Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cold climate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Healthy Indoor Air Quality: A Guide to Understanding Pollutants in Extreme Cold Climates

Internal air quality management through commonly supported recommendations in extreme cold weather climates is complicated by cold air infiltration. Air filtration and IAQ monitoring, through central and stand-alone systems can improve internal air quality to the benefit of occupant health and safety. This fact sheet includes reference information for pollutants, sources, health effects, and mitigation strategies.

cold climate↗

Monitoring of Unvented Roofs with Fibrous Insulation, Diffusion Vents, and Interior Vapor Control in a Cold Climate

This research involved construction of a conditioned test hut in a cold climate (Climate Zone 5A) with multiple side-by-side instrumented roof rafter bays. This work examined seven experimental unvented roofs and one code-compliant control hybrid ccSPF-cellulose roof over three winters and following summers. Examined variables included insulation material (fiberglass and cellulose), the presence or absence of a ridge diffusion vent (vapor-open material at the roof ridge to promote drying), the effect of various interior vapor control membranes (fixed and variable permeance), the effect of interior relative humidity, and the effect of interstitial airflow (from the interior into the cavity). This experiment was run over three winters, changing variables of interior conditions, roof configurations/materials, and the addition of intentional air leakage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Air Source Heat Pumps in Cold Climates

This booklet is geared toward homeowners who want to learn about air source heat pumps and covers how the technology works, how it performs in various cold-climate environments, and NREL project highlights.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mars and earth - Comparison of cold-climate features

On earth, glacial and periglacial features are common in areas of cold climate. On Mars, the temperature of the present-day surface is appropriate for permafrost, and the presence of water is suspected from data relating to the outgassing of the planet, from remote-sensing measurements over the polar caps and elsewhere on the Martian surface, and from recognition of fluvial morphological features such as channels. These observations and the possibility that ice could be in equilibrium with the high latitudes north and south of + or - 40 deg latitude suggest that glacial and periglacial features should exist on the planet. Morphological studies based mainly on Viking pictures indicate many features that can be attributed to the action of ice. Among these features are extensive talus aprons; debris avalanches; flows that resemble glaciers or rock glaciers; ridges that look like moraines; various types of patterned ground, scalloped scarps, and chaotically collapsed terrain that could be attributed to thermokarst processes; and landforms that may reflect the interaction of volcanism and ice.

Lucchitta, B. K.↗

Performance Evaluation and Costs of a Combined Ground Source Heat Pump and Solar Photovoltaic Storage System in an Extreme Cold Climate

This report outlines the effectiveness and economics of a ground source heat pump system installed together with solar photovoltaic panels and a battery storage system in a local community building situated in a cold climate. The community building is a tribal building located in Ruby, Alaska. Power from solar photovoltaic panels is supplemented by electricity purchased from the local community microgrid. A ground source heat pump was commissioned three years after the building was occupied, and supplements the heat generated by a boiler for both heat and domestic hot water. Data collected over the 2021-2022 heating season shows that the heat pump is providing heat to the building about 19% of the time with an average coefficient of performance of 2.68, ranging from below 2.5 in winter to above 3.0 in summer. The solar photovoltaic panels provided 4,700 kWh of power used within the building and an additional 2,900 kWh exported to the microgrid. The solar-produced power used within the building nearly offsets the estimated annual electrical draw of the heat pump of 5,700 kWh. Due to the very high costs for shipping and installation to remote locations, projects such as this, while not economically feasible if self-funded, can save the community an estimated $76,051 over a period of 20-years. Fuel prices increasing by more than 25%, or subsidized electricity prices decreasing by more than 25%, make the ground source heat pump a more viable option economically. Unsubsidized electricity prices increasing by 25% or more make a solar photovoltaic system with battery storage nearly economically viable after a 20-year period for commercial or school buildings that are not eligible for Alaska's Power Cost Equalization program.

14 SOLAR ENERGY↗

ResStock Measure Documentation: Cold Climate Air-Source Heat Pump

This report is part of series describing a variety of different ResStock™ measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "Cold Climate Air-Source Heat Pump" measure upgrade methodology and briefly discusses key results. All results can be accessed on the ResStock Open Energy Data Initiative "End-Use Load Profiles for the U.S. Building Stock" data lake and on the data viewer at resstock.nlr.gov.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dynamic Modelling and Performance Evaluation of a Chemisorption Heat Pump for Cold Climate

Space heating is a significant contributor to the energy consumption in residential buildings, especially in cold climates where electric-driven heat pumps lose the advantage of high efficiency and conventional gas-combustion furnaces have limited efficiency. Chemical adsorption (chemisorption) heat pumps (CSHP) have the potential for producing heating with high energy efficiency under cold operating conditions. A CSHP operates intermittently between desorption and adsorption modes, and their performance is affected by system design and transient system control. This study developed a dynamic model and used it to evaluate the daily system performance under different designs and controls, particularly the buffer tank size and the controlled minimum heating power. The simulation results revealed the effects of these parameters on the system performance and helped identify the optimal design and control for the highest coefficient of performance and heating capacity.

