Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “congestion control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Privacy-Preserving Transactive Energy System

In this paper, the privacy issue of recently proposed transactive energy systems for electric power systems is studied for the first time. It is identified that the private information of individual market participants is subject to the risk of leakage during their market-based interaction. In order to protect their privacy, a homomorphic encryption-based approach is developed to achieve the privacy preservation with the Paillier encryption scheme. The proposed privacy-perserving design is then demonstrated on a transactive energy system that coordinates and controls residential air conditioners to manage the feeder congestion. The simulation results confirm the effectiveness of the proposed design in protecting the privacy of individual market participants without affecting the overall system performance. Future work on the proposed design is also suggested.

Lu, Yang↗

A Vision–based Robust $\mathcal{H}$ ∞ Gain Scheduling Longitudinal and Lateral Following Controller for Autonomous Vehicles on Urban Curved Roads

Implementing advanced driver assistance systems (ADAS) in congested and intricate urban traffic scenarios poses significant challenges. To address the frequent stop–and–go motions exhibited by autonomous vehicles (AVs) navigating urban roads with changes in curvature, we propose a vision–based robust $\mathcal{H}$ ∞ adaptive cruise control system (ACC) for longitudinal control, plus a lane keeping assist system (LKAS) for lateral control. For the vision-based ACC, a weighted probability objective function for the vehicle following behavior is formulated. We incorporate $\mathcal{H}$ ∞ performance and gain scheduling techniques to mitigate the impact of uncertainty in visual sensor measurements. Furthermore, the optimal time headway is scheduled based on the velocity to ensure traffic flow efficiency and safety during the vehicle following process. For the LKAS, we introduce a road curvature estimation method that integrates lane and vehicle dynamics information to obtain the lateral and heading offsets. Next, the design criterion of the observer–based robust gain scheduling lateral motion controller is established by linear matrix inequality (LMI). Here, a series of experiments conducted within a camera–in–loop platform validate the proposed method.

33 ADVANCED PROPULSION SYSTEMS↗

Multiscale Control of Generic Second Order Traffic Models by Driver-Assist Vehicles

We study the derivation of generic high order macroscopic traffic models from a follow-the-leader particle description via a kinetic approach. First, we recover a third order traffic model as the hydrodynamic limit of an Enskog-type kinetic equation. Next, we introduce in the vehicle interactions a binary control modeling the automatic feedback provided by driver-assist vehicles and we upscale such a new particle description by means of another Enskog-based hydrodynamic limit. The resulting macroscopic model is now a generic second order model (GSOM), which contains in turn a control term inherited from the microscopic interactions. We show that such a control may be chosen so as to optimize global traffic trends, such as the vehicle flux or the road congestion, constrained by the GSOM dynamics. By means of numerical simulations, we investigate the effect of this control hierarchy in some specific case studies, which exemplify the multiscale path from the vehiclewise implementation of a driver-assist control to its optimal hydrodynamic design.

GSOM↗

Series FACTS Devices for Increasing Resiliency in Severe Weather Conditions

Severe weather conditions are low-probability, high-impact events that affect grid operations. The majority of power outages are caused by severe weather conditions. Grid resiliency to weather events can be enhanced by decreasing the reliance on its affected sections. One way to do this is to reduce the power flow through lines vulnerable to severe weather. If a line is disconnected, its initial power flow is distributed through the neighbor lines, which may cause congestion in the grid. FACTS devices can be used to control the power flow of lines that have a higher chance of power outages. Most previous works do not consider weather events in power flow control. In this work, a linearized optimal power flow (OPF)–based algorithm is developed to minimize the real power flow of vulnerable lines considering the thermal limits of lines to prevent infeasible solutions; the simulation is fast, making it suitable for large-scale systems. The proposed optimization problem is presented as a mixed-integer linear program (MILP), making it capable of using short-term load forecasting due to its high solution speed. The proposed optimization problem considers multiple lines with different outage probabilities and the uncertainties of the weather forecast. Moreover, it estimates the power reduction in vulnerable lines due to changes in the series FACTS devices. The performance of the proposed optimization problem is tested on IEEE 14-, 30-, and 118-bus systems for several scenarios. The results are validated with the AC power flow results from MATPOWER.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Novel Deep Reinforcement Learning Approach to Traffic Signal Control with Connected Vehicles

