Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “communication protocols”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Review of Design Elements within Power Infrastructure Cyber–Physical Test Beds as Threat Analysis Environments

Cyber–physical systems (CPSs) are an integral part of modern society; thus, enhancing these systems’ reliability and resilience is paramount. Cyber–physical testbeds (CPTs) are a safe way to test and explore the interplay between the cyber and physical domains and to cost-effectively enhance the reliability and resilience of CPSs. Here a review of CPT elements, broken down into physical components (simulators, emulators, and physical hardware), soft components (communication protocols, network timing protocols), and user interfaces (visualization-dashboard design considerations) is presented. Various methods used to validate CPS performance are reviewed and evaluated for potential applications in CPT performance validation. Last, initial simulated results for a CPT design, based on the IEEE 33 bus system, are presented, along with a brief discussion on how model-based testing and fault–injection-based testing (using scaling and ramp-type attacks) may be used to help validate CPT performance.

14 SOLAR ENERGY↗

FERC order 2222 & DER policy and implementation report - January 2026

The January 2026 FERC 2222 Tracker Report provides an overview of the progress and challenges in the implementation of FERC Order 2222, emphasizing the critical need for state-level action to address gaps in DERA/EDC communication protocols. The report highlights the importance of reliable communication between electric distribution companies (EDCs) and DER aggregators (DERAs) for seamless market operations, noting the absence of specific directives from FERC and RTO/ISO compliance filings. Key discussions include the operational coordination required to manage DER operations within aggregated markets, the potential use of tools like DER Registries for efficient data exchange, and the implications of non-performance due to communication issues. While steps are being taken at the state level, such as ongoing policy development and bi-monthly webinars for stakeholder education, no states have fully developed coordination frameworks as of early 2026. The report underscores the growing role of states and local regulators in defining these protocols and ensuring effective coordination amidst the complex dynamics of distributed energy resources (DERs) integration into wholesale markets.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Systems Engineering Analysis of National Ignition Facility Industrial Controls Systems and Safety Interlock Systems Remote Input/Output Networking Migration from ControlNet to EtherNet/IP

The ControlNet industrial communications protocol and modules used in the Industrial Control System (ICS) and Safety Interlock System (SIS) at the National Ignition Facility (NIF) are no longer necessary and the ICS and SIS would be better served by migrating the communications structure to use EtherNet/Industrial Protocol (IP) and EtherNet bridge modules instead. By the admission of the vendor of ControlNet hardware, Rockwell Automation, in literature by Bill Petro [1], “Moving forward, customers will be able to optimize their asset utilization better using EtherNet/IP protocol than with ControlNet.” The NIF is one of the key elements of the Inertial Confinement Fusion (ICF) program at Lawrence Livermore National Laboratory (LLNL), a federally funded research and development center (FFRDC). The NIF contains the systems and provides the operational capacity to perform ICF, high energy density (HED), and discovery science experiments utilizing 192 individual beamlines, a host of diagnostics, and all the industrial systems required to facilitate these beamlines and diagnostics. The industrial systems are governed by the ICS and SIS, with the ICS providing control and the SIS providing monitoring and permissives. Construction on the NIF began in 1997 and was certified complete in 2009 and, as a result, the ICS and SIS were developed during this time using the tools that were available then. This includes the communications structure and protocols for these systems, much of which was, and still is, ControlNet. ControlNet, particularly during the time that the ICS and SIS were being built, has several attractive features. ControlNet hardware is exclusive to Rockwell Automation, which was the automation hardware chosen for the ICS and SIS. One feature that could be considered an advantage or a disadvantage depending on the communication needs of the system is that ControlNet also utilizes no active network components, excluding repeaters which are not always necessary. According to the architect of the ICS system at the NIF, Gordon Lau, one of the most attractive features of the ControlNet protocol during development of the ICS and SIS was that it is deterministic, providing timing of data transfer that is executed exactly as it is defined by the developer.

