Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “clamp”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Temperature-Controlled Clamping and Releasing Mechanism

A report describes the development of a mechanism that automatically clamps upon warming and releases upon cooling between temperature limits of approx. =180 K and approx. =293 K. The mechanism satisfied a need specific to a program that involved repeated excursions of a spectrometer between a room-temperature atmospheric environment and a cryogenic vacuum testing environment. The mechanism was also to be utilized in the intended application of the spectrometer, in which the spectrometer would be clamped for protection during launch of a spacecraft and released in the cold of outer space to allow it to assume its nominal configuration for scientific observations. The mechanism is passive in the sense that its operation does not depend on a control system and does not require any power other than that incidental to heating and cooling. The clamping and releasing action is effected by bolt-preloaded stacks of shape-memory-alloy (SMA) cylinders. In designing this mechanism, as in designing other, similar SMA mechanisms, it was necessary to account for the complex interplay among thermal expansion, elastic and inelastic deformation under load, and SMA thermomechanical properties.

Rosing, David↗

Modeling and Mitigation of Multi-Loops Related Device Overvoltage in Three Level Active Neutral Point Clamped Converter

This paper establishes an analytical model for the device drain-source overvoltage related to the two loops in three level active neutral point clamped (3L-ANPC) converters. Taking into account the non-linear device output capacitance, two commonly used modulations are investigated in detail. The result shows that the line switching frequency device usually has higher overvoltage, and the switching speed of the high switching frequency device is not strongly influenced by the multiple loops. By keeping the non-active clamping switch off, the effect of the non-linear device output capacitance can be significantly mitigated, which helps reduce the overvoltage. Moreover, the loop inductance can be reduced with vertical loop layout and magnetic cancellation in PCB and busbar design. A 500 kVA 3L-ANPC converter using SiC MOSFETs is built and tested. The experimental results validate the overvoltage model of the two modulations as well as the busbar design. With the non-active clamping switch off, the overvoltage of both the high and line switching frequency devices is significantly reduced, which helps achieve higher switching speed.

Model↗

Laser microsurgery of higher plant cell walls permits patch-clamp access

Plasma membranes of guard cells in epidermal peels of Vicia faba and Commelina communis can be made accessible to a patch-clamp pipet by removing a small portion (1-3 micrometers in diameter) of the guard cell wall using a microbeam of ultraviolet light generated by a nitrogen laser. Using this laser microsurgical technique, we have measured channel activity across plasma membranes of V. faba guard cells in both cell-attached and isolated patch configurations. Measurements made in the inside-out patch configuration revealed two distinct K(+)-selective channels. Major advantages of the laser microsurgical technique include the avoidance of enzymatic protoplast isolation, the ability to study cell types that have been difficult to isolate as protoplasts or for which enzymatic isolation protocols result in protoplasts not amenable to patch-clamp studies, the maintenance of positional information in single-channel measurements, reduced disruption of cell-wall-mediated signaling pathways, and the ability to investigate intercellular signaling through studies of cells remaining situated within tissue.

Non-NASA Center↗

Laser-assisted patch clamping: a methodology

Laser microsurgery can be used to perform both cell biological manipulations, such as targeted cell ablation, and molecular genetic manipulations, such as genetic transformation and chromosome dissection. In this report, we describe a laser microsurgical method that can be used either to ablate single cells or to ablate a small area (1-3 microns diameter) of the extracellular matrix. In plants and microorganisms, the extracellular matrix consists of the cell wall. While conventional patch clamping of these cells, as well as of many animal cells, requires enzymatic digestion of the extracellular matrix, we illustrate that laser microsurgery of a portion of the wall enables patch clamp access to the plasma membrane of higher plant cells remaining situated in their tissue environment. What follows is a detailed description of the construction and use of an economical laser microsurgery system, including procedures for single cell and targeted cell wall ablation. This methodology will be of interest to scientists wishing to perform cellular or subcellular ablation with a high degree of accuracy, or wishing to study how the extracellular matrix affects ion channel function.

Non-NASA Center↗

Calibrated clamp facilitates pressure application

Spring-loaded clamp applies specific pressure to hold materials together during bonding, welding, and machining. The clamp has two adjustable legs terminating in suction cups for easy attachment to a surface.

Source record↗

Tool facilitates installation of Marmon clamps

Adjustable tool facilitates the installation of Marmon clamps. It provides sufficient mechanical advantage to force the clamps into place, permitting one man operation. Two handles provide the major leverage, and a pivoting arm with a slot enables snap-out action.

