Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coaxial”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Temperature, rf field, and frequency dependence performance evaluation of superconducting niobium half-wave coaxial cavity

Recent advancement in superconducting radio frequency cavity processing techniques, with diffusion of impurities within the RF penetration depth, resulted in high quality factor with increase in quality factor with increasing accelerating gradient. The increase in quality factor is the result of a decrease in the surface resistance as a result of nonmagnetic impurities doping and change in electronic density of states. The fundamental understanding of the dependence of surface resistance on frequency and surface preparation is still an active area of research. Here, we present the result of RF measurements of the TEM modes in a coaxial half-wave niobium cavity resonating at frequencies between 0.3 ? 1.3 GHz. The temperature dependence of the surface resistance was measured between 4.2 K and 1.6 K. The field dependence of the surface resistance was measured at 2.0 K. The baseline measurements were made after standard surface preparation by buffered chemical polishing.

Dhakal, P.↗

Multipactor in Coaxial Line Induced by DC Bias

High DC voltage applied between outer and inner electrodes of coaxial transmission lines is considered and actually is an effective remedy against multipactor in these lines. However, the high voltage bias being below certain level itself initiates multipacting. In this technical note the experimental manifestation and numerical simulations of the phenomenon are presented.

43 PARTICLE ACCELERATORS↗

Characterization of power delivery and losses in a long coaxial inner MITL

The long coaxial inner magnetically insulated transmission line (MITL) is considered as a possible transmission line to guide power to deep underground high yield fusion experiments. The considered dimensions are of order 10-15 meters in length, 60 cm radius, and 6 mm AK gap, with peak current 60 MA and peak pulse 100 ns. In designing such a MITL, the main concern is power loss due to low density plasmas being produced by high electric fields and temperatures. It is found that a 10m-long prototypical MITL is a viable design, with maximum current losses below 10% and temperature rise due to electron impact not exceeding 400°C, thereby avoiding thermal desorption of contaminants and the formation of low density plasmas.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Lightning Induced Interior Fields And Voltage Bounds For Coaxial Topologies

We assemble bounding formulas for the interior fields and pin voltages inside a cylindrical coaxial Faraday cage which has been struck by lightning. Approximate formulas for penetrations through a circumferential door slot with subsequent coupling to the interior center conductor structure. Fields at the opposite open end are estimated and used to drive a capped connector and estimate interior pin voltages. Finally, penetrations through small circular holes and direct diffusion through the barrier are also addressed.

42 ENGINEERING↗

First Axionlike Particle Results from a Broadband Search for Wavelike Dark Matter in the 44 to 52 μ eV Range with a Coaxial Dish Antenna

We present the results from the first axionlike particle search conducted using a dish antenna. The experiment was conducted at room temperature and sensitive to axionlike particles in the 44 – 52 μ eV range (10.7–12.5 GHz). The novel dish antenna geometry was proposed by the BREAD Collaboration and previously used to conduct a dark photon search in the same mass range. To allow for axionlike particle sensitivity, the BREAD dish antenna was placed in a 3.9 T solenoid magnet at Argonne National Laboratory. In the presence of a magnetic field, axionlike dark matter converts to photons at the conductive surface of the reflector. The signal is focused onto a custom coaxial horn antenna and read out with a low-noise radio-frequency receiver. No evidence of axionlike dark matter was observed in this mass range and we place the most stringent laboratory constraints on the axion-photon coupling strength, g a γ γ , in this mass range at 90% confidence.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design Enhancements for the SNS RFQ Coaxial Coupler

The H⁻ ion linear accelerator at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory operates with reliability that routinely surpasses 90% during scheduled beam operation. With the ambitious goal of eventually achieving at least 95% availability, several upgrade and improvement projects are ongoing. One such project is the modification of the coaxial couplers that transfer radio frequency (RF) power to the accelerator’s Radio Frequency Quadrupole (RFQ). The proposed modification utilizes stub sections and capacitive coupling to construct a physically separable assembly with DC isolation. With a separated coupler assembly, the section that includes the magnetic coupling loop can be permanently mounted to the RFQ which would eliminate the need to re-adjust the couplers after maintenance activities, upgrades, and repairs. Additionally, the modified design would provide increased multipaction suppression with DC biasing and potentially lower thermal gradients across the device. This paper presents the design and simulation results of the project.

Toby, George↗

Distributed Coaxial Cable Sensors for In-Situ Condition Based Monitoring of Coal-Fired Boiler Tubes

The increasing contributions of renewable energy sources present new challenges to the operation and maintenance of the existing coal-fired power plants. One of the major operational risks is the unexpected failure of superheater boiler tubes, leading to the most unplanned power plant outrages. The boiler tube failure is difficult to predict due to the harsh operating environments. Therefore, condition-based monitoring (CBM) with a reliable high temperature sensor becomes necessary to produce a meaningful assessment of the health condition of boiler tubes and their remaining lifetime. In this work, the stainless-steel and quartz coaxial cable sensor (SSQ-CCS) is proposed for in-situ distributed monitoring of the boiler tube temperatures in existing coal-fired power plants. Comprehensive tests have been conducted with an in-house testing facility at Clemson University to study and evaluate the sensors’ performance in the temperature range of 100℃ to 600℃. The results indicated that the measurement resolution of the SSQ-CCS sensor is better than 1℃, and the drift is less than 2% over long-period testing. Meanwhile, multi-physics finite element analysis has been conducted to optimize the design and evaluate the safety of the SSQ-CCS temperature sensor under various operational conditions. Based on the performance obtained in the laboratory-scale testing, a field test has been implemented at a power plant. Four SSQ-CCS temperature sensors were installed for in-situ monitoring of the temperatures of a power plant’s superheat tube assembles. The data acquisition system has been successfully set up and collected sensing signals for more than three months. The sensing signals have been post-processed, and the monitored temperature history through the SSQ-CCS temperature sensor has been validated and compared with the conventional high temperature thermal couple data.

Jiao, Xinyu↗

Two-Frequency RF Fields Induced Multipactor in Coaxial Transmission Line

This work investigates multipactor discharge in coaxial geometry with two-frequency rf electric field Vrf [sin(𝜔𝑡+𝜃)+𝛽 sin(n(𝜔𝑡+𝜃)+𝛾)], where Vrf is the peak voltage, 𝛽 is the field strength of the second car-rier mode relative to fundamental mode, n is the ratio of two carrier fre-quencies and 𝛾 is the relative phase of second carrier mode.

43 PARTICLE ACCELERATORS↗

Melt pool instability detection using coaxial photodiode system validated by in-situ X-ray imaging

A co-axial photodiode monitoring system with high temporal resolution has been integrated into a proven test bench enabling synchronized side-view high speed X-ray imaging of melt pool dynamics and top-view spectral emission characterization of the melt pool. Here, this setup enables direct observation of melt pool phenomena and correlation between the two monitoring systems which can be directly scaled to commercial systems. The work demonstrates a 92% detection rate in keyhole collapse phenomena related to defect generation in SLM. Furthermore, the impact of gas flow on monitoring signals is studied to understand the fundamental importance of gas flow in commercial systems.

36 MATERIALS SCIENCE↗