Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “control volume methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Statistical Multiobjective Optimization of Thiospinel CoNi 2 S 4 Nanocrystal Synthesis via Design of Experiments

Thiospinels, such as CoNi 2 S 4 , are showing promise for numerous applications, including as catalysts for the hydrogen evolution reaction, hydrodesulfurization, and oxygen evolution and reduction reactions; however, CoNi 2 S 4 has not been synthesized as small, colloidal nanocrystals with high surface-area-to-volume ratios. Traditional optimization methods to control nanocrystal attributes such as size typically rely upon one variable at a time (OVAT) methods that are not only time and labor intensive but also lack the ability to identify higher-order interactions between experimental variables that affect target outcomes. Herein, we demonstrate that a statistical design of experiments (DoE) approach can optimize the synthesis of CoNi 2 S 4 nanocrystals, allowing for control over the responses of nanocrystal size, size distribution, and isolated yield. After implementing a 2 5–2 fractional factorial design, the statistical screening of five different experimental variables identified temperature, Co:Ni precursor ratio, Co:thiol ratio, and their higher-order interactions as the most critical factors in influencing the aforementioned responses. Second-order design with a Doehlert matrix yielded polynomial functions used to predict the reaction parameters needed to individually optimize all three responses. A multiobjective optimization, allowing for the simultaneous optimization of size, size distribution, and isolated yield, predicted the synthetic conditions needed to achieve a minimum nanocrystal size of 6.1 nm, a minimum polydispersity (σ/$\bar{d}$) of 10%, and a maximum isolated yield of 99%, with a desirability of 96%. The resulting model was experimentally verified by performing reactions under the specified conditions. Furthermore, our work illustrates the advantage of multivariate experimental design as a powerful tool for accelerating control and optimization in nanocrystal syntheses.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Amplifying Nanoparticle Reinforcement through Low Volume Topologically Controlled Chemical Coupling

Here, we present a streamlined method to covalently bond hydroxylated carbon nanotubes (CNOH) within a polyphenol matrix, all achieved through a direct, solvent-free process. Employing an extremely small concentration of CNOH (0.01% w/w) along with topologically contrasting linkers led to a maximum of 5-fold increase in modulus and a 25% enhancement in tensile strength compared to the unaltered matrix, an order of magnitude greater reinforcement (w/w) compared to state-of-the-art melt-processed nanocomposites. Through dynamic mechanical analysis, low field solid-state nuclear magnetic resonance spectroscopy, and molecular dynamics simulations, we uncovered the profound influence of linker’s conformational degrees of freedom on the segmental dynamics and therefore the material’s properties.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The ICON-1.2 Hydrostatic Atmospheric Dynamical Core on Triangular Grids - Part 1: Formulation and Performance of the Baseline Version

A hydrostatic atmospheric dynamical core is developed for the purpose of global climate modelling. The model applies a finite difference method to discretize the primitive equations on spherical icosahedral grids, using C-type staggering with triangles as control volume for mass. This paper documents the numerical method employed in the baseline version of this model, discusses its properties, and presents results from idealized test cases. The evaluation shows that the new dynamical core is able to correctly represent the evolution of baroclinic eddies in the atmosphere and their role in meridional heat and momentum transport. The simulations compare well with the reference solutions, and converge as the horizontal resolution increases. First results from two aqua planet experiments are also presented, in which the equatorial wave spectra derived from tropical precipitation agree well with those simulated by a spectral transform model. The new dynamical core thus provides a good basis for further model development. Certain aspects of the model formulation that need further investigation and improvement are also pointed out.

atmospheric↗

Microstructural evolution in shear-punch tests: A comparative study of pure Cu and Cu-Cr alloy

