At least 55 records · Page 3

Utility Microgrid Controller Test Plan

The functional requirements of many microgrid controllers (MGCs) are expanding and evolving to meet growing utility and community needs. At a high level, the utility microgrid controller serves resilience and reliability use cases by coordinating transitions between grid-connected and islanded states and by managing the system during island operations. This includes control scenarios that require the microgrid controller to use flexible microgrid boundaries, maintain energy balance, coordinate with peer systems, and manage grid-forming (GFM) and grid-following (GFL) DER. In order to evaluate these functional enhancements, microgrid controller test plans must also be developed to ensure that the implemented controllers provide adequate performance. This report provides MGC test plans for both island operation and transition functions. The functions covered in this first edition report include feeder level energy management, island constraint management, secondary voltage and frequency control, black start, and synchronized reconnection. These test cases can be applied to utility-managed microgrid controllers that exclusively manage utility-owned equipment; the tests also apply to third-party managed microgrid controllers that coordinate with utility- and customer-owned equipment. The report can also be used by technology developers and project developers in industry to evaluate control strategies and performance characteristics for community microgrid controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Testing and Analysis of Grid Forming Inverter Control for Achieving Resilient and Economic Operation of an Islanded Microgrid

This investigation examines the feasibility of operating a battery energy storage system (BESS) in parallel with synchronous generation by using grid forming (GFM) control in order to achieve frequency control objectives while mitigating increases to operating costs in the context of an islanded microgrid. The BESS GFM control system, which is based on conventional droop techniques, is modeled along with the overall microgrid using the Real Time Digital Simulator (RTDS) to allow for integration of genset controller hardware. A series of simulations are performed to test the voltage and frequency regulation capability of the BESS control system when the primary frequency regulating genset is tripped offline. The results of the simulations suggest that the GFM control scheme will successfully maintain frequency and voltage stability, which will enable operation without a back-up genset while not compromising the microgrid resiliency to contingencies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laboratory Evaluation of Commercial Utility Microgrid Controller Test Results

The functional requirements of many microgrid controllers (MGCs) are expanding and evolving to meet growing utility and community needs. At a high level, the utility microgrid controller serves resilience and reliability use cases by coordinating transitions between grid-connected and islanded states and by managing the system during island operations. This includes control scenarios that require the microgrid controller to use flexible microgrid boundaries, maintain energy balance, coordinate with peer systems, and manage grid-forming (GFM) and grid-following (GFL) distributed energy resources (DER). In order to evaluate these functional enhancements, microgrid controller test plans must also be developed to ensure that the implemented controllers provide adequate performance. This report provides MGC test plans for both island operation and transition functions. The functions covered in this report include feeder level energy management, island constraint management, secondary voltage and frequency control, black start, and synchronized reconnection. This second edition update also includes results from applying the tests to a commercial utility microgrid controller. These results evaluate the performance and reliability of the controller under various operational scenarios. It identifies specific areas where the controller excels and highlights gaps that need to be addressed for future enhancements. The application of these test plans on real-world system behavior provides insights on commercial equipment readiness for field deployment. These test cases can be applied to utility-managed microgrid controllers that exclusively manage utility-owned equipment; the tests also apply to third-party managed microgrid controllers that coordinate with utility- and customer-owned equipment. The report can also be used by technology developers and project developers in industry to evaluate control strategies and performance characteristics for community microgrid controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demonstrating the Need for Adaptive Droop Control for Grid-Forming Inverters in Islanded and Grid-Connected Modes

This paper demonstrates the need of adaptive droop of grid-forming (GFM) inverters operating in different operation modes (grid-connected and islanded). A pure hardware microgrid comprising multiple grid-forming (GFM) inverters from different vendors, multiple grid-following inverters, and a diesel generator is used for the demonstration. The key findings are summarized as follows: Tighter droop slope should be used in the islanded mode, and looser droop slope should be used in the grid-connected mode to ensure stability. It is important to have adaptive droop control in GFM inverters to ensure stable and reliable microgrid operation.