42 ENGINEERING↗

Incremental Threshold Scheme Enabled IoT Group Key Management

Cyber landscape evolves rapidly. Internet of Things (IoT) and Edge Computing (EC) have rapidly become an integral part of the modern computing infrastructure. It is expected that there will be more than 50 billion active and connected IoT devices by 2025 [1]. Pervasive IoT/EC creates unprecedented opportunities bridging the gap between previously segregated cyber and physical spaces. However, this progress also brings along new security challenges. IoT devices typically have limited computation, communication, and storage resources. This leads to security architecture designs such as using symmetric keys for group communication. While secure and efficient in stable network settings, symmetric key solutions are ill-adapted for IoT's highly dynamic device mobility behavior and frequent group membership turnover. Whenever IoT members leave a group, the known symmetric keys cannot be made forgotten, posing a serious vulnerability. This leads to frequent re-groupings that require expensive re-authentication, key regeneration, and key redistribution in order to maintain IoT/EC security. We present a novel symmetric key management framework that integrate an Incremental Threshold Scheme (ITS) cryptographical function into communication protocol's key rotation mechanism to allow for secure and efficient symmetric key communication group member node revocation. This ITS-enabled key management framework alleviates the need of frequent and expensive re-grouping and re-keying needed by today's large and dynamic IoT/EC operations. We further applied this ITS-enabled key management framework to a distributed IoT/EC-integrated publish and subscribe framework for applicability validation.

Li, Mingyan↗

DDCP framework

DDCP protocol software 1.0 This repository contains the C++ implementation of version 1.x of the Distributed Data Communications Protocol (DDCP). DDCP provides request/reply, feature discovery, data transfer, control, interrupt, and transaction support for communicating with accelerator instrumentation over UDP. The standard server port is 65000. The framework is a source dependency for services that communicate directly with DDCP hardware. It is not a deployable service by itself.

Joshi, Shreya [Fermi National Accelerator Laborato↗

Cybersecurity Certification Recommendations for Interconnected Grid Edge Devices and Inverter Based Resources

Escalating deployment of PV and grid-edge devices on the distribution grid has increased the sustainability and efficiency of the electric grid. However, the increasing number of distributed energy resources (DERs) deployed creates a heightened cyber-physical interdependency on the distribution grid and thus creates more vectors for cyber-attacks to exploit through information and communication technology (ICT) systems and networks. For example, control signal packets can be modified, intercepted, or corrupted due to vulnerabilities in communication protocols used by microgrid controllers and grid edge devices for power control. Therefore, to mitigate and prevent cyber-attacks on grid edge devices and the inverter-based resources connected to the distribution grid, the U.S. Department of Solar Energy Technologies Office (SETO) awarded funding to the National Renewable Energy Laboratory and Sandia National Laboratory (SNL) to research, develop, and harmonize cybersecurity standards for Photovoltaic (PV) systems and for other kinds of DERs. To help develop a standard for DER cybersecurity, NREL established certification recommendations and test cases, in consensus with the solar industry and UL, for ensuring intrinsic design security for DERs. These recommendations were developed to bolster the cybersecure functionalities such as TLS, MAC, CRL, session resumption/renegotiation, and password, system, and service security management within the DER devices. The proposed test cases verify authentication, authorization, confidentiality, and data integrity for data and communications of DERs that use Transmission Control Protocol/Internet Protocol (TCP/IP). They were also developed to protect DER communications from eavesdropping, replay, man-in-the-middle, denial of service (DoS), spoofing through security certificates, least-privilege violation, and brute-force credentials. This report, which has been validated and reviewed by UL, expands upon those test cases to provide DER cybersecurity certification recommendations which increase DER resiliency and help to mitigate cyber-attacks. UL's collaboration with NREL and approval of this document will accelerate the adoption of a UL standard for DER cybersecurity.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-Time Hardware-in-the-Loop Distributed Energy Resources System Testbed using IEEE 2030.5 Standard

IEEE 2030.5 standard is drawing special attention among communication protocols for smart inverters and distributed energy resources (DER). Moreover, California Rule 21 mandates new DER must be ready to communicate to a host utility using the IEEE 2030.5 standard. Therefore, development of an effective real-time simulation method for managing DER using IEEE 2030.5 network is crucial. This paper presents a real-time hardware-in-the-loop (HIL) DER system testbed using the IEEE 2030.5 standard. The proposed real-time co-simulation testbed consists of a DER physical system simulation using OP AL-RT real-time simulator and a cyber system simulation including DER gateways and a DER management system (DERMS) cloud server. Custom-built client and server programs are developed to meet the compliant with IEEE 2030.5-2018 standard and implemented in the DER gateways and a DERMS server, respectively. Furthermore, the feasibility of the proposed testbed for DER systems is validated by experiments.

