Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cost and performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A Cost and Performance System (CAPS) in a Federal agency

Cost and Performance System (CAPS) is an automated system used from the planning phase through implementation to analysis and documentation. Data is retrievable or available for analysis of cost versus performance anomalies. CAPS provides a uniform system across intra- and international elements. A common system is recommended throughout an entire cost or profit center. Data can be easily accumulated and aggregated into higher levels of tracking and reporting of cost and performance.The level and quality of performance or productivity is indicated in the CAPS model and its process. The CAPS model provides the necessary decision information and insight to the principal investigator/project engineer for a successful project management experience. CAPS provides all levels of management with the appropriate detailed level of data.

Huseonia, W. F.↗

Natural fiber-derived gas diffusion layers for high performance, lower cost PEM fuel cells

The gas diffusion layer (GDL) is a critical component of proton exchange membrane fuel cells. GDL manufacture is dominated by the use of polyacrylonitrile (PAN) fibers, resulting in high production costs. Those costs contribute to the high cost of fuel cell stacks. Thus, reducing GDL manufacturing costs without sacrificing performance, should help reduce the overall cost of the fuel cell stack. Using inexpensive, natural fiber-based papers and fabric as substrates, here we examine the inherent performance these materials as GDLs, and the improvements enabled by the addition of a microporous layer, gas-phase hydrophobic treatment, and densification. The resulting GDLs achieve equivalent performance the commercial baseline GDL and demonstrate the potential of lower cost GDLs.

25 ENERGY STORAGE↗

Impacts of PV Module Connector Failures on Cost and Performance of Utility Scale Photovoltaic Systems

The reliability, cost and performance of electrical connectors are a concern in all types of electrical systems, and demands on connectors used on photovoltaic (PV) systems include that connectors maintain electrical conductivity and physical strength, endure ultraviolet sunlight and high ambient temperature, and resist moisture and chemical intrusion over a very long (>25 year) performance period. Connector failures increase operation and maintenance (O&M) costs and reduce plant production, but connector failure can also cause safety and liability problems, which are of greater concern. This work results from a three-year collaboration between Sandia National Laboratories (SNL), the Electric Power Research Institute (EPRI), and the National Renewable Energy Laboratory (NREL) and funded by the U.S. Department of Energy (DOE) Solar Energy Technology Office (SETO) under Agreements #39035 and #38531 "Connector Reliability Across the US Solar Sector." a multi-pronged investigation of PV connector health across the US (see https://energy.sandia.gov/pvconnectors/). This report presents derivation of a Techno-Economic Analysis (TEA) that models failure modes and frequencies (how often failure occurs), estimates O&M costs and lost production associated with connector failures, and then calculates the effect that PV module connectors can have on Levelized Cost of Energy (LCOE). The model is informed with initial data from quantitative assessment of failure rates, root causes and mechanisms, in-situ diagnostics and data collection, lab-based forensics, and interviews with PV connector manufacturers and plant operators. SNL conducted site inspections at multiple utility-scale sites in different climates and subjected field samples of new, used, and degraded connectors to visual and electrical characterization. EPRI conducted metallurgical analysis of the pin and sleeve conductors to study failure-induced morphological and compositional changes. There is in general a shortage of statistically valid data, but data from PVROM database maintained by SNL was sufficient to ascertain failure rates and lost production as well as provide qualitative insight in its curated maintenance records. This report details the structure of the mathematical model but the sources of data to inform the model will continue to evolve. Analysis of a 100 MW PV plant is provided as an example of the use of the model, with results indicating that connectors are responsible for Annualized O&M Costs of $\$$71,933/year; Annualized Unit O&M Costs of $\$$0.72/kW/year; that a Reserve Account of $\$$187,220 should be available to fund repairs related to connectors; that connectors add $\$$1,494,004 to the Net Present Value of the O&M Costs (project life); and that O&M related to connectors adds about $\$$0.00088/kWh to the Levelized Cost of Energy. The impact of this model is to provide a tool to make the US solar sector more robust by quantifying and monetizing the reliability risks to utility-scale PV systems posed by poorly installed, mismatched and/or poorly designed and manufactured connectors. The TEA provides a model incorporating failure statistics, O&M cost data, and lost production into a single figure of merit, informing decisions and enabling practitioners to optimize cost and performance trade-offs. Stakeholders include connector manufacturers, system designers and equipment specifiers, standards bodies, installers and O&M providers, investors and insurance underwriters. This report supports continued growth of PV predicated on assurances that properly installed and maintained PV system connectors are safe and reliable. The project team is proposing future work including accelerated testing of connectors and expanding the approach taken here to other PV system components, such as TEA for rapid shut-down devices.

