Engineering PapersSearch

SEARCH · Engineering Papers

Results for “correlation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Pressure correlations at a fluid/structure interface

The structure of pressure-pressure correlations at the interface of an incompressible steady-state turbulent flow with a rigid boundary was investigated. For the sake of completeness, the absolute value of the correlation between two random varying functions is herein defined as a number greater than or equal to zero and less than or equal to unity which is a measure of that fraction of one of the functions that 'follows' the second function (or vice versa). It was found that the soughtafter correlations can be determined by consideration of the high Re Navier-Stokes equation, but that the complexity of boundary layer turbulence, in particular the inhomogeneity perpendicular to the boundary and the anisotropy due to convective flow gradients, makes the structure of said correlations extremely difficult to assess. One of the earlier researchers in this field described the quantity under present consideration as 'a quantity which is beyond assessment.' Nonetheless, it was found that under some rather simplifying assumptions the determination of the required structure necessitates the formulation of the related structure of second order two-point correlations of turbulent velocity gradients, as well as third order two-point correlations of velocity gradients. The presence of these latter gradients is due to the nonlinearity in the turbulence ('turbulence self-interaction'). Both of these correlations are scaled, although not similarly, by factors dependent upon the magnitude of the convective flow, which can be modeled using a log law approximation. Fourth order correlations, although present, can be ignored, since they constitute 'higher order terms.' In a slightly more complex situation, it was found that convective flow gradients also have to be incorporated. At the moment, no definitive algebraic information peculiar to pressure-pressure correlations is available in the most highly idealized cases.

Trevino, George

The Impact of Anisotropic Error Correlation Modelling

Most data assimilation systems assume isotropic forecast error correlations, but results from two dimensional Kalman Filter experiments indicate that the correlations can be far from isotropic. In this paper we use a simple two-dimensional data assimilation system, which analyses trace chemical species such as ozone, to assess different approaches to modelling the error correlations. We compare assimilation results using isotropic correlations with results obtained using different approaches to modelling anisotropic correlations: first, using correlations based on the concentrations of the trace chemicals, and secondly using an advective correlation model. We show that these relatively cheap ways of modelling anisotropic correlations give objectively better results than using isotropic correlations. We discuss the possible extension of these approaches to a full 3-D meteorological data assimilation system.

Swinbank, R.

Quantifying the Correlation Between Eye-Movement and Perceptual Responses to Moving Plaids

To determine the extent to which the pursuit eye-movement and perceptual systems share a common neural motion-processing pathway, we simultaneously measure the psychophysical and eye-movement responses to drifting plaids in a direction-discrimination task. Correlation between the noise in the eye movements and percepts would suggest a shared neural substrate. Three observers were asked to track a plaid (Type I 90 deg; TF = 4 Hz, SF = 0.6 c/d; direction = -2, 0, or 2 deg), and to respond whether the motion was to the right or left of vertical. The eye-movement direction is computed from the initial 300 ms of saccade-free tracking (near open-loop). On each trial, we use the eye-movement direction to predict the perceptual response. We then compute the probability of successfully predicting the observer's response. We also use SOC analysis as an alternate measure of the correlation. We compare the data from both these analyses to the predictions of two models in which the eye movements and the percept are driven by either a common noisy signal (correlated model) or by two separate noisy signals (uncorrelated model). We also allow for the fact that our measured eye movements are degraded by eye-tracker noise. This noise causes our measured correlation to be lower than the actual biological correlation. The correlations in our data are higher than those predicted by the uncorrelated model, and are similar to the predictions of the correlated model. The proportion of perceptual responses correctly predicted by the eye movements were 0.66, 0.60, 0.73 for the -2, 0, 2 deg stimuli respectively (correlated model 0.65, 0.60, 0.70; uncorrelated model 0.58, 0.51, 0.60).The SOC proportions were 0.71, 0.64, 0.72 (correlated model 0.66, 0.64, 0.69; uncorrelated model 0.5, 0.5, 0.5). These results show that the oculomotor and perceptual system share a performance-limiting noise source and provide strong evidence that a common neural mechanism (perhaps MT or MST) drives both perception and smooth eye movements.

Beutter, Brent R.

