Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “connected lighting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A Review of Existing Test Methods for Occupancy Sensors

One of the key new features of connected lighting systems (CLS) is their ability to collect data from various types of integral sensors and share that data with other lighting or building systems. Occupancy and vacancy sensors have been widely adopted as an energy-saving strategy in buildings, yet published test methods for reproducibly characterizing their performance remain few and limited in their sophistication. As a result, it has been difficult to predict their performance in a specific application, and in practice, they frequently do not meet energy-savings expectations. Occupants at times remove or otherwise bypass occupancy sensors that hinder their work or otherwise do not perform as expected, thereby compromising the sensors’ potential to reduce energy consumption. Poor performance can result from multiple causes – ranging from fundamental limitations of the sensor technology, to misconfiguration, to poor placement in the room or space. Innovative occupancy sensors, some of them combining multiple sensing technologies, have come on the market over the years, with claims of improved performance compared to their predecessors; yet in practice, their performance has led to neither high deployment nor high user satisfaction in any significant application, nor has it differed enough from the performance of previous products to necessitate a test method that facilitated comparison between them. While the performance of both common and novel occupancy sensors has been the subject of many published research articles, the test methods that have been employed for them have typically been loosely described and incorporated custom equipment or techniques that render them difficult to reproduce, or have been limited in their ability to fairly characterize devices that utilize varying sensor technology. The lack of a well-described, technology-agnostic test method that yields reproducible results across different implementations has been a barrier to the commercial success of new occupancy sensor products, as users and specifiers who have been disappointed with previous products are often unwilling to take a chance with new ones. Motivated by a desire to fairly characterize new technologies that continue to enter the market and claim not only improved occupancy detection but, in some cases, also additional capabilities (e.g., the ability to measure traffic or discern between different object types), this report presents the results of a literature review of recent published, well-described test methods for characterizing occupancy sensor performance, as well as research articles containing ad-hoc test methods. The review also identifies and consolidates the best techniques for characterizing sensor performance in indoor spaces and identifies test method gaps that need to be filled in order to evaluate emerging technologies and products.

47 OTHER INSTRUMENTATION↗

Two-pion contribution to the hadronic vacuum polarization with staggered quarks

We present results from the first lattice QCD calculation of the two-pion contributions to the light-quark connected vector-current correlation function obtained from staggered-quark operators. We employ the MILC Collaboration’s gauge-field ensemble with 2 + 1 + 1 flavors of highly improved staggered sea quarks at a lattice spacing of a ≈ 0.15 fm with a light sea-quark mass at its physical value. The two-pion contributions allow for a refined determination of the noisy long-distance tail of the vector-current correlation function, which we use to compute the light-quark connected contribution to hadronic vacuum polarization (HVP) with improved statistical precision. We compare our results with traditional noise-reduction techniques used in lattice QCD calculations of the light-quark connected HVP, namely, the so-called fit and bounding methods. We observe a factor of roughly 3 improvement in the statistical precision in the determination of the HVP contribution to the muon’s anomalous magnetic moment over these approaches. We also lay the group theoretical groundwork for extending this calculation to finer lattice spacings with increased numbers of staggered two-pion taste states.

Lahert, Shaun [Utah U.; Illinois U., Urbana] (ORCI↗

Long-Distance Window of the Hadronic Vacuum Polarization for the Muon g − 2

We provide the first calculation of the Euclidean long-distance window of the isospin-symmetric light-quark connected contribution to the hadronic vacuum polarization for the muon g − 2 and find a μ LD , iso , conn , ud = 411.4 ( 4.3 ) ( 2.4 ) × 10 − 10 . We also provide the currently most precise calculation of the total isospin-symmetric light-quark connected contribution, a μ iso , conn , ud = 666.2 ( 4.3 ) ( 2.5 ) × 10 − 10 in the BMW20 world, which is more than 4 σ larger compared to the data-driven estimates of Boito [] and 1.7 σ larger compared to the lattice QCD result of BMW20. Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hadronic vacuum polarization for the muon 𝑔 − 2 from lattice QCD: Complete short and intermediate windows

