Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “condensation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Deepak Condenser Model (DeCoM)

Development of the DeCoM comes from the requirement of analyzing the performance of a condenser. A component of a loop heat pipe (LHP), the condenser, is interfaced with the radiator in order to reject heat. DeCoM simulates the condenser, with certain input parameters. Systems Improved Numerical Differencing Analyzer (SINDA), a thermal analysis software, calculates the adjoining component temperatures, based on the DeCoM parameters and interface temperatures to the radiator. Application of DeCoM is (at the time of this reporting) restricted to small-scale analysis, without the need for in-depth LHP component integrations. To efficiently develop a model to simulate the LHP condenser, DeCoM was developed to meet this purpose with least complexity. DeCoM is a single-condenser, single-pass simulator for analyzing its behavior. The analysis is done based on the interactions between condenser fluid, the wall, and the interface between the wall and the radiator. DeCoM is based on conservation of energy, two-phase equations, and flow equations. For two-phase, the Lockhart- Martinelli correlation has been used in order to calculate the convection value between fluid and wall. Software such as SINDA (for thermal analysis analysis) and Thermal Desktop (for modeling) are required. DeCoM also includes the ability to implement a condenser into a thermal model with the capability of understanding the code process and being edited to user-specific needs. DeCoM requires no license, and is an open-source code. Advantages to DeCoM include time dependency, reliability, and the ability for the user to view the code process and edit to their needs.

Patel, Deepak↗

Mars Atmospheric CO2 Condensation Above the North and South Poles as Revealed by Radio Occultation, Climate Sounder, and Laser Ranging Observations

We study the condensation of CO2 in Mars atmosphere using temperature profilesretrieved from radio occultation measurements from Mars Global Surveyor (MGS) as wellas the climate sounding instrument onboard the Mars Reconnaissance Orbiter (MRO),and detection of reflective clouds by the MGS Mars Orbiter Laser Altimeter (MOLA). Wefind 11 events in 1999 where MGS temperature profiles indicate CO2 condensation andMOLA simultaneously detects reflective clouds. We thus provide causal evidence thatMOLA non-ground returns are associated with CO2 condensation, which strongly indicatestheir nature being CO2 clouds. The MGS and MRO temperature profiles together revealthe seasonal expansion and shrinking of the area and the vertical extent of atmosphericsaturation. The occurrence rate of atmospheric saturation is maximized at high latitudes inthe middle of winter. The atmospheric saturation in the northern polar region exhibits moreintense seasonal variation than in the southern polar region. In particular, a shrinking ofsaturation area and thickness from LS 270 to 300 in 2007 is found; this is probablyrelated to a planet-encircling dust storm. Furthermore, we integrate the condensation areaand the condensation occurrence rate to estimate cumulative masses of CO2 condensatesdeposited onto the northern and southern seasonal polar caps. The precipitation flux isapproximated by the particle settling flux which is estimated using the impulse responses ofMOLA filter channels. With our approach, the total atmospheric condensation mass canbe estimated from these observational data sets with average particle size as the onlyfree parameter. By comparison with the seasonal polar cap masses inferred from thetime-varying gravity of Mars, our estimates indicate that the average condensate particleradius is 822 mm in the northern hemisphere and 413 mm in the southern hemisphere.Our multi-instrument data analysis provides new constraints on modeling the global climateof Mars.

MOLA↗

Switchable Wettability for Condensation Heat Transfer

Condensation proceeds as dropwise or filmwise depending on the wettability of the condensing surface. These two modes of condensation have disparate heat transfer coefficients, with dropwise often exceeding filmwise. This work reports a surface with switchable superhydrophilic to hydrophobic wetting behavior that can exhibit both modes of condensation. Relative to the highly-wetting state which yields filmwise condensation, the non-wetting state exhibits dropwise condensation and twice the heat transfer coefficient. Relevance to thermal management is additionally discussed.

Heat transfer↗

CFD Validation and Scaling of a Condenser Used in an ISRU Propellant Production System

This work develops a Computational Fluid Dynamics (CFD) model of a Commercial-Off-The-Shelf (COTS) condenser used for ground-based testing of an In-Situ Resource Utilization (ISRU) propellant production system. STAR-CCM+ was used to simulate water condensing through the condenser downstream of a methanation reactor. The computational data of the digital model is validated with test cases using nitrogen and water in ambient conditions. After validation with the test data, the digital model can be used to predict scale at higher production targets. The StarCCM+ simulation of the digital model shows good agreement with the test data provided. From the simulation, the condensation rate calculated was 18.3 g/hr and the process gas mass flow rate was 709.2 g/hr. The test data measured an average 16.9 g/hr condensation rate and 693.6 g/hr process gas mass flow rate. The simulation shows a 7.3% error in the water condensation and 2.2% error in the process gas at the outlet.

