Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “converter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Guest Editorial: Control interactions in power electronic converter dominated power systems

The modern power systems have undergone significant transformations at the generation, transmission, distribution, and utilization levels due to the remarkable advancements in power electronic converter technology. Power electronic converters are now prevalent in various applications, including wind turbine converters, photovoltaic inverters, flexible AC transmission systems (FACTS) and high-voltage DC (HVDC) converters, distributed generators, microgrids, and electric vehicles. The widespread adoption of power electronic converters has revolutionized the power system by providing fast and flexible controllability. However, their unique characteristics, such as fast response, multi-time scale dynamics, reconfigurable control, and varying sizes and capacities, have introduced new stability challenges, fundamentally altering the dynamics of modern power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Value Analysis of Medium-Voltage Back-to-Back Converter on DER Hosting Enhancement

This paper presents an analysis of the value that can be realized by medium-voltage back-to-back (MVB2B) converters in terms of the increased utilization rate of distributed energy resources (DERs) and the improvement in operational conditions. A systematic, transferrable, and scalable methodology has been designed to analyze and quantify the increased DER value from three perspectives: 1) curtailment reduction of the DER generation, 2) size reduction of the energy storage needed to otherwise realize DER hosting levels, and 3) hosting capacity improvement of the DERs compared to the base distribution circuit capability. In the case study, the proposed methodology is applied to two utility distribution systems for analysis and quantification of the grid value of the MVB2B converter, installed in the distribution circuit, and provided to the solar photovoltaic (PV) DERs. Here, the analysis results demonstrate that the MVB2B converter can deliver significant value to the PV hosting enhancement of two adjacent distribution systems when they are connected by the MVB2B converter. Based on this case study, this paper analyzes and summarizes the approximate realized grid value of the MVB2B converter for distribution systems dominated by different shares of customer classes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design, dynamic modeling and wave basin verification of a Hybrid Wave–Current Energy Converter

Massive and high-density Marine and Hydrokinetic (MHK) energy is contained in the ocean, including waves, tidal streams, and ocean currents. Traditional MHK energy converters harvest energy from only a single MHK energy source, which does not fully exploit the energy potential that co-exists in multiple forms of MHK energy in the ocean. This paper presents the design and dynamics of a Hybrid Wave–Current Energy Converter (HWCEC) that can simultaneously convert both wave and current energy to electricity with a single Power Take-off (PTO) through the engagement and disengagement of the three one-way clutches. The critical design parameters are analyzed through modeling and simulation, including the transmission ratios, the electrical impedance, and the turbine-heave plate distance. Water basin tests in a wave–current tank were conducted, which shows the prototyped HWCEC can improve the electric power output by 38%–71% for regular waves and 79% for irregular waves, while providing a 70% reduction of the Peak to Average Ratio (PAR) of power compared to the baseline Wave Energy Converter (WEC). Here we further analyze the occurring percentages of the instant power of both WEC and HWCEC in irregular wave tests, shedding new insight on how HWCEC reduces the PAR.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance characterization and modeling of an oscillating surge wave energy converter

Abstract Testing wave energy converters in the ocean could be expensive and complex, which necessitates the use of numerical modeling. However, accurately modeling the response of wave energy converters with high-fidelity simulations can be computationally intensive in the design stage where different configurations must be considered. Reduced-order models based on simplified equations of motion can be very useful in the design, optimization, or control of wave energy converters. Given the complex dynamics of wave energy converters, accurate representation, and evaluation of relative contributions by different forces are required. This effort is concerned with a performance characterization of the hydrodynamic response of an oscillating surge wave energy converter that is based on a reduced-order model. A state-space model is used to represent the radiation damping term. Morison’s representation of unsteady forces is used to account for the nonlinear damping. Wave tank tests are performed to validate simulations. A free response simulation is used to determine the coefficients of the state-space model. Torque-forced simulations are used to identify the coefficients of the nonlinear damping term for different amplitudes and wave frequencies. The impact of varying these coefficients on the response is investigated. An assessment of the capability of the model in predicting the hydrodynamic response under irregular forcing is performed. The results show that the maximum error is 3% when compared with high-fidelity simulations. It is determined that the nonlinear damping is proportional to the torque amplitude and its effects are more pronounced as the amplitude of the flap oscillations increases.

