Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dc”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Progress toward absolute calibrations of DC x-ray sources from 1 keV to >30 keV for Z diagnostics applications

Numerous x-ray diagnostics at the Z facility, time-resolved and time-integrated, would benefit from a local calibrated x-ray source. For many years, Z has used low-power Manson x-ray sources to provide some characterization information for components of Z diagnostics below 30 keV. More recently, we have acquired TruFocus x-ray sources, which operate at voltages up to 100 kV depending on the anode material and model. These DC sources have demonstrated good stability and repeatability. Absolute calibrations of either sources or detectors usually involve another calibrated detector from another source, which has not been readily available locally. Therefore, we have adopted the strategy of characterizing a sensitive semiconductor diode detector by controlling or inferring the active volume. This characterized detector is then used to scale the Manson x-ray spectral shape as measured by an Amptek energy-resolving detector. Here, the result agrees well with the modeled source spectrum. We can apply this technique to the TruFocus as well.

Crystal spectroscopy↗

SCR-based Medium Voltage DC Solid-State Circuit Breaker

This paper describes a medium voltage solid-state circuit breaker (SSCB) based on SCR technology, featuring short fault-interruption time and a minimal turn-off auxiliary circuit. The SSCB design incorporates a specialized SCR and a commutation circuit designed with an objective to reduce the required SCR hold-off/turn-off time, tq, which primarily determines the fault interruption duration. To validate the design, simulation analysis is presented, and a 1.5 kV 300 A SSCB prototype has been built and tested. The results confirm the effectiveness of the proposed design philosophy demonstrating the SSCB's ability to interrupt a 200 A load current in less than 50 μs. The proposed SCR-based SSCB has been developed for DC applications but is equally applicable to AC applications.

Kandula, Prasad [ORNL] (ORCID:0000000174017284)↗

Predictive Control to Further Reduce DC-Link Capacitor Current Stress for Segmented Inverter

Two three-phase interleaved inverters have been used in traction drive applications to reduce the current stress in a DC link capacitor bank. In such applications, either carrier-based or space vector modulation is used to select the optimum switching sequences, and the results show 50% less capacitor current than that of a single three-phase inverter. The switching state selection process for this inverter is tedious, and there has been no research to find the optimal switching state. To overcome this challenge, this research employed a simple finite set model predictive control to select the optimum switching sequence for a dual three-phase interleaved topology, called a segmented inverter. The results show that the predictive control algorithm can provide a simple solution and can reduce the current stress by 27% compared with traditional modulation techniques for the segmented inverters.

Ribeiro, Pedro↗

Oxygen vacancy migration and impact on high voltage DC polarization in 0.8BaTiO 3 –0.2BiZn 0.5 Ti 0.5 O 3

Electrical polarization and defect transport are examined in 0.8BaTiO 3 –0.2BiZn 0.5 Ti 0.5 O 3 , an attractive capacitor material for high power electronics. Oxygen vacancies are suggested to be the majority charge carrier at or below 250°C with a grain conduction hopping activation energy of 0.97 eV and 0.92 eV for thermally stimulated depolarization current (TSDC) and impedance spectroscopy measurements, respectively. At higher temperature, thermally generated electronic conduction with an activation energy of 1.6 eV is dominant. Significant oxygen vacancy concentration is indicated (up to ~1%) due to cation vacancy formation (i.e., acceptor defects) from observed Bi (and likely Zn) volatility. Oxygen vacancy diffusivity is estimated to be 10 -12.8 cm 2 /s at 250°C. Low diffusivity and high activation energies are indicative of significant defect interactions. Dipolar oxygen vacancy defects are also indicated, with an activation energy of 0.59 eV from TSDC measurements. In conclusion, the large oxygen vacancy content leads to a short lifetime during high voltage (30 kV/cm), high temperature (250°C) direct current (DC) electrical measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ARC-SAFE: Accelerated Response semiconducting Contactors and Surge Attenuation For DC Electrical systems (Final Scientific/Technical Report)

The landscape of power transmission and distribution is quickly evolving as more power conversion is done through power electronics and transmitted or distributed at medium voltage direct current (MVDC). As power electronics tend to store less energy and be less resilient to faults than conventional power transformers, a reliable and fast protection against faults is critical to protect power electronics (PE) based infrastructure, especially for medium- and high-voltage applications. This motivates the development of PE based protection circuits to replace slower contemporary electromechanical breakers. In this project a novel PE based MVDC circuit breaker is developed; the new design is comprised of 1) a normally-on leg made of commercially-available, cascaded SiC junction field effect transistors (JFETs) with a passive balancing network, and 2) a normally-off leg based on an optically-triggered gallium nitride (GaN) photoconductive semiconductor switch (PCSS). The normally-off leg was designed to be quickly turned on, to divert current to an auxiliary dissipative circuit, as the normally-on leg is turned off. This approach, using solid-state devices, was selected for a high-performance, fast-switching operation for the DC circuit breaker as compared to approaches that use slower mechanical switches. To be practical, the circuit breaker must have low conduction loss (low Ron) in the normally-on leg and fast coordinated triggering of the normally-off leg to avoid damage from inductive flyback, which could be considerable for long lengths of cable.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrical and Thermal Load Impacts of Three District Heating and Cooling Designs for an Existing Community in Washington, DC

