Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cost analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Generator Interconnection Cost Analysis in the Southwest Power Pool (SPP) Territory

Electric transmission system operators (ISOs, RTOs, or utilities) require new large generators seeking to connect to the grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. Berkeley Lab has collected interconnection cost data for 845 projects from interconnection studies for the Southwest Power Pool (SPP) Territory. The studies were performed between 2002 and 2023 and include all of the most refined cost estimates available. Project-level cost summary data are available for download on this page. We find: -Project-specific interconnection costs can differ widely. -Average interconnection costs are stable for projects that complete all interconnection studies but have escalated for those that withdraw. -Broader network upgrade costs are the primary driver of recent cost increases, especially for withdrawn projects. -Potential interconnection costs of all solar and wind requests have been greater than those of storage and natural gas projects. -Economies of scale exist for completed wind and solar projects but not for other fuel types or withdrawn projects. -Interconnection costs vary by location. Berkeley Lab publishes a series of short analytical papers of generator interconnection costs to the transmission system for MISO, PJM, SPP, ISO-NE and NYISO, which you can find at https://emp.lbl.gov/interconnection_costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Generator Interconnection Cost Analysis in the Midcontinent Independent System Operator (MISO) territory

Electric transmission system operators (ISOs, RTOs, or utilities) require new large generators seeking to connect to the grid to undergo a series of impact studies before they can be built. This process establishes what new transmission equipment or upgrades may be needed before a project can connect to the system and assigns the costs of that equipment. Berkeley Lab has collected interconnection cost data from interconnection studies for the Midcontinent Independent System Operator (MISO), representing nearly 50% of all projects requesting interconnection from 2010 to 2020. Project-level cost summary data are available for download on this page. We find: -Average interconnection costs have grown as the number of interconnection requests have escalated -Projects that have completed all required interconnection studies have the lowest cost compared to applicants still actively working through the interconnection process or those that have withdrawn. -Broader network upgrade costs are the primary driver of recent cost increase. -Potential interconnection costs for wind, storage, and solar are larger than for natural gas -Larger generators have greater interconnection costs in absolute terms, but economies of scale exist on a per kW basis. -Interconnection costs vary by location Berkeley Lab will publish a series of short analytical papers of generator interconnection costs to the transmission system for MISO, PJM, SPP, ISO-NE and NYISO, which you can find at https://emp.lbl.gov/interconnection_costs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cost Analysis of Annual and Monthly Net Zero Energy Performance for Multifamily Buildings in the United States

As the United States continues its progress toward sustainable construction, net zero building design is becoming an increasingly important and popular topic. Two definitions of net zero energy performance, monthly and annual, provide different levels of energy autonomy and efficiency within a building. This article analyzes the viability and incremental cost for two-, three-, and four-story multifamily apartment buildings to reach both annual and monthly net zero energy performance throughout four climate zones in the United States using baseline reference buildings that represent current construction practices. Building size plays a large role in determining the capability for a building model to reach annual or monthly net zero. Two-story buildings are capable of reaching annual net zero with an increase in construction cost of about 4.4–5.6%. Three-story buildings in warmer climates can achieve annual net zero with an increase of about 5.1%, but models in colder climates cannot reach annual net zero performance. Four-story buildings cannot achieve net zero, owing to insufficient building area for solar arrays to produce electricity. Monthly net zero energy performance was significantly harder to achieve, with the only case reaching this goal being the two-story Houston based model, at an added cost of 8.2%. Generally speaking, only small buildings in warm climates will be able to achieve monthly net zero without vastly oversizing photovoltaic systems and increasing costs without adequate payback.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Baseline Cost Analysis of Energy Wastewater Treatment with Preliminary Feasibility Analysis of Critical Mineral Recovery

Critical mineral recovery from wastewater is an enhancement of conventional mining that can help meet growing demand. This work investigates two energy wastewaters that have previously been shown to be enriched in critical minerals, oil and gas produced water in the Permian Basin and combustion residual leachate. Treatment of these two wastewaters using reverse osmosis or thermal-based methods concentrates critical minerals, which improves the economic viability of critical mineral recovery. Revenue from mineral recovery could also offset treatment costs for operators. This work evaluates the cost of treatment for each wastewater and evaluates the potential revenue from critical minerals concentrated in the brine. The levelized cost of water for combustion residual leachate ranges from USD 1.90 to USD 16.20 (USD 2023/m 3 permeate) and for produced water ranges from USD 14.40 to USD 24.30 (USD 2023/m 3 distillate). Recovery opportunities range from USD 0.11 to USD 1.13 (USD 2023/m 3 permeate) for leachate and from USD 8.28 to USD 42.10 (USD 2023/m 3 distillate) for produced water, dominated by the value of magnesium and lithium. Comparing the maximum value of critical minerals contained in produced water and the maximum treatment costs, the value of critical minerals exceeds the cost of treatment by USD 17.80/m 3 distillate, which signals a potential revenue opportunity.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Energy Cost Analysis and Operational Range Prediction Based on Medium- and Heavy-Duty Electric Vehicle Real-World Deployments across the United States