On the Computation of Space-Time Correlations by Large-Eddy Simulation

Numerical comparisons in decaying isotropic turbulence suggest that there exist discrepancies in time correlations evaluated by DNS and LES using eddy-viscosity-type SGS models. This is consistent with the previous observations in forced isotropic turbulence. Therefore, forcing is not the main cause of the discrepancies. Comparisons among different SGS models in the LES also indicate that the model choice affects the time correlations in the LES. The multi-scale LES method using the dynamic Smagorinsky model on the small scale equation is the most accurate of the all models, the classic Smagorinsky model is the least accurate and the dynamic Smagorinsky model and spectral eddy viscosity model give intermediate results with small differences. The generalized sweeping hypothesis implies that time correlations in decaying isotropic turbulence are mainly determined by the instantaneous energy spectra and sweeping velocities. The analysis based on the sweeping hypothesis explains the discrepancies in our numerical simulations: the LES overpredicts the decorrelation time scales because the sweeping velocities are smaller than the DNS values, and underpredicts the magnitudes of time correlations because the energy spectrum levels are lower than the DNS ones. Since the sweeping velocity is determined by the energy spectra, one concludes that an accurate prediction of the instantaneous energy spectra guarantees the accuracy of time correlations. An analytical expression of sound power spectra based on Lighthill's theory and the quasi-normal closure assumption suggests that the sound power spectra are sensitive to errors in time correlations. Small errors in time correlations can cause significant errors in the sound power spectra, which exhibit a sizable drop at moderate to high frequencies accompanied by a shift of the peaks to lower frequencies. Based on the above analysis, two possible ways to improve the acoustic power spectrum predictions can be considered. The first is to construct better SGS models to improve the LES accuracy for time correlations. The second is to remedy the temporal statistics of the Lighthill stress tensor in order to "recover" the contribution from the unresolved scales in LES to time correlations.

He, Guo-Wei

Determination of Black Hole Mass in Cyg X-1 by Scaling of Spectral Index-QPO Frequency Correlation

It is well established that timing and spectral properties of Galactic Black Hole (BH) X-ray binaries (XRB) are strongly correlated. In particular, it has been shown that low frequency Quasi-Periodic Oscillation (QPO) nu(sub low) - photon index GAMMA correlation curves have a specific pattern. In a number of the sources studied the shape of the index-low frequency QPO correlations are self-similar with a position offset in the nu(sub low) - GAMMA plane determined by a BH mass M(sub BH). Specifically, Titarchuk & Fiorito (2004) gave strong theoretical and observational arguments that the QPO frequency values in this nu(sub low) - GAMMA correlation should be inversely proportional to M(sub BH). A simple translation of the correlation for a given source along frequency axis leads to the observed correlation for another source. As a result of this translation one can obtain a scaling factor which is simply a BH mass ratio for these particular sources. This property of the correlations offers a fundamentally new method for BH mass determination in XRBs. Here we use the observed QPO-index correlations observed in three BH sources: GRO J1655-40, GRS 1915+105 and Cyg X-1. The BH mass of (6.3 plus or minus 0.5) solar mass in GRO J1655-40 is obtained using optical observations. RXTE observations during the recent 2005 outburst yielded sufficient data to establish the correlation pattern during both rise and decay of the event. We use GRO J1655-40 as a standard reference source to measure the BH mass in Cyg X-1. We also revisit the GRS 1915+105 data as a further test of our scaling method. We obtain the BH mass in Cyg X-1 in the range 7.6-9.9.

Shaposhnikov, Nickolai

Ultralow-Power Digital Correlator for Microwave Polarimetry

A recently developed high-speed digital correlator is especially well suited for processing readings of a passive microwave polarimeter. This circuit computes the autocorrelations of, and the cross-correlations among, data in four digital input streams representing samples of in-phase (I) and quadrature (Q) components of two intermediate-frequency (IF) signals, denoted A and B, that are generated in heterodyne reception of two microwave signals. The IF signals arriving at the correlator input terminals have been digitized to three levels (-1,0,1) at a sampling rate up to 500 MHz. Two bits (representing sign and magnitude) are needed to represent the instantaneous datum in each input channel; hence, eight bits are needed to represent the four input signals during any given cycle of the sampling clock. The accumulation (integration) time for the correlation is programmable in increments of 2(exp 8) cycles of the sampling clock, up to a maximum of 2(exp 24) cycles. The basic functionality of the correlator is embodied in 16 correlation slices, each of which contains identical logic circuits and counters (see figure). The first stage of each correlation slice is a logic gate that computes one of the desired correlations (for example, the autocorrelation of the I component of A or the negative of the cross-correlation of the I component of A and the Q component of B). The sampling of the output of the logic gate output is controlled by the sampling-clock signal, and an 8-bit counter increments in every clock cycle when the logic gate generates output. The most significant bit of the 8-bit counter is sampled by a 16-bit counter with a clock signal at 2(exp 8) the frequency of the sampling clock. The 16-bit counter is incremented every time the 8-bit counter rolls over.