Understanding the mechanisms behind microstructural evolution during shear deformation has been a long-standing area of interest. However, establishing a connection between microstructure, mechanical properties, and extent of shear deformation is challenging and requires refined experimental approaches. Shear-punch testing (SPT) provides a controlled method to introduce shear into small volumes of material that later can be subjected to detailed microstructural characterization. In this study, we utilize an SPT device to induce shear deformation to pure copper and a binary copper-chromium alloy. Electron backscatter diffraction and transmission electron microscopy were used to study the mechanisms of plastic deformation after SPT. Our results indicate that shear deformation of pure Cu produces a dense network of intercepting microshear bands upon sustained deformation. Twin boundaries undergo degradation into high angle grain boundaries due to simultaneous deviation from the axis-angle pair condition of 60° misorientation on [111] direction. The presence of 50% volume Cr particles in the soft Cu matrix fundamentally altered the shear deformation mechanism. Preferential deformation of the Cu matrix led to accelerated shear-induced formation of low and high angle grain boundaries, and subsequent grain refinement. Comparatively, no grain refinement occurred in pure Cu at a strain ~10 times larger (ϵ = 4.73) than that of the copper-chromium case (ϵ = 0.42). Overall, our study sheds light on the microstructural evolution during shear deformation and highlights the significant influence of particle reinforcements on the shear deformation mechanisms of metals.

36 MATERIALS SCIENCE↗

Optimized generation of high resolution breast anthropomorphic software phantoms

Purpose: The authors present an efficient method for generating anthropomorphic software breast phantoms with high spatial resolution. Employing the same region growing principles as in their previous algorithm for breast anatomy simulation, the present method has been optimized for computational complexity to allow for fast generation of the large number of phantoms required in virtual clinical trials of breast imaging. Methods: The new breast anatomy simulation method performs a direct calculation of the Cooper's ligaments (i.e., the borders between simulated adipose compartments). The calculation corresponds to quadratic decision boundaries of a maximum a posteriori classifier. The method is multiscale due to the use of octree-based recursive partitioning of the phantom volume. The method also provides user-control of the thickness of the simulated Cooper's ligaments and skin. Results: Using the proposed method, the authors have generated phantoms with voxel size in the range of (25-1000 {mu}m){sup 3}/voxel. The power regression of the simulation time as a function of the reciprocal voxel size yielded a log-log slope of 1.95 (compared to a slope of 4.53 of our previous region growing algorithm). Conclusions: A new algorithm for computer simulation of breast anatomy has been proposed that allows for fast generation of high resolution anthropomorphic software phantoms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

HPDR: High-Performance Portable Scientific Data Reduction Framework

The rapid growth in scientific data generation is outpacing advancements in computing systems necessary for efficient storage, transfer, and analysis, particularly in the context of exascale computing. With the deployment of first-generation exascale computing systems and next-generation experimental facilities, this gap is widening and necessitates effective data reduction techniques to manage enormous data volumes. Over the past decade, various data reduction methods, including lossless compression, error-controlled lossy compression, and data refactoring, have been developed to accelerate I/O in scientific workflows. Despite significant reductions in data volume, these methods introduce considerable computational overhead, which can become the new bottleneck in data processing. To mitigate this, GPU-accelerated data reduction algorithms have been introduced. However, challenges remain in their integration into exascale workflows, including limited portability across different GPU architectures, substantial memory transfer overhead, and reduced scalability on dense multi-GPU systems. To address these challenges, we propose HPDR, a high-performance and portable data reduction framework. HPDR is designed to enable the execution of state-of-the-art reduction algorithms across diverse processor architectures while reducing memory transfer overhead to 2.3 % of the original, resulting in up to 3.5× faster throughput compared to existing solutions. It also achieves up to 96% of the theoretical speedup in multi-GPU settings. In addition, evaluations on accelerating I/O operations at scale up to 1,024 nodes of the Frontier supercomputer demonstrate that HPDR can achieve up to 103 TB/s reduction throughput, providing up to 4× acceleration in parallel I/O performance compared to existing data reduction routines. This work highlights the potential of HPDR to significantly enhance data reduction efficiency in exascale computing environments.

