Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “continuous air monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Microbiology and Crew Medical Events on the International Space Station

The closed environment of the International Space Station (ISS) creates an ideal environment for microbial growth. Previous studies have identified the ubiquitous nature of microorganisms throughout the space station environment. To ensure safety of the crew, microbial monitoring of air and surface within ISS began in December 2000 and continues to be monitored on a quarterly basis. Water monitoring began in 2009 when the potable water dispenser was installed on ISS. However, it is unknown if high microbial counts are associated with inflight medical events. The microbial counts are determined for the air, surface, and water samples collected during flight operations and samples are returned to the Microbiology laboratory at the Johnson Space Center for identification. Instances of microbial counts above the established microbial limit requirements were noted and compared inflight medical events (any non-injury event such as illness, rashes, etc.) that were reported during the same calendar-quarter. Data were analyzed using repeated measures logistic regression for the forty-one US astronauts flew on ISS between 2000 and 2012. In that time frame, instances of microbial counts being above established limits were found for 10 times for air samples, 22 times for surface samples and twice for water. Seventy-eight inflight medical events were reported among the astronauts. A three times greater risk of a medical event was found when microbial samples were found to be high (OR = 3.01; p =.007). Engineering controls, crew training, and strict microbial limits have been established to mitigate the crew medical events and environmental risks. Due to the timing issues of sampling and the samples return to earth, identification of particular microorganisms causing a particular inflight medical event is difficult. Further analyses are underway.

Oubre, Cherie M.↗

Stem CO2 Efflux measurements from Manaus, Brazil, 2017

This data was collected in order to test the effects of temperatures on the autotrophic respiratory process in the tropics. This data package contains raw real-time stem CO2 efflux files during the night and day from 3 different species near the K34 in Manaus during the day and the night. Raw and derived data files are included in the format of .csv and .xlsx and information about the canopy trees and temperatures recorded can be found in the field event log using microsoft excel. The data was collected from three canopy dominant trees in the central Amazon near the K34 tower. Real-time stem CO2 efflux was determined using a Li7000 gas analyzer configured in differential mode and connected to a dynamic stem chamber secured to the stem at breast height using straps to generate a reasonable seal. Ambient air was continuously pumped into the stem chamber and CO2 concentrations of the air entering and exiting the chamber were continuously monitored. CO2 efflux was calculated based on the CO2 concentration difference between ambient and stem chambers, the flow rate of air through the chamber, and the area of the enclosed stem. Additional auxiliary data, including sap flow and crown temperature were also measured. No data processing or QA/QC was done on the raw data packages.

54 ENVIRONMENTAL SCIENCES↗

A Side by Side Comparison of Filter-Based PM(sub 2.5) Measurements at a Suburban Site: A Closure Study

Reliable determination of the effects of air quality on public health and the environment requires accurate measurement of PM(sub 2.5) mass and the individual chemical components of fine aerosols. This study seeks to evaluate PM(sub 2.5) measurements that are part of a newly established national network by comparing them with a more conventional sampling system. Experiments were carried out during 2002 at a suburban site in Maryland, United States, where two samplers from the U.S. Environmental Protection Agency (USEPA) Speciation Trends Network: Met One Speciation Air Sampling System STNS and Thermo Scientific Reference Ambient Air Sampler STNR, two Desert Research Institute Sequential Filter Samplers DRIF, and a continuous TEOM monitor (Thermo Scientific Tapered Element Oscillating Microbalance) were sampling air in parallel. These monitors differ not only in sampling configuration but also in protocol-specific sample analysis procedures. Measurements of PM(sub 2.5) mass and major contributing species were well correlated among the different methods with r-values > 0.8. Despite the good correlations, daily concentrations of PM(sub 2.5) mass and major contributing species were significantly different at the 95% confidence level from 5 to 100% of the time. Larger values of PM(sub 2.5) mass and individual species were generally reported from STNR and STNS. The January STNR average PM(sub 2.5) mass (8.8 (micro)g/per cubic meter) was 1.5 (micro)g/per cubic meter larger than the DRIF average mass. The July STNS average PM(sub 2.5) mass (27.8 (micro)g/per cubic meter) was 3.8 (micro)g/per cubic meter larger than the DRIF average mass. These differences can only be partially accounted for by known random errors. Variations in flow control, face velocity, and sampling artifacts likely influence the measurement of PM(sub 2.5) speciation and mass closure. Simple statistical tests indicate that the current uncertainty estimates used in the STN network may underestimate the actual uncertainty.

