Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data requests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Results for the Third Quarter Calendar Year 2021 Tank 50 Salt Solution Sample

In this Technical Report, the chemical and radionuclide contaminant results from the Third Quarter Calendar Year 2021 (CY21) sample of Tank 50 salt solution are presented in tabulated form. The information from this characterization will be used by Savannah River Remediation (SRR) for the transfer of aqueous waste from Tank 50 to the Saltstone Production Facility (SPF), where the waste will be treated and disposed in the Saltstone Disposal Facility. This Technical Report compares results, where applicable, to SPF Waste Acceptance Criteria (WAC) Limits and Targets that were established at the time the Tank 50 sample was obtained. The chemical and radionuclide contaminant results from the characterization of the Third Quarter CY21 sampling of Tank 50 were requested by SRR personnel via a Task Technical Request (TTR) and details of the testing are presented in the Savannah River National Laboratory (SRNL) Task Technical and Quality Assurance Plan (TTQAP). This Technical Report is part of Deliverable 2 relating to Task 1 from the SRR request. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals per Task 2 from the SRR request, will be obtained semi-annually for the 1QCY21 and 3QCY21 Tank 50 samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results for the Second Quarter Calendar Year 2021 Tank 50 Salt Solution Sample

In this Technical Report, the chemical and radionuclide contaminant results from the Second Quarter Calendar Year 2021 (CY21) sample of Tank 50 salt solution are presented in tabulated form. The information from this characterization will be used by Savannah River Remediation (SRR) for the transfer of aqueous waste from Tank 50 to the Saltstone Production Facility (SPF), where the waste will be treated and disposed in the Saltstone Disposal Facility. This Technical Report compares results, where applicable, to SPF Waste Acceptance Criteria (WAC) Limits and Targets that were established at the time the Tank 50 sample was obtained. The chemical and radionuclide contaminant results from the characterization of the Second Quarter CY21 sampling of Tank 50 were requested by SRR personnel via a Task Technical Request (TTR) and details of the testing are presented in the Savannah River National Laboratory (SRNL) Task Technical and Quality Assurance Plan (TTQAP). This Technical Report is part of Deliverable 2 relating to Task 1 from the SRR request. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals per Task 2 from the SRR request, will be obtained semi-annually for the 1QCY21 and 3QCY21 Tank 50 samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results for the January 2022 Semiannual Tank 50 Salt Solution Sample

In this Technical Report, the chemical and radionuclide contaminant results from the January 2022 Semiannual sample of Tank 50 salt solution are presented in tabulated form. The information from this characterization will be used by Savannah River Mission Completion (SRMC) for the transfer of aqueous waste from Tank 50 to the Saltstone Production Facility (SPF), where the waste will be treated and disposed in the Saltstone Disposal Facility. This Technical Report compares results, where applicable, to SPF Waste Acceptance Criteria (WAC) LIMITS and TARGETS that were established at the time the Tank 50 sample was obtained. The chemical and radionuclide contaminant results from the characterization of the January 2022 semiannual sampling of Tank 50 were requested by SRMC personnel via a Task Technical Request (TTR) and details of the testing are presented in the Savannah River National Laboratory (SRNL) Task Technical and Quality Assurance Plan (TTQAP). This Technical Report is part of Deliverable 2 relating to Task 1 from the SRMC request. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals per Task 2 from the RMC request, will be obtained semiannually for the January 2022 and July 2022 Tank 50 samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results for the July 2022 Semiannual Tank 50 Salt Solution Sample

