Engineering PapersSearch

SEARCH · Engineering Papers

Results for “defect motion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The present state and the future direction of eddy viscosity models

Information is given in viewgraph form on the present state and future direction of eddy viscosity models. Topics covered include the eddy viscosity dilemma, two-equation models, equations of motion, free shear flows, incompressible free shear flows, model-predicted boundary layer structure, defect layer analysis, the effects of pressure gradients, viscous sublayer structure, wall functions and viscous damping, viscous damping for kappa-omega, the effects of compressibility, perturbation analysis of the wall layer, an alternative compressibility term, unsteady boundary layers, incompressible separation, backstep results, and compressible separation.

Wilcox, David C.

Handheld White Light Interferometer for Measuring Defect Depth in Windows

Accurate quantification of defects (scratches and impacts) is vital to the certification of flight hardware and other critical components. The amount of damage to a particular component contributes to the performance, reliability, and safety of a system, which ultimately affects the success or failure of a mission or test. The launch-commit criteria on a Space Shuttle Orbiter window are governed by the depth of the defects that are identified by a visual inspection. This measurement of a defect is not easy to obtain given the environment, size of the defect, and location of the window(s). The determination of depth has typically been performed by taking a mold impression and measuring the impression with an optical profiling instrument. Another method of obtaining an estimate of the depth is by using a refocus microscope. To use a refocus microscope, the surface of the glass and bottom of the defect are, in turn, brought into focus by the operator. The amount of movement between the two points corresponds to the depth of the defect. The refocus microscope requires a skilled operator and has been proven to be unreliable when used on Orbiter windows. White light interferometry was chosen as a candidate to replace the refocus microscope. The White Light Interferometer (WLI) was developed to replace the refocus microscope as the instrument used for measuring the depth of defects in Orbiter windows. The WLI consists of a broadband illumination source, interferometer, detector, motion control, displacement sensor, mechanical housing, and support electronics. The illumination source for the WLI is typically a visible light emitting diode (LED) or a near-infrared superluminescent diode (SLD) with power levels of less than a milliwatt. The interferometer is a Michelson configuration consisting of a 1-in. (2.5-cm) cube beam splitter, a 0.5-in. (1.3-cm) optical window as a movable leg (used to closely match the return intensity of the fixed leg from the window), and a mirrored prism to fold the optics into the mechanical housing. The detector may be one of many C-mount CCD (charge-coupled device) cameras. Motion is provided by a commercial nanostepping motor with a serial interface. The displacement sensor is a custom device specifically designed for this application. The mechanical housing and support electronics were designed to integrate the various components into an instrument that could be physically handled by a technician and easily transported.

Youngquist, Robert

Vortex motion induced losses in tantalum resonators

Tantalum (Ta)-based superconducting circuits have been demonstrated to enable ultrahigh qubit quality factors (𝑄), motivating a careful study of the microscopic origin of the remaining losses that limit their performance. We have recently shown that the losses in Ta-based resonators are dominated by two-level systems at low microwave powers and millikelvin temperatures. We also observe that some devices exhibit loss that is exponentially activated at a lower temperature inconsistent with the superconducting critical temperature (T 𝑐 ) of the constituent film. Specifically, dc resistivity measurements show a T 𝑐 of over 4 K, while microwave measurements of resonators fabricated from these films show losses that increase exponentially with temperature with an activation energy as low as 0.3 K. Here, in this study, we present a comparative study of the structural and thermodynamic properties of Ta-based resonators and identify vortex motion-induced loss as the source of thermally activated microwave loss. Through careful magnetoresistance and x-ray diffraction measurements, we observe that the increased loss occurs for films that are in the clean limit, where the superconducting coherence length (𝜉) is shorter than the mean free path (𝑙). Vortex motion-induced losses are suppressed for films in the dirty limit, which show evidence of structural defects that can pin vortices. We verify this hypothesis by explicitly pinning vortices via patterning, and we find that we can suppress the loss by microfabrication.