Haines, Jennifer C.↗

JPL Electronic Nose

The JPL Electronic Nose (ENose) is a full-time, continuously operating event monitor designed to detect air contamination from spills and leaks in the crew habitat in the International Space Station. It fills the long-standing gap between onboard alarms and complex analytical instruments. ENose provides rapid, early identification and quantification of atmospheric changes caused by chemical species to which it has been trained. ENose can also be used to monitor cleanup processes after a leak or a spill.

Ryan, Margaret A.↗

Enhanced Raman Monitor Project

Monitoring of gaseous contaminants stems from the need to ensure a healthy and safe environment. NASA/Ames needs sensors that are able to monitor common atmospheric gas concentrations as well as trace amounts of contaminant gases. To provide an accurate assessment of air quality, a monitoring system would need to be continuous and on-line with full spectrum capabilities, allowing simultaneous detection of all gas components in a sample, including both combustible and non-combustible gases. The system demands a high degree of sensitivity to detect low gas concentrations in the low-ppm and sub-ppm regions. For clean and healthy air ('good' category), criteria established by the EPA requires that contaminant concentrations not exceed 4 ppm of carbon monoxide (CO) in an 8 hour period, 60 ppb of ozone(O3) in a one hour period and 30 ppb of sulfur dioxide (SO2) in a 24 hour period. One step below this is the National Ambient Air Quality Standard ('moderate' category) which requires that contaminant concentrations not exceed 9 ppm of carbon monoxide (CO), 120 ppb of ozone (O3) and 140 ppb of sulfur dioxide (SO2) for their respective time periods. Ideally a monitor should be able to detect the concentrations specified in the 'good' category. To benchmark current abilities of Raman technology in gas phase analysis, laboratory experiments were performed to evaluate the RASCAL II anesthetic gas monitor.

Westenskow, Dwayne↗

Development of a cw-laser-based cavity-ringdown sensor aboard a spacecraft for trace air constituents

The progress in the development of a sensor for the detection of trace air constituents to monitor spacecraft air quality is reported. A continuous-wave (cw), external-cavity tunable diode laser centered at 1.55 micrometers is used to pump an optical cavity absorption cell in cw-cavity ringdown spectroscopy (cw-CRDS). Preliminary results are presented that demonstrate the sensitivity, selectivity and reproducibility of this method. Detection limits of 2.0 ppm for CO, 2.5 ppm for CO2, 1.8 ppm for H2O, 19.4 ppb for NH3, 7.9 ppb for HCN and 4.0 ppb for C2H2 are calculated.

NASA Discipline Life Sciences Technologies↗

Design and Performance of a Gas Chromatograph for Automatic Monitoring of Pollutants in Ambient Air

In recent years, interest in air pollution constituents has focused on carbon monoxide and hydrocarbons as prime components of polluted air. Instrumental methods have been developed, and commercial instruments for continuous monitoring of these components have been available for a number of years. For the measurement of carbon monoxide, non-dispersive infrared spectroscopy has been the accepted tool, in spite of its marginal sensitivity at low parts-per-million levels. For continuously monitoring total hydrocarbons, the hydrogen flame ionization analyzer has been widely accepted as the preferred method. The inadequacy of this latter method became evident when it was concluded that methane is non-reactive and cannot be considered a contaminant even though present at over 1 ppm in the earth's atmosphere. Hence, the need for measuring methane separately became apparent as a means of measuring the reactive and potentially harmful non-methane hydrocarbons fraction. A gas chromatographic method for the measurement of methane and total hydrocarbons which met these requirements has been developed. In this technique, methane was separated on conventional gas chromatographic columns and detected by a hydrogen flame ionization detector (FID) while the total hydrocarbons were obtained by introducing a second sample directly into the FID without separating the various components. The reactive, or non-methane hydrocarbons, were determined by difference. Carbon monoxide was also measured after converting to methane over a heated catalyst to render it detectable by the FID. The development of this method made it possible to perform these measurements with a sensitivity of as much as 1 ppm full scale and a minimum detectability of 20 ppb. Incorporating this technique, criteria were developed by APCO for a second generation continuous automatic instrument for atmospheric monitoring stations.