In this Technical Report, the chemical and radionuclide contaminant results from the July 2022 Semiannual sample of Tank 50 salt solution are presented in tabulated form. The information from this characterization will be used by Savannah River Mission Completion (SRMC) for the transfer of aqueous waste from Tank 50 to the Saltstone Production Facility (SPF), where the waste will be treated and disposed in the Saltstone Disposal Facility. This Technical Report compares results, where applicable, to SPF Waste Acceptance Criteria (WAC) LIMITS and TARGETS that were established at the time the Tank 50 sample was obtained. The chemical and radionuclide contaminant results from the characterization of the July 2022 semiannual sampling of Tank 50 were requested by SRMC personnel via a Task Technical Request (TTR) and details of the testing are presented in the Savannah River National Laboratory (SRNL) Task Technical and Quality Assurance Plan (TTQAP). This Technical Report is part of Deliverable 2 relating to Task 1 from the SRMC request. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals per Task 2 from the SRMC request, will be obtained semiannually for the January 2022 and July 2022 Tank 50 samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Earth System Grid (ESG) Data Node Software Stack

The ESG-CET system consist of two major components: 1) Gateways that support portal services, which serve as interfaces to end-users who can search, discover, and request data and data products, and 2) Data Nodes where the data actually resides. The Data is "published" to the Data Node, which makes the data visible to a Gateway and enables its delivery to end-users. It is expected that Gateways will only be installed by a small number of centers devoted to serving data (e.g., LLNL/PCMDI, NCAR, GFDL, DADC, DKRZ, ANU, JAMSTEC), whereas it is hoped that most climate modeling centers will install the Data Node software through which they can serve their model output.

Williams, D. N.↗

Nuclear data for nuclear transmutation

Current status on nuclear data for the study of nuclear transmutation of radioactive wastes is reviewed, mainly focusing on neutron capture reactions. It is stressed that the highest-precision frontier research in nuclear data measurements should be a key to satisfy the target accuracies on the nuclear data requested for realizing the nuclear transmutation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Stand-alone and Network Capable Pocket Radiation Detection System

A multi-functional and networked pocket radiation detection system has been developed at the Idaho National Laboratory (INL) capable of detecting and storing gamma ray and neutron data. The device can be used as a stand-alone device or in conjunction with an array to cover a small or large area. The device has programmable alarm trigger levels that can be modified for specific applications. The data is stored with a date/time stamp and can be transferred and viewed on a PDA via direct connection or, in networked configuration, wireless connection to a remote central facility upon request. Data functional/bench tests have been completed successfully and the device was demonstrated to detect radiation from a 55.6 uCi Cf-252 source at 5 meters and from 1.4 mCi Cf-252 source at 10 meters which exceeds both ANSI and IAEA standards for pocket radiation detection. In terms of sensitivity, this detection system detects neutron and gamma-ray fields down to 10 micro rem/hr levels and therefore can find the location of the radioactive source quickly. The detection system is small enough to be put in a pocket or clipped to a belt.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Tolerating memory stack failures in multi-stack systems

Memory management circuitry and processes operate to improve reliability of a group of memory stacks, providing that if a memory stack or a portion thereof fails during the product's lifetime, the system may still recover with no errors or data loss. A front-end controller receives a block of data requested to be written to memory, divides the block into sub-blocks, and creates a new redundant reliability sub-block. The sub-blocks are then written to different memory stacks. When reading data from the memory stacks, the front-end controller detects errors indicating a failure within one of the memory stacks, and recovers corrected data using the reliability sub-block. The front-end controller may monitor errors for signs of a stack failure and disable the failed stack.

Mappouras, Georgios↗

Asynchronous cache flushing

Proactive flush logic in a computing system is configured to perform a proactive flush operation to flush data from a first memory in a first computing device to a second memory in response to execution of a non-blocking flush instruction. Reactive flush logic in the computing system is configured to, in response to a memory request issued prior to completion of the proactive flush operation, interrupt the proactive flush operation and perform a reactive flush operation to flush requested data from the first memory to the second memory.