Piepmeier, Jeffrey R.

Using Correlated Photons to Suppress Background Noise

A proposed method of suppressing the effect of background noise in an optical communication system would exploit the transmission and reception of correlated photons at the receiver. The method would not afford any advantage in a system in which performance is limited by shot noise. However, if the performance of the system is limited by background noise (e.g., sunlight in the case of a free-space optical communication system or incoherently scattered in-band photons in the case of a fiber-optic communication system), then the proposed method could offer an advantage: the proposed method would make it possible to achieve a signal-to-noise ratio (S/N) significantly greater than that of an otherwise equivalent background- noise-limited optical communication system based on the classical transmission and reception of uncorrelated photons. The figure schematically depicts a classical optical-communication system and a system according to the proposed method. In the classical system, a modulated laser beam is transmitted along an optical path to a receiver, the optics of which include a narrow-band-pass filter that suppresses some of the background noise. A photodetector in the receiver detects the laser-beam and background photons, most or all of which are uncorrelated. In the proposed system, correlated photons would be generated at the transmitter by making a modulated laser beam pass through a nonlinear parametric down-conversion crystal. The sum of frequencies of the correlated photons in each pair would equal the frequency of the incident photon from which they were generated. As in the classical system, the correlated photons would travel along an optical path to a receiver, where they would be band-pass filtered and detected. Unlike in the classical system, the photodetector in the receiver in this system would be one that intrinsically favors the detection of pairs of correlated photons over the detection of uncorrelated photons. Even though there would be no way of knowing the precise location and time of creation of a given pair of correlated signal photons in the nonlinear down-conversion crystal, the fact that the photons are necessarily created at the same time and place makes it possible to utilize conventional geometrical imaging optics to reunite the photons in coincidence in the receiving photodetector. Because most or all of the signal photons would be correlated while most or all of the noise photons would be uncorrelated, the S/N would be correspondingly enhanced in the photodetector output. An additional advantage to be gained by use of a correlated-photon detector is that it could be capable of recovering the signal even in the presence of background light so bright that a classical uncorrelated-photon detector would be saturated. A blocked-impurity-band (BIB) photodetector that preferentially detects pairs of correlated photons over uncorrelated ones and that operates at a quantum efficiency of 88 percent is commercially available. This detector must be cooled to the temperature of liquid helium to obtain the desired low-noise performance. It is planned to use this detector in a proof-of-principle demonstration. In addition, it may be possible to develop GaN-based photodetectors that could offer the desired low-noise performance at room temperature.

Jackson, Deborah

Mark 3 correlator hardware and software

The Mark 3 correlator system is described in some detail. The correlator system is based on a modular philosophy. Each correlator module independently processes the data from one track pair. Therefore, 28 modules are necessary to complete a full one baseline processor and 84 modules for a full 3 baseline processor. Each correlator module has two interfaces: (1) data and clock from each of the two tracks to be correlated and (2) Computer Automated Measurement and Control (CAMAC) dataway interface to the computer. The processor is organized around the IEEE CAMAC standard architecture, housing 15 correlator modules in each of 6 crates. This allows one pass processing of a full 3 baseline 28 track observation or a 6 baseline (4 station) 14 track observation. The correlator architecture allows easy expansion for up to 8 stations. The computer system is an HP 1000 system utilizing a 16 bit minicomputer with disc and tape peripherals. The processing software is also organized in a modular fashion with many independent but cooperative programs controlling the operation of the Mark 3 processor. Processing time through the correlator is normally real time or faster, with graphics displays providing real time monitor and control of the processing operation.

Whitney, A. R.

Pipelined digital SAR azimuth correlator using hybrid FFT-transversal filter

A synthetic aperture radar system (SAR) having a range correlator is provided with a hybrid azimuth correlator which utilizes a block-pipe-lined fast Fourier transform (FFT). The correlator has a predetermined FFT transform size with delay elements for delaying SAR range correlated data so as to embed in the Fourier transform operation a corner-turning function as the range correlated SAR data is converted from the time domain to a frequency domain. The azimuth correlator is comprised of a transversal filter to receive the SAR data in the frequency domain, a generator for range migration compensation and azimuth reference functions, and an azimuth reference multiplier for correlation of the SAR data. Following the transversal filter is a block-pipelined inverse FFT used to restore azimuth correlated data in the frequency domain to the time domain for imaging.