Chen, Jieyang [University of Oregon]↗

Developing a Control Strategy for Minimum Airflow Setting Considering CO2 Level and Energy Consumption in a Variable Air Volume System

In an office building equipped with a Variable Air Volume (VAV) system, this paper introduces a novel method for controlling the minimum supply airflow fraction in each zone’s VAV box, having a capability to consider indoor CO2 level and energy consumption. The EnergyPlus simulation using the medium office prototype model was employed, which evaluated the performance of the energy and CO2 concentration for five VAV box airflow control strategies. The paper focuses on CO2 concentration-based airflow control method and compares it with other four methods including conventional single-max, reduced minimum single-max, demand-controlled ventilation(DCV), and dualmax control methods according to guidelines and common practices. The newly proposed control strategy directly correlates the minimum airflow fraction to CO2 concentration. A general trend emerged when comparing CO2 concentrations—lower minimum airflow fractions were associated with higher concentrations. The proposed control method effectively maintained low CO2 concentrations and enabled a lower airflow fraction contributing to energy consumption reduction. It was confirmed that heating energy consumption in climate zone 4A, 5B, and 6A showed a maximum saving of approximately 30% compared to the conventional single-max and dual max control strategies. It was found that cooling energy consumption in climate zone 4A and 6A can achieve a maximum saving of approximately 10% compared to the conventional control strategies. The proposed CO2 concentration-based control logic is promising as it not only improves the indoor air quality lowering the CO2 concentration in the occupied spaces, but also contributes to HVAC energy savings.

Lee, Jong Man↗

Modeling, design and thermal performance of a BIPV/T system thermally coupled with a ventilated concrete slab in a low energy solar house: Part 2, ventilated concrete slab

This paper is the second of two papers that describe the modeling and design of a building-integrated photovoltaic-thermal (BIPV/T) system thermally coupled with a ventilated concrete slab (VCS) adopted in a prefabricated, two-storey detached, low energy solar house and their performance assessment based on monitored data. The VCS concept is based on an integrated thermal-structural design with active storage of solar thermal energy while serving as a structural component - the basement floor slab ({proportional_to}33 m{sup 2}). This paper describes the numerical modeling, design, and thermal performance assessment of the VCS. The thermal performance of the VCS during the commissioning of the unoccupied house is presented. Analysis of the monitored data shows that the VCS can store 9-12 kWh of heat from the total thermal energy collected by the BIPV/T system, on a typical clear sunny day with an outdoor temperature of about 0 C. It can also accumulate thermal energy during a series of clear sunny days without overheating the slab surface or the living space. This research shows that coupling the VCS with the BIPV/T system is a viable method to enhance the utilization of collected solar thermal energy. A method is presented for creating a simplified three-dimensional, control volume finite difference, explicit thermal model of the VCS. The model is created and validated using monitored data. The modeling method is suitable for detailed parametric study of the thermal behavior of the VCS without excessive computational effort. (author)

14 SOLAR ENERGY↗

Method for printing low-density polymer structures

A method of forming a low-density three-dimensional article is provided. The method includes printing a low-density composition on a substrate to form at least one layer comprising the low-density composition. The low-density composition includes a (P) polymer component and (M) a microsphere component in a ratio by volume (P):(M). The method also includes selectively controlling a density of the low-density composition during printing to give the at least one layer on the substrate. Selectively controlling the density of the low-density composition includes varying the ratio (P):(M) during printing. The method further includes repeating the printing and selectively controlling the density of the low-density composition to form additional layer(s), thereby forming the low-density three-dimensional article. A low-density three-dimensional article prepared in accordance with the method is also provided.

Kunc, Vlastimil↗

Lattice calculation of light meson radiative leptonic decays

In this work, we perform a lattice QCD calculation of the branching ratios and the form factors\r\nof radiative leptonic decays P →ℓνℓγ (P= π,K) using Nf = 2+1 domain wall fermion ensembles\r\ngenerated by the RBC and UKQCD collaborations at the physical pion mass. We adopt the\r\ninfinite-volume reconstruction (IVR) method, which extends lattice data to infinite volume and\r\neffectively controls the finite-volume effects. This study represents a first step toward a complete\r\ncalculation of radiative corrections to leptonic decays using the IVR method, including both real\r\nphoton emissions and virtual photon loops. For decays involving a final-state electron, collinear\r\nradiative corrections, enhanced by the large logarithmic factors such as ln(m2\r\nπ/m2e) and ln(m2K/m2e), can reach the level of O(10%) and are essential at the current level of theoretical and experimental precision. After including these corrections, our result for π →eνeγ agrees with the PIBETA measurement; for K →eνeγ, our results are consistent with the KLOE data and exhibit a 1.7σtension with E36; and for K →µνµγ, where radiative corrections are negligible, our results confirm the previously observed discrepancies between lattice results and the ISTRA/OKA measurements at large photon energies, and with the E787 results at large muon–photon angles.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimization of yttrium-90 PET for simultaneous PET/MR imaging: A phantom study