14 SOLAR ENERGY↗

Load Shed Recovery With Transmission Switching and Intentional Islanding Methods After (N-2) Line Contingencies

Changing power system configuration may result in load shed recovery (LSR) because topology change can provide power flow control in meshed network. Some topologies may favor generation redispatch as compared to others and can eliminate line congestion which leads to LSR. One of the known methods for topology change is called transmission switching (TS) and research conducted in the past showed that TS is an effective means of mitigating load shedding. Another method of topology control is intentional islanding (IIS). In this manuscript, we explore IIS as a potential solution for LSR. IIS based on generator coherency has been presented in literature for mitigating cascading failures. However, IIS has not been explored solely as a LSR mechanism. In this paper, we compare the LSR based on IIS with well known LSR algorithm based on TS. The comparison is performed for IEEE 39-bus system and IEEE 118- bus system. The results show that IIS has a potential to perform better than TS in terms of computational efficiency and LSR.

42 ENGINEERING↗

What Crime? Legal Jurisdiction over Civilians in the Pacific Proving Ground

In late 1948 the Atomic Energy Commission “designated Enewetak Atoll as a permanent proving ground.” Subsequently renamed, the Pacific Proving Ground (PPG), six nuclear tests, including Mike, were conducted on the atoll. When Mike vaporized an entire island, it became clear that Enewetak’s small islands were insufficient and Bikini Atoll, abandoned after Operation Crossroads, was made part of the PPG. Authority to create the PPG resided in a “Trusteeship” agreement between the United States and the United Nations. Following the first World War, the Marshall Islands became a “Mandate” of the League of Nations. After World War II, the League’s successor, the United Nations, converted the Marshall Islands to a “Strategic Trusteeship” with the United States as its administrator. The Strategic Trust designation gave the U.S. nearly unfettered control over the islands, including the right to establish the PPG.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

How the Arrangement of Platinum Atoms on Ruthenium Nanoparticles Improves Hydrogen Evolution Activity

The platinum‐ruthenium (PtRu) system is highly active for hydrogen evolution reaction (HER) in alkaline media with both Pt and Ru playing active roles in the water dissociation step that generates adsorbed hydrogen atoms. Precise control of the arrangement of Pt atoms on Ru nanoparticles can maximize the Pt‐Ru sites for water dissociation and Pt‐Pt sites for hydrogen production and can considerably improve HER catalytic performance. By directing the growth and distribution of Pt on Ru hourglass nanoparticles, the arrangement of Pt on Ru is controlled into forming Pt islands, small Pt clusters, and strings of a few Pt atoms. Calculations show that the unique atomic string arrangements of Pt on Ru is the thermodynamically favorable configuration. Additionally, these strings have a favorable combination of Pt‐Ru and Pt‐Pt sites, making the Pt‐string on Ru the most active catalyst with a more than fivefold increase in turnover frequency for alkaline HER compared to the Pt‐island on Ru catalyst. The results show how controlling the Pt atomic arrangement on Ru nanoparticle surfaces for the tuning of Pt‐Pt and Pt‐Ru neighboring sites can direct toward a more efficient HER mechanism and thereby significantly enhancing HER performance.

36 MATERIALS SCIENCE↗

Study of Seamless Microgrid Transition Operation Using Grid-Forming Inverters

This paper investigates operational techniques to achieve seamless (smooth) microgrid (MG) transitions by dispatching a grid-forming (GFM) inverter. In traditional approaches, the GFM inverter must switch between grid-following (GFL) and GFM control modes during MG transition operation. Today's inverter technology allows GFM inverters to always operate in GFM control mode, so it is worth exploring how to use them to achieve smooth MG transition operation. This paper proposes three operational techniques: a traditional scheme of switching between GFL and GFM control; a new scheme of consistent GFM control and shifting the droop intercept up before islanding operation; and a new scheme of consistent GFM control and shifting the droop intercept up before synchronization operation. A full hardware setup is established to compare the three techniques and showcase their implementations in real-world applications. The results show that the third technique outperforms the others and exhibits the best transition performance because the GFM inverter maintains the same operating points during the transition operation. Therefore, we conclude that ensuring smooth MG transition operation requires that the GFM inverter(s) maintain the same operating points (v, f, P, Q, and phase angle) during the transition operation in addition to minimizes the point of common coupling power flow.

