Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coverage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Constellation Study for Optimized Target Access and Coverage

We have performed a low earth orbiting satellite constellation design parameter space study to determine optimized constellations that satisfies mission goals while minimizing total system costs. Because this is a generic study, we developed a generalized set of mission requirements that would meet the needs of several different types of space missions. Figure of merit parameters were defined to help rank the different constellations under study. Instead of performing a full, multi-dimensional parameter space study, we instead focused on a few exemplar cases. For this generic mission, the baseline requirements were as follows: altitude: 700km, total number of satellites per constellation: 40-100, world coverage: 100% coverage or maximize coverage of populated latitudes, polar coverage: some but not 100% required, multi-ball observations: 2- & 3-ball coverage desired, and target coverage: full coverage or up to 5 minute observing gap for 1-ball coverage at all latitudes. For added conservatism, the minimum target observing elevation angle was 10-degrees and the minimum acceptable time on target was 1 minute. We also only performed the calculations for a Walker constellation (defined as M/M/IP or #planes/# satellites per plane/interplane satellite spacing) instead of “streets-of-coverage” constellations, which at high inclinations can satisfy coverage requirements with slightly fewer satellites.

47 OTHER INSTRUMENTATION↗

Three-Dimensional Analysis of Deep Space Network Antenna Coverage

There is a need to understand NASA s Deep Space Network (DSN) coverage gaps and any limitations to provide redundant communication coverage for future deep space missions, especially for manned missions to Moon and Mars. The DSN antennas are required to provide continuous communication coverage for deep space flights, interplanetary missions, and deep space scientific observations. The DSN consists of ground antennas located at three sites: Goldstone in USA, Canberra in Australia, and Madrid in Spain. These locations are not separated by the exactly 120 degrees and some DSN antennas are located in the bowl-shaped mountainous terrain to shield against radiofrequency interference resulting in a coverage gap in the southern hemisphere for the current DSN architecture. To analyze the extent of this gap and other coverage limitations, simulations of the DSN architecture were performed. In addition to the physical properties of the DSN assets, the simulation incorporated communication forward link calculations and azimuth/elevation masks that constrain the effects of terrain for each DSN antenna. Analysis of the simulation data was performed to create coverage profiles with the receiver settings at a deep space altitudes ranging from 2 million to 10 million km and a spherical grid resolution of 0.25 degrees with respect to longitude and latitude. With the results of these simulations, two- and three-dimensional representations of the area without communication coverage and area with coverage were developed, showing the size and shape of the communication coverage gap projected in space. Also, the significance of this communication coverage gap is analyzed from the simulation data.

Kegege, Obadiah↗

Correlation between infrared spectra features and coverage of different adsorption sites for the NO/Pd(111) system

This study investigates the adsorption of nitric oxide (NO) on Pd(111) surfaces at 200 K using infrared reflection absorption spectroscopy (IRRAS). Peak positions and areas are used as proxies for tracking coverage of different species, serving as groundwork for in-situ experiments that need real-time tracking of surface species. Here, we derived a mathematical model correlating NO coverage with dose, consistent with the Molecular Langmuir Model. Distinct correlations are observed between coverage and spectral features (peak position and peak area for the NO vibration): at lower coverages (θ<0.6), the total integrated peak areas are linearly corelated to coverage; at higher coverages (θ>0.6), the peak center for a compressed-hollow site becomes the primary coverage indicator, showing a linear relationship between wavenumber and coverage. Note that this study addresses coverages below saturation. These findings refine our understanding of NO adsorption and establish a foundation for real-time in situ transient kinetics studies of chemical reactions involving NO on Pd(111).