Condenser↗

Disequilibrium condensation environments in space - A frontier in thermodynamics

The thermal-disequilibrium aspect of the problem of dust-particle formation from a gas phase in an open space environment is discussed in an effort to draw attention to the space condensation environment as an interesting arena for application and extension of the ideas and formalisms of nonequilibrium thermodynamics. It is shown that quasi-steady states with a disequilibrium between the gas-phase kinetic temperature and the condensed-phase internal temperature appear to be the norm of condensation environments in space. Consideration of the case of condensation onto a bulk condensed phase indicates that these quasi-steady states may constitute Prigogine dissipative structures. It is suggested that a proper study of the process of condensation in a space environment should include any effects arising from thermal disequilibrium.

De, B. R.↗

Development of a condenser for the dual catalyst water recovery system

Conceptual evaporation/condensation systems suitable for integration with the catalytic water recovery method were evaluated. The primary requirements for each concept were its capability to operate under zero-gravity conditions, condense recovered water from a vapor-noncondensable gas mixture, and integrate with the catalytic system. Specific energy requirements were estimated for concepts meeting the primary requirements, and the concept most suitable for integration with the catalytic system was proposed. A three-man rate condenser capable of integration with the proposed system, condensing water vapor in presence of noncondensables and transferring the heat of condensation to feed urine was designed, fabricated, and tested. It was treated with steam/air mixtures at atmospheric and elevated pressures and integrated with an actual catalytic water recovery system. The condenser has a condensation efficiency exceeding 90% and heat transfer rate of approximately 85% of theoretical value at coolant temperature ranging from 7 to 80 deg C.

Budinikas, P.↗

Condensation modes in sheared magnetic fields

The present study of the condensation modes in coronal cylindrical plasmas, with attention to magnetic shear effects on stability, notes that such shear is insignificant in the initiation of condensation in the case of low beta coronal plasmas. The effects of magnetic field shear, twist, and strength on condensation modes differ, depending on the wave vector. The stability of condensation modes strongly depends on the choice of equilibrium temperature and density profiles. If plasma temperature increases with twist but density does not, condensation modes are unstable for low field twist; by contrast, if plasma density increases with twist but temperature does not, condensation modes are unstable for high twist.

An, C.-H.↗

Study of toluene rotary fluid management device and shear flow condenser performance for a space-based organic Rankine power system

Management of two-phase fluid and control of the heat transfer process in microgravity is a technical challenge that must be addressed for an orbital Organic Rankine Cycle (ORC) application. A test program was performed in 1-g that satisfactorily demonstrated the two-phase management capability of the rotating fluid management device (RFMD) and shear-flow condenser. Operational tests of the RFMD and shear flow condenser in adverse gravity orientations, confirmed that the centrifugal forces in the RFMD and the shear forces in the condenser were capable of overcoming gravity forces. In a microgravity environment, these same forces would not have to compete against gravity and would therefore be dominant. The specific test program covered the required operating range of the Space Station Solar Dynamic Rankine Cycle power system. Review of the test data verified that: fluid was pumped from the RFMD in all attitudes; subcooled states in the condenser were achieved; condensate was pushed uphill against gravity; and noncondensible gases were swept through the condenser.

Havens, Vance↗

Mathematical Modeling of Loop Heat Pipes with Multiple Capillary Pumps and Multiple Condensers: Stead State Stimulations - Part 1

Loop Heat Pipes (LHPs) have proven themselves as reliable and robust heat transport devices for spacecraft thermal control systems. So far, the LHPs in earth-orbit satellites perform very well as expected. Conventional LHPs usually consist of a single capillary pump for heat acquisition and a single condenser for heat rejection. Multiple pump/multiple condenser LHPs have shown to function very well in ground testing. Nevertheless, the test results of a dual pump/condenser LHP also revealed that the dual LHP behaved in a complicated manner due to the interaction between the pumps and condensers. Thus it is redundant to say that more research is needed before they are ready for 0-g deployment. One research area that perhaps compels immediate attention is the analytical modeling of LHPs, particularly the transient phenomena. Modeling a single pump/single condenser LHP is difficult enough. Only a handful of computer codes are available for both steady state and transient simulations of conventional LHPs. No previous effort was made to develop an analytical model (or even a complete theory) to predict the operational behavior of the multiple pump/multiple condenser LHP systems. The current research project offered a basic theory of the multiple pump/multiple condenser LHP operation. From it, a computer code was developed to predict the LHP saturation temperature in accordance with the system operating and environmental conditions.