16 TIDAL AND WAVE POWER↗

Open Circuit Switch Fault Management Method of a Multi-Phase Synchronous Buck Converter for EV Charging Application

Multi-phase synchronous buck converter (MSBC) is becoming popular for the electric vehicle (EV) charging application because of its higher efficiency, smaller passive component sizes, bidirectional power flow, and output current ripple reduction through interleaving. This converter also provides higher reliability than the traditional single phase converter since its modular structure enables fault tolerant operation. Fault management in the converter requires the detection of switch fault, shut down of the faulty phase, and reconfiguration of the PWM signals for the healthy phases to avoid circulating current and high output current ripple. In addition, it is desirable that the fault management method can be implemented using the micro-controller unit (MCU) or digital signal processor (DSP), which are widely used to control power converters. This paper presents a fault management method for detecting switch faults and reconfiguring healthy phases using a DSP. The method is validated through simulations and experiments using a commercial off-the-shelf power stack.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Medium Voltage Testbed for the Performance and Function Tests of a 13.8 kV Power Conditioning System Converter

Medium voltage SiC devices facilitate the development of medium voltage grid-connected power electronics converters. However, it is difficult to test these converters directly on the real medium voltage grid, especially considering abnormal grid conditions, such as grid voltage and frequency variation, and different converter operation modes, such as grid-connected mode and islanded mode. This paper introduces the design and implementation of a medium voltage testbed, which supports tests of medium voltage converters in both grid-connected and islanded mode tests. In the grid-connected mode, the testbed can provide up to 13.8 kV grid voltage, can support the four-quadrant operation, and can emulate different grid conditions, such as voltage and frequency variation. In the islanded mode, the converter under test works as a voltage source and the testbed emulates a three-phase balanced or unbalanced load. Experiment test results are provided to validate the design and capability of the testbed.

Li, Haiguo↗

Enhancing EV Charging Station Resilience with Multifunctional Converter Leg Integration

In this paper, a multifunctional converter leg is integrated into an EV charger’s power circuit to enhance EV charging station resilience under power electronics converter device faults and grid outages. In the event of a device fault, it substitutes the failed converter leg, maintaining operation. During a grid outage, it assists the system as a fourth leg to the front-end converter, enabling grid-forming capability to supply power to the charging station critical loads while allowing limited power vehicle charging. The proposed approach’s effectiveness under both front-end power converter device faults and grid outage scenarios are validated through simulation and controller hardware-in-the-loop results.

Pereira Pinto, Joao [ORNL]↗

Wireless Pulse-Width Modulation Control of Power Converters Using Ultra-Wideband Technology for Distributed High-Voltage Systems

In this study, we present a new approach for wireless pulse-width modulation (PWM) control of a power converter, applicable to numerous power converters within a complex electrical distribution system. This method eliminates the need for multiple physical connections of gating/PWM signals among distributed converter modules. By using ultra-wideband-based communication, the PWM control signals can be wirelessly transmitted from a central controller to multiple converters simultaneously and seamlessly. System stability is thoroughly analyzed, and experimental results validate the efficacy of the wireless control scheme for a buck converter operating at a 50-kHz switching frequency. The minimum latency obtained from this setup is 5.38 ..mu..s. This control concept offers easier implementation of distributed control in high-voltage power systems, especially in multilevel architectures, even under harsh conditions with ambient noise.

ADVANCED PROPULSION SYSTEMS↗

An Inrush Current Limiting Method for Grid-Connected Converters Considering Grid Voltage Disturbances

To support the electric power grid, some grid-connected converters are required to ride through abnormal grid conditions, including voltage disturbances. However, at the moment, when a grid voltage disturbance happens, a large inrush current could be induced due to the large difference between the grid and converter output pulsewidth modulation (PWM) voltages. This inrush current could be more severe in the faster switching SiC-based multilevel converter, which only needs a small filter inductance to meet its normal operation requirements, such as harmonics and peak ripple currents. In this article, a PWM mask method is used to limit the inrush current. With this method, the inrush current can be effectively limited to a preset value and can help the converter ride through grid voltage disturbances. Furthermore, the method is validated through experiments conducted on a single-phase SiC-based five-level converter considering low voltage, high voltage, and phase angle disturbances.

42 ENGINEERING↗

A Flux Balancing Strategy for 10-kV SiC-Based Dual-Active-Bridge Converter

The transformer flux unbalance in dual-active-bridge (DAB) converters is a critical issue due to the electrical parameter and modulation mismatch, and load or control transients. Compared to low voltage DAB converters, the unbalance problem in medium voltage DAB converters may cause more severe problem, and become more difficult to deal with, because of the high operating voltage and insulation requirement. In this paper, a flux balancing strategy for a medium voltage (MV) DAB converter is proposed, including the transformer design with ferrite gap, current harmonic-based unbalance detection, as well as the flux balancing control scheme. With the proposed ferrite gap, nonlinear magnetizing current and its modeling are induced. Then, by analyzing the current harmonics, the flux unbalance level can be detected, and hence controlled. Test results have verified the proposed method in a MV DAB converter.