Purpose: Positron emission tomography (PET) imaging of yttrium-90 in the liver post radioembolization has been shown useful for personalized dosimetry calculations and evaluation of extrahepatic deposition. The purpose of this study was to quantify the benefits of several MR-based data correction approaches offered by using a combined PET/MR system to improve Y-90 PET imaging. In particular, the feasibility of motion and partial volume corrections were investigated in a controlled phantom study. Methods: The ACR phantom was filled with an initial concentration of 8 GBq of Y-90 solution resulting in a contrast of 10:1 between the hot cylinders and the background. Y-90 PET motion correction through motion estimates from MR navigators was evaluated by using a custom-built motion stage that simulated realistic amplitudes of respiration-induced liver motion. Finally, the feasibility of an MR-based partial volume correction method was evaluated using a wavelet decomposition approach. Results: Motion resulted in a large (∼40%) loss of contrast recovery for the 8 mm cylinder in the phantom, but was corrected for after MR-based motion correction was applied. Partial volume correction improved contrast recovery by 13% for the 8 mm cylinder. Conclusions: MR-based data correction improves Y-90 PET imaging on simultaneous PET/MR systems. Assessment of these methods must be studied further in the clinical setting.

60 APPLIED LIFE SCIENCES↗

Hourglass control in staggered-grid hydrodynamics using virtual element stabilization techniques

Numerical simulations using the staggered-grid hydrodynamics (SGH) discretization suffer from hourglass instabilities. In this work, we develop a stabilization method to suppress the hourglass instabilities using techniques from the virtual element method (VEM). The stiffness matrix of the VEM consists of two terms: the consistency matrix which is rank deficient and the stability matrix. Here, we first show that in two dimensions and on general polygons, the stiffness matrix of the SGH is identical to the consistency matrix of the linear VEM for both the diffusion equation and the linear elasticity equation. These analyses explain the origin of the hourglass instabilities of the SGH discretization method, and establish a theoretical foundation for our proposed stabilization method by augmenting the stiffness matrix of the SGH discretization using the VEM stability matrix. Then, we present numerical examples using Lagrangian SGH simulations. The numerical experiments demonstrate that the proposed VEM stabilization method is effective at eliminating hourglass modes in the SGH discretization.

97 MATHEMATICS AND COMPUTING↗

A point-centered arbitrary Lagrangian Eulerian hydrodynamic approach for tetrahedral meshes

We present a three dimensional (3D) arbitrary Lagrangian Eulerian (ALE) hydrodynamic scheme suitable for modeling complex compressible flows on tetrahedral meshes. The new approach stores the conserved variables (mass, momentum, and total energy) at the nodes of the mesh and solves the conservation equations on a control volume surrounding the point. This type of an approach is termed a point-centered hydrodynamic (PCH) method. The conservation equations are discretized using an edge-based finite element (FE) approach with linear basis functions. All fluxes in the new approach are calculated at the center of each tetrahedron. A multidirectional Riemann-like problem is solved at the center of the tetrahedron. The advective fluxes are calculated by solving a 1D Riemann problem on each face of the nodal control volume. A 2-stage Runge–Kutta method is used to evolve the solution forward in time, where the advective fluxes are part of the temporal integration. The mesh velocity is smoothed by solving a Laplacian equation. The details of the new ALE hydrodynamic scheme are discussed. Results from a range of numerical test problems are presented.