36 MATERIALS SCIENCE

Direct Visualization of Defect‐Controlled Diffusion in van der Waals Gaps

Abstract Diffusion processes govern fundamental phenomena such as phase transformations, doping, and intercalation in van der Waals (vdW) bonded materials. Here, the diffusion dynamics of W atoms by visualizing the motion of individual atoms at three different vdW interfaces: hexagonal boron nitride (BN)/vacuum, BN/BN, and BN/WSe 2 , by recording scanning transmission electron microscopy movies is quantified. Supported by density functional theory (DFT) calculations, it is inferred that in all cases diffusion is governed by intermittent trapping at electron beam‐generated defect sites. This leads to diffusion properties that depend strongly on the number of defects. These results suggest that diffusion and intercalation processes in vdW materials are highly tunable and sensitive to crystal quality. The demonstration of imaging, with high spatial and temporal resolution, of layers and individual atoms inside vdW heterostructures offers possibilities for direct visualization of diffusion and atomic interactions, as well as for experiments exploring atomic structures, their in situ modification, and electrical property measurements of active devices combined with atomic resolution imaging.

Chemistry

Low-temperature thermostatics of face-centered-cubic metallic hydrogen

The thermostatic properties of a high-symmetry phase of metallic hydrogen with atomic sphere radius between 0.1 and 1.5 bohr are studied, with special emphasis accorded to electronic screening and quantum proton motion. The electron-proton and proton-proton interactions receive a perturbation treatment based on the Singwi dielectric function, while the proton motion is handled by self-consistent harmonic approximation. Quantum behavior is found to be less pronounced than expected, and nuclear magnetism is absent. The phonon spectrum is, however, affected by screening and large proton motion. The zero-point vibrational energy and the superconducting critical temperature are below previous estimates. The crystalline-defect formation energies are a few times the Debye energy, which implies that defects contribute significantly to melting at the lower particle densities.

Caron, L. G.

Atomic-Scale Imaging of Lithium Vacancies in a Battery Cathode by Multislice Electron Ptychography

Atomic-resolution imaging of battery materials is critical for identification of local defects and structural variations, which are tied to battery performance. However, since battery materials are, by design, optimized to allow ion motion in response to an applied electric field, they are also very sensitive to radiation damage by an electron beam. Image resolution is therefore severely constrained by the dose applied. Here, we show that multislice electron ptychography (MEP) can provide sub-ångström lateral resolution images of both light and heavy elements of a Li-ion battery cathode, along with nanometer-scale depth information and greater dose efficiency than conventional electron microscopy methods. Using the depth-sectioning capability of MEP, we have been able to obtain direct visualizations of Li vacancy clusters, atom column by atom column, in Li x Ni 0.33 Mn 0.33 Co 0.33 O 2 (NMC111) cathodes. This capability to track Li distributions will be valuable in understanding, informing, and optimizing electrode material design for ion storage and transfer.

batteries

On the Motions of an Oscillating System Under the Influence of Flip-Flop Controls

So-called flip-flop controls (also called "on-off-course controls") are frequently preferred to continuous controls because of their simple construction. Thus they are used also for the steering control of airplanes. Such a body possesses-even if one thinks, for instance, only of the symmetric longitudinal motion - three degrees of freedom so that a study of its motions under the influence of an intermittent control is at least lengthy. Thus, it is suggested that an investigation of the basic effect of such a control first be made on a system with one degree of freedom. Furthermore, we limit ourselves in the resent report to the investigation of an "ideal" control where the control surface immediately obeys the command given by the "steering control function". Thus the oscillation properties of the control surface and the defects in linkage, sensing element, and mixing device are, at first, neglected. As long as the deviations from the "ideal" control may be neglected in practice, also the motion of the control surface takes place at the heat of the motion of the principal system. The aim of our investigation is to obtain a survey of the influence of the system and control coefficients on the damping behavior which is to be attained.

Fluegge-Lotz, I.