Villalobos, R.↗

Aerosol Chemical Speciation Monitor (ACSM) Time-of-Flight (ToF) from Kennaook Cape Grim

When utilizing these data from Kennaook Cape Grim please acknowledge the Australian Bureau of Meteorology and the Commonwealth Scientific and Industrial Research Organisation (CSIRO) for their long-term and continued support of the Kennaook Cape Grim Baseline Air Pollution Monitoring Station. In addition, please contact the Lead Scientists responsible for the collection of these data sets (melita.keywood@csiro.au, ruhi.humphries@csiro.au and Erin.dunne@csiro.au) to discuss collaboration and authorship opportunities.

54 ENVIRONMENTAL SCIENCES↗

Liquid-Level Monitor for Pressurized Vessels

Technique for monitoring water levels in pressurized stainless-steel cylinders, based on differences in gamma-ray attenuation coefficients in water and air, developed. Full-scale laboratory prototype system constructed to test technique. Technique usable with liquids other than water, since linear attenuation coefficients for intermediate-energy gamma rays in air considerably lower than in liquids. Also adaptable for continuous monitoring of liquid levels in resevoir systems and in underground storage tanks.

Singh, J. J.↗

Determination of Benzene, Toluene, and Xylene by means of an ion mobility spectrometer device using photoionization

The continuous monitoring of changes on the quality of ambient air is a field of advantage of ion mobility spectrometry. Benzene, Toluene, and Xylene are substances of special interest because of their toxicity. We present an optimized drift tube for ion mobility spectrometers, which uses photo-ionization tubes to produce the ions to be analyzed. The actual version of this drift tube has a length of 45 mm, an electric field strength established within the drift tube of about 180 V/cm and a shutter-opening-time of 400 mus. With the hydrogen tube used for ionisation a mean flux of 10(exp 12) photons/sq cm s was established for the experiments described. We discuss the results of investigations on Benzene, Toluene, and Xylene in normal used gasoline SUPER. The detection limits obtained with the ion mobility spectrometer developed in co-operation are in the range of 10 ppbv in this case. Normally, charge transfer from Benzene ions to Toluene takes place. Nevertheless the simultaneous determination in mixtures is possible by a data evaluation procedure developed for this case. The interferences found between Xylene and others are rather weak. The ion mobility spectra of different concentrations of gasoline SUPER are attached as an example for the resolution and the detection limit of the instrument developed. Resolution and sensitivity of the system are well demonstrated. A hand-held portable device produced just now is to be tested for special environmental analytical problems in some industrial and scientific laboratories in Germany.

Leonhardt, J. W.↗

Cyber Resiliency and the Implementation of a Host-Based Intrusion Detection System in an Urban Air Mobility Environment

With the growth in Urban Air Mobility systems and the increasing reliance on interconnected technologies, ensuring the security of these complex components has become critical. As cities evolve into smart urban centers, the vulnerability to cyber threats escalates, possibly endangering citizens safety and the efficiency of transportation networks.In response to these challenges, this paper presents a study on the need for cyber resilient techniques within future air traffic environments. It will pay specific attention to the implementation of a Host-Based Intrusion Detection System (HIDS) utilizing Atomic OSSEC software, tailored specifically to a NASA simulation of an UrbanAirMobility environments’ unique demands. Further, this study seeks to outline the rational for NASA’s recommendation for a HIDS in such environments. It explores the design, development, and deployment of the proposed HIDS, focusing on its adaptability to monitor the hybrid nature of the Urban Air Mobility environment. Leveraging machine learning algorithms and anomaly detection techniques, the HIDS is equipped to continuously monitor and analyze the behavior of individual host systems, vehicles, and devices, thereby providing a proactive approach to threat detection. Implementing a HIDS is a pivotal strategy for enhancing cyber resiliency, as it gives an organization granular visibility into internal system activities, enables rapid detection and response to anomalous behavior and cyber threats, and fortifies the organizations overall cybersecurity posture. Finally, this study aims to provide recommendations and include learned takeaways that the Urban Air Mobility industry should consider. In brief, this paper highlights the significance of host-based intrusion detection in UrbanAirMobility environments and underscores the necessity of tailored security solutions to safeguard against emerging cyber threats.