25 ENERGY STORAGE↗

Sensitivity of postplanning target and OAR coverage estimates to dosimetric margin distribution sampling parameters

Purpose: A dosimetric margin (DM) is the margin in a specified direction between a structure and a specified isodose surface, corresponding to a prescription or tolerance dose. The dosimetric margin distribution (DMD) is the distribution of DMs over all directions. Given a geometric uncertainty model, representing inter- or intrafraction setup uncertainties or internal organ motion, the DMD can be used to calculate coverage Q, which is the probability that a realized target or organ-at-risk (OAR) dose metric D{sub v} exceeds the corresponding prescription or tolerance dose. Postplanning coverage evaluation quantifies the percentage of uncertainties for which target and OAR structures meet their intended dose constraints. The goal of the present work is to evaluate coverage probabilities for 28 prostate treatment plans to determine DMD sampling parameters that ensure adequate accuracy for postplanning coverage estimates. Methods: Normally distributed interfraction setup uncertainties were applied to 28 plans for localized prostate cancer, with prescribed dose of 79.2 Gy and 10 mm clinical target volume to planning target volume (CTV-to-PTV) margins. Using angular or isotropic sampling techniques, dosimetric margins were determined for the CTV, bladder and rectum, assuming shift invariance of the dose distribution. For angular sampling, DMDs were sampled at fixed angular intervals {omega} (e.g., {omega}=1 deg., 2 deg., 5 deg., 10 deg., 20 deg.). Isotropic samples were uniformly distributed on the unit sphere resulting in variable angular increments, but were calculated for the same number of sampling directions as angular DMDs, and accordingly characterized by the effective angular increment {omega}{sub eff}. In each direction, the DM was calculated by moving the structure in radial steps of size {delta}(=0.1,0.2,0.5,1 mm) until the specified isodose was crossed. Coverage estimation accuracy {Delta}Q was quantified as a function of the sampling parameters {omega} or {omega}{sub eff} and {delta}. Results: The accuracy of coverage estimates depends on angular and radial DMD sampling parameters {omega} or {omega}{sub eff} and {delta}, as well as the employed sampling technique. Target |{Delta}Q|<1% and OAR |{Delta}Q|<3% can be achieved with sampling parameters {omega} or {omega}{sub eff}=20 deg., {delta}=1 mm. Better accuracy (target |{Delta}Q|<0.5% and OAR |{Delta}Q|<{approx}1%) can be achieved with {omega} or {omega}{sub eff}=10 deg., {delta}=0.5 mm. As the number of sampling points decreases, the isotropic sampling method maintains better accuracy than fixed angular sampling. Conclusions: Coverage estimates for post-planning evaluation are essential since coverage values of targets and OARs often differ from the values implied by the static margin-based plans. Finer sampling of the DMD enables more accurate assessment of the effect of geometric uncertainties on coverage estimates prior to treatment. DMD sampling with {omega} or {omega}{sub eff}=10 deg. and {delta}=0.5 mm should be adequate for planning purposes.

60 APPLIED LIFE SCIENCES↗

Annual Cycles of Multiyear Sea Ice Coverage of the Arctic Ocean: 1999-2003

For the years 1999-2003, we estimate the time-varying perennial ice zone (PIZ) coverage and construct the annual cycles of multiyear (MY, including second year) ice coverage of the Arctic Ocean using QuikSCAT backscatter, MY fractions from RADARSAT, and the record of ice export from satellite passive microwave observations. An area balance approach extends the winter MY coverage from QuikSCAT to the remainder of the year. From these estimates, the coverage of MY ice at the beginning of each year is 3774 x 10(exp 3) sq km (2000), 3896 x 10(exp 3) sq km (2001), 4475 x 10(exp 3) sq km (2002), and 4122 x 10(exp 3) sq km (2003). Uncertainties in coverage are approx.150 x 10(exp 3) sq km. In the mean, on 1 January, MY ice covers approx.60% of the Arctic Ocean. Ice export reduces this coverage to approx.55% by 1 May. From the multiple annual cycles, the area of first-year (FY) ice that survives the intervening summers are 1192 x 10(exp 3) sq km (2000), 1509 x 10(exp 3) sq km (2001), and 582 x 10(exp 3) sq km (2002). In order for the MY coverage to remain constant from year to year, these replenishment areas must balance the overall area export and melt during the summer. The effect of the record minimum in Arctic sea ice area during the summer of 2002 is seen in the lowest area of surviving FY ice of the three summers. In addition to the spatial coverage, the location of the PIZ is important. One consequence of the unusual location of the PIZ at the end of the summer of 2002 is the preconditioning for enhanced export of MY ice into the Barents and Kara seas. Differences between the minimums in summer sea ice coverage from our estimates and passive microwave observations are discussed.