We present complete results for the hadronic vacuum polarization (HVP) contribution to the muon anomalous magnetic moment 𝑎 𝜇 in the short- and intermediate-distance window regions, which account for roughly 10% and 35% of the total HVP contribution to 𝑎 𝜇 , respectively. In particular, we perform lattice-QCD calculations for the isospin-symmetric connected and disconnected contributions, as well as corrections due to strong-isospin breaking. For the short-distance window observables, we investigate the so-called log-enhancement effects as well as the significant oscillations associated with staggered quarks in this region. For the dominant, isospin-symmetric light-quark-connected contribution, we obtain 𝑎$^{𝑙⁢𝑙,SD}_{𝜇⁡}$(conn) = 48.139⁢(11) stat ⁢(91) syst ⁢[92] total × 10 −10 and 𝑎$^{𝑙⁢𝑙,W}_{𝜇}$⁡(conn) = 206.90⁢(14) stat ⁢(61) syst ⁢[63] total × 10 −10 . We use Bayesian model averaging to fully estimate the covariance matrix between the individual contributions. Our determinations of the complete window contributions are 𝑎$^{SD}_{𝜇}$ = 69.05⁢(1) stat⁢ (21) syst ⁢[21] total × 10 −10 and 𝑎$^{W}_{𝜇}$ = 236.45⁢(17) stat⁢ (83) syst ⁢[85] total × 10 −10 . This work is part of our ongoing effort to compute all contributions to HVP with an overall uncertainty at the few-permille level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hadronic vacuum polarization for the muon g - 2 from lattice QCD: Complete short and intermediate windows

We present complete results for the hadronic vacuum polarization (HVP) contribution to the muon anomalous magnetic moment a μ in the short- and intermediate-distance window regions, which account for roughly 10% and 35% of the total HVP contribution to a μ , respectively. In particular, we perform lattice-QCD calculations for the isospin-symmetric connected and disconnected contributions, as well as corrections due to strong-isospin breaking. For the short-distance window observables, we investigate the so-called log-enhancement effects as well as the significant oscillations associated with staggered quarks in this region. For the dominant, isospin-symmetric light-quark-connected contribution, we obtain a μ l l , SD ( conn ) = 48.139 ( 11 ) stat ( 91 ) syst [ 92 ] total × 10 - 10 and a μ l l , W ( conn ) = 206.90 ( 14 ) stat ( 61 ) syst [ 63 ] total × 10 - 10 . We use Bayesian model averaging to fully estimate the covariance matrix between the individual contributions. Our determinations of the complete window contributions are a μ SD = 69.05 ( 1 ) stat ( 21 ) syst [ 21 ] total × 10 - 10 and a μ W = 236.45 ( 17 ) stat ( 83 ) syst [ 85 ] total × 10 - 10 . This work is part of our ongoing effort to compute all contributions to HVP with an overall uncertainty at the few-permille level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Specifying Calibration of Energy-Measuring Equipment

A report on calibrating energy-measuring equipment to maximize energy efficiency of lighting and other systems. The report describes best practices for accrediting calibration laboratories and for calibrating measuring equipment, compares and contrasts service providers accredited for energy-measuring equipment calibration, presents a tailorable specification template for requesting such calibration, and offers recommendations to a range of stakeholders.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Light sterile neutrinos, left-right symmetry, and 0νββ decay

We investigate neutrinoless double beta (0νββ) decay rates in minimal left-right symmetric models in presence of relatively light right-handed neutrinos. By use of an effective field theory approach, we systematically include all contributions in the model as well as the dependence of the decay amplitude on the masses of right-handed neutrinos. In type-I and type-II seesaw scenarios, we analyze the impact of right-handed neutrinos heavier than about 10 MeV, showing that this effect can lead to a detection of 0νββ decay in the next-generation experiments even for the normal hierarchy and a relatively large right-handed scale set by the mass of hypothetical right-handed gauge bosons. Finally, we comment on a possible connection between light right-handed neutrinos and the strong CP problem.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Update of Euclidean windows of the hadronic vacuum polarization

We compute the standard Euclidean window of the hadronic vacuum polarization using multiple independent blinded analyses. We improve the continuum and infinite-volume extrapolations of the dominant quark-connected light-quark isospin-symmetric contribution and address additional subleading systematic effects from sea-charm quarks and residual chiral-symmetry breaking from first principles. We find 𝑎$^{W}_{μ}$ = 235.56⁢(65)⁢(50) × 10 −10 , which is in 3.8⁢𝜎 tension with the recently published dispersive result of 𝑎$^{W}_{μ}$ =229.4⁢(1.4) × 10 −10 [G. Colangelo, A. X. El-Khadra, M. Hoferichter, A. Keshavarzi, C. Lehner, P. Stoffer, and T. Teubner, Phys. Lett. B 833, 137313 (2022)] and in agreement with other recent lattice determinations. We also provide a result for the standard short-distance window. The results reported here are unchanged compared to our presentation at the Edinburgh workshop of the g-2 Theory Initiative in 2022 [C. Lehner, Talk Presented at the 5th Plenary Meeting of the g-2 Theory Initiative in Edinburgh (2022)].