14 SOLAR ENERGY↗

Optimization in the design of a 12 gigahertz low cost ground receiving system for broadcast satellites. Volume 1: System design, performance, and cost analysis

The technical and economical feasibility of using the 12 GHz band for broadcasting from satellites were examined. Among the assigned frequency bands for broadcast satellites, the 12 GHz band system offers the most channels. It also has the least interference on and from the terrestrial communication links. The system design and analysis are carried out on the basis of a decision analysis model. Technical difficulties in achieving low-cost 12 GHz ground receivers are solved by making use of a die cast aluminum packaging, a hybrid integrated circuit mixer, a cavity stabilized Gunn oscillator and other state-of-the-art microwave technologies for the receiver front-end. A working model was designed and tested, which used frequency modulation. A final design for the 2.6 GHz system ground receiver is also presented. The cost of the ground-terminal was analyzed and minimized for a given figure-of-merit (a ratio of receiving antenna gain to receiver system noise temperature). The results were used to analyze the performance and cost of the whole satellite system.

Ohkubo, K.↗

Cost and Performance Analysis for Five Existing Geothermal Heat Pump-Based District Energy Systems in the United States

District energy systems supplied by geothermal heat pumps (GHPs) have been deployed across the United States for both heating and cooling end uses. To better understand their performance and potential, the geothermal research team at the National Renewable Energy Laboratory analyzed cost and performance of five existing GHP-based district energy systems in the United States. The five systems selected are Ball State University in Indiana, Colorado Mesa University in Colorado, Miami University in Ohio, West Union in Iowa, and Whisper Valley in Texas. The necessary information, including district size, operation period, GHP performance, and costs, was collected through literature review and interviews. The survey results indicated the five systems studied consist of geothermal borehole field(s) and ground loop(s) connected to central loop. While the GHPs were in central plants at Ball State University and Miami University, the central loops at Colorado Mesa University, West Wood, and Whisper Valley were connected through service lines to individual heat pumps in each building. Our analysis indicates the systems have been operating reliably and cost-effectively and contributed to a reduction in carbon emissions.

15 GEOTHERMAL ENERGY↗

Battery Performance and Cost Model (BatPaC) Version 6.0

SF-26-016 The Battery Performance and Cost model (BatPaC) is a calculation method based on Microsoft Excel spreadsheets that has been developed at Argonne for estimating the performance and manufacturing cost of lithium-ion batteries for electric-drive vehicles including hybrid-electrics (HEV), plug-in hybrids (PHEVs) and pure electrics. BatPaC was first developed in 2007, was subsequently peer reviewed, and it has served Argonne researchers and the greater battery community in studying the impact of material properties on performance at the pack level. BatPaC has been updated and re-released multiple times since its original public release in 2011. This current version is BatPaC 6.0, which contains additional functionality needed to handle advances in automotive batteries, like the use of lithium metal and silicon anodes and the need to accommodate cell expansion and apply high levels of pressure.

KNEHR, KEVIN [Argonne National Laboratory (ANL), A↗

High CO2 Capture Rate Cost and Performance for F- and H-Class Natural Gas Combined Cycles (NGCC)