42 ENGINEERING↗

A Blockchain and PKI-Based Secure Vehicle-to-Vehicle Energy-Trading Protocol

With the increasing awareness for sustainable future and green energy, the demand for electric vehicles (EVs) is growing rapidly, thus placing immense pressure on the energy grid. To alleviate this, local trading between EVs should be encouraged. In this paper, we propose a blockchain and public key infrastructure (PKI)-based secure vehicle-to-vehicle (V2V) energy-trading protocol. A permissioned blockchain utilizing the proof of authority (PoA) consensus and smart contracts is used to securely store data. Encrypted communication is ensured through transport layer security (TLS), with PKI managing the necessary digital certificates and keys. A multi-leader, multi-follower Stackelberg game-based trade algorithm is formulated to determine the optimal energy demands, supplies, and prices. Finally, we propose a detailed communication protocol that ties all the components together, enabling smooth interaction between them. Key findings, such as system behavior and performance, scalability of the trade algorithm and the blockchain, smart contract execution costs, etc., are presented through numerical results by implementing and simulating the protocol in various scenarios. This work not only enhances local energy trading among EVs, encouraging efficient energy usage and reducing burden on the power grid, but also paves a way for future research in sustainable energy management.

Stackelberg game↗

Hardware-in-the-Loop Testing of Wide-Area Damping Controller for Field Implementation in Large-scale Power Grid

In our previous work, an adaptive measurement-driven wide-area damping controller (WADC) for suppressing inter-area oscillations has been proposed and a hardware prototype was developed and validated through hardware-in-the-loop tests. As a continuation of the work, this paper introduces a WADC software prototype to handle the realistic challenges for field implementation in the control room of the power grid. The WADC software is developed and operated as an openPDC adapter with a graphical user interface (GUI) to monitor the WADC inputs and output, the communication delays and other variables. The software prototype has been fully tested through an enhanced hardware-in-the-loop (HIL) test setup. Its performance is verified under various realistic communication uncertainties, such as random time delays and data losses, with different communication protocols. The experiment results have proven the WADC software can deliver sufficient damping to suppress the targeted oscillation mode in handling various communication uncertainties for future field deployment.

Jia, Xinlan↗

Redis-Based Streaming Architecture for Accelerator Beam Instrumentation DAQ Systems

The Fermilab Acceleraor Division, Beam Instrumentation Department, is always adopting modern and current software methodologies for complex DAQ architectures. This paper highlights the Redis Adapter (RA) as the key software component enabling high performance, modular communication between digitizers and distributed control systems by leveraging Redis and containerization. The RA provides a unified, efficient interface between Redis based data streams and consumer systems. In the legacy architecture, digitized data flowed through the custom, UDP based Distributed Data Communication Protocol in the middle layer. In the current system, DDCP remains the ingestion path, while the RA serves as the decoupling layer. The proposed system replaces old VME digitizers with a SOM-based digitizer that communicates with Redis using the RA. The RA acts as both a performance-critical bridge and a protocol-agnostic adapter, ensuring compatibility with legacy control frameworks while enabling future scalability and modularity. This restructuring of the middle layer also helps the system achieve high throughput, reduce latency, and simplify the data path. Finally, we will demonstrate how RA is utilized in our two core products to deliver both legacy compatibility and future flexibility.

Joshi, S. [Fermilab]↗

Studying impacts of communication system performance on dynamic stability of networked microgrid

The development of smart grid technologies has resulted in increased interdependence between power and communication systems. Many of the operations in the existing power system rely on a stable and secured communication system. For electrically weak systems and time‐critical applications, this reliance can be even greater, where a small degradation in communication performance can degrade system stability. However, despite inter‐dependencies between power and communication systems, only a few studies have investigated the impacts of communication system performance on power system dynamics. This study investigates the dependencies of power system dynamics operations on a communication system performance. First, a detailed, dynamic networked microgrid model is developed in the GridLAB‐D simulation environment, along with a representative multi‐traffic, multi‐channel, multi‐protocol communication system model, developed in the network simulator (ns‐3). Second, a hierarchical engine for large‐scale infrastructure co‐simulation framework is developed to co‐simulate microgrid dynamics, its communication system, and a microgrid control system. The impact of communication system delays on the dynamic stability of networked microgrids is evaluated for the loss of generation using three use‐cases. While the example use‐cases examine microgrid applications and the impact to resiliency, the framework can be applied to all levels of power system operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Timeouts Best Practices