97 MATHEMATICS AND COMPUTING↗

Asymmetric dose–volume optimization with smoothness control for rotating-shield brachytherapy

Purpose: It is important to reduce fluence map complexity in rotating-shield brachytherapy (RSBT) inverse planning to improve delivery efficiency while maintaining plan quality. This study proposes an efficient and effective RSBT dose optimization method which enables to produce smooth fluence maps. Methods: Five cervical cancer patients each with a high-risk clinical-target-volume (HR-CTV) larger than 40 cm{sup 3} were considered as the test cases. The RSBT source was a partially shielded electronic brachytherapy source (Xoft Axxent™). The anchor RSBT plans generated by the asymmetric dose–volume optimization with smoothness control (ADOS) method were compared against those produced by the dose–surface optimization (DSO) method and inverse-planning with simulated annealing (IPSA). Either L{sub 1}-norm or L{sub 2}-norm was used to measure the smoothness of a fluence map in the proposed ADOS method as one weighted term of the objective function. Uniform dwell-time scaling was applied to all plans such that HR-CTV D{sub 90} was maximized without violating the D{sub 2cc} tolerances of the rectum, bladder, and sigmoid colon. The quality of the anchor plans was measured with HR-CTV D{sub 90} of the anchor plans. Single-shielded RSBT [(S-RSBT), RSBT with single, fix sized delivery window] and dynamic-sheilded RSBT [(D-RSBT), RSBT with dynamically varying sized delivery window] delivery plans generated based on the anchor plans were also measured, with delivery time constraints of 10, 20, and 30 min/fraction (fx). Results: The average HR-CTV D{sub 90} values of the anchor plans achieved by the ADOS, DSO, and IPSA methods were 111.5, 94.2, and 107.4 Gy, respectively, where the weighting parameter β used in ADOS with L{sub 2}-norm was set to be 100. By using S-RSBT sequencing and 20 min/fx delivery time, the corresponding D{sub 90} values were 88.8, 81.9, and 83.4 Gy; while using D-RSBT sequencing with 20 min/fx delivery time, the corresponding D{sub 90} values were 91.4, 88.3, and 78.9 Gy, respectively. The average optimization times for ADOS, DSO, and IPSA were, respectively, 77, 4, and 1800 s. By using L{sub 1}-norm instead of L{sub 2}-norm in the ADOS method, the optimization time was increased by 20 s, while the D{sub 90} was reduced by 6.8 Gy on average. ADOS-L1 was found to be more sensitive to the weighting parameter than ADOS-L2. If β was increased to 10 000, the D{sub 90} drop with ADOS-L1 was 38 Gy, while the drop with ADOS-L2 is 13 Gy. Conclusions: The ADOS method had a reasonable optimization time cost, while achieving comparable RSBT dose plans as the IPSA method, which is of much higher time complexity. Compared to the DSO and IPSA methods, ADOS is able to generate anchor plans which are more suitable for RSBT delivery while preserving the high quality of the original plans. Compared to ADOS-L1, ADOS-L2 is able to achieve better quality of anchor plans more efficiently.

60 APPLIED LIFE SCIENCES↗

Electrokinetic Sample Preconcentration and Hydrodynamic Sample Injection for Microchip Electrophoresis Using a Pneumatic Microvalve

A microfluidic platform was developed to perform online electrokinetic sample preconcentration and rapid hydrodynamic sample injection for electrophoresis using a single microvalve. The PDMS microchip consists of a separation channel, a side channel for sample introduction, and a control channel which is used as a pneumatic microvalve aligned at the intersection of the two flow channels. The closed microvalve, created by multilayer soft lithography, can serve as a preconcentrator under an applied electric potential, enabling current to pass through while blocking bulk flow. Once analytes are concentrated, the valve is briefly opened and the stacked sample is pressure injected into the separation channel for electrophoretic separation. Fluorescently labeled peptides were enriched by a factor of ~450 in 230 s. The performance of the platform was validated by the online preconcentration, injection and electrophoretic separation of fluorescently labeled peptides. This method enables both rapid analyte concentration and controlled injection volume for high sensitivity, high resolution capillary electrophoresis.

capillary↗

Status Report on the Modeling of TRISO Energy Deposition, Time-Dependent Temperature Field and Doppler Feedback