grid-forming control↗

Study of Seamless Microgrid Transition Operation Using Grid-Forming Inverters: Preprint

This paper investigates operational techniques to achieve smooth microgrid (MG) transitions by dispatching the grid-forming (GFM) inverter. In traditional approaches, the GFM inverter must switch between grid-following (GFL) and GFM control mode during MG transition operation. Today's inverter technology allows GFM inverters to always operate in GFM control mode, so it is worthy to explore how to use them to achieve smooth MG transition operation. This paper proposes three operational techniques: a traditional scheme of switching between GFL and GFM control; a new scheme of consistent GFM control and shifting the droop intercept up before islanding operation; and a new scheme of consistent GFM control and shifting the droop intercept up before synchronization operation. A full hardware setup is established to compare the three techniques and showcase their implementations in real-world applications. As expected, the third technique outperforms the others and exhibits the best transition performance because the GFM inverter maintains the same operating points during the transition operation. Therefore, we conclude that ensuring smooth MG transition operation requires the GFM inverter(s) to maintain the same operating points (v, f, P, Q, and phase angle) during the transition operation in addition to minimizes the point of common coupling power flow.

grid-following control↗

Controlling selective nucleation and growth of dysprosium islands on graphene by metal intercalation

We report metal intercalation is an effective method to modify the physical and chemical properties of low-dimensional systems such as epitaxial graphene. Here, we show that the nucleation and growth of metal nanostructures on epitaxial graphene on SiC(0001) can be dramatically changed by metal intercalation. Using scanning tunneling microscopy experiments, we demonstrate that dysprosium (Dy) metal islands are selectively nucleated on the area with Dy intercalation under both graphene and carbon buffer layers, while the adjacent area with only buffer layer intercalated remains relatively bare. Using first-principles calculations based on density functional theory, we show that adsorption of Dy adatom on the preferred nucleation area is energetically more favorable than on other areas. Moreover, changes in the electronic structure and the interlayer spacing upon Dy intercalation obtained from our calculations are also consistent with experimental observations. Our results indicate that metal intercalation is a promising way to manipulate the interaction between graphene and deposited adatoms.

2-dimensional systems↗

Impact of Load Tap Changer Control Operation Under Microgrid Conditions

Every microgrid is unique in its diversity of assets, operation, and network structure. This uniqueness presents challenges for each microgrid implementation that need to be understood and addressed to prevent power quality concerns, stability issues, and blackouts. In this research work, we present one challenge faced during microgrid operation that could potentially cause a blackout in some microgrid configurations. Through the incorrect operation of the load tap changer controller during an islanding event for a microgrid with generation present on both primary and secondary busses, the primary voltage will increase or decrease beyond allowable bounds, causing a cascading failure. This work presents the issue first with simulation results to demonstrate the phenomenon and then presents results of load tap changer controller operation using a controller-hardware-in-the-loop experiment. Finally, details of the complete sequence of operation and the blackout scenarios are presented and summarized.

blackout↗

A Novel Design for Switchable Grid-Following and Grid-Forming Control

This paper presents the design of a novel grid- forming (GFM) control structure adapted from a typical grid- following (GFL) control structure with minimal edits, thereby enabling a switchable control structure for voltage sourced converters (VSCs) to operate in either GFL or GFM mode by simply switching a flag manually. The VSC is shown to be able to operate in the GFL control mode synchronizing to the main grid through a phase-locked-loop (PLL) and operate as a GFM controller with power-based synchronization for both grid-connected and islanded conditions. To guarantee smooth operation, the control schemes and the mode switching logic have been carefully designed and examined via a series of experiments. Here, the experiment results show that the switchable control structure can fulfill the desired control and operation functions and enable smooth transition between control modes.