Arctic Ocean↗

Coverage Metrics for Requirements-Based Testing: Evaluation of Effectiveness

In black-box testing, the tester creates a set of tests to exercise a system under test without regard to the internal structure of the system. Generally, no objective metric is used to measure the adequacy of black-box tests. In recent work, we have proposed three requirements coverage metrics, allowing testers to objectively measure the adequacy of a black-box test suite with respect to a set of requirements formalized as Linear Temporal Logic (LTL) properties. In this report, we evaluate the effectiveness of these coverage metrics with respect to fault finding. Specifically, we conduct an empirical study to investigate two questions: (1) do test suites satisfying a requirements coverage metric provide better fault finding than randomly generated test suites of approximately the same size?, and (2) do test suites satisfying a more rigorous requirements coverage metric provide better fault finding than test suites satisfying a less rigorous requirements coverage metric? Our results indicate (1) only one coverage metric proposed -- Unique First Cause (UFC) coverage -- is sufficiently rigorous to ensure test suites satisfying the metric outperform randomly generated test suites of similar size and (2) that test suites satisfying more rigorous coverage metrics provide better fault finding than test suites satisfying less rigorous coverage metrics.

Staats, Matt↗

Effect of hydrogen coverage on hydrogenation of o -cresol on Pt(111)

The conversion of phenolics over metal catalysts is an important process for upgrading biofuels. With density functional calculations, hydrogenation of o-cresol on the hydrogen-covered Pt(111) surface was investigated. Here, the results show that the coverage of hydrogen plays a significant role in the reaction rate while it does not affect the reaction selectivity. The reaction barriers of the hydrogenation process leading to the formation of both 2-methyl-cyclohexanone (the intermediate product) and 2-methyl-cyclohexanol (the final product) at high H coverages (~ 1 ML) are found to be smaller by 0.14–0.69 eV than those at lower H coverages (~ 1/25 ML). After both hydrogen and cresol are adsorbed on Pt(111) from their initial gas phase state, the reaction energy of each hydrogenation step on the surface is also dependent on the hydrogen coverage. On the H-covered Pt(111) surface, most steps of hydrogenation involve exothermic reactions when the hydrogen coverage is high while they are endothermic reactions at low hydrogen coverages. The differences in reaction rate and reaction energy between high and low H coverages can be understood with the coverage-dependent bonding strength and configurations.

08 HYDROGEN↗

Controlled site coverage of strong metal–support interaction (SMSI) on Pd NP catalysts

Here, strong metal–support interaction catalysts have been shown to improve desired product selectivity at the cost of fractional rates due to active site coverage. The goal of this study was to determine if the active site coverage of metallic nanoparticles could be controlled to lower levels than have been previously reported in SMSI catalysts with the aim of improving the rate while maintaining high selectivity. 2Pd–XTi/SiO 2 (2 wt% Pd, X wt% Ti) strong metal–support interaction (SMSI) catalysts with Ti loadings between 0–1.0 wt% were synthesized to control Pd nanoparticle coverage. Calcination at 450 °C and reduction at 550 °C were sufficient for forming ~2 nm sized Pd particles in all catalysts. Increasing the Ti loading from 0.1 to 1.0 wt% increased the surface coverage from 40 to 85% at a fixed reduction temperature of 550 °C. The IR spectra of the SMSI catalysts were similar with a high fraction of linear bonded CO which was much higher than that of Pd nanoparticles of similar size. The SMSI overlayer could be removed by oxidation at 350 °C and re-reduction at 200 °C. EXAFS of the oxidized catalysts indicates that nearly full oxidation of the metallic nanoparticle was required to remove the SMSI overlayer. Oxidation temperatures from 30 to 300 °C partially oxidized the Pd nanoparticles and subsequent re-reduction at 200 °C partially decreases the SMSI coverage. The fractional surface coverage was determined by measuring the rate of propylene hydrogenation with and without the SMSI overlayer. Increasing the reduction temperature from 200 to 550 °C increased the SMSI coverage from 0 to 85% depending on the Ti loading and temperature. In conclusion, after reduction at 550 °C and oxidation at 350 °C, the range of coverages varied between ~10% with 0.1 wt% Ti after re-reduction at 300 °C and ~85% with 1 wt% Ti after reduction at 550 °C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single-Isocenter Multiple-Target Stereotactic Radiosurgery: Risk of Compromised Coverage

