and ultimately the deformation of the structure was estimated. The deformed structure was modeled using the finite element method program COMSOL MULTIPHYSICS to determine the change in cavity resonant frequency. Results: The largest changes in resonant frequency were found in the first two accelerating cavities for each field strength investigated. This was caused by a high electron fluence impacting the waveguide inner structures coupled with their low kinetic energies. At each field strength investigated, the total change in accelerator frequency was less than a manufacturing tolerance of 10 kHz and is thus not expected to have a noticeable effect on accelerator performance. Conclusions: The amount of beam loss caused by magnetic fringe fields for a linac in a linac-MR system depends on the effectiveness of its magnetic shielding. Despite the best efforts to shield the linac from the magnetic fringe fields, some persistent magnetic field is expected which would result in electron beam loss. This investigation showed that the detuning of the waveguide caused by additional electron beam loss in persistent magnetic fields is not a concern.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonlinear modeling, identification and estimation of slew induced structural deformation

This proposal discusses a new nonlinear, nonparametric method for off-line modeling and on-line estimation of the deformation of a flexible structure undergoing rapid retargeting maneuvers. In these circumstances, the structural stiffness and damping coefficients depend on the angular acceleration omega(dot), the angular rate omega, and the square of the angular rate omega. In the single axis case, the excitation of the structure is represented by the vector u(exp T) = (omega(dot), omega(exp 2), 2(omega)), to which the structural dynamics responds as a 'bilinear' (i.e., parametrically excited) system. A similar technique for multiaxial rotations yields a bilinear model with respect to matrix valued excitations. Three methods of estimation and modeling are described in this proposal to achieve deformation state determination: (1) a method based on a feedback linearized procedure which gives an estimate of the state by means of observers installed in the deformable body; (2) off-line modeling of the deformation state of the structure by means of topological interpolators; and (3) an on-line structural state estimation method based on a combination of the two previous techniques.

Dwyer, Thomas A., III↗

An algorithmic approach to crustal deformation analysis

In recent years the analysis of crustal deformation measurements has become important as a result of current improvements in geodetic methods and an increasing amount of theoretical and observational data provided by several earth sciences. A first-generation data analysis algorithm which combines a priori information with current geodetic measurements was proposed. Relevant methods which can be used in the algorithm were discussed. Prior information is the unifying feature of this algorithm. Some of the problems which may arise through the use of a priori information in the analysis were indicated and preventive measures were demonstrated. The first step in the algorithm is the optimal design of deformation networks. The second step in the algorithm identifies the descriptive model of the deformation field. The final step in the algorithm is the improved estimation of deformation parameters. Although deformation parameters are estimated in the process of model discrimination, they can further be improved by the use of a priori information about them. According to the proposed algorithm this information must first be tested against the estimates calculated using the sample data only. Null-hypothesis testing procedures were developed for this purpose. Six different estimators which employ a priori information were examined. Emphasis was put on the case when the prior information is wrong and analytical expressions for possible improvements under incompatible prior information were derived.

Iz, Huseyin Baki↗

SU-G-JeP3-04: Estimating 4D CBCT from Prior Information and Extremely Limited Angle Projections Using Structural PCA and Weighted Free-Form Deformation

Purpose: To investigate the feasibility of using structure-based principal component analysis (PCA) motion-modeling and weighted free-form deformation to estimate on-board 4D-CBCT using prior information and extremely limited angle projections for potential 4D target verification of lung radiotherapy. Methods: A technique for lung 4D-CBCT reconstruction has been previously developed using a deformation field map (DFM)-based strategy. In the previous method, each phase of the 4D-CBCT was generated by deforming a prior CT volume. The DFM was solved by a motion-model extracted by global PCA and a free-form deformation (GMM-FD) technique, using data fidelity constraint and the deformation energy minimization. In this study, a new structural-PCA method was developed to build a structural motion-model (SMM) by accounting for potential relative motion pattern changes between different anatomical structures from simulation to treatment. The motion model extracted from planning 4DCT was divided into two structures: tumor and body excluding tumor, and the parameters of both structures were optimized together. Weighted free-form deformation (WFD) was employed afterwards to introduce flexibility in adjusting the weightings of different structures in the data fidelity constraint based on clinical interests. XCAT (computerized patient model) simulation with a 30 mm diameter lesion was simulated with various anatomical and respirational changes from planning 4D-CT to onboard volume. The estimation accuracy was evaluated by the Volume-Percent-Difference (VPD)/Center-of-Mass-Shift (COMS) between lesions in the estimated and “ground-truth” on board 4D-CBCT. Results: Among 6 different XCAT scenarios corresponding to respirational and anatomical changes from planning CT to on-board using single 30° on-board projections, the VPD/COMS for SMM-WFD was reduced to 10.64±3.04%/1.20±0.45mm from 21.72±9.24%/1.80±0.53mm for GMM-FD. Using 15° orthogonal projections, the VPD/COMS was further reduced to 1.91±0.86%/0.31±0.42mm based on SMM-WFD. Conclusion: Compared to GMM-FD technique, the SMM-WFD technique can substantially improve the 4D-CBCT estimation accuracy using extremely small scan angles to provide ultra-fast 4D verification. This work was supported by the National Institutes of Health under Grant No. R01-CA184173 and a research grant from Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

