Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “clamp”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Cylindrical claw clamp has quick release feature

Claw clamp grasps cylindrical shapes by pressing its jaws around the object. The clamp is released by retraction of a release pin which extends beyond the clamp handle on both sides for better purchase.

Goodwin, G. D.↗

Quick-attach clamp

Clamp of the slideable jaw type can be applied to moving lines such as cables or ropes. The clamp has a trigger-operated jaw that can be attached to a redrop parachute on a moving tow cable. The trigger mechanism maintains the jaws retracted in the housing until they are released for clamping.

Vano, A. E.↗

An ideal clamping analysis for a cross-ply laminate

Different elementary clamping models are discussed for a three layer crossply laminate to study the sensitivity of clamping to the definition of cross-sectional rotation. All of these models leave a considerable residual warping at the edges. Using a complimentary energy principle and principle of superposition, an analysis is conducted to reduce this residual warping. This led to the identification of exact interior solution corresponding to the ideal clamping. This study also suggests a presence of stress singularities at the corners and between different layers near the fixed edge.

Valisetty, R. R.↗

Surface characterization of selected LDEF tray clamps

The surface characterization of chromic acid anodized 6061-T6 aluminum alloy tray clamps has shown differences in surface chemistry depending upon the position on the Long Duration Exposure Facility (LDEF). Water contact angle results showed no changes in wettability of the tray clamps. The overall surface topography of the control, trailing edge(E3) and leading edge(D9) samples was similar. The thickness of the aluminum oxide layer for all samples determined by Auger depth profiling was less than one micron. X-ray photoelectron spectroscopy (XPS) analysis of the tray clamps showed significant differences in the surface composition. Carbon and silicon containing compounds were the primary contaminants detected.

Cromer, T. F.↗

Large-deflection theory for end compression of long rectangular plates rigidly clamped along two edges

The von Karman equations for flat plates are solved beyond the buckling load up to edge strains equal to eight time the buckling strain, for the extreme case of rigid clamping along the edges parallel to the load. Deflections, bending stresses, and membrane stresses are given as a function of end compressive load. The theoretical values of effective width are compared with the values derived for simple support along the edges parallel to the load. The increases in effective width due to rigid clamping drops from about 20 percent near the buckling strain to about 8 percent at an edge strain equal to eight times the buckling strain. Experimental values of effective width in the elastic range reported in NACA Technical Note No. 684 are between the theoretical curves for the extremes of simple support and rigid clamping.

Levy, Samuel↗

Self-locking clamping tool with swivel jaws

A plier-like tool (11) having two plier-like members (13, 15) pivotally joined togther intermediate of their ends and having handle portions (17, 18) and swivel jaw members (29,30). An automatic locking mechanism (27) extending between the members permits an user to clamp the handle portions together so as to clamp the jaw members on an object (25) but holds the position so reached if the clamping action of the user is removed. A release device (65) is provided so that the jaw members may be opened up again. A compression spring (23) extending between the members (19, 20) assists in the opening of the jaw members. The swivel jaw members (29, 30) permit the user to rotate the plier-like members (13,15) relative to the object (25) being grasped.

Redmon, Jr., John W.↗

Evaluation of Grounding Impedance of a Complex Lightning Protective System Using Earth Ground Clamp Measurements and ATP Modeling

A new Lightning Protection System (LPS) was designed and built at Launch Complex 39B (LC39B), at the Kennedy Space Center (KSC), Florida, which consists of a catenary wire system (at a height of about 181 meters above ground level) supported by three insulators installed atop three towers in a triangular configuration. A total of nine downconductors (each about 250 meters long, on average) are connected to the catenary wire system. Each of the nine downconductors is connected to a 7.62-meter radius circular counterpoise conductor with six equally spaced 6-meter long vertical grounding rods. Grounding requirements at LC39B call for all underground and above ground metallic piping, enclosures, raceways, and cable trays, within 7.62 meters of the counterpoise, to be bounded to the counterpoise, which results in a complex interconnected grounding system, given the many metallic piping, raceways, and cable trays that run in multiple direction around LC39B. The complexity of this grounding system makes the fall of potential method, which uses multiple metallic rods or stakes, unsuitable for measuring the grounding impedances of the downconductors. To calculate the downconductors grounding impedance, an Earth Ground Clamp (a stakeless grounding resistance measuring device) and a LPS Alternative Transient Program (ATP) model are used. The Earth Ground Clamp is used to measure the loop impedance plus the grounding impedance of each downconductor and the ATP model is used to calculate the loop impedance of each downconductor circuit. The grounding impedance of the downconductors is then calculated by subtracting the ATP calculated loop impedances from the Earth Ground Clamp measurements.