This study investigates common timeouts encountered in the electric vehicle (EV) charging communications process. Many different timeouts are defined within the EV charging communications protocols. These timeouts can either be a fixed value or a defined range of values. In both cases, the timeout defines the duration of time for which one or both parties in the communications session are expected to wait for some action or process to complete before terminating the charge attempt. These timeout-based terminations are intended to prevent the charging process from becoming stuck indefinitely in any particular step. These terminations also enable a retry of the terminated charging session to begin. However, misaligned timeout values can have a significant negative impact on the user experience. Premature termination of charging sessions due to inappropriate timeout settings can lead to charging failures, causing inconvenience, wasted time, and frustration for users. These disruptions can degrade the overall user experience, making it essential to carefully manage and align timeout values with the relevant actions and processes to ensure reliable and satisfactory EV charging sessions. The core objective of this study is to boost reliability and enhance user experience by conducting a thorough review of timeout-based issues in EV charging and delivering a set of recommendations to modify these existing timeouts. These recommendations are informed by feedback gathered from multiple EV charging partners. This document is intended to inform electric vehicle supply equipment (EVSE) and EV manufacturers, EV charging infrastructure developers, and policymakers responsible for designing and implementing EV charging protocols and systems.

33 ADVANCED PROPULSION SYSTEMS↗

RX-ADS: Interpretable Anomaly Detection Using Adversarial ML for Electric Vehicle CAN Data

Recent year has brought considerable advancements in Electric Vehicles (EVs) and associated infrastructures/ communications. Intrusion Detection Systems (IDS) are widely deployed for anomaly detection in such critical infrastructures. This paper presents an Interpretable Anomaly Detection System (RX-ADS) for intrusion detection in CAN protocol communication in EVs. Contributions include: 1) window based feature extraction method; 2) deep Autoencoder based anomaly detection method; and 3) adversarial machine learning based explanation generation methodology. The presented approach was tested on two benchmark CAN datasets: OTIDS and Car Hacking. The anomaly detection performance of RX-ADS was compared against the state-of-the-art approaches on these datasets: HIDS and GIDS. The RX-ADS approach presented performance comparable to the HIDS approach (OTIDS dataset) and has outperformed HIDS and GIDS approaches (Car Hacking dataset). Further, the proposed approach was able to generate explanations for detected abnormal behaviors arising from various intrusions. Furthermore, these explanations were later validated by information used by domain experts to detect anomalies. Other advantages of RX-ADS include: 1) the method can be trained on unlabeled data; 2) explanations help experts in understanding anomalies and root course analysis, and also help with AI model debugging and diagnostics, ultimately improving user trust in AI systems.

42 ENGINEERING↗

Bridging Control and Deployment: A Cross-Layer Analysis of Scalable Building Cluster Control

Building cluster control has emerged as a promising approach for enabling flexible and coordinated operation of distributed building systems, yet its transition from pilot demonstrations to routine grid-interactive operation remains limited. This paper argues that this gap cannot be explained by control algorithms alone. Instead, it arises from interacting barriers in communication infrastructure, data and semantic interoperability, uncertainty management, stakeholder participation, market design, and policy support. Accordingly, the paper reviews both technical and non-technical barriers to building cluster control. Technical challenges include heterogeneous devices and protocols, communication latency and reliability, distributed decision-making, and uncertainty propagation across aggregated loads. Non-technical barriers include user participation, stakeholder coordination, incentive allocation, and data governance. Existing solution approaches are synthesized, including semantic interoperability frameworks, edge and hierarchical communication architectures, distributed and transactive control strategies, uncertainty-aware optimization, policy mechanisms, and market reforms. Based on this analysis, two research directions are identified: testing infrastructures that can evaluate control performance under realistic multi-building conditions, and abstraction methods that allow building clusters to interact with other energy sectors through standardized flexibility representations. Overall, the paper provides a structured review of how building cluster control can move from isolated demonstrations toward reproducible, market-compatible, and grid-relevant implementation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modernization of PLC-Based Control Systems at SNS