A method to estimate the effect of deformable image registration uncertainties on daily dose mapping

Purpose: To develop a statistical sampling procedure for spatially-correlated uncertainties in deformable image registration and then use it to demonstrate their effect on daily dose mapping. Methods: Sequential daily CT studies are acquired to map anatomical variations prior to fractionated external beam radiotherapy. The CTs are deformably registered to the planning CT to obtain displacement vector fields (DVFs). The DVFs are used to accumulate the dose delivered each day onto the planning CT. Each DVF has spatially-correlated uncertainties associated with it. Principal components analysis (PCA) is applied to measured DVF error maps to produce decorrelated principal component modes of the errors. The modes are sampled independently and reconstructed to produce synthetic registration error maps. The synthetic error maps are convolved with dose mapped via deformable registration to model the resulting uncertainty in the dose mapping. The results are compared to the dose mapping uncertainty that would result from uncorrelated DVF errors that vary randomly from voxel to voxel. Results: The error sampling method is shown to produce synthetic DVF error maps that are statistically indistinguishable from the observed error maps. Spatially-correlated DVF uncertainties modeled by our procedure produce patterns of dose mapping error that are different from that due to randomly distributed uncertainties. Conclusions: Deformable image registration uncertainties have complex spatial distributions. The authors have developed and tested a method to decorrelate the spatial uncertainties and make statistical samples of highly correlated error maps. The sample error maps can be used to investigate the effect of DVF uncertainties on daily dose mapping via deformable image registration. An initial demonstration of this methodology shows that dose mapping uncertainties can be sensitive to spatial patterns in the DVF uncertainties.

61 RADIATION PROTECTION AND DOSIMETRY↗

A survey of nuclear quadrupole deformation in order to estimate the nuclear MQM and its relative contribution to the atomic EDM: Searching for the best candidate to focus on an atomic EDM measurement: A nuclear physics perspective

Abstract Measurement of a non-zero permanent electric dipole moment (EDM) in fundamental particles, such as in an electron or a neutron, or in nuclei or atoms, can help us gain a handle on the sources of Charge-Parity (CP) violation, both in the Standard Model (SM) and beyond. The nuclear magnetic quadrupole moment (MQM), the central topic of this work, is also CP, P, and T violating. Nucleons and nuclei have a non-zero MQM from sources within the SM, but the nuclear MQM is dramatically enhanced if the nuclei are structurally quadrupole deformed. Multiple sources contribute to an atomic EDM namely: (i) nuclear EDM through its Schiff moment, which is enhanced by nuclear octupole deformation, (ii) CP violating interactions between the electrons and the nuclei, and (iii) the nuclear MQM that contributes to the atomic EDM in atoms with an unpaired valence electron. Our survey of nuclear quadrupole deformation identified 48 isotopes as ideal systems in which to search for a CP violating EDM via their enhanced nuclear MQM. Of these candidates, $$^{223,225}$$ 223 , 225 Fr, $$^{223}$$ 223 Ra, $$^{223,225,227}$$ 223 , 225 , 227 Ac, $$^{229}$$ 229 Th, and $$^{229}$$ 229 Pa also have maximally enhanced nuclear Schiff moment contribution due to their octupole deformation. Laser cooling of the isotopes of Fr and Ra, among a few others, has already been demonstrated, making $$^{223,225}$$ 223 , 225 Fr and $$^{223}$$ 223 Ra some of the best systems in which to measure an EDM.