The advent of connected vehicle (CV) technology offers new possibilities for a revolution in future transportation systems. With the availability of real-time traffic data from CVs, it is possible to more effectively optimize traffic signals to reduce congestion, increase fuel efficiency, and enhance road safety. The success of CV-based signal control depends on an accurate and computationally efficient model that accounts for the stochastic and nonlinear nature of the traffic flow. Without the necessity of prior knowledge of the traffic system’s model architecture, reinforcement learning (RL) is a promising tool to acquire the control policy through observing the transition of the traffic states. In this paper, we propose a novel data-driven traffic signal control method that leverages the latest in deep learning and reinforcement learning techniques. By incorporating a compressed representation of the traffic states, the proposed method overcomes the limitations of the existing methods in defining the action space to include more practical and flexible signal phases. The simulation results demonstrate the convergence and robust performance of the proposed method against several existing benchmark methods in terms of average vehicle speeds, queue length, wait time, and traffic density.

42 ENGINEERING↗

Optimal Droop Setting for Congestion Reduction in a 100% Grid-Forming Inverter-based Power System

he high penetration of inverter-based resources (IBRs) introduces new challenges to power systems due to the complex inverter control. However, IBRs can be configured to maximize their benefits to improve system resilience and reliability. This paper proposes a steady-state optimization model that aims to mitigate transmission congestion in a 100% grid- forming (GFM) IBR-based power system. This goal is achieved by determining the optimal droop settings for the GFM IBRs under different congestion conditions due to renewable energy and load variations. The numerical solution is rigorously verified by a high-fidelity model of the IEEE 39-bus test system with detailed GFM IBR control in the time-domain electromagnetic transient (EMT) simulation tool PSCAD. The numerical solution and simulation results show a significant congestion reduction while meeting all other operating requirements. It is also observed that the numerical solving time is substantially less compared to the EMT simulation time.

Nguyen, Quan H.↗

Local enhancement in transient absorption spectroscopy by gating the resonance in the time domain

The concept of resonant perfect absorption, enabled by the combined action of pulse propagation and an auxiliary gate pulse, was recently proposed and demonstrated in a group of two-level systems [Y. He , ]. Here we exploit this method in a more realistic scenario by solving the coupled time-dependent Schrödinger equation and the Maxwell wave equation in helium. Through emptying the population of the 1 s 2 p excited state after its excitation, we explore the evolution of the spectral profile with time delay and propagation distance and link the observations to the controlled interference between the original field and the gated new field. We find that resonant absorption for higher-lying states can also be strongly enhanced, in spite of the congestion of multiple resonances and the presence of complex laser-induced couplings. Our results show that interferometric control of absorption using intense laser fields can be applied selectively in both the temporal and spatial domains. Published by the American Physical Society 2024

He, Yu (ORCID:0000000152120176)↗

Design, Deployment, and Characterization of the World’s First Flexible Large Power Transformer