Wu, C.

Response time correlations for platinum resistance thermometers in flowing fluids

The thermal response of two types of Platinum Resistance Thermometers (PRT's), which are being considered for use in the National Transonic Wind Tunnel Facility, were studied. Response time correlations for each PRT, in flowing water, oil and air, were established separately. A universal correlation, tau WOA = 2.0 + 1264, 9/h, for a Hy-Cal Sensor (with a reference resistance of 100 ohm) within an error of 20% was established while the universal correlation for the Rosemount Sensor (with a reference resistance of 1000 ohm), tau OA = 0.122 + 1105.6/h, was found with a maximum percentage error of 30%. The correlation for the Rosemount Sensor was based on air and oil data only which is certainly not sufficient to make a correlation applicable to every condition. Therefore, the correlation needs more data to be gathered in different fluids. Also, it is necessary to state that the calculation of the parameter, h, was based on the available heat transfer correlations, whose accuracies are already reported in literature uncertain within 20-30%. Therefore, the universal response constant correlations established here for the Hy-Cal and Rosemount sensors are consistent with the uncertainty in the input data and are recommended for future use in flowing liquids and gases.

Pandey, D. K.

A correlational analysis of the effects of changing environmental conditions on the NR atomic hydrogen maser

An extensive statistical analysis has been undertaken to determine if a correlation exists between changes in an NR atomic hydrogen muser's frequency offset and changes in environmental conditions. Data have been acquired over the past 20 months by recording the frequency offset of three NR atomic hydrogen masers along with the relative and absolute humidity, barometric pressure, and ambient temperature of the laboratory in which the masers are maintained. Correlational analyses have been performed comparing barometric pressure, humidity, and temperature with maser frequency offset as functions of time for periods ranging from 5.5 to 17 days. Semi partial correlation coefficients as large as -0.9 have been fond between barometric pressure and maser frequency offset for data covering periods as long as a week. Maser frequency offset and barometric pressure were consistently found to change simultaneously. The correlation between humidity and frequency offset is less predictable, and the resulting semi partial correlation coefficients were usually small when compared with those derived from the relationship between pressure and frequency offset. The time delay between changes in humidity and correlated changes in maser frequency offset was found to vary extensively with no predictable pattern. Analysis of temperature data indicates that, in the most current design, temperature does not significant(y affect maser frequency offset in the laboratory environment. Thus, the results of the analyses disclose a significant statistical correlation between changes in maser frequency offset and changes in barometric pressure. The statistics also reveal some correlation between humidity and frequency offset, bat for reasons to be discussed, the effects of humidity should be considered secondary to the effects of changing barometric pressure.

R. A. Dragonette

Cross-correlation between the 170 GHz survey map and the COBE differential microwave radiometer first-year maps

This letter describes results of a cross-correlation between the 170 GHz partial-sky survey, made with a 3.8 deg beam balloon-borne instrument, and the COBE DMR 'Fit Technique' reduced galaxy all-sky map with a beam of 7 deg. The strong correlation between the data sets implies that the observed structure is consistent with thermal variations in a 2.7 K emitter. A chi-square analysis applied to the correlation function rules out the assumption that there is no structure in either of the two maps. A second test shows that if the DMR map has structure but the 170 GHz map does not, the probability of obtaining the observed correlation is small. Further analyses support the assumption that both maps have structure and that the 170 GHz-DMR cross-correlation is consistent with the analogous DMR correlation function. Maps containing various combinations of noise and Harrison-Zel'dovich power spectra are simulated and correlated to reinforce the result. The correlation provides compelling evidence that both instruments have observed fluctuations consistent with anisotropies in the cosmic microwave background.