MohanMurthy, Prajwal↗

Effect of Accumulative Roll Bonding on Plastic Flow Properties of Commercially Pure Zirconium

Accumulative roll bonding (ARB) has been considered as one of the promising techniques for fabrication of ultra-fine grained (UFG) metallic materials. The ARB process consists of several cycles of cutting, stacking, and rolling of metal sheets, so very high strains can be induced in the material resulting in significant grain refinement and in the formation of UFG microstructures. The ARB technique has been applied to a wide range of metallic materials such as Al and Al alloys, Mg, Fe and steels, Zr, Cu, as well as composite materials. UFG metallic materials processed via ARB show increased strength. Despite a significant body of experimental research into the deformation behaviour of the ARB-processed materials, the fundamentals of their plastic deformation are not fully understood yet. This work focuses on the effect of grain refinement via ARB-processing on the mechanical behavior and on the strain-rate sensitivity of commercially pure Zr (99.8% purity). The mechanical properties of the as-received coarse-grained (CG) and UFG (as-ARB processed) samples were studied at room temperature at two different strain rates. Mechanical strain rate jump tests were performed during tensile deformation to estimate the instantaneous strain-rate sensitivity. The evolution of surface relief during plastic deformation of pure Zr in both CG and UFG conditions was studied. The features of plastic deformation of pure Zr in both CG and UFG conditions are discussed.

36 MATERIALS SCIENCE↗

The generation and accumulation of interstitial atoms and vacancies in alloys with L1{sub 2} superstructure

The dependences of the point defect concentration (interstitial atoms and vacancies) on the deformation degree were calculated for the L1{sub 2} alloys with the high and low antiphase boundaries (APB) energy in terms of the mathematical model of the work and thermal strengthening of the alloys with the L1{sub 2} structure; the concentration of the point defects generated and annihilated in the process of deformation was estimated. It was found that the main part of the point defects generating during plastic deformation annihilates, the residual density of the deformation point defects does not exceed 10{sup −5}.

36 MATERIALS SCIENCE↗

TU-H-CAMPUS-JeP1-05: Dose Deformation Error Associated with Deformable Image Registration Pathways

Purpose: To evaluate errors associated with using different deformable image registration (DIR) pathways to deform dose from planning CT (pCT) to cone-beam CT (CBCT). Methods: Deforming dose is controversial because of the lack of quality assurance tools. We previously proposed a novel metric to evaluate dose deformation error (DDE) by warping dose information using two methods, via dose and contour deformation. First, isodose lines of the pCT were converted into structures and then deformed to the CBCT using an image based deformation map (dose/structure/deform). Alternatively, the dose matrix from the pCT was deformed to CBCT using the same deformation map, and then the same isodose lines of the deformed dose were converted into structures (dose/deform/structure). The doses corresponding to each structure were queried from the deformed dose and full-width-half-maximums were used to evaluate the dose dispersion. The difference between the FWHM of each isodose level structure is defined as the DDE. Three head-and-neck cancer patients were identified. For each patient, two DIRs were performed between the pCT and CBCT, either deforming pCT-to-CBCT or CBCT-to-pCT. We evaluated the errors associated by using either of these pathways to deform dose. A commercially available, Demons based DIR was used for this study, and 10 isodose levels (20% to 105%) were used to evaluate the errors in various dose levels. Results: The prescription dose for all patients was 70 Gy. The mean DDE for CT-to-CBCT deformation was 1.0 Gy (range: 0.3–2.0 Gy) and this was increased to 4.3 Gy (range: 1.5–6.4 Gy) for CBCT-to-CT deformation. The mean increase in DDE between the two deformations was 3.3 Gy (range: 1.0–5.4 Gy). Conclusion: The proposed DDF was used to quantitatively estimate dose deformation errors caused by different pathways to perform DIR. Deforming dose using CBCT-to-CT deformation produced greater error than CT-to-CBCT deformation.

60 APPLIED LIFE SCIENCES↗

Estimating permeability from quasi-static deformation: Temporal variations and arrival time inversion

Transient pressure variations within a reservoir can be treated as a propagating front and analyzed using an asymptotic formulation. From this perspective one can define a pressure 'arrival time' and formulate solutions along trajectories, in the manner of ray theory. We combine this methodology and a technique for mapping overburden deformation into reservoir volume change as a means to estimate reservoir flow properties, such as permeability. Given the entire 'travel time' or phase field, obtained from the deformation data, we can construct the trajectories directly, there-by linearizing the inverse problem. A numerical study indicates that, using this approach, we can infer large-scale variations in flow properties. In an application to Interferometric Synthetic Aperture (InSAR) observations associated with a CO{sub 2} injection at the Krechba field, Algeria, we image pressure propagation to the northwest. An inversion for flow properties indicates a linear trend of high permeability. The high permeability correlates with a northwest trending fault on the flank of the anticline which defines the field.