Yang, Zhiyao↗

Technoeconomic Design of a Geothermal-Enabled Cold Climate Zero Energy Community

Development of a zero energy community is more costly in northern cold climates than in moderate regions. Building energy loads are higher, thanks to the colder weather, and site solar photovoltaics (PV) are less productive due to lower solar incidence and misalignment with the buildings’ energy needs (summer production, winter demands). Geothermal energy production can support a zero energy community through application of energy efficiency (demand design), geothermal production (supply design), and asset dispatch as an integrated techno-economic package. This article presents the process used to explore geothermal system integration, our findings, and technical challenges for community-scale adoption of geothermal as an electric and thermal resource. We show that under a wide range of conditions, community-scale geothermal electric power and direct-use thermal energy is economically competitive with “business-as-usual” design and construction practices for zero energy communities. Furthermore, geothermal-produced energy will be self-consumed to a much greater extent than PV, resulting in significant reductions in site energy import and export. We conclude that under appropriate conditions, community-scale geothermal can be the most economically favorable energy resource for northern-climate zero energy community developments. Ongoing geothermal research and development to improve performance and reduce costs will further enhance the value proposition for community-scale geothermal technologies. We expect that including geothermal power and thermal energy in zero energy community design can improve its cost-effectiveness and therefore enhance the benefits of zero energy in more northern climates.

15 GEOTHERMAL ENERGY↗

Theoretical analysis of a refrigerant injection-enhanced air source heat pump with thermal energy storage for extended cold-climate and defrosting operations

This study investigates a conceptual refrigerant injection-enhanced air source heat pump with integrated thermal energy storage (ITES-ASHP) that combines two-phase flash tank injection with phase change material (PCM) thermal energy storage (TES) to extend cold-climate operation and maintain indoor heating during defrost. A steady-state, mode-based thermodynamic cycle model is developed to evaluate heating and defrosting modes with and without refrigerant injection and TES integration over an outdoor temperature range of 8 to −25 °C. The framework is applied to refrigerants R-290, R-454B, R-410 A, and R-32. A parametric study is conducted for an 18-kW system rated for an outdoor temperature of 8 °C, with the compressor frequency scheduled to 150 Hz. The optimal PCM phase-change temperature is identified as 20 °C for R-290, R-454B, and R-410 A, and 15 °C for R-32. At the design condition of −25 °C outdoor temperature, the proposed concept achieves a combined COP of 2.22 for R-290, corresponding to a 60% increase relative to the theoretical single-stage baseline for combined heating and defrosting operation. Safety screening based on compressor discharge temperature (≤ 120 °C) and injection quality (≥ 0.65), together with performance evaluation, indicates that R-290 is the most suitable candidate, followed by R-410 A and R-454B. Under the assumptions and constraints used here, R-32 is found to be less suitable due to excessive discharge temperatures and a higher risk of wet compression.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cold Climate Integrated Heat Pump

This paper introduces development of a residential air-source integrated heat pump for cold climates (CCIHP). The heat pump is multi-functional to meet all the home comfort demands, including space cooling, space heating, domestic water heating and energy storage. The CCIHP is an ideal solution to decarbonize northern homes via providing efficient space heating and water heating to replace natural gas. It uses a three-stage compressor and a single set of heat exchangers and valves to deliver all the functions, and thus achieve cost reduction. We developed an innovative system configuration and related controls to solve typical charge unbalance in heat pumps, accelerate charge migration and smoothen mode transition in integrated heat pumps. Laboratory investigations were conducted for individual modes and verified the control functions. Laboratory tests demonstrated that the unit delivered outstanding performance. It achieved 17.0 SEER (seasonal cooling energy efficiency rating) and 11.0 HSPF (heating seasonal performance factor). In the most efficient mode (combined space cooling and water heating mode), the unit reached a total energy efficiency of 35.0 EER and required only 25 minutes to heat a 50-gallon tank of water. The CCIHP can heat 1.7 GPM water from 58 to 125°F in a direct flow-through, when the ambient temperature is above 47°F. In a dedicated water heating mode using outdoor air source, the heat pump operated down to 17°F, achieving a COP > 2.6, and heated 50-gallon water within 1 hour.