Hoang, Triem T.↗

Calculated Condenser Performance for a Mercury-Turbine Power Plant for Aircraft

As part of an investigation af the application of nuclear energy to various types of power plants for aircraft, calculations have been made to determine the effect of several operating conditions on the performance of condensers for mercury-turbine power plants. The analysis covered 8 range of turbine-outlet pressures from 1 to 200 pounds per square inch absolute, turbine-inlet pressures from 300 to 700 pounds per square inch absolute,and a range of condenser cooling-air pressure drops, airplane flight speeds, and altitudes. The maximum load-carrying capacity (available for the nuclear reactor, working fluid, and cargo) of a mercury-turbine powered aircraft would be about half the gross weight of the airplane at a flight speed of 509 miles per hour and an altitude of 30,000 feet. This maximum is obtained with specific condenser frontal areas of 0.0063 square foot per net thrust horsepower with the condenser in a nacelle and 0.0060 square foot per net thrust horsepower with the condenser submerged in the wings (no external condenser drag) for a turbine-inlet pressure of 500 pounds per square inch absolute, a turbine-outlet pressure of 10 pounds per square inch absolute, and 8 turbine-inlet temperature of 1600 F.

Doyle, Ronald B.↗

Acoustic Insights into Flow Condensation Mechanisms

Two-phase thermal management systems, with both boiling and condensation processes, offer great potential and heat transfer coefficients that are orders of magnitude higher than traditional single-phase systems. However, two-phase flows can suffer from a wide range of interfacial instabilities leading to significant thermal performance degradation. In this study, we aim to detect regime transitions and characterize dominating physical mechanisms of flow condensation, such as turbulent diffusion in annular liquid film and interfacial waves, using an integrated system of acoustic, modal, and optical sensing techniques and thermofluidic characterizations. A wideband acoustic emissions sensor and high-sensitivity accelerometer are utilized to capture acoustic and vibrational signatures that signal the onset of liquid film formation and interfacial waves during flow pattern transitions. Compared to optical imaging, wideband acoustic emission sensing allows for higher sampling rates to capture high-frequency interface oscillations critical to the flow regime transitions and works well even for condensation in opaque tubes. Acoustic features (e.g., amplitude, frequency, energy, duration) are correlated with thermofluidic processes (e.g., capillary flows, turbulent flows, boiling, condensation). By relating thermal performance metrics with these dynamic signatures in acoustic and modal regimes, we explore the ability to probe and monitor critical flow regime transitions and transport efficiency in flow condensation.

Acoustic Modal Regimes↗

Geothermal steam condensate reinjection

Geothermal electric generating plants which use condensing turbines and generate and excess of condensed steam which must be disposed of are discussed. At the Geysers, California, the largest geothermal development in the world, this steam condensate has been reinjected into the steam reservoir since 1968. A total of 3,150,000,000 gallons of steam condensate has been reinjected since that time with no noticeable effect on the adjacent producing wells. Currently, 3,700,000 gallons/day from 412 MW of installed capacity are being injected into 5 wells. Reinjection has also proven to be a satisfactory method of disposing of geothermal condensate a Imperial Valley, California, and at the Valles Caldera, New Mexico.

Chasteen, A. J.↗

Condensation processes and the formation of cosmic grains

The case of condensation from a gas in the absence of any preexisting grains or nuclei upon which condensation can occur is considered. Some of the analysis is expected to apply to condensation on grains already present. An attempt is made to examine the basic assumptions of the various procedures used to describe condensation and to examine their applicability to astronomical systems. Attention is given to thermodynamic equilibration calculations, nucleation theory, kinetic mechanisms, the theoretical mechanisms, and condensation experiments.

Donn, B.↗

Concentrations of condensation nuclei in the vicinity of jetstream maxima

Ozone and condensation nuclei were measured on March 29, 1977 (and March 30, GMT) from a Sabreliner in a frontal zone south of Denver, Colo. The ozone served as a tracer for stratospheric air and the condensation nuclei as a tracer for tropospheric air. Both the Langer condensation nucleus counter and the Rich-100 counter can be used to measure condensation nucleus concentrations in the vicinity of the tropopause. However, the former counter is more sensitive to low concentrations. The nuclei measured were found to be almost entirely larger than 0.005 micron in radius, consisting of thousands of molecules. The mesostructure of the ozone and condensation nucleus concentrations agreed well with a double structure of the frontal zone that became apparent from a detailed analysis of radiosonde data.