Gao, Zihan↗

Experimental Validation of a Modular All-Electric Power Take-Off Topology for Wave Energy Converter Enabling Marine Renewable Energy Interconnection

Power electronic converters are an enabling technology for the emerging marine energy applications, such as using ocean waves to produce electricity. This paper outlines the power take-off system and its key components used in a wave energy converter offering modularity and scalability to generate power efficiently. The proposed power take-off system was implemented based on a modular multilevel converter and could be deployed to convert any alternating current electrical energy to a different alternating current for interconnection to grid or non-grid applications. Examples of widespread deployment are supplying electricity to coastal communities or producing clean drinking water. The analysis using both the simulation tests and laboratory experiments verified the design objectives and basic functionality of the developed power take-off system. An acceptable response using a field programmable gate array-based controlled laboratory testbench was achieved, complying with guidelines specified in the prevalent industry standards. Seamless operation during steady-state and transients for the studied wave energy converter was achieved as supported by the obtained results. The key findings of this work were experimentally examined under different load conditions, direct current bus voltage fluctuations, and generator speed–torque regulation. The ability of the power take-off system to generate high-power quality of the waveforms, e.g., against adhering to the IEEE 519-2022 standard for total harmonic distortion limits, is also confirmed.

Engineering↗

Analysis of Inter Converter Interactions using Harmonic State Space Modeling

Power converters have become a key participant within the modern grid, facilitating the grid's interaction with renewable energy sources and various loads, among others. These converters can also interact with each other, creating harmonics that were previously absent in the grid. While some previous research studies have focused on inter-converter interactions, not much focus has been on the role of pulse width modulators in these inter-converter interactions. This paper focuses on the issue and builds upon harmonic state-space modeling (HSS) to observe inter-converter harmonic interactions. A new modulator model is developed, and its implementation within HSS modeling to observe harmonic coupling between multiple inverters is highlighted. A simulation testbench is developed, and to verify the advantages and limitations of the proposed modeling approach, it is compared with two other traditional modeling methods: namely, average and switching models. The proposed method is shown to be significantly more accurate and informative than conventional average modeling methods and has considerably lower computation costs and simulation time than detailed switching models. The results are verified using extensive simulations on MATLAB.

Xue, Yaosuo↗

Hexagonal Distributed Embedded Energy Converters (HexDEECs)

The HexDEEC is a small, characteristic length approximating a centimeter, energy transducer that converts the dynamic deformations of its elastomer housing into electricity through a variable capacitance charging-discharging cycle. This device is a type of Distributed Embedded Energy Converter Technology (DEEC-Tec), a new domain for marine renewable energy research that utilizes a conglomeration of small distributed embedded energy converters (DEECs) that, in aggregate, form larger metamaterial frameworks. These resulting DEEC-Tec metamaterials can then, in turn, be used to construct flexible ocean wave energy converters called flexWECs, which can utilize a broad band of ocean wave frequencies and lack highly loaded rigid bodies. These systems also provide new avenues of wave energy harvesting such as actively transforming topologies (e.g., shape and form) and morphologies (e.g., stiffness and damping throughout its entire structure) in real time. Presented, is one specific type of DEEC: the HexDEEC, which is currently being developed by the United States National Renewable Energy Laboratory. This transducer shows promise in aiding the adoption and further development of the DEEC-Tec domain. The following presentation focuses on the promise of this technology and current work being done to analyze the performance of an individual HexDEEC design. The HexDEEC is composed of a hyperelastic hexagonal housing, nominally silicon rubber, with six electrodes on its inner faces. The upper three electrodes share the same charge while the lower three electrodes oppose the upper electrode charges. Externally, the HexDEEC has two arms extending away from the middle vertices of the hexagon. Via principles governing the relationship between electrical capacitance and electrical potential (voltage and charge), electricity is generated when the HexDEEC's arms are dynamically pulled or released under tensile loading, as doing so causes the distance between the upper and lower sets of electrodes to change - varying the energy converter's overall capacitance. Analytical and numerical modeling is being used to evaluate the mechanics and electrical energy generated by the HexDEEC. Equations to describe the capacitance and electrostatic forces acting on this unique system have been developed and implemented into the numerical modeling software STAR-CCM+, along with models to describe its hyperelastic material, such as the Mooney-Rivlin 3-parameter model. So far, an initial design has been analyzed and we plan to further optimize it to increase power production. Individual HexDEECs have been fabricated by drawing uncured liquid silicon rubber into molds via vacuum pressure. To simplify manufacturing, HexDEEC sub-components - e.g., electrodes, wires - can be placed within those molds such that they are directly embedded into the hexagonal housing during the curing process. Furthermore, DEEC-Tec metamaterials can be created by interweaving or sequentially layering multiple HexDEEC strands together. The HexDEEC based metamaterial could then generate electricity through its gross deformations. Ultimately, HexDEECs represent a specific type of energy transducer that can be leveraged, by the DEEC-Tec domain, to create metamaterials used to construct novel flexWECs.