Purpose: To determine the dosimetric effects of rotational errors on target coverage using volumetric modulated arc therapy (VMAT) for multitarget stereotactic radiosurgery (SRS). Methods and Materials: This retrospective study included 50 SRS cases, each with 2 intracranial planning target volumes (PTVs). Both PTVs were planned for simultaneous treatment to 21 Gy using a single-isocenter, noncoplanar VMAT SRS technique. Rotational errors of 0.5°, 1.0°, and 2.0° were simulated about all axes. The dose to 95% of the PTV (D95) and the volume covered by 95% of the prescribed dose (V95) were evaluated using multivariate analysis to determine how PTV coverage was related to PTV volume, PTV separation, and rotational error. Results: At 0.5° rotational error, D95 values and V95 coverage rates were ≥95% in all cases. For rotational errors of 1.0°, 7% of targets had D95 and V95 values <95%. Coverage worsened substantially when the rotational error increased to 2.0°: D95 and V95 values were >95% for only 63% of the targets. Multivariate analysis showed that PTV volume and distance to isocenter were strong predictors of target coverage. Conclusions: The effects of rotational errors on target coverage were studied across a broad range of SRS cases. In general, the risk of compromised coverage increased with decreasing target volume, increasing rotational error and increasing distance between targets. Multivariate regression models from this study may be used to quantify the dosimetric effects of rotational errors on target coverage given patient-specific input parameters of PTV volume and distance to isocenter.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deep Space Network and Lunar Network Communication Coverage of the Moon

In this article, we describe the communication coverage analysis for the lunar network and the Earth ground stations. The first part of this article focuses on the direct communication coverage of the Moon from the Earth's ground stations. In particular, we assess the coverage performance of the Moon based on the existing Deep Space Network (DSN) antennas and the complimentary coverage of other potential stations at Hartebeesthoek, South Africa and at Santiago, Chile. We also address the coverage sensitivity based on different DSN antenna scenarios and their capability to provide single and redundant coverage of the Moon. The second part of this article focuses on the framework of the constrained optimization scheme to seek a stable constellation six relay satellites in two planes that not only can provide continuous communication coverage to any users on the Moon surface, but can also deliver data throughput in a highly efficient manner.

lunar network↗

A Flexible and Non-instrusive Approach for Computing Complex Structural Coverage Metrics

Software analysis tools and techniques often leverage structural code coverage information to reason about the dynamic behavior of software. Existing techniques instrument the code with the required structural obligations and then monitor the execution of the compiled code to report coverage. Instrumentation based approaches often incur considerable runtime overhead for complex structural coverage metrics such as Modified Condition/Decision (MC/DC). Code instrumentation, in general, has to be approached with great care to ensure it does not modify the behavior of the original code. Furthermore, instrumented code cannot be used in conjunction with other analyses that reason about the structure and semantics of the code under test. In this work, we introduce a non-intrusive preprocessing approach for computing structural coverage information. It uses a static partial evaluation of the decisions in the source code and a source-to-bytecode mapping to generate the information necessary to efficiently track structural coverage metrics during execution. Our technique is flexible; the results of the preprocessing can be used by a variety of coverage-driven software analysis tasks, including automated analyses that are not possible for instrumented code. Experimental results in the context of symbolic execution show the efficiency and flexibility of our nonintrusive approach for computing code coverage information

DO-178C↗

Conventional High-Dose-Rate Brachytherapy With Concomitant Complementary IMRT Boost: A Novel Approach for Improving Cervical Tumor Dose Coverage