When the SNS site was built around 20 years ago, the Conventional Facilities (CF) control systems were de-signed using 2 communication protocols to allow pro-grammable logic controllers (PLCs) to interface with motors, variable frequency drives (VFDs), and remote input and output (I/O) devices. The protocol chosen to control motors and VFDs is DeviceNet, a CANbus-based protocol developed by Allen-Bradley, a subsidiary of Rockwell Automation. The protocol chosen to communi-cate with remote I/O is ControlNet, another protocol developed by Allen-Bradley. Both of these protocols are obsolete and present reliability and maintainability is-sues, particularly DeviceNet. As the Control Systems Section at SNS is working to modernize control systems throughout the machine, a major goal for PLC-based systems is to remove the obsolete communication proto-cols in favor of standard, ubiquitous Ethernet. To this end, any new VFDs installed use Ethernet communica-tion. Many VFDs are currently being replaced in the Central Utilities Building (CUB) and the Central Exhaust Facility (CEF) and are being removed from DeviceNet in favor of Ethernet communication. Planning is underway to retrofit Eaton Intelligent Technology motor control centers (MCCs) in the Target Building to remove particu-larly troublesome DeviceNet adaptors and replace them with Ethernet adaptors for each motor starter. The Con-trolNet network in the CUB has been demolished, with I/O drops integrated into a local Ethernet network, im-proving sustainability and maintainability.

Beaushaw, Isaiah [ORNL]↗

Cybersecurity of Networked Microgrids: Challenges Potential Solutions and Future Directions

Networked microgrids are clusters of geographically-close, islanded microgrids that can function as a single, aggregate island. This flexibility enables customer-level resilience and reliability improvements during extreme event outages and also reduces utility costs during normal grid operations. To achieve this cohesive operation, microgrid controllers and external connections (including advanced communication protocols, protocol translators, and/or internet connection) are needed. However, these advancements also increase the vulnerability landscape of networked microgrids, and significant consequences could arise during networked operation, increasing cascading impact. To address these issues, this report seeks to understand the unique components, functions, and communications within networked microgrids and what cybersecurity solutions can be implemented and what solutions need to be developed. A literature review of microgrid cybersecurity research is provided and a gap analysis of what is additionally needed for securing networked microgrids is performed. Relevant cyber hygiene and best practices to implement are provided, as well as ideas on how cybersecurity can be integrated into networked microgrid design. Lastly, future directions of networked microgrid cybersecurity R&D are provided to inform next steps.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microreactor Automated Control System Test Bed Digital Architecture for Real-Time, Hardware-in-the-Loop Simulation

This work describes progress made towards the development of a real-time hardware-in-the-loop (HIL) test bed for non-nuclear testing of microreactor control schemes and failure modes. Non-nuclear testing is a crucial step in developing robust control algorithms for managing microreactor dynamics. The creation of an HIL simulation harnesses the realistic dynamics of physical analogue systems while additionally considering the challenges of variable communication delay. This collaborative effort between Oak Ridge National Laboratory and Idaho National Laboratory has resulted in a LabVIEW-based gRPC communication protocol which couples a TRANSFORM Modelica simulation of nuclear components to the ViBRANT physical hardware for realistic feedback and visual representation of control action in real time. A modular python client structure is developed to manage FMU-based Modelica simulation and real-time gRPC communication. HIL testing suggests that the modeled reactor with natural convection molten salt loop coolant configuration responds well to PID control of drum positioning for modulation of reactor core power, however, future efforts will be made to explore the added thermal inertial delay of system level control and downstream demand changes. Development of this platform with a generalized methodology provides a foundation for exploring a variety of reactor configurations and failure modes in rapid order to provide insight into the most effective avenues of study for further research and development.

McConnell, Jono [ORNL] (ORCID:0000000238984741)↗

Security Enhancements for Distributed Energy Resource Systems Interconnected with Distribution Networks: Final Technical Report

The revised IEEE 1547 Standard defines new complex communication-adjustable voltage and frequency regulation and ride-through characteristics, while maintaining the general antiislanding requirement for unintentional islanding situations. Unintentional islanding is prohibited while intentional islanding is specifically allowed, thus effectively enabling microgrid operation mode. Further, IEEE 1547-2018 Standard introduces new requirements in terms of interoperability so that the DER plant/circuit segments may be seamlessly integrated with the utility networks but at the same time become vulnerable to a cyber-attack. Traditional cybersecurity measures including encryption, authentication and role-based access control may not be fully implementable to all communication protocols specified in the IEEE 1547 Standard. Therefore, in this project we have identified, researched, implemented and tested several cyberphysical approaches that rely mostly on the behavior of the DER circuit and may help with validating the incoming command and control action potentially coming through an insecure communications channel. Additionally, we have built semantic models and communications profiles for DER facilities and have implemented lightweight IEC 61850 based publisher-subscriber GOOSE messaging mechanism, with security extensions in terms of authentication and encryption. The project proposed information models for integration into UCA OpenFMB 2.0 profiles focusing on grid code compliance.

24 POWER TRANSMISSION AND DISTRIBUTION↗