Ganga, Ken

The VLBA correlator: Real-time in the distributed era

The correlator is the signal processing engine of the Very Long Baseline Array (VLBA). Radio signals are recorded on special wideband (128 Mb/s) digital recorders at the 10 telescopes, with sampling times controlled by hydrogen maser clocks. The magnetic tapes are shipped to the Array Operations Center in Socorro, New Mexico, where they are played back simultaneously into the correlator. Real-time software and firmware controls the playback drives to achieve synchronization, compute models of the wavefront delay, control the numerous modules of the correlator, and record FITS files of the fringe visibilities at the back-end of the correlator. In addition to the more than 3000 custom VLSI chips which handle the massive data flow of the signal processing, the correlator contains a total of more than 100 programmable computers, 8-, 16- and 32-bit CPUs. Code is downloaded into front-end CPU's dependent on operating mode. Low-level code is assembly language, high-level code is C running under a RT OS. We use VxWorks on Motorola MVME147 CPU's. Code development is on a complex of SPARC workstations connected to the RT CPU's by Ethernet. The overall management of the correlation process is dependent on a database management system. We use Ingres running on a Sparcstation-2. We transfer logging information from the database of the VLBA Monitor and Control System to our database using Ingres/NET. Job scripts are computed and are transferred to the real-time computers using NFS, and correlation job execution logs and status flow back by the route. Operator status and control displays use windows on workstations, interfaced to the real-time processes by network protocols. The extensive network protocol support provided by VxWorks is invaluable. The VLBA Correlator's dependence on network protocols is an example of the radical transformation of the real-time world over the past five years. Real-time is becoming more like conventional computing. Paradoxically, 'conventional' computing is also adopting practices from the real-time world: semaphores, shared memory, light-weight threads, and concurrency. This appears to be a convergence of thinking.

Wells, D. C.

Correlation of the Coronal Mass Ejection Productivity of Solar Active Regions with Measures of their Global Nonpotentiality from Vector Magnetograms: Baseline Results

Conventional magnetograms and chromospheric and coronal images show qualitatively that the fastest coronal mass ejections (CMEs) are magnetic explosions from sunspot active regions where the magnetic field is globally strongly sheared and twisted from its minimum-energy potential configuration. We present measurements from active region vector magnetograms that start to quantify the dependence of an active region's CME productivity on the global nonpotentiality of its magnetic field. From each of 17 magnetograms of 12 bipolar active regions, we measured the size of the active region (the magnetic flux content, phi) and three separate measures of the global nonpotentiality (L(sub SS), the length of strong-shear, strong-field main neutral line: I(sub N), the net electric current connecting one polarity to the other; and alpha = (mu)I(sub N)/phi), a flux normalized measure of the field twist). From these measurements and the observed CME productivity of the active regions, we find that: (1) All three measures of global nonpotentiality are statistically correlated with the active region flux content and with each other; (2) All three measures of global nonpotentiality are significantly correlated with CME productivity. The flux content correlates with CME productivity, but at a lower statistically significant confidence level (less than 95%); (3) The net current is less closely correlated with CME productivity than alpha and the correlation of CME productivity with flux content is even weaker. If these differences in correlation strength, and a significant correlation of alpha with flux content, persist to larger active regions, this would imply that the size of active regions does not affect CME productivity except through global nonpotentiality; and (4) For each of the four global magnetic quantities, the correlation with CME productivity is stronger for a two-day time window for the CME production than for windows half as wide or twice as wide. This plausibly is a result of the most counterproductive active regions producing less than one CME per day, and from the active region's evolution often significantly changing the global nonpotentiality over the course of several days. These results establish that measures of active region global nonpotentiality from vector magnetograms (such as L(sub SS), I(sub N), and alpha) should be useful for prediction a active region CMEs.

Falconer, D. A.

TACT: A Set of MSC/PATRAN- and MSC/NASTRAN- based Modal Correlation Tools

This paper describes the functionality and demonstrates the utility of the Test Analysis Correlation Tools (TACT), a suite of MSC/PATRAN Command Language (PCL) tools which automate the process of correlating finite element models to modal survey test data. The initial release of TACT provides a basic yet complete set of tools for performing correlation totally inside the PATRAN/NASTRAN environment. Features include a step-by-step menu structure, pre-test accelerometer set evaluation and selection, analysis and test result export/import in Universal File Format, calculation of frequency percent difference and cross-orthogonality correlation results using NASTRAN, creation and manipulation of mode pairs, and five different ways of viewing synchronized animations of analysis and test modal results. For the PATRAN-based analyst, TACT eliminates the repetitive, time-consuming and error-prone steps associated with transferring finite element data to a third-party modal correlation package, which allows the analyst to spend more time on the more challenging task of model updating. The usefulness of this software is presented using a case history, the correlation for a NASA Langley Research Center (LaRC) low aspect ratio research wind tunnel model. To demonstrate the improvements that TACT offers the MSC/PATRAN- and MSC/DIASTRAN- based structural analysis community, a comparison of the modal correlation process using TACT within PATRAN versus external third-party modal correlation packages is presented.