54 ENVIRONMENTAL SCIENCES↗

Computational material design for Q&P steels with plastic instability theory

In this paper, the deformation limits of Quenching and Partitioning (Q&P) steels are examined with the plastic instability theory. For this purpose, the constituent phase properties of various Q&P steels were first experimentally obtained, and used to estimate the overall tensile stress-strain curves based on the simple rule of mixture (ROM) with the iso-strain and iso-stress assumptions. Plastic instability theory was then applied to the obtained overall stress-strain curves in order to estimate the deformation limits of the Q&P steels. A parametric study was also performed to examine the effects of various material parameters on the deformation limits of Q&P steels. Computational material design was subsequently carried out based on the information obtained from the parametric study. The results show that the plastic instability theory with iso-stress-based stress-strain curve may be used to provide the lower bound estimate of the uniform elongation (UE) for the various Q&P steels considered. The results also indicate that higher austenite stability/volume fractions, less strength difference between the primary phases, higher hardening exponents of the constituent phases are generally beneficial for the performance improvement of Q&P steels, and that various material parameters may be concurrently adjusted in a cohesive way in order to improve the performance of Q&P steel. The information from this study may be used to devise new heat treatment parameters and alloying elements to produce Q&P steels with the improved performance.

Cheng, G.↗

Measurement of Surface Deformation Related to the December 2018 Mt. Etna Eruption Using Time-Series Interferometry and Magma Modeling for Hazard Zone Mapping

Mount Etna has erupted several times since it was first formed. Recently, Mount Etna began erupting again over 24–27 December 2018. Because it erupts frequently, Mount Etna should be observed on a frequent basis. From June 2018 to October 2019, 34 and 56 interferometric synthetic aperture radar (InSAR) images were acquired from the ascending and descending tracks of the Sentinel-1 satellite, respectively. We employed the Stanford Method for Persistent Scatterers (StaMPS) and a refined small baseline subset (SBAS) InSAR method to produce a surface deformation time-series map. In the time-series analysis, the phase signal remained unaltered with time. The Okada model was then applied to the result to generate a modeled interferogram, and the Q-LavHA program was run to generate a lava flow prediction model. A direct comparison of the results showed that Persistent Scatterers Interferometry (PSI)-StaMPS and the refined SBAS technique were comparable in terms of the displacement pattern, with slightly different velocity values obtained for individual points. In particular, a velocity range of −25 to 21 cm/yr was obtained from PSI-StaMPS, whereas a range of −30 to 25 cm/yr was obtained from the refined SBAS method. Upon computation of the vertical and east-west displacement components based on ascending and descending track data using both methods, deformation velocities of 51.5 and 52.5 cm/yr in the westerly direction on the western flank of Mount Etna were obtained from PSI-StaMPS and the refined SBAS method, respectively, whereas on the eastern flank, deformation toward the east was estimated to occur at a velocity of 50.1 or 54.2 cm/yr, respectively. PSIStaMPS estimated a vertical deformation velocity of −5.3 to 18.3 cm/yr, whereas the refined SBAS method produced a velocity range of approximately −7 to 19 cm/yr. The interferogram obtained via Okada modeling showed two fault sources in the 2018 Mount Etna eruption and a total volume change of approximately 12.39 × 10 6 m 3 . From the modeling results, a lava flow prediction model was generated using the Q-LavHA program. The approaches described in this study can be used by government officials, authorities, and other decision-makers to monitor and assess the risk of volcanic activity in the region.

Suci Ramayanti↗

Kalman-like estimation for static distributed systems Antenna shape from radiation measurements

This paper advances an approach to the determination of shape of static distributed systems. It also illustrates the application of the approach to the problems of surface diagnosis of large parabolic reflectors. The estimation methods developed combine in an optimal sense the information from an elliptic model of the structure and from measurements of the structural deflection and of the far-field pattern changes due to the structural deformation. The estimators have a predictor-corrector structure, quite similar to that of a Kalman filter. The system model is first used to obtain a predicted estimate. A correction term is then added to the prediction to obtain the final state estimate. The relative weighting between prediction and correction terms is determined by an estimator gain. As in a Kalman filter, the estimator gain can be expressed in terms of the state estimation error covariance.