97 MATHEMATICS AND COMPUTING↗

VisIO: enabling interactive visualization of ultra-scale, time-series data via high-bandwidth distributed I/O systems

Petascale simulations compute at resolutions ranging into billions of cells and write terabytes of data for visualization and analysis. Interactive visuaUzation of this time series is a desired step before starting a new run. The I/O subsystem and associated network often are a significant impediment to interactive visualization of time-varying data; as they are not configured or provisioned to provide necessary I/O read rates. In this paper, we propose a new I/O library for visualization applications: VisIO. Visualization applications commonly use N-to-N reads within their parallel enabled readers which provides an incentive for a shared-nothing approach to I/O, similar to other data-intensive approaches such as Hadoop. However, unlike other data-intensive applications, visualization requires: (1) interactive performance for large data volumes, (2) compatibility with MPI and POSIX file system semantics for compatibility with existing infrastructure, and (3) use of existing file formats and their stipulated data partitioning rules. VisIO, provides a mechanism for using a non-POSIX distributed file system to provide linear scaling of 110 bandwidth. In addition, we introduce a novel scheduling algorithm that helps to co-locate visualization processes on nodes with the requested data. Testing using VisIO integrated into Para View was conducted using the Hadoop Distributed File System (HDFS) on TACC's Longhorn cluster. A representative dataset, VPIC, across 128 nodes showed a 64.4% read performance improvement compared to the provided Lustre installation. Also tested, was a dataset representing a global ocean salinity simulation that showed a 51.4% improvement in read performance over Lustre when using our VisIO system. VisIO, provides powerful high-performance I/O services to visualization applications, allowing for interactive performance with ultra-scale, time-series data.

97 MATHEMATICS AND COMPUTING↗

Bridging the Gap on Data, Metrics, and Analyses for Grid Resilience to Weather Events: Information that utilities can provide regulators, state energy offices, and other stakeholders

A growing number of states require regulated utilities to file resilience plans to improve the electric grid’s ability to anticipate, withstand, adapt to and recover from increasingly severe weather events. This report aims to help state regulators identify and request data, metrics, and analyses from utilities and use it in decisions on utility resilience plans and investments. The report reviews state requirements and utility plans focused on overall grid resilience, climate change resilience and vulnerabilities, infrastructure modernization, storm protection, and wildfire mitigation. It details types of data, metrics, and analyses across five categories--and provides examples of each from the utility plans. The first category is vulnerability assessments, or evaluations of the susceptibility of systems, communities, or assets to potential harm from identified hazards. The second is data on hazards and the exposure of utility assets and customers to these hazards. The third is attribute metrics, or system characteristics that contribute to or describe the resilience of a system. The fourth is performance metrics, which are impacts of resilience investments on system performance--typically a reduction of negative impacts from hazard events. Finally, evaluation and prioritization are analyses that utilities conduct to estimate impacts from resilience measures (evaluation) and prioritize measures based on costs and estimated impacts (prioritization). The report concludes with examples of key trends and emerging best practices for states and utilities, and identifies areas for further research.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Parallel In Situ Coupling of a Simulation with a Fully Featured Visualization System

There is a widening gap between compute performance and the ability to store computation results. Complex scientific codes are the most affected since they must save massive files containing meshes and fields for offline analysis. Time and storage costs instead dictate that data analysis and visualization be combined with the simulations themselves, being done in situ so data are transformed to a manageable size before they are stored. Earlier approaches to in situ processing involved combining specific visualization algorithms into the simulation code, limiting flexibility. We introduce a new library which instead allows a fully-featured visualization tool, VisIt, to request data as needed from the simulation and apply visualization algorithms in situ with minimal modification to the application code.