Purpose: To investigate the feasibility of combining conventional high-dose-rate (HDR) brachytherapy with a concomitant complementary intensity-modulated radiotherapy (IMRT) boost for improved target coverage in cervical cancers. Methods and Materials: Six patients with cervical cancer underwent conventional HDR (C-HDR) treatment. Computed tomography (CT) and magnetic resonance imaging (MRI) scans were acquired with a CT/MRI-compatible applicator in place. The clinical target volumes (CTVs), defined as the gross target volume with a 3-mm margin and the uterus, were delineated on the CT scans, along with the organs at risk (OARs). The IMRT plans were optimized to generate dose distributions complementing those of C-HDR to cover the CTV while maintaining low doses to the OARs (IMRT-HDR). For comparison, dwell-weight optimized HDR (O-HDR) plans were also generated to cover the CTV and spare the OARs. The three treatment techniques (C-HDR, O-HDR, and IMRT-HDR) were compared. The percentage of volume receiving 95% of the prescription dose (V{sub 95}) was used to evaluate dose coverage to the CTV, and the minimal doses in the 2.0-cm{sup 3} volume receiving the greatest dose were calculated to compare the doses to the OARs. Results: The C-HDR technique provided very poor CTV coverage in 5 cases (V{sub 95} <62%). Although O-HDR provided excellent gross tumor volume coverage (V{sub 95} {>=}96.9%), it resulted in unacceptably high doses to the OARs in all 6 cases and unsatisfactory coverage to the whole CTV in 3 cases. IMRT-HDR not only yielded substantially improved CTV coverage (average V{sub 95} = 95.3%), but also kept the doses to the bladder and rectum reasonably low. Conclusion: Compared with C-HDR and O-HDR, concomitant IMRT boost complementary to C-HDR not only provided excellent CTV coverage, but also maintained reasonably low doses to the OARs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Toward Prostate Cancer Contouring Guidelines on Magnetic Resonance Imaging: Dominant Lesion Gross and Clinical Target Volume Coverage Via Accurate Histology Fusion

Purpose: Defining prostate cancer (PCa) lesion clinical target volumes (CTVs) for multiparametric magnetic resonance imaging (mpMRI) could support focal boosting or treatment to improve outcomes or lower morbidity, necessitating appropriate CTV margins for mpMRI-defined gross tumor volumes (GTVs). This study aimed to identify CTV margins yielding 95% coverage of PCa tumors for prospective cases with high likelihood. Methods and Materials: Twenty-five men with biopsy-confirmed clinical stage T1 or T2 PCa underwent pre-prostatectomy mpMRI, yielding T2-weighted, dynamic contrast-enhanced, and apparent diffusion coefficient images. Digitized whole-mount histology was contoured and registered to mpMRI scans (error ≤2 mm). Four observers contoured lesion GTVs on each mpMRI scan. CTVs were defined by isotropic and anisotropic expansion from these GTVs and from multiparametric (unioned) GTVs from 2 to 3 scans. Histologic coverage (proportions of tumor area on co-registered histology inside the CTV, measured for Gleason scores [GSs] ≥6 and ≥7) and prostate sparing (proportions of prostate volume outside the CTV) were measured. Nonparametric histologic-coverage prediction intervals defined minimal margins yielding 95% coverage for prospective cases with 78% to 92% likelihood. Results: On analysis of 72 true-positive tumor detections, 95% coverage margins were 9 to 11 mm (GS ≥ 6) and 8 to 10 mm (GS ≥ 7) for single-sequence GTVs and were 8 mm (GS ≥ 6) and 6 mm (GS ≥ 7) for 3-sequence GTVs, yielding CTVs that spared 47% to 81% of prostate tissue for the majority of tumors. Inclusion of T2-weighted contours increased sparing for multiparametric CTVs with 95% coverage margins for GS ≥6, and inclusion of dynamic contrast-enhanced contours increased sparing for GS ≥7. Anisotropic 95% coverage margins increased the sparing proportions to 71% to 86%. Conclusions: Multiparametric magnetic resonance imaging–defined GTVs expanded by appropriate margins may support focal boosting or treatment of PCa; however, these margins, accounting for interobserver and intertumoral variability, may preclude highly conformal CTVs. Multiparametric GTVs and anisotropic margins may reduce the required margins and improve prostate sparing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Methanol Partial Oxidation on Cu(111) and PtCu(111) Single-Atom Alloy Surfaces: Effect of Surface Oxygen Coverage on Selectivity