GE Research and its partner Prolec GE have designed, built and deployed in the field the world’s first flexible power transformer. The flexible power transformer is a transmission class 3-phase autotransformer configurable in impedance and in voltage which allows it to serve as a universal spare for multiple units in a given fleet. However, the key innovation in this new concept is the online adjustable leakage impedance which allows the transformer to change its impedance without interrupting the transmission line operation. The flexible power transformer can be designed with up to three low voltage transmission class ratings and up to 12 impedance values changeable both online and offline. This report provides an overview of the design, manufacturing, testing, and commissioning of the 165kV, 60MVA prototype built including the results of the field performance validation tests. The prototype was specified in collaboration with Cooperative Energy, the utility host. It was designed and tested in the factory according to IEEE standard C57.12.00 and followed all protocols for transportation, installation, and commissioning of a power transformer. In addition to the prototype, a flexible protection system capable of automatically adjusting its settings upon the transformer impedance was also developed and deployed in the for testing and validation. On September 3, 2021 the prototype was energized in Cooperative Energy’s substation in Columbia, Mississippi to become the world’s first flexible power transformer in operation. Its performances and impact on the grid operation were demonstrated through different field tests. Results obtained confirm that the impedance of the flexible transformer can be varied under load through its full range, from 4.3% to 9.3%, without adverse impacts on the line operation, the protection system, the transformer stability and health condition. Results also proved that the flexible transformer is very effective in controlling power transfer through the line or load sharing between units operating in parallel. Indeed, it was proven that higher impedances decrease the thruput power of the transformer while lower impedances increase it. Up to 26MW was controllable on a line loading of 45MVA. It was also possible to demonstrate that the variation of the transformer impedance has no effect on the circulating current between units in parallel, except a minor transient during the impedance change. It was also proven that the flexible protection relay can update its protection settings automatically when the impedance change was detected. The prototype has operated continuously for more than 12 months now with a peak load exceeding 50MVA corresponding to >80% of its ONAN power rating. No alarm, trip or sign of failure has been reported by the utility. In addition to the development and deployment of the flexible transformer prototype, investigations were carried out on new nanodielectric fluids to replace the mineral oil used in power transformers with the goal of reducing their footprint and weight. The key parameters that were targeted for improvement included the breakdown voltage to reduce clearances between windings and tank hence the footprint; viscosity and thermal conductivity to increase the cooling efficiency and therefore to reduce the winding material. Several nanodielectric mixtures with mineral oil including with alumina (Al2O3), titania (TiO2) and Borum Nitrate (BN) with different surfactants have been analyzed and tested. Unfortunately, despite encouraging results no nanofluid candidate has been found viable to replace mineral oil. With the formulations tested, breakdown voltages are generally similar to mineral oil at lower particle contents and worse at higher particle contents. Viscosity appreciably increased at particles concertation over 2 wt% and thermal conductivity increased slightly at 5wt% and appears to be 10-15% higher at 10 wt% particle content. It is recommended to continue investigations to find solutions that can help increase the power density of future flexible power transformers. Flexible power transformers can significantly help the future power grid by providing more flexibility and resiliency. Indeed, by providing voltage and impedance flexibility, flexible power transformers reduce the need for multiple spares, hence inventory costs for utilities. With their online controllable impedance, they can provide support to the grid and help manage short-circuit currents, power flow, line congestion, and grid stability which will become more important with higher penetrations of intermittent renewable resources. During the field validation tests, it was demonstrated that up to 26MW was controllable on a line loading of 45MVA when the transformer impedance was varied from its minimum to its maximum range. Also, with the impedance range, the short-circuit currents could be reduced by up to 38% at the load side of the transformer. With its controllable impedance, flexible transformers can be used in future strategies of grid resilience to help better prepare the grid to face forecasted severe events including storms, heat waves and contingencies. The flexible power transformers can also find role in other applications including high voltage transmission cables such as offshore wind farms where solutions for energizing the cables and managing the reactive power are of critical importance. The designed flexible power transformer is now fully validated and ready for commercialization. Further analysis on the benefits of flexible power transformers for grid stability and short-circuit management including current limiting capability, reclosure and line restoration, control of inrush current, sizing of flexible AC components (FACTS) would help its rapid adoption by the industry.

24 POWER TRANSMISSION AND DISTRIBUTION↗

"Designing, simulating, and performing the 100-AV field test for the CIRCLES consortium: Methodology and Implementation of the Largest mobile traffic control experiment to date"

Previous controlled experiments on single-lane ring roads have shown that a single partially autonomous vehicle (AV) can effectively mitigate traffic waves. This naturally prompts the question of how these findings can be generalized to field operational, high-density traffic conditions. To address this question, the Congestion Impacts Reduction via CAV-in-the-loop Lagrangian Energy Smoothing (CIRCLES) Consortium conducted MegaVanderTest (MVT), a live traffic control experiment involving 100 vehicles near Nashville, TN, USA. This article is a tutorial for developing analytical and simulation-based tools essential for designing and executing a live traffic control experiment like the MVT. It presents an overview of the proposed roadmap and various procedures used in designing, monitoring, and conducting the MVT, which is the largest mobile traffic control experiment at the time. The design process is aimed at evaluating the impact of the CIRCLES AVs on surrounding traffic. The article discusses the agent-based traffic simulation framework created for this evaluation. A novel methodological framework is introduced to calibrate this microsimulation, aiming to accurately capture traffic dynamics and assess the impact of adding 100 vehicles to existing traffic. The calibration model's effectiveness is verified using data from a six-mile section of Nashville's I-24 highway. The results indicate that the proposed model establishes an effective feedback loop between the optimizer and the simulator, thereby calibrating flow and speed with different spatiotemporal characteristics to minimize the error between simulated and real-world data. Finally, We simulate AVs in multiple scenarios to assess their effect on traffic congestion. This evaluation validates the AV routes, thereby contributing to the execution of a safe and successful live traffic control experiment via AVs.