3D Guided Wave Motion Analysis on Laminated Composites

Ultrasonic guided waves have proved useful for structural health monitoring (SHM) and nondestructive evaluation (NDE) due to their ability to propagate long distances with less energy loss compared to bulk waves and due to their sensitivity to small defects in the structure. Analysis of actively transmitted ultrasonic signals has long been used to detect and assess damage. However, there remain many challenging tasks for guided wave based SHM due to the complexity involved with propagating guided waves, especially in the case of composite materials. The multimodal nature of the ultrasonic guided waves complicates the related damage analysis. This paper presents results from parallel 3D elastodynamic finite integration technique (EFIT) simulations used to acquire 3D wave motion in the subject laminated carbon fiber reinforced polymer composites. The acquired 3D wave motion is then analyzed by frequency-wavenumber analysis to study the wave propagation and interaction in the composite laminate. The frequency-wavenumber analysis enables the study of individual modes and visualization of mode conversion. Delamination damage has been incorporated into the EFIT model to generate "damaged" data. The potential for damage detection in laminated composites is discussed in the end.

Tian, Zhenhua

Imaging Bias‐Driven Domain Wall Motion With Scanning Oscillator Piezoresponse Force Microscopy

Understanding ferroelectric domain wall dynamics at the nanoscale across a broad range of timescales requires measuring domain wall position under different applied electric fields. The success of piezoresponse force microscopy (PFM) as a tool to apply local electric fields at different positions and imaging their changing position, together with the information obtained from associated switching spectroscopies has fueled numerous studies of the dynamics of ferroelectric domains to determine the impact of intrinsic parameters such as crystalline order, defects and pinning centers, as well as boundary conditions such as environment. However, the investigation of sub-coercive reversible domain wall vibrational modes requires the development of new tools that enable visualizing domain wall motion under varying applied fields with high temporal and spatial resolution while also accounting for spurious electrostatic effects. Here, scanning oscillator piezoresponse force microscopy extends the investigation of domain wall dynamics to new regimes, providing direct visualization of domain wall position as a function of an external electric field that varies in time and location. In conclusion, this enables studying the energetics of field-driven ferroelectric domain wall motion, which is shown to obey a thermally activated flow regime in the millisecond timescale.

Piezoresponse Force Microscopy

Defects in nickel-base superalloys

The presence of substantial amounts of the sigma phase in Ni-base superalloys can drastically reduce the alloy's stress rupture life. No predictive system exists which is entirely successful in anticipating the formation of sigma, mu, and similar phases in new and substantially different alloys. Freckles are defects due to the segregation of elements in quantities that can lead to phase precipitation, and are caused by gravity-driven fluid motion that yields microsegregation in the ingots typically used in the fabrication of structures based on these alloys. Also noted are the effects of porosity and grain boundaries on superalloy mechanical properties.

Dreshfield, Robert L.

Molecular Dynamics of a Water-Lipid Bilayer Interface

We present results of molecular dynamics simulations of a glycerol 1-monooleate bilayer in water. The total length of analyzed trajectories is 5ns. The calculated width of the bilayer agrees well with the experimentally measured value. The interior of the membrane is in a highly disordered fluid state. Atomic density profile, orientational and conformational distribution functions, and order parameters indicate that disorder increases toward the center of the bilayer. Analysis of out-of-plane thermal fluctuations of the bilayer surfaces occurring at the time scale of the present calculations reveals that the distribution of modes agrees with predictions of the capillary wave model. Fluctuations of both bilayer surfaces are uncorrelated, yielding Gaussian distribution of instantaneous widths of the membrane. Fluctuations of the width produce transient thinning defects in the bilayer which occasionally span almost half of the membrane. The leading mechanism of these fluctuations is the orientational and conformational motion of head groups rather than vertical motion of the whole molecules. Water considerably penetrates the head group region of the bilayer but not its hydrocarbon core. The total net excess dipole moment of the interfacial water points toward the aqueous phase, but the water polarization profile is non-monotonic. Both water and head groups significantly contribute to the surface potential across the interface. The calculated sign of the surface potential is in agreement with that from experimental measurements, but the value is markedly overestimated. The structural and electrical properties of the water-bilayer system are discussed in relation to membrane functions, in particular transport of ions and nonelectrolytes across membranes.

Wilson, Michael A.

