At least 55 records · Page 3

Eddy-current measurements of thickness of high-temperature coatings

The eddy-current technique was applied to measuring the thickness of a fused silicide coating on a refractory alloy slab. Phase and magnitude of the test signal were measured at four places in 13 different samples, and thickness of coating was computed on the basis of each of these quantities. These results were then compared with those obtained by conventional metallographic methods. Phase-based measurements were most reliable, and the maximum error between the metallographically determined thickness and the thickness as determined by the least squares fit to the phase measurements was less than 0.01 mm (about 1%). Photomicrography of a typical sample shows that a large source of error resides in the fact that two regions - an outer rough region and an inner uniform region - of the coating layer exist rather than the single region upon which the calculations were based.

Dodd, C. V.↗

Global Electric Circuit Implications of Total Current Measurements over Electrified Clouds

We determined total conduction (Wilson) currents and flash rates for 850 overflights of electrified clouds spanning regions including the Southeastern United States, the Western Atlantic Ocean, the Gulf of Mexico, Central America and adjacent oceans, Central Brazil, and the South Pacific. The overflights include storms over land and ocean, with and without lightning, and with positive and negative Wilson currents. We combined these individual storm overflight statistics with global diurnal lightning variation data from the Lightning Imaging Sensor (LIS) and Optical Transient Detector (OTD) to estimate the thunderstorm and electrified shower cloud contributions to the diurnal variation in the global electric circuit. The contributions to the global electric circuit from lightning producing clouds are estimated by taking the mean current per flash derived from the overflight data for land and ocean overflights and combining it with the global lightning rates (for land and ocean) and their diurnal variation derived from the LIS/OTD data. We estimate the contribution of non-lightning producing electrified clouds by assuming several different diurnal variations and total non-electrified storm counts to produce estimates of the total storm currents (lightning and non-lightning producing storms). The storm counts and diurnal variations are constrained so that the resultant total current diurnal variation equals the diurnal variation in the fair weather electric field (+/-15%). These assumptions, combined with the airborne and satellite data, suggest that the total mean current in the global electric circuit ranges from 2.0 to 2.7 kA, which is greater than estimates made by others using other methods.

Mach, Douglas M.↗

Eddy-Current Measurement Of Turning Or Curvature

Rotatable conductive plate covers sensing coil to varying degree. Curvature of pipe at remote or otherwise inaccessible location inside pipe measured using relatively simple angular-displacement eddy-current probe. Crawler and sensor assemblies move along inside of pipe on wheels. Conductive plate pivots to follow curvature of pipe, partly covering one of eddy-current coils to degree depending on local curvature on pipe.

Chern, Engmin J.↗

Charge Exchange Contribution to the Decay of the Ring Current, Measured by Energetic Neutral Atoms (ENAs)

In this paper we calculate the contribution of charge exchange to the decay of the ring current. Past works have suggested that charge exchange of ring current protons is primarily responsible for the decay of the ring current during the late recovery phase, but there is still much debate about the fast decay of the early recovery phase. We use energetic neutral atom (ENA) measurements from Polar to calculate the total ENA energy escape. To get the total ENA escape we apply a forward modeling technique, and to estimate the total ring current energy escape we use the Dessler-Parker-Sckopke relationship. We find that during the late recovery phase of the March 10, 1998 storm ENAs with energies greater than 17.5 keV can account for 75% of the estimated energy loss from the ring current. During the fast recovery the measured ENAs can only account for a small portion of the total energy loss. We also find that the lifetime of the trapped ions is significantly shorter during the fast recovery phase than during the late recovery phase, suggesting that different processes are operating during the two phases.

Jorgensen, A. M.↗

Forward-bias capacitance and current measurements for determining lifetimes and band narrowing in p-n junction solar cells

A new method is described and illustrated for determining the minority-carrier diffusion length and lifetime in the base region of p-n junction solar cells. The method requires only capacitance measurements at the device terminals and its accuracy is estimated to be + or - 5%. It is applied to a set of silicon p-n junction devices and the values of the diffusion lengths agree with those obtained using the current response to X-ray excitation but disagree with those obtained by the OCVD method. The reasons for the relative inaccuracy of OCVD applied to silicon devices are discussed. The capacitance method includes corrections for a two-dimensional fringing effects which occur in small area devices. For a device having highly-doped base region and surface (emitter) layer, the method can be extended to enable the determination of material properties of the degenerately doped surface layer. These material properties include the phenomenological emitter lifetime and a measure of the energy band-gap narrowing in the emitter. An alternate method for determining the energy band-gap narrowing from temperature dependence of emitter current is discussed and demonstrated.

Neugroschel, A.↗

Global Electric Circuit Implications of Combined Aircraft Storm Electric Current Measurements and Satellite-Based Diurnal Lightning Statistics

Using rotating vane electric field mills and Gerdien capacitors, we measured the electric field profile and conductivity during 850 overflights of thunderstorms and electrified shower clouds (ESCs) spanning regions including the Southeastern United States, the Western Atlantic Ocean, the Gulf of Mexico, Central America and adjacent oceans, Central Brazil, and the South Pacific. The overflights include storms over land and ocean, and with positive and negative fields above the storms. Over three-quarters (78%) of the land storms had detectable lightning, while less than half (43%) of the oceanic storms had lightning. Integrating our electric field and conductivity data, we determined total conduction currents and flash rates for each overpass. With knowledge of the storm location (land or ocean) and type (with or without lightning), we determine the mean currents by location and type. The mean current for ocean thunderstorms is 1.7 A while the mean current for land thunderstorms is 1.0 A. The mean current for ocean ESCs 0.41 A and the mean current for land ESCs is 0.13 A. We did not find any significant regional or latitudinal based patterns in our total conduction currents. By combining the aircraft derived storm currents and flash rates with diurnal flash rate statistics derived from the Lightning Imaging Sensor (LIS) and Optical Transient Detector (OTD) low Earth orbiting satellites, we reproduce the diurnal variation in the global electric circuit (i.e., the Carnegie curve) to within 4% for all but two short periods of time. The agreement with the Carnegie curve was obtained without any tuning or adjustment of the satellite or aircraft data. Given our data and assumptions, mean contributions to the global electric circuit are 1.1 kA (land) and 0.7 kA (ocean) from thunderstorms, and 0.22 kA (ocean) and 0.04 (land) from ESCs, resulting in a mean total conduction current estimate for the global electric circuit of 2.0 kA. Mean storm counts are 1100 for land thunderstorms, 530 for ocean ESCs, 390 for ocean thunderstorms, and 330 for land ESCs.

Mach, Douglas M.↗

Initiation current measurements for hot bridgewire devices

One-shot type testing of hot bridgewire explosive cartridges provides the weakest possible firing characteristic data. One-shot type testing includes the Bruceton and the Probit methods, and all their off-shoots. One-shot testing is used for only one reason: the fear of 'dudding.' Modern programmable power supplies and oscilloscopes can now be used to obtain data with no fear of dudding. Any continued use of these old, one-shot type test methods is irresponsible behavior. Our society deserves better testing methods and will get them through the courts if we cannot make these changes on our own.

OBarr, Gerald L.↗