The Doppler feedback mechanism is a major contributor to the passive safety of gas-cooled, graphite-moderated high temperature reactors that use fuel based on Tristructural-Isotropic coated particles. It follows that the correct prediction of the magnitude and time-dependence of this feedback effect is essential to the conduct of safety analyses for these reactors. We present a fuel conduction model for obtaining better estimates of the temperature feedback during moderate and fast transients. The fuel model has been incorporated in the CYNOD-THERMIX-KONVEK suite of coupled codes as a single TRISO particle within each calculation cell. The heat generation rate is scaled down from the neutronic solution and a Dirichlet boundary condition is imposed as the bulk graphite temperature from the thermal-hydraulic solution. This simplified approach yields similar results to those obtained with more complex methods, requiring multi-TRISO calculations within one control volume, but with much less computational effort. We provide an analysis of the hypothetical total control ejection event in the PBMR-400 design that clearly depicts the improvement in the predictions of the fuel temperature.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Improved Prediction of the Temperature Feedback in TRISO-Fueled Reactors

The Doppler feedback mechanism is a major contributor to the passive safety of gas-cooled, graphite-moderated high temperature reactors that use fuel based on Tristructural-Isotropic coated particles. It follows that the correct prediction of the magnitude and time-dependence of this feedback effect is essential to the conduct of safety analyses for these reactors. We present a fuel conduction model for obtaining better estimates of the temperature feedback during moderate and fast transients. The fuel model has been incorporated in the CYNOD-THERMIX-KONVEK suite of coupled codes as a single TRISO particle within each calculation cell. The heat generation rate is scaled down from the neutronic solution and a Dirichlet boundary condition is imposed as the bulk graphite temperature from the thermal-hydraulic solution. This simplified approach yields similar results to those obtained with more complex methods, requiring multi-TRISO calculations within one control volume, but with much less computational effort. An analysis of the hypothetical total control ejection in the PBMR-400 design verifies the performance of the code during fast transients. In addition, the analysis of the earthquake-initiated event in the PBMR-400 design verifies the performance of the code during slow transients. These events clearly depict the improvement in the predictions of the fuel temperature, and consequently, of the power escalations. In addition, a brief study of the potential effects of particle layer de-bonding on the transient behavior of high temperature reactors is included. Although the formation of a gap occurs under special conditions its consequences on the dynamic behavior of the reactor should be analyzed. The presence of a gap in the fuel can cause some unusual reactor behavior during fast transients, but still the reactor shuts down due to the strong feedback effects.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Towards local progression estimation of pulmonary emphysema using CT

Purpose: Whole lung densitometry on chest CT images is an accepted method for measuring tissue destruction in patients with pulmonary emphysema in clinical trials. Progression measurement is required for evaluation of change in health condition and the effect of drug treatment. Information about the location of emphysema progression within the lung may be important for the correct interpretation of drug efficacy, or for determining a treatment plan. The purpose of this study is therefore to develop and validate methods that enable the local measurement of lung density changes, which requires proper modeling of the effect of respiration on density. Methods: Four methods, all based on registration of baseline and follow-up chest CT scans, are compared. The first naïve method subtracts registered images. The second employs the so-called dry sponge model, where volume correction is performed using the determinant of the Jacobian of the transformation. The third and the fourth introduce a novel adaptation of the dry sponge model that circumvents its constant-mass assumption, which is shown to be invalid. The latter two methods require a third CT scan at a different inspiration level to estimate the patient-specific density-volume slope, where one method employs a global and the other a local slope. The methods were validated on CT scans of a phantom mimicking the lung, where mass and volume could be controlled. In addition, validation was performed on data of 21 patients with pulmonary emphysema. Results: The image registration method was optimized leaving a registration error below half the slice increment (median 1.0 mm). The phantom study showed that the locally adapted slope model most accurately measured local progression. The systematic error in estimating progression, as measured on the phantom data, was below 2 gr/l for a 70 ml (6%) volume difference, and 5 gr/l for a 210 ml (19%) difference, if volume correction was applied. On the patient data an underlying linearity assumption relating lung volume change with density change was shown to hold (fitR{sup 2} = 0.94), and globalized versions of the local models are consistent with global results (R{sup 2} of 0.865 and 0.882 for the two adapted slope models, respectively). Conclusions: In conclusion, image matching and subsequent analysis of differences according to the proposed lung models (i) has good local registration accuracy on patient data, (ii) effectively eliminates a dependency on inspiration level at acquisition time, (iii) accurately predicts progression in phantom data, and (iv) is reasonably consistent with global results in patient data. It is therefore a potential future tool for assessing local emphysema progression in drug evaluation trials and in clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