99 GENERAL AND MISCELLANEOUS↗

Analytical Functions for 200 West Pump-and-Treat SCADA Sensor Data

Historical operations at the U.S. Department of Energy’s Hanford Site included disposal of waste fluids to the subsurface in the 200 West Area on the Hanford Central Plateau. Subsequent infiltration of fluids has resulted in groundwater contamination with carbon tetrachloride, nitrate, uranium, technetium-99, and other contaminants. A pump-and-treat (P&T) system, with an extraction/injection well network and an aboveground treatment plant, was implemented as part of interim and final remedies in the 200 West area. The HYPATIA single-page web application (part of the SOCRATES suite) is being developed to provide access to and analysis of chemistry and treatment facility sensor data for this 200 West P&T system. For the web application, analytical algorithms were developed to perform summing, differencing, smoothing, outlier detection, change-point detection, mass flow rate, and injectivity calculations on the data. Candidate algorithms were identified and tested, with the best-performing algorithms then assembled for implementation in HYPATIA. Because HYPATIA is hosted on the Amazon Web Services (AWS) cloud computing platform, algorithms were implemented in a back-end AWS Lambda function that can be called by the HYPATIA front end. The Lambda function applies the requested data processing to specified data via functions written in R, Python, and JavaScript. Development, testing, and review of the data analysis algorithms was completed under an NQA-1 quality program. This new HYPATIA functionality will provide information to support site decisions regarding P&T system performance and optimization.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Response functions for Logarithnically Spaced Interference Filters Manufactured for Dark Energy Missions

This data package pertains to test filters produced for the SNAP project. Filter #7 was produced in accordance with the SNAP Test Filter Spec r6.t, including several exceptions taken by JDSU and documented in the JDSU sales order. A set of three Filter #7 parts have been produced for the project, as well as two witnesses for cold environment testing. SNAP Test Filter Spec r6.t requests data to accompany the filters; that is the purpose of this document.

47 OTHER INSTRUMENTATION↗

Data-Driven Multi-Step Demand Prediction for Ride-Hailing Services Using Convolutional Neural Network

Ride-hailing services are growing rapidly and becoming one of the most disruptive technologies in the transportation realm. Accurate prediction of ride-hailing trip demand not only enables cities to better understand people's activity patterns, but also helps ride-hailing companies and drivers make informed decisions to reduce deadheading vehicle miles traveled, traffic congestion, and energy consumption. In this study, a convolutional neural network (CNN)-based deep learning model is proposed for multi-step ride-hailing demand prediction using the trip request data in Chengdu, China, offered by DiDi Chuxing. The CNN model is capable of accurately predicting the ride-hailing pick-up demand at each 1-km by 1-km zone in the city of Chengdu for every 10 min. Compared with another deep learning model based on long short-term memory, the CNN model is 30% faster for the training and predicting process. The proposed model can also be easily extended to make multi-step predictions, which would benefit the on-demand shared autonomous vehicles applications and fleet operators in terms of supply-demand rebalancing. The prediction error attenuation analysis shows that the accuracy stays acceptable as the model predicts more steps.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Determining Columbia and Snake River Project Tailrace and Forebay Zones of Hydraulic Influence using MASS2 Modeling

Although fisheries biology studies are frequently performed at US Army Corps of Engineers (USACE) projects along the Columbia and Snake Rivers, there is currently no consistent definition of the ``forebay'' and ``tailrace'' regions for these studies. At this time, each study may use somewhat arbitrary lines (e.g., the Boat Restriction Zone) to define the upstream and downstream limits of the study, which may be significantly different at each project. Fisheries researchers are interested in establishing a consistent definition of project forebay and tailrace regions for the hydroelectric projects on the lower Columbia and Snake rivers. The Hydraulic Extent of a project was defined by USACE (Brad Eppard, USACE-CENWP) as follows: The river reach directly upstream (forebay) and downstream (tailrace) of a project that is influenced by the normal range of dam operations. Outside this reach, for a particular river discharge, changes in dam operations cannot be detected by hydraulic measurement. The purpose of this study was to, in consultation with USACE and regional representatives, develop and apply a consistent set of criteria for determining the hydraulic extent of each of the projects in the lower Columbia and Snake rivers. A 2D depth-averaged river model, MASS2, was applied to the Snake and Columbia Rivers. New computational meshes were developed most reaches and the underlying bathymetric data updated to the most current survey data. The computational meshes resolved each spillway bay and turbine unit at each project and extended from project to project. MASS2 was run for a range of total river flows and each flow for a range of project operations at each project. The modeled flow was analyzed to determine the range of velocity magnitude differences and the range of flow direction differences at each location in the computational mesh for each total river flow. Maps of the differences in flow direction and velocity magnitude were created. USACE fishery biologists requested data analysis to determine the project hydraulic extent based on the following criteria: 1) For areas where the mean velocities are less than 4 ft/s, the water velocity differences between operations are not greater than 0.5 ft/sec and /or the differences in water flow direction are not greater than 10 degrees, 2) If mean water velocity is 4.0 ft/second or greater the boundary is determined using the differences in water flow direction (i.e., not greater than 10 degrees). Based on these criteria, and excluding areas with a mean velocity of less than 0.1 ft/s (within the error of the model), a final set of graphics were developed that included data from all flows and all operations. Although each hydroelectric project has a different physical setting, there were some common results. The downstream hydraulic extent tended to be greater than the hydraulic extent in the forebay. The hydraulic extent of the projects tended to be larger at the mid-range flows. At higher flows, the channel geometry tends to reduce the impact of project operations.