UAM↗

Cloud Condensation Nuclei Particle Counter from Kennaook Cape Grim

When utilizing these data from Kennaook Cape Grim please acknowledge the Australian Bureau of Meteorology and the Commonwealth Scientific and Industrial Research Organisation (CSIRO) for their long-term and continued support of the Kennaook Cape Grim Baseline Air Pollution Monitoring Station. In addition, please contact the Lead Scientists responsible for the collection of these data sets (melita.keywood@csiro.au, ruhi.humphries@csiro.au and Erin.dunne@csiro.au) to discuss collaboration and authorship opportunities.

54 ENVIRONMENTAL SCIENCES↗

Baseline status of BOM instruments at Kennaook Cape Grim

When utilizing these data from Kennaook Cape Grim please acknowledge the Australian Bureau of Meteorology and the Commonwealth Scientific and Industrial Research Organisation (CSIRO) for their long-term and continued support of the Kennaook Cape Grim Baseline Air Pollution Monitoring Station. In addition, please contact the Lead Scientists responsible for the collection of these data sets (stuart.baly@bom.gov.au, melita.keywood@csiro.au, ruhi.humphries@csiro.au and Erin.dunne@csiro.au) to discuss collaboration and authorship opportunities.

54 ENVIRONMENTAL SCIENCES↗

Ultrafine Condensation Particle Counter from Kennaook Cape Grim (a1-level)

When utilizing these data from Kennaook Cape Grim please acknowledge the Australian Bureau of Meteorology and the Commonwealth Scientific and Industrial Research Organisation (CSIRO) for their long-term and continued support of the Kennaook Cape Grim Baseline Air Pollution Monitoring Station. In addition, please contact the Lead Scientists responsible for the collection of these data sets (melita.keywood@csiro.au, ruhi.humphries@csiro.au and Erin.dunne@csiro.au) to discuss collaboration and authorship opportunities.

54 ENVIRONMENTAL SCIENCES↗

Oxidation of commercial purity titanium

The oxidation kinetics of commercial purity Ti-A55 exposed to laboratory air in the 593-760 C temperature range were continuously monitored by thermogravimetric analysis. The oxide thickness was measured by microscopy, and the substrate contamination was estimated from microhardness measurements. The microhardness depth profiles were converted to oxygen composition profiles using calibration depth. The oxygen diffusion coefficient in alpha-Ti appears to be approximately concentration-independent in the 1-10 at. pct oxygen range. Diffusion coefficient for oxygen in TiO2 has been estimated as a function of temperature and is found to be about 50 times the value in alpha-Ti. The metallographically prepared cross sections of the oxidized specimens revealed a 'moving boundary' in the substrate, parallel to the oxide-metal interface. This boundary was associated with a specific oxygen level of 5.0 + or - 0.5 at. pct. It occurred at a distance from the oxide-metal interface which was correlatable with temperature and time of exposure. The diffusion coefficient corresponding to the composition of this moving boundary is in excellent agreement with the effective diffusion coefficient for the substrate contamination.

Unnam, J.↗

Self-reported health impacts of do-it-yourself air cleaner use in a smoke-impacted community

Smoke exposure from wildfires or residential wood burning for heat is a public health problem for many communities. Do-It-Yourself (DIY) portable air cleaners (PACs) are promoted as affordable alternatives to commercial PACs, but evidence of their effect on health outcomes is limited. Pilot test an evaluation of the effect of DIY PAC usage on self-reported symptoms, and investigate barriers and facilitators of PAC use, among members of a tribal community that routinely experiences elevated concentrations of fine particulate matter (PM 2.5 ) from smoke. We conducted studies in Fall 2021 (“wildfire study”; N = 10) and Winter 2022 (“wood stove study”; N = 17). Each study included four sequential one-to-two-week phases: 1) initial, 2) DIY PAC usage ≥8 h/day, 3) commercial PAC usage ≥8 h/day, and 4) air sensor with visual display and optional PAC use. We continuously monitored PAC usage and indoor/outdoor PM 2.5 concentrations in homes. Concluding each phase, we conducted phone surveys about participants’ symptoms, perceptions, and behaviors. We analyzed symptoms associated with PAC usage and conducted an analysis of indoor PM 2.5 concentrations as a mediating pathway using mixed effects multivariate linear regression. We categorized perceptions related to PACs into barriers and facilitators of use. No association was observed between PAC usage and symptoms, and the mediation analysis did not indicate that small observed trends were attributable to changes in indoor PM 2.5 concentrations. Small sample sizes hindered the ability to draw conclusions regarding the presence or absence of causal associations. DIY PAC usage was low; loud operating noise was a barrier to use. This research is novel in studying health effects of DIY PACs during wildfire and wood smoke exposures. Such research is needed to inform public health guidance. Recommendations for future studies on PAC use during smoke exposure include building flexibility of intervention timing into the study design.