DEEC-Tec↗

Model predictive control for matrix converter operating in current control mode with load current estimation

A matrix converter system operating in current control mode is provided. The matrix converter includes a switching matrix coupled between a low voltage side and a high voltage side, wherein the matrix converter is coupled at its low voltage side to a generator for receiving an input power including an input current and transforming the input power into an output power at its high voltage side, wherein a load is coupled to the high voltage side. The control system includes a load observer and a model predictive controller (MPC). The load observer is configured to estimate a load current that flows to the load from the high voltage side of the matrix converter as a function of a switching state of the switching matrix, an output voltage output at the high voltage side of the matrix converter, and the input current. The MPC is configured to select the switching state of the switching matrix to meet one or more control objectives defined by minimization of a multi-objective function that tracks the output voltage and the input current using the estimated load current.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wireless Pulse-Width Modulation Control of Power Converters Using Ultra-Wideband Technology for Distributed High-Voltage Systems: Preprint

In this study, we present a new approach for wireless pulse-width modulation (PWM) control of a power converter, applicable to numerous power converters within a complex electrical distribution system. This method eliminates the need for multiple physical connections of gating/PWM signals among distributed converter modules. By using ultra-wideband-based communication, the PWM control signals can be wirelessly transmitted from a central controller to multiple converters simultaneously and seamlessly. System stability is thoroughly analyzed, and experimental results validate the efficacy of the wireless control scheme for a buck converter operating at a 50-kHz switching frequency. The minimum latency obtained from this setup is 5.38 mus. This control concept offers easier implementation of distributed control in high-voltage power systems, especially in multilevel architectures, even under harsh conditions with ambient noise.

ADVANCED PROPULSION SYSTEMS↗

Charge-Based Droop Control Addressing Control Saturation for Low-Inertia Converters

With bulky dc-link capacitors/inductors, traditional voltage-source converters (VSCs) and current-source converters (CSCs) feature a large inertia to facilitate the converter control under large transients. To achieve high power density with reduced cost, low-inertia converters (LICs) featuring significantly reduced dc-link capacitors/inductors have attracted growing attention. However, without bulky dc-link energy buffer, LICs are prone to control saturation under large transients, resulting in undesired oscillation and instability. This issue cannot be managed by traditional proportional-integral based control due to the low inertia. And it will deteriorate when several LICs are connected in series. To address this challenge in LICs, a model-predictive control (MPC) with a computation-inexpensive feed-forward compensation method has been proposed to provide fast dynamic responses. But it would suffer control saturation under larger transients that degrades the control performance. In this article, a charge-based droop control (CDC) is proposed to address this remaining challenge. This paper firstly analyzes the control saturation challenge in LICs by using a tri-port soft-switching solid-state transformer as an example. Next, the operating principle of the proposed CDC are introduced. Two different implementation approaches are discussed in detail. Lastly, the proposed scheme is validated in simulation with a high-fidelity model of hardware prototype. As a result, the proposed CDC eliminated the 2 kHz oscillation and reduced the dc-link ripple and overshoot due to control saturation by 75% and 50%, respectively.

30 DIRECT ENERGY CONVERSION↗

A Single-Stage Multilevel AC-DC Bidirectional Converter With Natural Grid Harmonic Elimination

Generally, AC-DC converters have an AC-DC stage followed by a DC-DC stage. In these two stage approaches, the AC-DC stage is hard-switched, whereas the DC-DC stage is soft-switched. Therefore, the devices in the AC-DC stage can be switched only at tens of kHz to avoid excessive switching losses, thus limiting the bandwidth of the current control loop. Hence, the control of these converters with distorted grid voltages requires multiple harmonic compensation loops or other complex control algorithms in order for the grid currents to comply with IEEE standards. By integrating both the stages, the devices in the AC-DC stage can also be soft-switched, thus facilitating higher switching frequency, and thereby higher current control bandwidth. This paper proposes an integrated multilevel bidirectional AC-DC converter with improved control bandwidth and disturbance rejection. It is shown experimentally that the high bandwidth current control loop of the converter can reject grid harmonic current disturbances, without the need for any compensation loops or complex control techniques, and comply with IEEE standards.

30 DIRECT ENERGY CONVERSION↗

System Identification of a DC-DC Buck Converter Based on Two-Channel Relay Method

This work presents a system identification approach based on a two-channel relay applied to a DC-DC buck converter operating in closed-loop with a PI controller to regulate its output voltage. The implemented two-relay method allows system identification while the system is running online. Moreover, the algorithm works in a closed-loop configuration while introducing a minimal perturbation in the converter's operation. The presented algorithm was used to identify the frequency response of the converter with no-prior knowledge about the system structure. Furthermore, the identified transfer function parameters has a good agreement with the mathematical model of the converter. Simulation results of the comparison between the switching model, mathematical model and the identified model are provided to validate the theoretical analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