Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “corporate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Evaluation of the Danish Aerospace Corporation Portable Pulmonary Function System

A research project designed to investigate changes in maximal oxygen consumption (VO2max) during and following long duration flight on the International Space Station (ISS) has recently been completed. The device used to measure VO2 on board ISS, the Portable Pulmonary Function System (PPFS) manufactured by the Danish Aerospace Corporation (DAC), is based on previous-generation devices manufactured by DAC, but the PPFS has not been validated for analyzing metabolic gases or measuring cardiac output (Qc). The purpose of the present evaluation is to compare PPFS metabolic gas analysis measurements to measurements obtained using a clinically-validated system (ParvoMedics TrueOne(c) 2400 system; Parvo). In addition, Qc data collected with the PPFS were compared to Qc measurements from echocardiography. METHODS: Ten subjects completed three cycle exercise tests to maximal exertion. The first test was conducted to determine each subject's VO2max and set the work rates for the second and third (comparison) tests. The protocol for the two comparison tests consisted of three 5-minute stages designed to elicit 25%, 50%, and 75% VO2max (based upon results from the initial test), followed by 1-minute stages of increasing work rate (25 watt/minute) until the subject reached maximal effort. During one of the two comparison tests, metabolic gases and Qc were assessed with the PPFS; metabolic gases and Qc were assessed with the Parvo and by echocardiography, respectively, during the other test. The order of the comparison tests was counterbalanced. VO2max and maximal work rate during the comparison tests were compared using t tests. Mixed-effects regression modeling was used to analyze submaximal data. RESULTS: All of the data were within normal physiological ranges. The PPFS-measured values for VO2max were 6% lower than values obtained with the Parvo (PPFS: 3.11 +/- 0.75 L/min; Parvo: 3.32 +/- 0.87 L/min; mean +/- standard deviation; P = 0.02); this difference is probably due to flow restriction imposed by the PPFS Qc accessories. Submaximal VO2 values were slightly lower when measured with the PPFS, although differences were not physiologically relevant. The PPFS-measured values of submaximal carbon dioxide production (VCO2) were lower than the data obtained from Parvo, which could be attributed to lower fractions of expired carbon dioxide measured by the PPFS. The PPFS Qc values tended to be lower than echocardiography-derived values. CONCLUSIONS: The results of the present study indicate a need to further examine the PPFS and to better quantify its reproducibility; however, none of the findings of the current evaluation indicate that the PPFS needs to be replaced or modified.

Portable Pulmonary Function System (PPFS)↗

Space Shuttle: Static pressure distribution on Chrysler Corporation Space Division SERV booster configuration

A dual purpose test was conducted in the propulsion wind tunnel (PWT) to evaluate the performance of an aerospike engine, in the presence of a booster, and obtain forebody and base pressure distributions on the booster in which it is installed. The test item was a 2.5 percent scaled replica of the SERV booster employing a 5 percent spike length aerospike engine installed in the base region of the model. Cold flow air was used to simulate engine jet operation. Two booster configurations were investigated, one on which reentry aerospike engine thermal protection doors were installed, and another where the doors were removed. The data presented are representative of the latter configuration for a Mach number range of 0 to 1.25 at angles of attack of 0 and 8 degrees and 0 degrees angle of sideslip.

Price, E. A.↗

Fault tree applications within the safety program of Idaho Nuclear Corporation

Computerized fault tree analyses are used to obtain both qualitative and quantitative information about the safety and reliability of an electrical control system that shuts the reactor down when certain safety criteria are exceeded, in the design of a nuclear plant protection system, and in an investigation of a backup emergency system for reactor shutdown. The fault tree yields the modes by which the system failure or accident will occur, the most critical failure or accident causing areas, detailed failure probabilities, and the response of safety or reliability to design modifications and maintenance schemes.

W. E. Vesely↗