Ameli, Mostafa↗

Cooperative Merging via Online Speed Replanning: A Model-Free Approach With Vehicle-to-Vehicle Communication Packet Drop Compensation

On-ramp merging is a critical bottleneck in freeway traffic flow, contributing to congestion, accidents, and excessive fuel consumption. Although traditional ramp metering provides macroscopic control, it lacks the granularity for optimizing an individual vehicle’s trajectory. Cooperative merging, enabled by connected and automated vehicles, can potentially enhance traffic efficiency, safety, and fuel economy. However, existing research often neglects the influence of heterogeneous vehicle dynamics, unreliable vehicle-to-vehicle (V2V) communication, and real-time implementation challenges. Here, this paper introduces novel model-free online speed planners for cooperative on-ramp merging. The planners address these limitations by being agnostic to vehicle dynamics, effectively compensating for V2V communication packet drops and incurring only a light computational burden. Comprehensive evaluation, conducted on a real-time traffic-vehicle-communication co-simulation platform integrating high-fidelity vehicle dynamics, a traffic simulator, and recorded V2V communication footprints, demonstrates the effectiveness of the proposed speed planners. Simulation results reveal that the proposed method yields accurate tracking of desired speed and inter-vehicle distance, maintaining low fuel consumption even under high packet drop ratios, and demonstrating real-time implementation efficiency.

Wang, Zejiang [Univ. of Texas at Dallas, Richardso↗

Optimal Control of Differentially Private EV Charging: A Scalable Learning Approach Under Uncertainty

Internet of Things (IoT)-enabled electric vehicles (IoEVs) enable intelligent charging coordination that accounts for grid congestion. However, increased data exchange raises privacy concerns, as charging patterns can reveal sensitive driver behavior to grid operators. Here, we propose a differentially private (DP) EV charging framework that enables coordinated control while protecting driver data with theoretical privacy guarantees. Nevertheless, integrating DP inevitably introduces uncertainty into the control strategy for EVs, which can lead to infeasible solutions. To tackle this challenge, we develop a feasible and scalable control algorithm based on constrained reinforcement learning (CRL) and convex hulls. While our framework is designed to handle the uncertainty introduced by DP, it is general and also applicable to other sources of uncertainty in EV charging, such as the stochastic nature of driver behavior and renewable variability. This ensures feasible and privacy-preserving coordination of EV charging at scale. Our method constructs convex hulls within the action space to guarantee feasibility under stochastic constraints and incorporates constraint reduction techniques to improve scalability. Case studies based on IEEE benchmark systems demonstrate that the proposed approach effectively balances feasibility under uncertainty, scalability, and privacy in large-scale EV charging control.

Engineering - Power transmission and distribution↗

Load Shed Recovery With Transmission Switching and Intentional Islanding Methods After (N-2) Line Contingencies

Changing power system configuration may result in load shed recovery (LSR) because topology change can provide power flow control in meshed network. Some topologies may favor generation redispatch as compared to others and can eliminate line congestion which leads to LSR. One of the known methods for topology change is called transmission switching (TS) and research conducted in the past showed that TS is an effective means of mitigating load shedding. Another method of topology control is intentional islanding (IIS). In this manuscript, we explore IIS as a potential solution for LSR. IIS based on generator coherency has been presented in literature for mitigating cascading failures. However, IIS has not been explored solely as a LSR mechanism. In this paper, we compare the LSR based on IIS with well known LSR algorithm based on TS. The comparison is performed for IEEE 39-bus system and IEEE 118- bus system. The results show that IIS has a potential to perform better than TS in terms of computational efficiency and LSR.