54 ENVIRONMENTAL SCIENCES↗

GRACC: New generation of the OSG accounting

Throughout the last decade the Open Science Grid (OSG) has been fielding requests from user communities, resource owners, and funding agencies to provide information about utilization of OSG resources. Requested data include traditional accounting - core-hours utilized - as well as users certicate Distinguished Name, their affiliations, and eld of science. The OSG accounting service, Gratia, developed in 2006, is able to provide this information and much more. However, with the rapid expansion and transformation of the OSG resources and access to them, we are faced with several challenges in adapting and maintaining the current accounting service. The newest changes include, but are not limited to, acceptance of users from numerous university campuses, whose jobs are flocking to OSG resources, expansion into new types of resources (public and private clouds, allocation-based HPC resources, and GPU farms), migration to pilot-based systems, and migration to multicore environments. In order to have a scalable, sustainable and expandable accounting service for the next few years, we are embarking on the development of the next-generation OSG accounting service, GRACC, that will be based on open-source technology and will be compatible with the existing system. It will consist of swappable, independent components, such as Logstash, Elasticsearch, Grafana, and RabbitMQ, that communicate through a data exchange. GRACC will continue to interface EGI and XSEDE accounting services and provide information in accordance with existing agreements. Lastly, we will present the current architecture and working prototype.

97 MATHEMATICS AND COMPUTING↗

Results for the first quarter calendar year 2017 tank 50H salt solution sample

In this memorandum, the chemical and radionuclide contaminant results from the First Quarter Calendar Year 2017 (CY17) sample of Tank 50H salt solution are presented in tabulated form. The First Quarter CY17 Tank 50H samples [a 200 mL sample obtained 6” below the surface (HTF-50-17-7) and a 1 L sample obtained 66” from the tank bottom (HTF-50-17-8)] were obtained on January 15, 2017 and received at Savannah River National Laboratory (SRNL) on January 16, 2017. Prior to obtaining the samples from Tank 50H, a single pump was run at least 4.4 hours and the samples were pulled immediately after pump shut down. All volatile organic analysis (VOA) and semi-volatile organic analysis (SVOA) were performed on the surface sample and all other analyses were performed on the variable depth sample. The information from this characterization will be used by Savannah River Remediation (SRR) for the transfer of aqueous waste from Tank 50H to the Saltstone Production Facility, where the waste will be treated and disposed of in the Saltstone Disposal Facility. This memorandum compares results, where applicable, to Saltstone Waste Acceptance Criteria (WAC) limits and targets. The chemical and radionuclide contaminant results from the characterization of the First Quarter CY17 sampling of Tank 50H were requested by SRR personnel and details of the testing are presented in the SRNL Task Technical and Quality Assurance Plan (TTQAP). This memorandum is part of Deliverable 2 from SRR request. Data pertaining to the regulatory limits for Resource Conservation and Recovery Act (RCRA) metals will be documented at a later time per the TTQAP for the Tank 50H saltstone task.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