Shen, Bo↗

Monitoring of Unvented Roofs with Fibrous Insulation, Diffusion Vents, and Interior Vapor Control in a Cold Climate

Unvented roof assemblies have been accepted in North American building codes since 2007; code-compliant construction calls for a minimum thickness of “air-impermeable insulation” (based on climate zone) to avoid cold-weather condensation and moisture risks. This is typically implemented with polyurethane spray foam insulation; however, negatives of this material include high first cost and possible adverse environmental impacts. Implementing unvented roofs in a moisture-safe manner with air-permeable fibrous fill insulations (e.g., fiberglass or cellulose) could potentially reduce the first cost of unvented roof designs, allowing for more widespread use. Building unvented roofs in a cost-effective, airtight, and moisture-safe manner opens up options for high-performance house designers and builders.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Clean Indoor Air and Lower Environmental Impacts: Heat Recovery Ventilation in Cold Climates

Over half of Alaska homes are at risk of poor indoor air quality, which increases the risk of respiratory and other illnesses for people and animals. Heat recovery ventilators (HRVs) provide warm, fresh air to a building interior while minimizing energy use. They can be programmed to provide varying amounts of fresh air to ensure adequate ventilation for occupants and can be configured to filter air during wildfires or other events. In addition to improving the safety of indoor air and extending the life of a building, HRVs can improve surrounding outdoor air because they reduce the amount of fossil fuels needed to heat a building. Recent research by CCHRC has focused on lowering barriers to using HRVs in cold climates through laboratory evaluations and homeowner education. This poster will cover data on indoor air quality in Alaska, results of CCHRC research, and future research questions.

buildings↗

High Efficiency Heat Pumps Can Pave the Path for Building Decarbonization in Cold Climates: Preprint

Heat pumps play an instrumental role in buildings decarbonization strategies. Recent advances in heat pump systems employ variable-speed compressor technology and electronically commutated fan motors. Inherently, the heating capacity and efficiency of heat pumps decrease with falling outdoor temperatures. Compared to single-speed heat pumps, variable speed systems can maintain higher heating and cooling efficiencies over a wider range of outdoor temperatures. The goal of this multi-phase project was to determine the energy savings of a high efficiency, variable-speed, air-source, split system heat pump designed for cold climate applications. The first project phase was to evaluate the performance of the heat pump in the laboratory under varying outdoor conditions in heating and cooling modes. The second phase was to translate the laboratory-measured performance into lookup tables for EnergyPlus hourly building simulation engine. Then, two sets of annual building simulations were performed using typical meteorological year weather from the Chicago-O'Hare airport for three different building types (a single-family residence, a strip mall, and a low-rise office building). The first set simulated a standard efficiency heat pump while the second set utilized the phase two performance tables to model a high efficiency heat pump. The high efficiency heat pump produced significant annual heating energy savings in all three buildings. The variable speed compressor and fan control also contributed to cooling energy savings. The simulated annual energy savings ranged from 22% to 35% over their respective baseline. The project's findings helped a Midwest electric utility, Commonwealth Edison (ComEd), design new incentives around high efficiency heat pumps.

cold climate heat pump↗

DOE Cold Climate Heat Pump Challenge Field Validation: Data Collection and Analysis Plan

This document details the data collection, storage, and analysis plan and methodologies for conducting the field validation portion of DOE’s Cold Climate Heat Pump (CCHP) Challenge. The study is focused on validating the in-field heating performance of prototypical CCHPs that have successfully demonstrated that they meet or exceed the Challenge specification in a laboratory setting. The units that have passed laboratory testing will be installed in real homes along with sensors and loggers for monitoring performance over an entire heating season. Data collected through monitoring will be cleaned and stored in a secure database. The data will be analyzed for calculating the key metrics defined by the Challenge including heating capacities at low outdoor air temperatures (below 32 °F), efficiency in terms of the Coefficient of Performance (COP), switchover temperatures and auxiliary heat staging. Demand Response (DR) capabilities will also be tested using specially designed DR events. In most cases, shoulder season and cooling season performance will also be determined and reported.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hygrothermal simulation of exterior retrofits in a cold climate