The National Energy Technology Laboratory (NETL) is updating its study titled “Cost and Performance Baselines for Fossil Energy Plants, Volume 1: Bituminous Coal and Natural Gas to Electricity.” Revision 4 was published in 2019. Pulverized coal (PC) and natural gas combined cycle (NGCC) cases with carbon capture in that study capture carbon dioxide (CO2) at 90% efficiency. Field-testing of post-combustion CO2 capture technology as well as vendor and industry feedback on projects currently in the planning stages (including FEED projects sponsored by DOE) indicate that capture rates as high as 95% are feasible for both coal- and natural gas-fueled electricity generating units. Technology suppliers (as reflected in vendor-supplied information provided to DOE for this study that included cost and performance estimates for both NGCC (97%) and PC (99%) study cases) as well as subject matter experts acknowledge and support that solvent-based post-combustion CO2 capture technologies are capable of achieving CO2 removal rates beyond 95% on low-purity streams representative of fossil-fueled combustion; however, the relatively limited experience with design and operation of capture systems that can routinely, reliably, and economically achieve very high removal rates (e.g., 97% for NGCC flue gas) requires further study. This presentation will address performance and cost estimates for 90%, 95%, and 97% capture for F- and H-class NGCC plants. This presentation was given at the 2022 Pittsburgh Coal Conference.

Fout, Timothy↗

Performance and cost of fuel cells for off-road heavy-duty vehicles

Hydrogen fuel cell-powered off-road vehicles can replace hydrocarbon-powered off-road vehicles to reduce carbon dioxide and criteria pollutant emissions in the agriculture, construction, and mining industries. Vehicle manufacturers and customers recognize health and environmental benefits of emissions reductions but are ultimately compelled by the total cost of ownership of their vehicles. In this study, we conduct a technoeconomic evaluation for three hallmark off-road vehicles, tractors, wheel loaders, and excavators, comparing vehicles with hydrogen fuel cell + battery hybrid powertrains to traditional diesel powertrains. Stakeholder-valued performance metrics include fuel cell engine power, engine durability, hydrogen consumption rate, hydrogen storage system volume, and energy-regenerative drivetrain efficiency. The total cost of ownership includes capital, operating and maintenance, fuel, and fuel storage costs. State-of-the-art fuel cell powered wheel loaders and excavators are currently cost competitive with diesel platforms. If targeted improvements to cost, performance, and durability improvements of fuel cell stacks and storage systems are achieved, fuel cell systems would be cost competitive for tractors and significantly lower total cost of ownership options for wheel loaders and excavators.

33 ADVANCED PROPULSION SYSTEMS↗

Updated Cost And Performance Results for Natural Gas Combined Cycles (NGCC)

Updated cost and performance results are presented by NETL for both F and H Class turbines, presented at the Clearwater Clean Energy Conference in August, 2022. Results are presented for cases with and without 90% CO2 Capture. Preliminary results for high capture rates presented as well.

Fout, Timothy↗

Development of Advanced Solid Sorbents for Direct Air Capture (Final Report)

RTI International is partnering with Creare, and Mohammed VI Polytechnic University (UM6P) successfully met all major technical objectives as outlined below: Identified one MOF adsorbent for DAC; Identified one amine-P-dendrimer adsorbent for DAC; Performed Computational fluid dynamics simulations of the MOF and amine-P-dendrimer adsorbents and validate them with experimental data; Selected one adsorbent for DAC; Demonstrated the scale-up of selected candidate and perform cost review; Performed a preliminary process design; Performed technology maturation plan and environmental health and safety risk assessment. After a thorough comparison between both adsorbents (MOFs and P-dendrimers) and based on their technical merits, the amine-based P-dendrimers sorbent was selected as the best performing adsorbent for DAC. In fact, the amine-based P-dendrimers have demonstrated superior performance over the MOF sorbents under relevant DAC conditions. The selected sorbent has been used in subsequent projects (DE-FE0032099 and DE-AR0001412) and has demonstrated similar superior performance with no loss of activity after long-term sorption-desorption testing (e.g., 100 cycles). This sorbent has demonstrated a very high and stable sorption performance, excellent kinetics, and fast regeneration at 80 °C, specifically at 75% relative humidity (RH). The incorporation of RTI’s high-performance, high-durability amine-based P-dendrimers sorbent and Creare’s hybrid additive manufacturing (H-AM) technology that will produce high performance, compact heat and mass exchange structures at low cost using methods, will lead to a contactor that is optimized for wind-driven operation. This contactor technology provides a technically viable pathway for reducing the cost of DAC to <$100/tonne of CO 2 .