Marlowe, Jill M.

Using CO2:CO Correlations to Improve Inverse Analyses of Carbon Fluxes

Observed correlations between atmospheric concentrations of CO2 and CO represent potentially powerful information for improving CO2 surface flux estimates through coupled CO2-CO inverse analyses. We explore the value of these correlations in improving estimates of regional CO2 fluxes in east Asia by using aircraft observations of CO2 and CO from the TRACE-P campaign over the NW Pacific in March 2001. Our inverse model uses regional CO2 and CO surface fluxes as the state vector, separating biospheric and combustion contributions to CO2. CO2-CO error correlation coefficients are included in the inversion as off-diagonal entries in the a priori and observation error covariance matrices. We derive error correlations in a priori combustion source estimates of CO2 and CO by propagating error estimates of fuel consumption rates and emission factors. However, we find that these correlations are weak because CO source uncertainties are mostly determined by emission factors. Observed correlations between atmospheric CO2 and CO concentrations imply corresponding error correlations in the chemical transport model used as the forward model for the inversion. These error correlations in excess of 0.7, as derived from the TRACE-P data, enable a coupled CO2-CO inversion to achieve significant improvement over a CO2-only inversion for quantifying regional fluxes of CO2.

Palmer, Paul I.

The Software Correlator of the Chinese VLBI Network

The software correlator of the Chinese VLBI Network (CVN) has played an irreplaceable role in the CVN routine data processing, e.g., in the Chinese lunar exploration project. This correlator will be upgraded to process geodetic and astronomical observation data. In the future, with several new stations joining the network, CVN will carry out crustal movement observations, quick UT1 measurements, astrophysical observations, and deep space exploration activities. For the geodetic or astronomical observations, we need a wide-band 10-station correlator. For spacecraft tracking, a realtime and highly reliable correlator is essential. To meet the scientific and navigation requirements of CVN, two parallel software correlators in the multiprocessor environments are under development. A high speed, 10-station prototype correlator using the mixed Pthreads and MPI (Massage Passing Interface) parallel algorithm on a computer cluster platform is being developed. Another real-time software correlator for spacecraft tracking adopts the thread-parallel technology, and it runs on the SMP (Symmetric Multiple Processor) servers. Both correlators have the characteristic of flexible structure and scalability.

Zheng, Weimin

Enhanced Correlation of SMART Active Flap Rotor Loads

This is a follow-on study to a 2010 correlation effort. Measured data from the SMART rotor test in the NASA Ames 40- by 80- Foot Wind Tunnel are compared with CAMRAD II calculations. As background, during the wind tunnel test, unexpectedly high inboard loads were encountered, and it was hypothesized at that time that due to changes in the flexbeams over the years, the flexbeam properties used in the analysis needed updating. Boeing Mesa, recently updated these properties. This correlation study uses the updated flexbeam properties. Compared to earlier studies, the following two enhancements are implemented: i) the inboard loads (pitchcase and flexbeam loads) correlation is included for the first time (reliable prediction of the inboard loads is a prerequisite for any future anticipated flight-testing); ii) the number of blade modes is increased to better capture the flap dynamics and the pitchcase-flexbeam dynamics. Also, aerodynamically, both the rolled-up wake model and the more complex, multiple trailer wake model are used, with the latter slightly improving the blade chordwise moment correlation. This sensitivity to the wake model indicates that CFD is needed. Three high-speed experimental cases, one uncontrolled free flap case and two commanded flap cases, are considered. The two commanded flap cases include a 2o flap deflection at 5P case and a 0o flap deflection case. For the free flap case, selected modifications to the HH-06 section flap airfoil pitching moment table are implemented. For the commanded 2o flap case, the experimental flap variation is approximately matched by increasing the analytical flap hinge stiffness. This increased flap hinge stiffness is retained for the commanded 0o flap case also, which is treated as a free flap case, but with larger flap hinge stiffness. The change in the mid-span and outboard loads correlation due to the updating of the flexbeam properties is not significant. Increasing the number of blade modes results in an effective, commanded flap hinge stiffness of 4X baseline, not 3X as reported earlier. The inboard loads correlation is reasonable, but needs further study. Overall, the free flap case correlation is reasonable, thus confirming the basic correctness of the current semi-empirical modifications; the correlation for the commanded 2o flap at 5P case and the 0o flap case is also reasonable.

Kottapalli, Sesi