Development of Optical Diagnostic Techniques for Microgravity Materials Processing

Materials processing including crystal growth, either under a gravity environment on ground or a microgravity environment in space, involves complicated phenomena of fluid motions in gas or liquid phases as well as interaction of various species. To obtain important physical insight, it is very necessary to provide gross-field optical diagnostics for monitoring various physical properties. Materials processing inhibits easy access by ordinary instruments and thus characterizing gross-field physical properties is very challenging. Typical properties of importance can be fluid velocity, temperature, and species concentration for fluids, and surface topology and defects for solids. Observing surface grow rate during crystal growth is also important. Material microstructures, i.e., integrity of crystal structures, is strongly influenced by the existence of thermally-induced flow as well as local nucleation of particles during solidification, which may act in many detrimental ways. In both ground-based and microgravity experiments, the nature of product property changes resulting from three-dimensional fluid or particle motions need be characterized. Gross-field diagnostics is thus required to identify their effects on product defects and process deficiencies. The quantitative visualization techniques can also be used for validation of numerical modeling. For optical nonintrusive gross-field diagnostic techniques, two approaches were developed as summer projects. One optical approach allows us to provide information of species concentration and temperature for monitoring in real time. The other approach, that is, the concept which is formulated for detection of surface topography measurement can provide unprecedented spatial resolution during crystal growth.

Cha, Soyoung Stephen

Studies of convection in a solidifying binary mixture at reduced gravity

A great deal of interest was generated recently in the possibility of producing new materials in the reduced gravity environment provided during the forthcoming missions of Spacelab. The range of possibilities extend from producing large crystals of uniform properties to manufacturing materials with unique properties. Most of these processes involve the solidification of materials from the liquid state. Convective motions within the liquid during solidification can influence the local material composite and the shape of the solid-liquid interface which may result in solids with non-uniform properties and crystal defects. The microgravity environment of Spacelab is being viewed as one in which the buoyancy forces are eliminated so that convection driven by thermal gradients does occur, resulting in an improved solidification process. However, convection may occur for other reasons and whether convection is negligible or not during solidification constitutes processing in low-gravity environment. Little information exists presently on convection during solidification under such circumstances. A continuation of an analytical investigation into the nature of convective motion in a binary liquid layer due to surface tension forces during its solidification is reported. The onset of convection will be determined through a stability analysis which is described.

Antar, B. N.

Quantification Of 4H- To 3C-Polymorphism In Silicon Carbide (SiC) Epilayers And An Investigation Of Recombination-Enhanced Dislocation Motion In SiC By Optical Emission Microscopy (Oem) Techniques

Environments that impose operational constraints on conventional silicon-(Si) based semiconductor devices frequently appear in military- and space-grade applications. These constraints include high temperature, high power, and high radiation environments. Silicon carbide (SiC), an alternative type of semiconductor material, has received abundant research attention in the past few years, owing to its radiation-hardened properties as well as its capability to withstand high temperatures and power levels. However, the growth and manufacture of SiC devices is still comparatively immature, and there are severe limitations in present crystal growth and device fabrication processes. Among these limitations is a variety of crystal imperfections known as defects. These imperfections can be point defects (e.g., vacancies and interstitials), line defects (e.g., edge and screw dislocations), or planar defects (e.g., stacking faults and double-positioning boundaries). All of these defects have been experimentally shown to be detrimental to the performance of electron devices made from SiC. As such, it is imperative that these defects are significantly reduced in order for SiC devices to become a viable entity in the electronics world. The NASA Glenn High Temperature Integrated Electronics & Sensors Team (HTIES) is working to identify and eliminate these defects in SiC by implementing improved epitaxial crystal growth procedures. HTIES takes two-inch SiC wafers and etches patterns, producing thousands of mesas into each wafer. Crystal growth is then carried out on top of these mesas in an effort to produce films of improved quality-resulting in electron devices that demonstrate superior performance-as well as fabrication processes that are cost-effective, reliable, and reproducible. In this work, further steps are taken to automate HTIES' SiC wafer inspection system. National Instruments LabVIEW image processing and pattern recognition routines are developed that are capable of quantifying and mapping defects on both the substrate and mesa surfaces, and of quantifying polymorphic changes in the grown materials. In addition, an optical emission microscopy (OEM) system is developed that will facilitate comprehensive study of recombination-enhanced dislocation motion (REDM).

Speer, Kevin M.