14 SOLAR ENERGY↗

Software Control Program For Transportable Microgrid State-of-charge Balancing And Frequency Stability Controls

A deterministic state-of-charge (SOC) balancing approach software control code is introduced as an integral secondary management to primary control layer of an islanded small microgrid or nanogrid system made up of multiple grid-forming inverter/battery/solar combination systems, where each set of batteries with each inverter are on independent DC buses (i.e. non-paralleled on the DC sides). A DERMS-level control approach, algorithm and automation controller program was developed to improve coordination and enable microgrid asset compliance and SOC balancing, enabling provision of a system-level power stability support architecture, load support, and asset scalability. The architecture is configured to treat each unit or micro/nano-grid as a node in a microgrid network, allowing for autonomous DERMS control regarding load and SOC balancing and power stability. As the network grows with the addition of units, greater coordination efforts may be required. The ideal small network microgrid ranges from 2-10 inverter/battery units before additional control parameters must be considered in the existing architecture. The control approach focuses on a deterministic state-of-charge analysis as the primary level control process followed by a secondary control loop using a forced frequency-watt droop strategy to conform off-the-shelf components into behaving under a leader-follower configuration. Adopting this control scheme has been shown to allow for a balanced, unit-coordinated microgrid network, enabling stable power flow. The deterministic state-of-charge approach is introduced as an integral primary control layer of an islanded small network microgrid. A standard strategy for SOC balancing is implementing a battery management system (BMS) to control SOC on the DC side. An alternative approach is to determine how to coordinate sending and receiving power on the AC side with multiple units. The latter approach assesses all the integrated units in the microgrid network. Once the individual units are identified, further system data is required to calculate each unit's total kWh, provided information about its capability to supply or consume kWh and availability. The secondary control layer in the multi-layered small network microgrid methodology uses the primary layer’s decision to initiate frequency setpoint changes, initializing the SOC balancing. The secondary control layer considers numerous system-dependent variables to enable a charging and discharging profile based on adjustable frequency setpoints. The combined architecture will result in stable, coordinated power flow enhancing an AC microgrid's functionalities.

Myers, KurtS [Idaho National Laboratory (INL), Ida↗

Cyber-Resilient Automatic Generation Control for Systems of AC Microgrids

In this paper we propose a co-design of the secondary frequency regulation in systems of AC microgrids and its cyber security solutions. We term the secondary frequency regulator a Micro-Automatic Generation Control (μ AGC) for highlighting its same functionality as the AGC in bulk power systems. We identify sensory challenges and cyber threats facing the μ AGC. To address the sensory challenges, we introduce a new microgrid model by exploiting the rank-one deficiency property of microgrid dynamics. This model is used to pose an optimal μ AGC control problem that is easily implemented, because it does not require fast frequency measurements. An end-to-end cyber security solution to the False Data Injection (FDI) attack detection and mitigation is developed for the proposed μ AGC. The front-end barrier of applying off-the-shelf algorithms for cyber attack detection is removed by introducing a data-driven modeling approach. Finally, we propose an observer-based corrective control for an islanded microgrid and a collaborative mitigation scheme in systems of AC microgrids. We demonstrate a collaborative role of systems of microgrids during cyber attacks. Furthermore, the performance of the proposed cyber-resilient μ AGC is tested in a system of two networked microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Action Effectiveness Monitoring and Research of Dredged Material Placement at Woodland Islands (Final Report)