This work presents results from moisture modeling as part of a project undertaken by Pacific Northwest National Laboratory and its research partners, the University of Minnesota, and the Oak Ridge National Laboratory. The research goal is to identify exterior wall retrofit systems for cold climates that are low cost, energy efficient, and do not result in moisture durability problems. A base case wall was identified representing a typical wood frame construction, circa 1950. Retrofit options were selected based on input from industry, academia, and published work and seven options were constructed and installed at the University of Minnesota’s cold weather exposure facility in Cloquet, MN. Measurements were carried out during winter months and the data was used for model validation. Hygrothermal simulations were then carried out using WUFI (Version 6.4) in accordance with standard ANSI/ASRHAE 160-2016, Criteria for Moisture-Control Design Analysis in Buildings. Simulations were run out to three years and results show that the exterior retrofits improve thermal performance and do not negatively impact moisture durability of the existing wall.

Aldykiewicz Jr, Antonio↗

Residential Cold Climate Heat Pump Technology Challenge (Rheem) (CRADA NFE-22-09374 Final Report)

The purpose of this CRADA was to test a nominal 3-ton capacity heat pump system supplied by Rheem Manufacturing to determine if it met the laboratory test requirements of the United States Department of Energy Cold Climate Heat Pump (CCHP) Technology Challenge (hereafter noted as “the Challenge”). Results of the laboratory testing completed at ORNL demonstrated that the system met all requirements of the Challenge. Rheem Manufacturing has successfully completed this aspect of the Challenge. This CRADA report will briefly describe the CCHP Challenge, the test plan created to measure the success of heat pump systems provided by CCHP Challenge participants, and the results of laboratory testing of the Rheem heat pump system.

42 ENGINEERING↗

Performance Assessment of High Efficiency Variable Speed Air-Source Heat Pump in Cold Climate Applications

This project was part of an effort by ComEd's emerging technology program to evaluate the energy saving potential of new energy efficiency technologies. The focus of this technology assessment was to determine energy and peak demand savings potentials of a high efficiency variable speed, air-source, split system heat pump designed for cold climate applications. The results of this technology assessment will be used by CLEAResult to develop a new energy efficiency measure for Commonwealth Edison Company's incentive programs. The project utilized the National Renewable Energy Laboratory's (NREL) Thermal Test Facility to experimentally characterize cooling and heating performance of a high efficiency heat pump split system under varying outdoor climate conditions. The selected climate conditions represented summer and low temperature winter conditions in ComEd's service territory. The laboratory experimentation results were used to develop equipment performance curves required by EnergyPlus hourly simulation engine. Using typical meteorological year 3 weather data for the Chicago O'Hare airport, hourly building simulations (using the EnergyPlus engine) was utilized to estimate the annual energy savings of the high efficiency heat pump in comparison to a standard efficiency unit in the following U.S. Department of Energy (DOE) building codes program energy prototypes: Single-family residence; Strip mall; and Low-rise office.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Comparative Analysis of Lithium-Ion Battery Chemistries for Cold-Climate Maritime Applications

Energy storage, primarily in the form of electrochemical batteries, is critical for enabling integration of marine energy (e.g., power from waves and currents) with end-use applications at sea due to the periodicity of the resources and requirement of consistent, smooth power delivery. Powering high-latitude coastal or ocean-based observing systems has been identified as a high value-proposition use case, exemplifying the concept of Powering the Blue Economy. An existing power system implementation for such a platform uses solar panels coupled to rechargeable lithium-ion batteries, augmented by a non-rechargeable backup bank used to power heaters in winter months. As wave energy is a potential resource for powering this and similar use cases and is strongest when solar power is most limited, it was hypothesized that integration of wave power would alleviate some of the challenges in cold climates related to energy storage. In this work, we investigate the use case scenario in simulation and perform a comparative test of commercially-available lithium-ion battery chemistry formulations to determine the most appropriate choice for the application. The experiment compared the most commonly-used lithium-based battery types (NCM, NCA, and LFP) in laboratory conditions emulating a battery enclosure thermally coupled to freezing seawater using an industrial battery performance tester in PNNL's arctic simulation lab. Battery strings were repeatedly cycled (i.e., charged, discharged, rested) and their usable capacity was measured. Both NCM and NCA strings exhibited degradation upon cycling, while the LFP string maintained stable operation through over 700 complete cycles. Though lower in baseline capacity, LFP are recommended for this and similar low-temperature applications with access to high levels of bulk charging current (e.g., from high-energy wave events) and their use may reduce the cost and complexity of battery conditioning and protection apparatus.

16 TIDAL AND WAVE POWER↗