Lattice QCD↗

Specifying Calibration of Energy-Measuring Equipment

Instruments and standards need to be calibrated periodically to ensure that their use yields accurate measurements. Calibration needs, however, vary in sophistication, based on user expectations. This white paper reviews calibration terminology and standards, and describes best practices that have been developed for a) calibrating measurement equipment to ensure some known level of accuracy, and b) accrediting calibration service providers. Calibration is discussed in the context of metrological traceability, and excerpts from laboratory scopes of accreditation are shared to reveal the diversity of terminology and format among them. In an effort to aid those who currently calibrate measuring equipment or who have new or changing needs for calibrating measuring equipment, rationale is provided for why a specification might be used to request calibration services that meet specific test needs. Given the growing interest in using data to manage the energy consumption of systems, and the increasing number and variety of systems (e.g., building, computing) that can report such information, use cases requiring energy data are used to facilitate further discussion and provide examples. Commercially available service providers who are accredited for energy-measuring equipment calibration are compared and contrasted, and a specification template that might be used for requesting this calibration is presented. The specification template should be tailored to meet each user’s needs. To illustrate, an example set of energy-measuring-equipment test conditions (reflecting the planned usage of the device to be calibrated) is used to develop a customized calibration specification, and commercially available service providers are assessed in terms of their qualifications for calibration to that particular implementation of the specification template.

47 OTHER INSTRUMENTATION↗

System and method for monitoring atomic absorption during a surface modification process

A processing system monitors and/or controls a surface modification process occurring on a substrate within a processing chamber. An optical processing module having a light emission submodule to output a generated light signal and an optical detection submodule to detect a resultant light signal, is connected via fiber optic cables to light illuminating and light receiving components located within the chamber. A processor determines an amount of atomic absorption by an atomic element encountered by a probing beam passing between the illuminating and receiving components, based on the intensity of the generated light signal, the intensity of the received light signal and optionally the spontaneous emission of the atomic element in the absence of illumination by a probing beam. Based on the determined amount, the system derives a plurality of parameters of the modified substrate, their spatial and temporal uniformity, and information about process conditions in the processing chamber.

Atanasoff, George↗

Hadronic vacuum polarization of the muon on 2+1+1-flavor HISQ ensembles: an update

We give an update on the status of the Fermilab Lattice-HPQCD-MILC calculation of the contribution to the muon's anomolous magnetic moment from the light-quark, connected hadronic vacuum polarization. We present preliminary, blinded results in the intermediate window for this contribution, $a_{\mu, \textrm{W}}^{ll}$. The calculation is performed on $N_f =2+1+1$ highly-improved staggered quark (HISQ) ensembles from the MILC collaboration with physical pion mass at four lattice spacings between 0.15 fm and 0.06 fm. We also present preliminary results for a study of the two-pion contributions to the vector-current correlation function performed on the 0.15 fm ensemble where we see a factor of four improvement over traditional noise reduction techniques.

Lahert, Shaun↗

High performance, rapid thermal/UV curing epoxy resin for additive manufacturing of short and continuous carbon fiber epoxy composites

An additive manufacturing resin system includes a container; a build platform in the container; a build platform drive; an additive manufacturing resin that forms an additive manufacturing resin bath; an additive manufacturing print head; a build material supply connected to the additive manufacturing print head; an infill resin in the container, wherein the infill resin is supported by the additive manufacturing resin bath; a computer controller; and an extruded material that forms the product, wherein the infill resin at least partially surrounds the extruded material that forms the product. An infill resin supply provides the infill resin into the container and a control valve is connected to the infill resin supply. An IR light sensor is connected to the control valve and operatively connected to the infill resin in the container.

Lewicki, James↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Investigating feasible light configurations for fish restoration: an ethological insight

Light environment significantly impacts the effectiveness of fish population restoration in developed watersheds, subserving fish passage reconstruction in hydraulic complex and habitat rehabilitation. To develop an interior connection between light-related fish response from the laboratory and field fish conservation practice, we employed a new indexing system, consisting of phototaxis rate, relative swimming speed (RSS), and optic evasion coefficient (OEC), to quantify the light-induced behaviors in Ptychobarbus kaznakovi, a representative rare cyprinid in Tibet, China, at four experimental illuminance levels (15 lx, 30 lx, 60 lx, 120 lx) and four wavelengths (red, yellow, green, blue). The fish showed negative phototaxis at all given illuminances and wavelengths. Under red light, the OEC increased significantly from 0.642 at 15 lx to 0.782 at 30 lx (P = 0.029), while the RSS decreased significantly from 3.752 to 2.383 (P < 0.001). Behaviorally, the fish shifted from sprint to wandering around, indicating the alteration of dominant physiological activity from behavioral stress response to negative phototaxis. Under the green treatment, P. kaznakovi swam around quickly and presented slight negative phototaxis, and OEC values were uniform among all illuminances, probably because of the similarity of green light to the ambient color of the habitat. Accordingly, ecologists and fisheries practitioners can utilize red light to exclude fish from dangerous waters and green light to guide them to ideal habitats, laying the necessary groundwork for the light-driven fish recovery effort. Furthermore, the appropriate light configuration can yield economic benefits through the tradeoff among fish protection, power generation, and investment costs.