The selective oxidation of methanol to formaldehyde on Cu surfaces is an important and well-studied reaction. However, a systematic analysis of product selectivity as a function of oxygen coverage on Cu(111) and Cu-based single-atom alloys (SAAs) has not been previously reported. In this work, we present a comprehensive investigation of deuterated methanol (CD 3 OH) partial oxidation on Cu(111) and 1% PtCu(111) SAA surfaces as a function of preadsorbed oxygen coverage. Temperature-programmed desorption (TPD) and X-ray photoelectron spectroscopy (XPS) reveal that isolated Pt atoms inhibit the initial surface oxidation of Cu(111) under low oxygen exposures. Despite this difference in oxidation kinetics, the product selectivity remains largely unaffected: on both Cu(111) and PtCu(111), formaldehyde (CD 2 O) is the predominant partial oxidation product over a broad range of oxygen coverages. The selectivity toward formaldehyde peaks at intermediate oxygen coverages (∼0.3 monolayers, ML), indicating the existence of an optimal oxygen loading for partial oxidation. Notably, the similar product selectivities on Cu(111) and PtCu(111) over a range of surface oxygen coverage indicate that Pt single atoms do not significantly alter the reaction pathway or shift the optimal oxygen coverage for formaldehyde formation. Control experiments confirm that Cu(111) is unreactive toward methanol in the absence of oxygen, while PtCu(111) surfaces produce a small amount of formaldehyde even when oxygen is not preadsorbed, indicating that isolated Pt atoms facilitate O−H activation at below 150 K, leading to H 2 desorption, followed by C−D activation at higher temperatures (∼350 K). Density functional theory (DFT)-based calculations show that Pt atoms increase the O 2 dissociation barrier relative to Cu(111), consistent with the observed inhibition of oxidation at low exposures. Overall, this work provides the first detailed selectivity map for methanol oxidation on oxidized Cu(111) and PtCu(111) SAA surfaces. By linking classical mechanistic insights such as methoxy- and formate-mediated pathways with single-atom alloy catalyst design, this work demonstrates that while Pt substitution modulates the oxidation kinetics and oxygen binding, the overall selectivity toward formaldehyde is governed primarily by oxygen coverage. These findings underscore the potential of isolated dopants to tune surface oxidation behavior without compromising the intrinsic partial oxidation selectivity of copper-based catalysts.

36 MATERIALS SCIENCE↗

Effects of chlorine and oxygen coverage on the structure of the Au(111) surface

We investigate the effects of Cl and O coverage on the atomic structure of the Au(111) surface using density functional theory calculations. We find that the release and incorporation of gold atoms in the adsorbate layer becomes energetically favorable only at high coverages of either O or Cl (>0.66 ML (monolayer) for O and >0.33 ML for Cl), whereas adsorption without the incorporation of gold is favorable at lower coverages. The bonding between the adsorbate and gold substrate changes significantly with coverage, becoming more covalent (less ionic) at higher Cl and O coverage. This is based on the fact that at higher coverages there is less ionic charge transfer to the adsorbate, while the electron density in the region between the adsorbate and a surface gold atom is increased. Our results illustrate that the O and Cl coverage on Au(111) can dramatically affect its structure and bonding, which are important features in any application of gold involving these adsorbates.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SU-F-19A-12: Split-Ring Applicator with Interstitial Needle for Improved Volumetric Coverage in HDR Brachytherapy for Cervical Cancer

Purpose: To evaluate volumetric coverage of a Mick Radionuclear titanium Split-Ring applicator (SRA) with/without interstitial needle compared to an intracavitary Vienna applicator (VA), interstitial-intracavitary VA, and intracavitary ring and tandem applicator (RTA). Methods: A 57 year-old female with FIGO stage IIB cervical carcinoma was treated following chemoradiotherapy (45Gy pelvic and 5.4Gy parametrial boost) with highdose- rate (HDR) brachytherapy to 30Gy in 5 fractions using a SRA. A single interstitial needle was placed using the Ellis Interstitial Cap for the final three fractions to increase coverage of left-sided gross residual disease identified on 3T-MRI. High-risk (HR) clinical target volume (CTV) and intermediate-risk (IR) CTV were defined using axial T2-weighted 2D and 3D MRI sequences (Philips PET/MRI unit). Organs-at-risks (OARs) were delineated on CT. Oncentra planning system was used for treatment optimization satisfying GEC-ESTRO guidelines for target coverage and OAR constraints. Retrospectively, treatment plans (additional 20 plans) were simulated using intracavitary SRA (without needle), intracavitary VA (without needle), interstitial-intracavitary VA, and intracavitary RTA with this same patient case. Plans were optimized for each fraction to maintain coverage to HR-CTV. Results: Interstitial-intracavitary SRA achieved the following combined coverage for external radiation and brachytherapy (EQD2): D90 HR-CTV =94.6Gy; Bladder-2cc =88.9Gy; Rectum-2cc =65.1Gy; Sigmoid-2cc =48.9Gy; Left vaginal wall (VW) =103Gy, Right VW =99.2Gy. Interstitial-intracavitary VA was able to achieve identical D90 HR-CTV =94.6Gy, yet Bladder-2cc =91.9Gy (exceeding GEC-ESTRO recommendations of 2cc<90Gy) and Left VW =120.8Gy and Right VW =115.5Gy. Neither the SRA nor VA without interstitial needle could cover HR-CTV adequately without exceeding dose to Bladder-2cc. Conventional RTA was unable to achieve target coverage for the HR-CTV >80Gy without severely overdosing OARs. Conclusion: The Ellis Interstitial Cap for the SRA offered superior dosimetric coverage as compared to the interstitialintracavitary VA. This represents the first reported use for this devise, and further investigation is warranted.