42 ENGINEERING↗

Implementation and Operation of Power Flow Control Solutions for Transmission Systems

Power-flow controls (PFCs) technologies provide a suite of alternatives to more-efficiently direct the flow of power on the grid, improving flexibility and enabling the grid to be more responsive and resilient. PFCs can be used in many cases to mitigate overloads and consequently defer the installation of grid-expansion projects. They can also be suitable options in situations where new transmission lines cannot be built because of environmental constraints, land use, or other types of restrictions. Other uses include mitigation of loop or unintended flows, forcing of contractual or scheduled flows, reduction of congestion, and mitigation solutions during large maintenance or construction projects. While many studies have demonstrated the potential economic benefits of PFC for different types of applications, the implementation implications of using multiple PFCs for system operation and reliability have not been analyzed in detail. The lack of information and practical experience on these aspects hinders adoption of this technology. One use case would be that multiple PFCs are required to coordinate congestion management. In such cases, multiple PFCs are deployed in a meshed power system to control power flows across a wide area. The challenges are associated with PFC interaction—namely, the self and mutual power-flow sensitivity of each PFC, which must be accounted for in the calculation of the respective operating setpoints. This report analyzes implementation and operation that must be considered in evaluating transmission solutions using PFCs. The report first analyzes attributes with which PFC-based solutions should comply, based on the objective and characteristics of each particular use case. It then describes different approaches for coordinated control of multiple PFC devices for different applications, including options to avoid adverse interactions and reduce risks due to inappropriate coordination. Control and operation are illustrated through case studies performed on both generic and actual power system models. This report provides insights for transmission planners and operation engineers about the implementation of PFC-based transmission solutions; consequently, it will help them make informed decisions about the adoption of the technology.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Potential of Data Center Controls in Grid Services

The rapid proliferation of large data centers brings both challenges and opportunities for grid reliability. The data center resources and their potential flexibility have the potential to contribute resources to grid operations. Through capabilities like energy shifting and resource coordination, data centers can help reduce their net demand on the transmission network, as well as provide additional grid services to support reliable operation on the grid. While transient and long-term grid planning and operations are the scenarios that draw most attention, the quasi-steady state timeseries (QSTS) operation of data centers and grid bring interesting scenarios that can help evaluate the data center controls to aid grid services. This work is focused on modeling data centers for QSTS applications – incorporating the AI data center load profiles and building on the PNNL digital twin model for the thermal management loads to enable simulation studies to reveal the impact of data center controls on grid performance. This includes the integration of a QSTS battery and natural gas generator model to incorporate local resource impacts to the system. The simulation study is performed with a modified IEEE 24-Bus transmission system. Scenarios are focused on evaluating the data center load impacts on the transmission system and leveraging both data center and local generation controls to mitigate those impacts and provide additional grid services. The data center controls revealed the ability to contribute to two main kinds of grid services: preventing congestion on a weak grid by coordinating the data center resources with the collocated BESS and onsite generation; and the ability to help the grid operations during stressed times of operation like during a contingency. Leveraging these and other capabilities has the potential to help data centers become grid responsive assets, aiding in both their integration into the power system and grid reliability.

power grid simulation↗

Mitigating Traffic Congestion Through Visual Cues: Advancing Transportation Safety and Efficiency

While humans have an innate ability to estimate speed and distance, this capability is inherently imprecise. This imprecision has significant implications for traffic systems, which are highly sensitive to fluctuations in movement. Even small variations in velocity and following distances between travelers can create congestion in high-traffic environments. The absence of an effective and widely adopted solution creates significant transportation inefficiency. However, emerging technologies offer promising ways to help mitigate this issue. This paper will analyze the effectiveness of visual cues in reducing traffic congestion. Specifically, this paper presents an experiment using addressable LEDs to evaluate their effectiveness in influencing pedestrian behavior. These programmable lights enable individual control over each LED in a strip, allowing for dynamic lighting effects that serve as useful visual cues. The goal of this paper is to demonstrate that visual cues, such as addressable LED guidance, can effectively influence traveler behavior and contribute to reducing traffic congestion.