Benthic invertebrates play critical ecosystem roles including the breakdown of organic matter, sediment mixing, and nutrient cycling. In the lower Columbia River and estuary, benthic invertebrates provide a foraging resource for threatened and endangered juvenile salmon. Driven by the goal to create low velocity, shallow water, and riparian shrub habitats to benefit juvenile salmon, the USACE placed 237,000 CY of dredged material, resulting in the deposition of 13.5 acres of sand on the off-channel margins at Woodland Islands. The Pacific Northwest National Laboratory (PNNL) designed and implemented an action effectiveness research study to understand how dredged material placement at Woodland Islands affected sediment conditions and benthic invertebrate assemblages. A Before-After-Control-Impact, or BACI, study design was used to evaluate the response of environmental conditions and benthic invertebrates to dredged material placement. The design included one impact site and two control sites. Sampling occurred for two years prior to dredged material placement and two years after. Our study found that spatial variation was a significant factor for both environmental and biological response variables which suggests local conditions are important considerations for mechanisms affecting benthic assemblages. We found that off-channel habitats across all locations sampled were producing benthic invertebrates, many of which are common prey items for juvenile salmon and steelhead—e.g., insects, chironomids, crustaceans, and corophium. There was a significant BACI effect (i.e., an effect at the dredged material placement site, relative to conditions at the control sites) for concentration of carbon and ammonium in sediment, but not for phosphorous concentrations or for percent sand. The estimated abundance for the three invertebrate response variables—total abundance, total chironomid abundance, and total corophium abundance—was significantly lower at the impact site after dredged material placement, compared to the control sites. At Woodland Island, the estimated mean abundance for all invertebrates combined decreased 28% after dredged material placement. Estimated mean abundances of chironomid and corophium decreased by 8% and 88%, respectively. While invertebrate abundances were lower after dredged placement, the composition of benthic invertebrates was similar before and after placement suggesting that as the new habitat feature evolves recolonization will likely follow. These findings provide a foundation for understanding potential benefits and consequences of repurposing dredged material for habitat creation in the LCRE.

54 ENVIRONMENTAL SCIENCES↗

Final Scientific Technical Report for "Microgrid RD&D and Testing of PIDC and PWD Systems"

Alstom Grid Inc’s (ALSTOM Grid) Research Design and Development (RD&D) project, “Microgrid RD&D and Testing for PIDC and PWD” was conducted in partnership with Philadelphia Industrial Development Corporation (PIDC) in its role as owner’s representative and manager of a vibrant commercial and industrial community, involving critical loads in one of the nation’s largest unregulated, non-military electric distribution systems. PIDC needed to develop solutions to address the planned considerable growth in Distributed Energy Resources (DER) Combined Heat Plan (CHP), Renewables, Distributed Generation (DG), Demand Response (DR) and Storage. In supporting the corporate objective, PIDC needed a new class of control systems for achieving enhanced energy resilience of their critical infrastructure operation during adverse conditions together with carbon emission reduction and optimization of the overall system operation economics through system energy efficiency during normal and emergency operating conditions. Additionally, PIDC anticipated the need to support a new class of commercial agreements with tenants, such as those for Urban Outfitters, for guaranteed one hundred percent (100%) grid resilience and electric power supply in case of utility outage conditions. The project was designed to address the challenges for the commercial & industrial (C&I) communities. But more importantly, the project included development of scalable and replicable solutions intended to target a multitude of the nation’s electric distribution communities. The project researched and developed a fully comprehensive prototype consisting of microgrid operation and control functions including islanding, synchronization and reconnection, protection, voltage, frequency, and power quality management, dispatch, and system resiliency. The project provided the foundation required to significantly enhance the overall national objectives set by the DOE for energy resilience, emission reduction and system energy efficiency improvement, including protection of critical infrastructure and public resources.

14 SOLAR ENERGY↗

Fast ion confinement in the presence of core magnetic islands in Wendelstein 7-X

The effect of magnetic islands in the core region of Wendelstein 7-X (W7-X) on fast ion confinement is explored through simulations with the BEAMS3D code. A magnetic configuration where the n/m = 5/5 island chain is shifted to r/a ~ 0.7 allows the exploration of core island physics in W7-X. The control coil system on W7-X allows the tuning of the island size either increasing the island width or decreasing it. A coupling of the BEAMS3D code to the FIELDLINES code provides a versatile mechanism for incorporating magnetic islands and stochastic regions into the BEAMS3D code. Collisionless simulations suggest that the presence of core islands degrade the confinement of passing particles in the region of the island chain. Full neutral beam simulations of W7-X show a similar behavior with confinement decreasing as the island width is increased. Comparisons between a vacuum magnetic field and low beta HINT2 simulation are made showing similar fast ion behavior. Measurements of lost fast ions in W7-X confirm this trend with the control coil suppressed island configuration showing lower losses than that with no control coils applied. Simulations of fast ion wall loads are performed suggesting no drastic change in loss pattern and a slight reduction in losses with minimized islands.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