38 records · Page 3

Compaction of crushed salt for safe containment – a summary of the KOMPASS projects

Abstract. For the underground disposal of high-level nuclear waste in rock salt formations, the safety concept includes the backfilling of open cavities with crushed salt. For the prognosis of the sealing function of the backfill for the safe containment of the radioactive waste, it is crucial to have a comprehensive process understanding of the crushed-salt compaction behavior. The crushed-salt compaction process is influenced by internal properties (e.g., grain size, mineralogy, and moisture content) and boundary conditions (e.g., temperature, stress state, and compaction rate) and, therefore, involves several coupled thermal–hydro–mechanical (THM) processes (Hansen et al., 2014; Kröhn et al., 2017). With the paradigm shift from the limited release of radionuclides to safe containment due to the German Repository Site Selection Act passed in 2017, the importance of crushed salt as geotechnical barrier has increased, with a focus on the evolution of its hydraulic properties. Based on the knowledge gaps in the current process understanding, the “Compaction of crushed salt for safe containment” (KOMPASS) projects were initiated to improve the scientific basis behind using crushed salt for the long-term isolation of high-level nuclear waste within rock salt repositories. The efforts to improve the prediction of crushed-salt compaction begun during the first phase of the KOMPASS projects (Czaikowski et al., 2020) and were followed up in a second phase ending in June 2023. The primary achievements of the projects are as follows (Czaikowski et al., 2020; Friedenberg et al., 2022): specification of the KOMPASS reference material, an easily available and reproducible synthetic crushed-salt material, for generic investigations; development of pre-compaction methods and successful production of samples in the short term and under in situ loading conditions; formulation of an extended laboratory program addressing the isolated investigation of known relevant factors influencing the compaction behavior of crushed salt (Düsterloh et al., 2022); execution of long-term compaction tests addressing isotropic and deviatoric load changes, temperature, and compaction state; construction of a backfill body using the KOMPASS reference material in the Sondershausen mine through collaboration with the SAVER (Entwicklung eines salzgrusbasierten Versatzkonzepts unter der Option Rückholbarkeit) project (Schaarschmidt and Friedenberg, 2022); advancement of the tools for microstructure investigation methods (Svensson and Laurich, 2022); generation (first stages) of a microphysical process list combining literature research with our own findings; benchmarking of long-term compaction test for model development and optimization of various existing models as well as the development of new models; application of a virtual demonstrator (2D model representing a backfilled drift in rock salt) for the visualization of developments and the quantification of the models (Rabbel, 2022). In summary, the KOMPASS projects contributed to the reduction of uncertainties and the strengthening of the safety case for using crushed salt within rock salt repositories.

Friedenberg, Larissa↗

AGC-4 Experiment Irradiation Monitoring Data Qualification Final Report

The Graphite Technology Development Program ran a series of six experiments to quantify the effects of irradiation on nuclear grade graphite. This report focuses on the fourth experiment, Advanced Graphite Creep 4 (AGC 4). The Advanced Reactor Development (ARD) Technology Development Office (TDO) Program for research and development activities require documentation of qualified monitoring data to design and license the first high-temperature reactor nuclear plant. Qualified data meets the requirements for use as described in the experiment planning and quality assurance documents. Failed data do not meet the requirements and provide no useable information. Trend data may not meet all requirements but still provide some useable information. Use of Trend data requires assessment of how any deficiencies affect a particular use of the data. AGC-4 began with Advanced Test Reactor (ATR) Cycle 157D on May 30, 2015. After irradiating the graphite for two cycles, the capsule was removed from the reactor after ATR Cycle 158A, which ended on January 2, 2016, due to interference with another experiment. Irradiation was resumed with Cycle 162A on October 7, 2017 after the interfering experiment was removed from the reactor. AGC-4 irradiation completed by the end of Cycle 166B on January 10, 2020. Between Cycles 162A and 166B, AGC-4 capsule was removed from the reactor core during two Powered Axial Locator Mechanism (PALM) Cycles 163A and 165A to avoid overheating. All thermocouples (TCs) have functioned throughout the AGC-4 experiment. A total of 9,256,184 out of all 11,167,213 temperature records (or 82.9%) are Qualified for use by the ARD Program and 1,911,029 missing values are Failed. Argon, helium, and total gas flow data were within expected ranges, except only eight out-of-range values occurred during outages. A total of 21,240,627 out of all 22,288,5103 gas flow rates (or 92.8%) are Qualified for use by the ARD Program and 1,644,476 are Failed records mostly due to missing values. Discharge gas line moisture values were consistently low during full ATR power, except for 162B, when moisture content was increasing to more than 200 ppmv by the end of this cycle. During outages, moisture content reached as high as 700 ppmv. 1,089,941 out of a total of 1,107,331 moisture values (or 98.4%) are within the measurement range of the instrument and are Qualified for use by the ARD Program and 17,390 missing moisture values are Failed. Graphite creep specimens were subjected to one of three loads: 393, 491, or 589 lbf. For a brief period during Cycle 157D between 12:19 on June 2, 2015, and 08:23 on June 11, 2015, the load cells were wired incorrectly, resulting in missing stack load data. Missing stack loads were estimated from measured ram pressures using regression equations developed from the existing data from Cycle 157D. Estimated stack loads during this period are considered to be an accurate representation of actual load applied to the stacks. These loads deviate slightly from the planned loads. This deviation does not prevent the data from being Qualified for use but must be taken into account when analyzing the effect of load on creep. 6,095,728 out of a total of 6,403,985 moisture values (or 95.2%) are within the measurement range of the instrument and are Qualified for use by the ARD Program and 308,257 missing load values are Failed. Stack displacement increased consistently throughout the eight cycles, with total displacement reached highest value of 2.4 in by the end of irradiation. During ATR outages, a set of pneumatic rams raised the stacks of graphite creep specimens to ensure the specimens were not stuck within the test train. This stack raising was performed seven times throughout irradiation. All stacks were raised successfully each time. 4,744,974 out of a total of 6,094,513 displacement values (or 77.9%) are within the measurement range of the instrument and are Qualified for use by the ARD Program and 1,349,539 displacement values are Failed mostly due to missing values. Analyses were conducted on correlations between TCs to look for trends and step changes that might indicate instrument degradation or failure. Correlation analysis was used to identify instances when TCs form short circuits, referred to as virtual junctions, which result in TCs reporting temperatures from some location in the capsule other than the location where they were intended to read. No evidence of virtual junctions was found. Analyses were also conducted on control charts of temperature differences of between two TCs, which are expected to behave consistently throughout the entire irradiation period. Upward or downward trend over time indicates at least one TC in the pair was drifted. Examining control charts for all 66 possible pairs out of twelve TCs installed in the AGC-4 capsules reveal no clear drift failures occurred, except unstable behavior of two TCs in Zone 3, TC-7 and TC-8, over irradiation time. In conclus

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