District energy systems that provide building heating and cooling are a promising option to provide low-cost, energy efficient heating and cooling solutions for communities. As some buildings move to electrified heating designs, there may be significant increases in electric grid demand, particularly in the winter. District energy systems may be able to help reduce these high electrical demands on the electric grid, while also providing decreased overall energy consumption with an increased flexibility in electrical energy usage. To evaluate and compare district options for district-based heating and cooling, an existing neighborhood of Washington, DC consisting of 35 existing buildings was selected as a case study. This study models and compares a fourth generation (4G) district heating and cooling systems that provide hot and chilled water from a central plant directly to each prosumer and a fifth generation (5G) district heating and cooling systems that provide near-ambient water via geothermal boreholes to interface with an energy transfer station with a heat pump at each prosumer. These district systems are compared against a baseline of the non-connected buildings with their self-contained and current HVAC systems. The neighborhood was selected as a good candidate for a district system for its diversity of loads (mix of different commercial and property types) and the availability of building characteristics. URBANopt District Energy Systems (DES) was used to model the buildings and create initial Modelica models for the district systems. Finally, the DES models were tuned and simulated in Dymola, and the outputs were post-processed for verification and to calculate the electrical and thermal grid impact metrics. This is the first documentation of this workflow and its complete analysis. The three designed systems are compared via their grid metrics including: total energy consumption, electrical demand peak loads, daily peak-to-valley ratios, and system ramping. A detailed discussion is provided about how each system impacts and interacts with the electric grid.

15 GEOTHERMAL ENERGY↗

DC Cryogenic Modeling of Open-Source SkyWater 130 nm MOSFETs at 77 K Using BSIM4

Cryogenic applications in high-energy physics (HEP) demand reliable, low-power CMOS electronics capable of operating at liquid nitrogen temperatures (77 K). The open-source SkyWater 130nm (SKY130) CMOS process has previously been shown to operate at temperatures as low as 4 K making it a promising candidate for HEP applications. In this work, we characterize and model SKY130 low-threshold voltage transistors at 77 K, which is a temperature commonly used in modeling applications for liquid argon detectors. DC characteristic measurements were performed at both room temperature and liquid nitrogen temperature. We created a cryogenic modeling approach to produce a SPICE-compatible, isothermal BSIM4-based model for select transistor sizes at 77 K. The resulting model agrees with data at 77 K with an average error on the order of 20% (relative RMS) and shows no dependence on drain voltage. Due to the open-source nature of SKY130, we have made our models publicly available on Github. We hope this work will continue the trend for democratizing circuit design at cryogenic temperatures in high-energy physics by enabling open access to accurate cryogenic CMOS device models at 77 K.

Beall, F. [Texas U., Arlington]↗

DC Microgrid Reliability Enhancement with Adaptive Converter Thermal Management

Due to the different device selections, aging levels, and thermal dissipation performance, some converters may take additional thermal stress on switching devices than others in paralleled converter systems, which will reduce system reliability. To address this problem, this paper proposes a power-sharing strategy with adaptive thermal management. First, the temperature-based power loss model and electrical-thermal model are established. Based on that, a high-accuracy IGBT junction temperature estimate considering the power loss-temperature coupling can be achieved. Further, the thermal-sharing for all the switching devices in paralleled converters can be achieved with the proposed adaptive thermal management strategy. The proposed strategy can change the power-sharing ratio adaptively according to the system operation conditions, which will contribute to the system reliability enhancement. The effectiveness of the proposed strategy is verified through PLECS thermal simulation and joint real-time simulation with Dspace and RT-box.

DC microgrid↗

Passenger Survey - Washington DC Metrorail - 2012

The primary purposes of the survey were to update ridership by the jurisdiction of residence for use in Metrorail’s operating subsidy allocation and to collect demographic, travel, and access data for Title VI compliance, system planning, and operation analyses. It was not a customer opinion survey; the focus was on ridership and travel characteristics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Metrobus Survey - Washington DC - 2014

The primary purposes of the survey were to update ridership by the jurisdiction of residence for use in Metrobus’ operating subsidy allocation and to collect demographic, travel, and access data for Title VI compliance, system planning, and operation analyses. It was not a customer opinion survey; the focus was on ridership and travel characteristics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Light and Electron Emission as Breakdown Probes: Synergistic DC and RF Study

The project was motivated by a particular and critical need in accelerator R&D to understand vacuum breakdown and arc as it would allow for developing high gradient machines. Accelerator systems operated at high gradients are less costly and more compact. This, in turn, would enable advanced and cost-effective accelerators for future colliders. Universities and medical centers would be able to build compact accelerator machines for basic X-ray and microscopy sciences, therapy, isotope production, sterilization etc.

43 PARTICLE ACCELERATORS↗