36 MATERIALS SCIENCE↗

Energy Storage Cost and Performance Database

In support of the U.S. Department of Energy’s Energy Storage Grand Challenge, Pacific Northwest National Laboratory is applying its rich history of battery research and development to provide the U.S. Department of Energy (DOE) and industry with a guide to current energy storage costs and performance metrics for various technologies. Cost and performance metrics for individual technologies track the following to provide an overall cost of ownership for each technology: cost to procure, install, and connect an energy storage system; associated operational and maintenance costs; and end-of-life costs. These metrics are intended to support DOE and industry stakeholders in making sound decisions about future R&D directions and priorities that move the United States closer to its goal of energy independence. The technologies currently being evaluated are lithium-ion [lithium iron phosphate (LFP) and nickel manganese cobalt (NMC)] batteries, vanadium redox flow batteries, lead-acid batteries, zinc-based batteries, hydrogen energy storage, pumped storage hydropower, gravitational energy storage, compressed air energy storage, and thermal energy storage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Magnetic Gears for a Marine Hydrokinetic Generator Component Model

The goal of this project is to design, fabricate, and test a hermetically sealed 50 kilowatt (kW) multistage magnetically geared generator (MGG). The Component Content Model provides data submitters with an easy and consistent means of uploading data and associated meta data about a component that is currently under development. The data fields include generic information about the component, technology classifications, current costs and performance, proposed target goals, and the environment that the component is operated in. These data are important to DOE and will be used to develop data products that provide quantitative information to guide and support programmatic decisions. Data will also be used by DOE in general assessments of MHK component readiness, performance, costs, and proposed plans. The ultimate goal is to use these data to perform research and tailor programs to best benefit the industry.

16 TIDAL AND WAVE POWER↗

Cost and Performance Projections for Coal- and Natural Gas-Fired Power Plants

This report provides quantitative estimates of future cost and performance improvements for fossil-fueled power plants equipped with carbon capture developed through the adaption/modification of relevant Aspen Plus ® case study models from published NETL techno-economic analyses. The cost and performance estimates in this report are meant to represent prospective improvements that may be realized for low-carbon-emitting PC and NGCC power plants through robust commercial deployment (e.g., learning by doing) of high TRL technologies as well as additional investments in targeted RD&D activities. The methodology used to develop the estimates in this report is intended to allow direct comparison of the technology improvements with the SOA baseline published in NETL’s Fossil Energy Baseline (Rev 4a) Report.

20 FOSSIL-FUELED POWER PLANTS↗

Cost and Performance Estimates for State-of-the-Art and Advanced 1×1 H-Class Natural Gas-Fired Power Plants

As an extension of NETL's Fossil Energy Baseline for Electricity Generating Units Volume 1: Coal and Natural Gas to Electricity (FEB Rev 4a, this study develops cost and performance estimates for analogous NGCC cases using a state-of-the-art 2023 vintage H-Class CT in a 1×1 configuration, where a single combustion turbine and heat recovery steam generator are coupled to a single steam turbine on a common shaft. These 1×1 H-Class cases are used to develop cost and performance estimates of X-Class 1×1 NGCC cases with advanced performance characteristics, analogous to NETL’s cost and performance projections report.

20 FOSSIL-FUELED POWER PLANTS↗

Examination of Factors Affecting the Cost and Performance of a Natural Gas Combined Cycle Equipped with Carbon Dioxide Capture

The purpose of this Technical Note is to report the findings of an examination of the effect of plausible deviations in select study assumptions on the reported cost and performance estimates for a power plant case drawn from NETL’s “Cost and Performance Baseline for Fossil Energy Plants Volume 1: Bituminous Coal and Natural Gas to Electricity” (known as the Fossil Energy Baseline). An F-Class NGCC power plant equipped with state-of-the-art, solvent-based, post-combustion carbon dioxide (CO2) capture (95 percent carbon capture rate)—designated as Case B31B.95—was selected for this work. This sensitivity analysis provides insight into the effects of parameter variations within and across selected categories—ambient conditions, construction cost, natural gas (NG) price, capacity factor, and finance—on the plant performance and capital and operating and maintenance (O&M) costs, and the subsequent impact on common figures of merit.

20 FOSSIL-FUELED POWER PLANTS↗