Cadle, R. D.↗

The growth of filaments by the condensation of coronal arches

A model of filament formation based on the condensation of coronal arches is described. The condensation results from initiating the radiative instability within an arch by superimposing a transient energy supply upon the steady state heating mechanism. The transient energy supply increases the density within the arch so that when it is removed the radiative losses are sufficient to lead to cooling below the minimum in the power loss curve. Times from the initial formation of the condensation to its temperature stabilization as a cool filament have been calculated for various initial conditions. They lie in the range 10,000-100,000 s with the majority of the time spent above a temperature of 1 x 10 to the 6th K. Under the assumption that the condensation of a single arch forms an element of the filament, a complete filament requires the condensation of an arcade of loops. Using experimentally derived parameters, filament densities of 10 to the 11th to 10 to the 12th per cu cm can be obtained.

Davis, J. M.↗

Structure-to-glass transition temperature relationships in high temperature stable condensation polyimides

The presence of a hexafluoroisopropylidene (6F) connecting group in aryl dianhydrides used to prepare aromatic condensation polyimides provides high glass transition temperature (T sub g) polyimides with excellent thermo-oxidative stability. The purpose of this study was to determine if a trifluorophenyl-ethylidene (3F) connecting group would have a similar effect on the T sub g of aromatic condensation polyimides. A new dianhydride containing the 3F connecting group was synthesized. This dianhydride and an aromatic diamine also containing the 3F connecting group were used together and in various combinations with known diamines or known dianhydrides, respectively, to prepare new 3F containing condensation polyimides. Known polyimides, including some with the 6F connecting linkage, were also prepared for comparison purposes. The new 3F containing polymers and the comparison polymers were prepared by condensation polymerization via the traditional amic-acid polymerization method in N,N-dimethylacetamide solvent. The solutions were characterized by determining their inherent viscosities and then were thermally converted into polyimide films under nitrogen atmosphere at 300 to 500 C, usually 350 C. The T sub g's of the films and resin discs were then determined by thermomechanical analysis and were correlated as a function of the final processing temperatures of the films and resin discs. The results showed that similarities existed in the T sub g's depending on the nature of the connecting linkage in the monomers used to prepare the condensation polyimides.

Alston, W. B.↗

Condensation modes in magnetized plasmas

Condensation modes in magnetized cylindrical plasmas, with concentration on how magnetic field affects the stability were studied. It is found that the effects of magnetic field (shear, twist, and strength) on the condensation modes are different depending on the wave vector. For modes whose wave vector is not perpendicular to magnetic field lines the plasma motion is mainly along the field lines; the effects of magnetic field on the modes are negligible except on the heat flow parallel to the field line. For a mode which is localized near a surface where the wave vector is perpendicular to the field line, the plasma moves perpendicular to the line carrying the field line into the condensed region; magnetic field affects the mode by building up magnetic pressure in the condensed region. The stability of condensation modes strongly depends on how density and temperature vary with field twist. The stable nature of global quiescent prominence magnetic configurations implies that prominences form for low field twist for which ideal MHD modes are stable; plasma temperature should increase with field twist for stable prominence formation.

An, Chang-Hyuk↗

Condensation polyimides

Polyimides belong to a class of polymers known as polyheterocyclics. Unlike most other high temperature polymers, polyimides can be prepared from a variety of inexpensive monomers by several synthetic routes. The glass transition and crystalline melt temperature, thermooxidative stability, toughness, dielectric constant, coefficient of thermal expansion, chemical stability, mechanical performance, etc. of polyimides can be controlled within certain boundaries. This versatility has permitted the development of various forms of polyimides. These include adhesives, composite matrices, coatings, films, moldings, fibers, foams and membranes. Polyimides are synthesized through both condensation (step-polymerization) and addition (chain growth polymerization) routes. The precursor materials used in addition polyimides or imide oligomers are prepared by condensation method. High molecular weight polyimide made via polycondensation or step-growth polymerization is studied. The various synthetic routes to condensation polyimides, structure/property relationships of condensation polyimides and composite properties of condensation polyimides are all studied. The focus is on the synthesis and chemical structure/property relationships of polyimides with particular emphasis on materials for composite application.

Hergenrother, P. M.↗