Peters, G. A.↗

Experimental transient and permanent deformation studies of steel-sphere-impacted or impulsively-loaded aluminum beams with clamped ends

The sheet explosive loading technique (SELT) was employed to obtain elastic-plastic, large-deflection transient and/or permanent strain data on simple well-defined structural specimens and materials: initially-flat 6061-T651 aluminum beams with both ends ideally clamped via integral construction. The SELT loading technique was chosen since it is both convenient and provides forcing function information of small uncertainty. These data will be useful for evaluating pertinent structural response prediction methods. A second objective was to obtain high-quality transient-strain data for a well-defined structural/material model subjected to impact by a rigid body of known mass, impact velocity, and geometry; large-deflection, elastic-plastic transient response conditions are of primary interest. The beam with both ends clamped and a steel sphere as the impacting body were chosen. The steel sphere was launched vertically by explosive propulsion to achieve various desired impact velocities. The sphere/beam impact tests resulted in producing a wide range of structural responses and permanent deformations, including rupture of the beam from excessive structural response in two cases. The transient and permanent strain data as well as the permanent deflection data obtained are of high quality and should be useful for checking and evaluating methods for predicting the responses of simple 2-d structures to fragment (sphere) impact. Transient strain data very close to the point of impact were not obtained over as long a time as desirable because the gage(s) in that region became detached during the transient response.

Witmer, E. A.↗

Cable-clamp installation tool

Tiny vise simplifies installation of cable clamps in confined spaces. As thumbscrew is tightened, ears of clamps are forced together, and bolt passes through all lugs and into hole in stationary jaw.

Noel, M. B.↗

Clamp Restrains Pressure Line

Safety restraint protects people and property if a high-pressure fitting fails. As long as pressure line remains attached at the fitting, clamp exerts essentially no force on hose. If fitting fails, force of fluid leaving free end of hose causes the cam on the clamp to compress hose with a positive locking action.

Aliberti, J. A.↗

Plastic Clamp Retains Clevis Pin

Plastic clamp requires no special installation or removal tools. Clamp slips easily over end of pin. Once engaged in groove, holds pin securely. Installed and removed easily without special tools - screwdriver or putty knife adequate for prying out of groove. Used to retain bearings, rollers pulleys, other parts that rotate. Applications include slowly and intermittently rotating parts in appliances.

Cortes, R. G.↗

Reusable thermal cycling clamp

A reusable metal clamp for retaining a fused quartz ampoule during temperature cycling in the range of 20 deg C to 1000 deg C is described. A compressible graphite foil having a high radial coefficient of thermal expansion is interposed between the fused quartz ampoule and metal clamp to maintain a snug fit between these components at all temperature levels in the cycle.

Debnam, W. J., Jr.↗

Tensil Film Clamps And Mounting Block For Viscoelastometers

Set of clamps and mounting block developed for use in determining tensile moduli and damping properties of films in manually operated or automated commercial viscoelastometer. These clamps and block provide uniformity of sample gripping and alignment in instrument. Dependence on operator and variability of data greatly reduced.

Stoakley, Diane M.↗

Tensile film clamps and mounting block for the rheovibron and autovibron viscoelastometer

A set of film clamps and a mounting block for use in the determination of tensile modulus and damping properties of films in a manually operated or automated Rheovibron is diagrammed. These clamps and mounting block provide uniformity of sample gripping and alignment in the instrument. Operator dependence and data variability are greatly reduced.

Stoakley, Diane M.↗

Cantilever clamp fitting

A device is disclosed for sealing and clamping a cylindrical element which is to be attached to an object such as a wall, a pressurized vessel or another cylindrical element. The device includes a gland having an inner cylindrical wall, which is threaded at one end and is attached at a bendable end to a deformable portion, which in turn is attached to one end of a conical cantilever structure. The other end of the cantilever structure connects at a bendable area to one end of an outer cylindrical wall. The opposite end of cylindrical wall terminates in a thickened portion, the radially outer surface of which is adapted to accommodate a tool for rotating the gland. The terminal end of cylindrical wall also includes an abutment surface, which is adapted to engage a seal, which in turn engages a surface of a receiver. The receiver further includes a threaded portion for engagement with the threaded portion of gland whereby a tightening rotation of gland relative to receiver will cause relative movement between cylindrical walls and of gland. This movement causes a rotation of the conical structure and thus a bending action at bending area and at the bending end of the upper end of inner cylindrical wall. These rotational and bending actions result in a forcing of the deformable portion radially inwardly so as to contact and deform a pipe. This forcible contact creates a seal between gland and pipe, and simultaneously clamps the pipe in position.

Melton, Patrick B.↗

Quick action clamp

A quick release toggle clamp that utilizes a spring that requires a deliberate positive action for disengagement is presented. The clamp has a sliding bolt that provides a latching mechanism. The bolt is moved by a handle that tends to remain in an engaged position while under tension.

Calco, Frank S.↗

Cracking associated with micrometeoroid impact craters in anodized aluminum alloy clamps on LDEF

The Long Duration Exposure Facility (LDEF) is a reusable hollow-cylindrical satellite sustaining a total of 57 different experiments. The 130 sq m of spacecraft surface area included anodized 6061-T6 Al alloy bay frames and clamps for holding experiment trays in the bay areas. Attention is presently given to the micrometeoroid impact crater features observed on two tray clamps recovered from the LDEF leading-edge locations. It is found that even very subtle surface modifications in structural alloy anodizing can influence micrometeoroid impact crater cracking, notable radial cracking due to the ejecta-rim of the impact craters.

Murr, Lawrence E.↗