33 ADVANCED PROPULSION SYSTEMS↗

Non-unimodal and non-concave relationships in the network Macroscopic Fundamental Diagram caused by hierarchical streets

Unimodal, concave relationships between average network productivity and accumulation or density aggregated across spatially compact regions of urban networks—so called network Macroscopic Fundamental Diagrams (MFDs)—have recently been shown to exist on homogeneous street networks. When present, MFD relationships facilitate the modeling of traffic congestion at a regional level and have led to the development of various regional traffic control strategies. However, real street networks are not homogeneous—they generally have a hierarchical structure where some streets (e.g., arterials) promote higher mobility than others (e.g., local roads). Here, this paper examines how the presence of hierarchical roadway structures may potentially cause non-unimodal patterns in a network's MFD. These are observed using three types of tools: analytical models of simple network structures, simulations of various idealized roadway networks, and empirical data. The impacts of street hierarchy depend on how vehicles use different roadway types to move within the network; i.e., their routing strategy. The findings suggest that the presence of roadway hierarchies may lead to MFDs that have non-unimodal or non-concave patterns on the free-flow branch when vehicles route themselves according to user equilibrium principles, which is closest to what would be observed in realistic situations. Such patterns are contrary to what is traditionally assumed in most MFD-based modeling frameworks. However, the unimodal and concave MFD should be expected under system optimal routing conditions that maximize network productivity for a given traffic state.

42 ENGINEERING↗

Grid impact analysis using controller-hardware-in-the-loop for high-power vehicle charging stations

A controller-hardware-in-the-loop (CHIL) architecture for the evaluation of grid impacts arising from high-power vehicle charging stations is presented in this paper. Unlike simulation-based studies, the proposed method can be used to capture the interactions of the grid and the charging load along with charger controllers in real time. The proposed method can be used to evaluate the impact of charging load on the grid in terms of voltage variations and line congestion. The proposed CHIL platform allows for de-risking the vehicle charging station deployment by simulating the complex interactions among all the components of a vehicle charging station - i.e., the grid, vehicle, and charger controller - in a realistic manner before using the charging station in a grid. Further, the proposed CHIL approach can be used to evaluate the voltage regulation causalities of the vehicle charging station. Experimental results are presented in the paper to illustrate the applicability of the proposed method in a laboratory environment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Immediate effects of acute Mars mission equivalent doses of SEP and GCR radiation on the murine gastrointestinal system-protective effects of curcumin-loaded nanolipoprotein particles (cNLPs)

Introduction: Missions beyond low Earth orbit (LEO) will expose astronauts to ionizing radiation (IR) in the form of solar energetic particles (SEP) and galactic cosmic rays (GCR) including high atomic number and energy (HZE) nuclei. The gastrointestinal (GI) system is documented to be highly radiosensitive with even relatively low dose IR exposures capable of inducing mucosal lesions and disrupting epithelial barrier function. IR is also an established risk factor for colorectal cancer (CRC) with several studies examining long-term GI effects of SEP/GCR exposure using tumor-prone APC mouse models. Studies of acute short-term effects of modeled space radiation exposures in wildtype mouse models are more limited and necessary to better define charged particle- induced GI pathologies and test novel medical countermeasures (MCMs) to promote astronaut safety. Methods: In this study, we performed ground-based studies where male and female C57BL/6J mice were exposed to γ-rays, 50 MeV protons, or 1 GeV/n Fe-56 ions at the NASA Space Radiation Laboratory (NSRL) with histology and immunohistochemistry endpoints measured in the first 24 h post-irradiation to define immediate SEP/GCR-induced GI alterations. Results: Our data show that unlike matched γ-ray controls, acute exposures to protons and iron ions disrupts intestinal function and induces mucosal lesions, vascular congestion, epithelial barrier breakdown, and marked enlargement of mucosa-associated lymphoid tissue. We also measured kinetics of DNA double-strand break (DSB) repair using gamma-H2AX- specific antibodies and apoptosis via TUNEL labeling, noting the induction and disappearance of extranuclear cytoplasmic DNA marked by gamma-H2AX only in the charged particle-irradiated samples. We show that 18 h pre-treatment with curcumin-loaded nanolipoprotein particles (cNLPs) delivered via IV injection reduces DSB-associated foci levels and apoptosis and restore crypt villi lengths. Discussion: These data improve our understanding of physiological alterations in the GI tract immediately following exposures to modeled space radiations and demonstrates effectiveness of a promising space radiation MCM.

59 BASIC BIOLOGICAL SCIENCES↗