60 APPLIED LIFE SCIENCES↗

SU-E-T-333: Dosimetric Impact of Rotational Error On the Target Coverage in IMPT Lung Cancer Plans

Purpose: The main purpose of this study was to investigate the impact of rotational (yaw, roll, and pitch) error on the planning target volume (PTV) coverage in lung cancer plans generated by intensity modulated proton therapy (IMPT). Methods: In this retrospective study, computed tomography (CT) dataset of previously treated lung case was used. IMPT plan were generated on the original CT dataset using left-lateral (LL) and posterior-anterior (PA) beams for a total dose of 74 Gy[RBE] with 2 Gy[RBE] per fraction. In order to investigate the dosimetric impact of rotational error, 12 new CT datasets were generated by re-sampling the original CT dataset for rotational (roll, yaw, and pitch) angles ranged from −5° to +5°, with an increment of 2.5°. A total of 12 new IMPT plans were generated based on the re-sampled CT datasets using beam parameters identical to the ones in the original IMPT plan. All treatment plans were generated in XiO treatment planning system. The PTV coverage (i.e., dose received by 95% of the PTV volume, D95) in new IMPT plans were then compared with the PTV coverage in the original IMPT plan. Results: Rotational errors caused the reduction in the PTV coverage in all 12 new IMPT plans when compared to the original IMPT lung plan. Specifically, the PTV coverage was reduced by 4.94% to 50.51% for yaw, by 4.04% to 23.74% for roll, and by 5.21% to 46.88% for pitch errors. Conclusion: Unacceptable dosimetric results were observed in new IMPT plans as the PTV coverage was reduced by up to 26.87% and 50.51% for rotational error of 2.5° and 5°, respectively. Further investigation is underway in evaluating the PTV coverage loss in the IMPT lung cancer plans for smaller rotational angle change.

60 APPLIED LIFE SCIENCES↗

A simplified framework for prediction of sensor network coverage in real-time structural health monitoring of plate-like structures

In this article, the coverage area prediction of piezoelectric sensor network for detecting a specific type of under-surface crack in plate-like structures is addressed. In particular, this article proposes a simplified framework to estimate the coverage of any given sensor network arrangement when a critical defect is known. Based on numerical results from finite element methods (FEM), a simplified framework to estimate coverage area of any given network arrangement is developed. Using such a simplified framework, one can avoid time-consuming procedure of evaluating numerous FEM models in estimating sensor network coverage. Back-scatter fields of partial cracks are estimated using a proposed function, whose parameters are estimated from the results of a limited number of FEM simulations. The proposed function efficiently predicts the back-scattered field of any combination of transmitters and receivers for a given crack geometry. Superposition is used to estimate the coverage area of an arbitrary piezoelectric (e.g., PZT) sensor network. It is shown that the coverage area of a sensor network depends on both sensor network geometry and defect properties (e.g., crack inclination) and it is not necessarily a linear function of the number of sensors. Furthermore, it is shown that the network arrangement has an important effect on the geometry of the coverage area. Experimental results of a network of 14 PZTs in two clusters confirm the accuracy of the method.

Engineering↗