54 ENVIRONMENTAL SCIENCES↗

Cleaned 5-Minute Resolution Air Quality and Meteorological Data from Nine TCEQ CAMS Sites in Houston, Texas (Nov 2021 – Oct 2022)

These data encompass 5-minute air monitoring and meteorological observations collected in the greater Houston, Texas metropolitan region, at nine (9) Continuous Ambient Monitoring Stations (CAMS) operated by the Texas Commission on Environmental Quality (TCEQ) between November 1, 2021 and October 31, 2022. The CAMS sites (CAMS 1, 8, 35, 45, 148, 403, 405, 410, and 1052) were chosen because their instrumentation includes measurements of PM2.5. These sites also provide continuous multi-parameter air-quality and meteorological measurements. Particulate matter (PM2.5, PM10) was sampled along with several trace gases, including ozone (O3), nitrogen oxides (NO, NO2, NOx), sulfur dioxide (SO2), and carbon monoxide (CO). The data set also contains standard surface meteorological parameters (temperature, humidity, pressure, wind speed, and wind direction). Several sites also include AutoGC-based measurements of volatile organic compounds (VOCs). Air monitoring instruments deployed at the selected sites comprise the following systems: BAM-1020 or TEOM (PM2.5), Thermo Scientific TEI 49i (O3), TEI 42i (NOx), and AutoGCs (VOCs). This data set is similar to the data included within the houairq5mX1.00 datastream, except for a few additional quality control steps. A systematic data cleaning and verification process was performed on the data set to ensure its quality and preparation for analysis. Removal of non-numeric status flags (e.g., [LIM], [QAS], [SPZ], [CAL], [PMA], [AQI], [SPN], [MAL]) was accomplished by employing rule-based string parsing to extract valid numerical values. Missing entries were set to -9999; however, invalid or anomalous values (e.g., 99999) were retained as originally reported by the TCEQ to preserve data provenance. The time sequence was verified for completeness, removal of duplicates, and uniformity at 5-minute intervals. Column labeling was standardized, and corresponding values were assessed for physical plausibility. All timestamps in the data set were reported in Coordinated Universal Time (UTC) as provided by the TCEQ. Further, the latitude and longitude coordinates were added for each CAMS site. A subset of the data (June 1–September 30, 2022) has been used in the following publication: Subba et al. 2025. “Implications of sea breeze circulations on boundary layer aerosols in the southern coastal Texas region.” EGUsphere 2025: 1–49, https://doi.org/10.5194/egusphere-2025-2659.

latitude↗

The Aura Mission and Its Application to Climate and Air Quality

NASA's Aura satellite is scheduled to launch in the second quarter of 2004 into a polar orbit. The Aura mission is designed to collect data to address three high priority environmental science questions: (1) Is the ozone layer recovering as expected? (2) What are the sources and processes that control tropospheric pollutants? And (3) what is the quantitative impact of constituents on climate change? Aura will answer these questions by globally measuring a comprehensive set of trace gases and aerosols in the troposphere and stratosphere. Aura data will also have applications for monitoring and predicting climate and air quality parameters. Aura s observations will continue the TOMS ozone trend record and provide an assessment as to whether the Montreal Protocol is achieving its objective. Aura will measure gases and aerosols in the upper troposphere and lower stratosphere that contribute to climate forcing. These data will be of sufficient coverage, vertical resolution, and accuracy to help constrain climate models. In addition, Aura observations of tropospheric ozone and its precursors will have regional as well as intercontinental coverage, which could improve emission inventories. Near real time data will tested for local air quality forecasts in collaboration with the US's Environmental Protection UV-B forecasts from Aura ozone and cloud cover data. An overview of Aura s instruments, data products, validation, and examples of data applications will be presented.

Hilsenrath, Ernest↗