While the market for medium- and heavy-duty battery-electric vehicles (MHD EVs) is still nascent, a growing number of these vehicles are being deployed across the U.S. This study used over 2.3 million miles of operational data from multiple types of MHD EVs across various regions and operating conditions to address knowledge gaps in total cost of ownership and operational range. First, real-world energy cost savings were determined: MHD fleets should experience energy cost savings each year from 2021 to 2035, regardless of vehicle platform, with the greatest savings seen in transit buses (up to USD 4459 annually) and HD trucks (up to USD 3284 annually). Second, to help fleets across various geographies throughout the U.S. assess the suitability of EVs for their year-round operating needs, operational range was modeled using the XGBoost algorithm (R2: 70%) given 22 input features relevant to vehicle efficiency. Finally, this paper recommends (1) that MHD fleets apply energy-saving practices to minimize the impacts of cold temperatures and high congestion levels on vehicle efficiency and range, and (2) that local hauling fleets select trucks with a nominal range nearly double the expected maximum daily range to account for range losses under local, urban driving conditions.

Qiu, Yin (ORCID:0009000900948794)↗

Integration of cryogenic energy storage with renewables and power plants: Optimal strategies and cost analysis

Energy storage is critical for overcoming challenges associated with the intermittency and the variable availability of renewable sources for decarbonizing the energy sector. Cryogenic energy storage (CES) is of interest due to its high technology readiness level, no geographical limitations, and moderate round-trip efficiency. The time-varying nature of demands and renewable availability needs to be considered at the design and integration stages of energy storage. We develop a mixed-integer nonlinear program (MINLP) model to obtain the energy storage costs on a daily basis for different scenarios that typically arise over an entire year. Using this optimization-based framework, we address key decision-making questions towards energy transition: What is the energy cost when CES is integrated with renewables and power plants? How does each scenario affect the overall energy cost? How much storage is needed for complete transition to renewables? What is the optimal integration towards 100% renewable energy? What are the optimal storage designs for both renewables and fossil-based power generation with current and future energy demands? Here, we discuss different scenarios and solutions to these questions.

25 ENERGY STORAGE↗

Comparative and Cost Analysis of a Novel Predictive Power Ramp Rate Control Method: A Case Study in a PV Power Plant in Puerto Rico

One of the most important aspects that need to be addressed to increase solar energy penetration is the power ramp-rate control. In weak grids such as the one found in Puerto Rico, it is important to smooth power fluctuations caused by the intermittence of passing clouds. In this work, a novel power ramp-rate control strategy is proposed. Additionally, a comparison with some of the most common power ramp-rate control methods is performed using a proposed model and real solar radiation data from the Coto Laurel photovoltaic power plant located in Ponce, Puerto Rico. The proposed model was validated using one-year real data from Coto Laurel. The power ramp-rate control methods were compared in real-time simulations using the OP5700 from Opal-RT Technologies considering power ramp rate fluctuations, power ramp-rate violations, fluctuations in the state-of-charge, among other indicators. Moreover, the proposed power ramp-rate control strategy, called predictive dynamic smoothing was explained and compared. Results indicate that the predictive dynamic smoothing produced a considerably reduced Levelized Cost of Storage compared to other power ramp-rate control methods and provided a higher lifetime expectancy for lithium batteries.

36 MATERIALS SCIENCE↗

Production of Uranium from Seawater Using a Novel Polymer Adsorbent – Process Development and Cost Analysis (Final Scientific/Technical Report SBIR Phase II)

Research in developing techniques for extracting uranium from seawater is of considerable current interest. One reason which drives scientists to develop techniques of sequestering uranium from ocean is the prediction that the land-based uranium reserves would be depleted by the end of this century based on the current production rate. Uranium exists in seawater at a very low concentration (about 3 ppb) and as highly stable uranyl tris-carbonato complexes, primarily in the form Ca 2 [UO 2 (CO 3 ) 3 ]. Because of the enormous volume of seawater, the total amount of uranium in ocean is estimated to be a thousand times greater than the land-based uranium resources. As early as 1964, the idea of extracting uranium from seawater was discussed by Davies et al. in a Nature paper. In the past decades, many different materials were tested to evaluate their ability for sequestering uranium from seawater. Among them, amidoxime and carboxylate containing polymer fiber adsorbents appear most promising because of their high uranium adsorption capacity and stability in seawater. The carboxylate groups are necessary to make the polymer adsorbent hydrophilic whereas the amidoxime groups provide strong coordination sites for uranyl ions. Moreover, according to theoretical analysis, the adsorbability of uranium may involve synergistic effects of both amidoxime and carboxyl groups in the fiber adsorbent.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal battery cost scaling analysis: minimizing the cost per kW h

Thermal and cost-scaling analyses provide the tools to optimize the geometry of thermal batteries based on cost. Figures-of-merit comprised of storage material properties are derived as the quantities that should be maximized when different components dominate cost.