Rodriguez, G.↗

Development of deformable moving lung phantom to simulate respiratory motion in radiotherapy

Radiation treatment requires high accuracy to protect healthy organs and destroy the tumor. However, tumors located near the diaphragm constantly move during treatment. Respiration-gated radiotherapy has significant potential for the improvement of the irradiation of tumor sites affected by respiratory motion, such as lung and liver tumors. To measure and minimize the effects of respiratory motion, a realistic deformable phantom is required for use as a gold standard. The purpose of this study was to develop and study the characteristics of a deformable moving lung (DML) phantom, such as simulation, tissue equivalence, and rate of deformation. The rate of change of the lung volume, target deformation, and respiratory signals were measured in this study; they were accurately measured using a realistic deformable phantom. The measured volume difference was 31%, which closely corresponds to the average difference in human respiration, and the target movement was − 30 to + 32 mm. The measured signals accurately described human respiratory signals. This DML phantom would be useful for the estimation of deformable image registration and in respiration-gated radiotherapy. This study shows that the developed DML phantom can exactly simulate the patient's respiratory signal and it acts as a deformable 4-dimensional simulation of a patient's lung with sufficient volume change.

61 RADIATION PROTECTION AND DOSIMETRY↗

Organ Deformation and Dose Coverage in Robotic Respiratory-Tracking Radiotherapy

Purpose: Respiratory motion presents a significant challenge in stereotactic body radiosurgery. Respiratory tracking that follows the translational movement of the internal fiducials minimizes the uncertainties in dose delivery. However, the effect of deformation, defined as any changes in the body and organs relative to the center of fiducials, remains unanswered. This study investigated this problem and a possible solution. Methods and Materials: Dose delivery using a robotic respiratory-tracking system was studied with clinical data. Each treatment plan was designed with the computed tomography scan in the end-expiration phase. The planned beams were applied to the computed tomography scan in end-inspiration following the shift of the fiducials. The dose coverage was compared with the initial plan, and the uncertainty due to the deformation was estimated. A necessary margin from the clinical target volume to the planning target volume was determined to account for this and other sources of uncertainty. Results: We studied 12 lung and 5 upper abdomen lesions. Our results demonstrated that for lung patients with properly implanted fiducials a 3-mm margin is required to compensate for the deformation and a 5-mm margin is required to compensate for all uncertainties. Our results for the upper abdomen tumors were still preliminary but indicated a similar result, although a larger margin might be required. Conclusion: The effect of body deformation was studied. We found that adequate dose coverage for lung tumors can be ensured with proper fiducial placement and a 5-mm planning target volume margin. This approach is more practical and effective than a recent proposal to combine four-dimensional planning with respiratory tracking.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-CD-206-09: Learning-Based MRI-CT Prostate Registration Using Spare Patch-Deformation Dictionary

Purpose: To enable MRI-guided prostate radiotherapy, MRI-CT deformable registration is required to map the MRI-defined tumor and key organ contours onto the CT images. Due to the intrinsic differences in grey-level intensity characteristics between MRI and CT images, the integration of MRI into CT-based radiotherapy is very challenging. We are developing a learning-based registration approach to address this technical challenge. Methods: We propose to estimate the deformation between MRI and CT images in a patch-wise fashion by using the sparse representation technique. Specifically, we assume that two image patches should follow the same deformation if their patch-wise appearance patterns are similar. We first extract a set of key points in the new CT image. Then, for each key point, we adaptively construct a coupled dictionary from the training MRI-CT images, where each coupled element includes both appearance and deformation of the same image patch. After calculating the sparse coefficients in representing the patch appearance of each key point based on the constructed dictionary, we can predict the deformation for this point by applying the same sparse coefficients to the respective deformations in the dictionary. Results: This registration technique was validated with 10 prostate-cancer patients’ data and its performance was compared with the commonly used free-form-deformation-based registration. Several landmarks in both images were identified to evaluate the accuracy of our approach. Overall, the averaged target registration error of the intensity-based registration and the proposed method was 3.8±0.4 mm and 1.9±0.3 mm, respectively. Conclusion: We have developed a novel prostate MR-CT registration approach based on patch-deformation dictionary, demonstrated its clinical feasibility, and validated its accuracy. This technique will either reduce or compensate for the effect of patient-specific treatment variation measured during the course of radiotherapy, is therefore well-suited for a number of MRI-guided adaptive radiotherapy, and potentially enhance prostate radiotherapy treatment outcome.

60 APPLIED LIFE SCIENCES↗