Lin, Chenyu↗

Calculating the QED correction to the hadronic vacuum polarisation on the lattice

Isospin-breaking corrections to the hadron vacuum polarization component of the anomalous magnetic moment of the muon are needed to ensure the theoretical precision of $g_\mu -2$ is below the experimental precision. We describe the status of our work calculating, using lattice QCD, the QED correction to the light and strange connected hadronic vacuum polarization in a Dashen scheme. We report results using physical $N_f=2+1+1$ HISQ ensembles at three lattice spacings and three heavier-than-light valence quark masses.

Ray, Gaurav↗

Energy Optimization of Light and Heavy-Duty Vehicle Cohorts of Mixed Connectivity, Automation and Propulsion System Capabilities via Meshed V2V-V2I and Expanded Data Sharing (Final Scientific and Technical Report)

Vehicle connectivity and automated driving technologies individually have the potential to decrease energy consumption and/or increase safety on light, medium or heavy duty vehicles to varying degrees depending on the traffic infrastructure and specific driving scenarios. Due to advances in sensing, perception and computing power, research and development emphasis in the mobility sector has shifted away from connectivity. Prior research has shown that driving automation with the absence of connectivity can in certain circumstances increase energy consumption. The effectiveness of synergizing connectivity and driving automation technologies is the focus of this work, specifically applied to vehicle cohorts of mixed composition, light and heavy duty, and powertrains ranging from all electric to conventional internal combustion engine. The project team is led by Michigan Technological University (MTU) and partnered with AVL Mobility Technologies Inc. (AVL), Borg Warner (BW), Traffic Technology Services (TTS), American Center for Mobility (ACM) and Navistar (NAV). The main thrusts for the team are to develop a micro-traffic simulation environment with specific VD&PT system attributes and CAV capabilities, 2) field a vehicle test fleet of mixed classification, propulsion and CAV capacity, 3) develop artificial intelligence (AI) and machine learning (ML) based multi-agent optimization methods for various traffic infrastructures, 4) integrate the virtual environment and the optimization methods then deploy the system as a CAV hardware in the loop (HiL) for the vehicle test fleet and 5) conduct closed track and public road testing to validate simulation and demonstrated energy and mobility improvements at multiple scales. For a cohort of mixed vehicles, the team will demonstrate a reduction of energy consumption of 10-50% at intersection, arterial roadway and limited access highway scenarios through connectivity and automation in simulation and at a closed test track. The energy reduction objectives of the project are summarized in Table 1, indicating the infrastructure and over what distances are relevant considered. Single scenario energy reductions are not relevant and thus, the research team took the approach to vary parameters associated with the infrastructure, vehicle cohort composition and dynamic behavior to generate energy consumption distributions for both unconnected and connected scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Systems and methods of adaptive two-wavelength single-camera imaging thermography (ATSIT) for accurate and smart in-situ process temperature measurement during metal additive manufacturing

A two-wavelength, single-camera imaging thermography system for in-situ temperature measurement of a target, comprising: a target light path inlet conduit for receiving a target light beam reflected from the target; a beam splitter installed in a splitter housing at a distal end of the target light path conduit, wherein the beam splitter divides the target light beam into a first light beam and a second light beam; a first light path conduit emanating from the splitter housing comprising a first aperture iris installed within the first light path conduit for aligning the first light beam; a first band pass filter installed within the first light path conduit for regulating the first light beam to a first wavelength λ1 and an optional half waveplate installed within the first light path conduit to modulate a polarization ratio of the first light beam of λ1 wavelength; a second light path conduit emanating from the splitter housing comprising a second aperture iris installed within the second light path conduit for aligning the second light beam; a second band pass filter installed within the second light path conduit for regulating the second light beam to a second wavelength λ2; a junction housing, wherein distal ends of each of the first and second light path conduits are connected to the junction housing; a polarizing beam splitter installed in the junction housing, wherein the polarizing beam splitter reflects the first light beam of λ1 wavelength along the same path or a parallel path of the second light beam of λ2 wavelength that passes directly through the polarizing beam splitter unreflected to create a merged light beam comprising light of λ1 and λ2 wavelengths; and a light path outlet conduit connected to the junction for directing the merged beam to a high-speed camera for imaging.

Zhao, Xiayun↗