25 ENERGY STORAGE↗

Cost-Benefit Analysis of Grid-Supportive Loads for Fast Frequency Response

Flexibility in inverter-based loads could be used to support the converter-dominated power grid by offering a rapid, autonomous, and adjustable power reserve during system transients to help maintain system stability. Based on technical potential, ancillary service (AS) value, and implementation costs, this study illustrates the cost-benefit analysis of grid-supportive loads (GSLs) for the supply of fast frequency response (FFR). The net benefit for each GSL is demonstrated using a case study and relevant data sources. The findings suggest that implementation costs for enabling GSL features are low compared to the value that grid operators get from the acquisition of responsive reserve services. The authors believe that, given the rising popularity of renewable energy sources, GSLs can be a useful tool for grid stability in low-inertia systems.

cost-benefit analysis↗

Cost-Benefit Analysis For Indonesia Building Sector: Whole-Building Cooling Solutions

The Net Zero World (NZW) Initiative Collaborative Work Program with the Government of Indonesia (GoI) includes technical assistance and investment mobilization facilitation to accelerate deployment of energy efficiency technologies and solutions for the building sector. A February 2023 U.S.–Indonesia Joint Workshop on Decarbonizing the Building Sector yielded a NZW Indonesia Building Decarbonization Working Group (NZW IBDWG) with four sub-working groups (SWG): SWG-A National Center, SWG-B Capacity Building, SWG-C Investment and Financing, and SWG-D Pilot Projects. Technical analysis of whole-building cooling solutions for tropical climates of Indonesia was conducted by SWG-A to quantify energy savings, carbon dioxide reductions, and comfort improvements offered by 12 passive or low-energy cooling strategies: ceiling fans with and without thermostat setbacks; cool roofs; cool walls; exterior awnings; exterior shades; interior shades; insulated roofs; insulated walls; low-e windows; solar window films; and natural ventilation. Leveraging the results from SWG-A, cost-benefit analysis (CBA) was conducted by SWG-C to assess the consumer and national costs and impacts associated with these 12 cooling solutions. The evaluation involved estimating life-cycle costs (LCC), payback period (PBP), net present values (NPV), annual electricity burden change for low-income households, and reduced national annual power-sector generation demand by 2030, 2040, 2050, and 2060. This evaluation can help guide Indonesia’s Just Energy Transition Partnership (JETP) investments in policies and programs to advance research, development, deployment, and commercial adoption (RDDCA) of efficient residential building sector cooling technologies and solutions in Indonesia. Four key energy conservation measures (ECM) have been identified to reduce air-conditioning (AC) energy demand in single-family housing in Indonesia: ceiling fan with temperature setback (to 28.1 °Celcius from 25 °C); insulated walls; insulated roof; and cool roof. This study found that low-income households with AC installations in Indonesia currently face a high energy cost burden of approximately 10%. However, by implementing a ceiling fan with temperature setback, this burden could decrease to 2.5% today and further reduce to 1.3% by the year 2060. The PBP for a ceiling fan with temperature setback is one year, indicating one of the lowest LCC and best NPV. In the planned upcoming phase of CBA, a series of building cooling improvement scenarios can be further defined, incorporating more than one ECM in combination with socio-economic factors evaluated in the initial CBA phase. Additionally, the analysis of ECM effects in multifamily housing can be expanded. This broader national analysis aims to encompass a holistic and comprehensive system-level perspective, including factors such as avoided power sector infrastructure investments, domestic job creation, domestic manufacturing job creation, and gross domestic product (GDP) growth.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Application and Interpretation of Acumen Risk ® Schedule and Cost Risk Analysis

Schedule risk and cost risk analyses use statistical techniques to predict a level of confidence in meeting a program’s completion date and cost. This paper describes how to interpret key Schedule Risk Analysis (SRA) and Cost Risk Analysis (CRA) results to determine the likelihood that the program completion dates are met, how much management reserve (MR) is needed to provide the acceptable certainty of completion by a specific date, and the risks and activities that are most likely to delay or add cost to a project. The combined process is often called a Schedule/Cost Uncertainty and Risk Analysis or “SCURA.”

29 ENERGY PLANNING, POLICY, AND ECONOMY↗