Mata, Carlos T.↗

Temperature-Controlled Clamping and Releasing Mechanism

A report describes the development of a mechanism that automatically clamps upon warming and releases upon cooling between temperature limits of approx. =180 K and approx. =293 K. The mechanism satisfied a need specific to a program that involved repeated excursions of a spectrometer between a room-temperature atmospheric environment and a cryogenic vacuum testing environment. The mechanism was also to be utilized in the intended application of the spectrometer, in which the spectrometer would be clamped for protection during launch of a spacecraft and released in the cold of outer space to allow it to assume its nominal configuration for scientific observations. The mechanism is passive in the sense that its operation does not depend on a control system and does not require any power other than that incidental to heating and cooling. The clamping and releasing action is effected by bolt-preloaded stacks of shape-memory-alloy (SMA) cylinders. In designing this mechanism, as in designing other, similar SMA mechanisms, it was necessary to account for the complex interplay among thermal expansion, elastic and inelastic deformation under load, and SMA thermomechanical properties.

Rosing, David↗

Modeling and Mitigation of Multi-Loops Related Device Overvoltage in Three Level Active Neutral Point Clamped Converter

This paper establishes an analytical model for the device drain-source overvoltage related to the two loops in three level active neutral point clamped (3L-ANPC) converters. Taking into account the non-linear device output capacitance, two commonly used modulations are investigated in detail. The result shows that the line switching frequency device usually has higher overvoltage, and the switching speed of the high switching frequency device is not strongly influenced by the multiple loops. By keeping the non-active clamping switch off, the effect of the non-linear device output capacitance can be significantly mitigated, which helps reduce the overvoltage. Moreover, the loop inductance can be reduced with vertical loop layout and magnetic cancellation in PCB and busbar design. A 500 kVA 3L-ANPC converter using SiC MOSFETs is built and tested. The experimental results validate the overvoltage model of the two modulations as well as the busbar design. With the non-active clamping switch off, the overvoltage of both the high and line switching frequency devices is significantly reduced, which helps achieve higher switching speed.

Model↗

Origin of Ferroelectric Phase Stabilization via the Clamping Effect in Ferroelectric Hafnium Zirconium Oxide Thin Films

The presence of the top electrode on hafnium oxide-based thin films during processing has been shown to drive an increase in the amount of metastable ferroelectric orthorhombic phase and polarization performance. This “Clamping Effect,” also referred to as the Capping or Confinement Effect, is attributed to the mechanical stress and confinement from the top electrode layer. However, other contributions to orthorhombic phase stabilization have been experimentally reported, which may also be affected by the presence of a top electrode. In this study, it is shown that the presence of the top electrode during thermal processing results in larger tensile biaxial stress magnitudes and concomitant increases in ferroelectric phase fraction and polarization response, whereas film chemistry, microstructure, and crystallization temperature are not affected. Through etching experiments and measurement of stress evolution for each processing step, it is shown that the top electrode locally inhibits out-of-plane expansion in the HZO during crystallization, which prevents equilibrium monoclinic phase formation and stabilizes the orthorhombic phase. This study provides a mechanistic understanding of the clamping effect and orthorhombic phase formation in ferroelectric hafnium oxide-based thin films, which informs the future design of these materials to maximize ferroelectric phase purity and corresponding polarization behavior.

36 MATERIALS SCIENCE↗

Laser microsurgery of higher plant cell walls permits patch-clamp access

Plasma membranes of guard cells in epidermal peels of Vicia faba and Commelina communis can be made accessible to a patch-clamp pipet by removing a small portion (1-3 micrometers in diameter) of the guard cell wall using a microbeam of ultraviolet light generated by a nitrogen laser. Using this laser microsurgical technique, we have measured channel activity across plasma membranes of V. faba guard cells in both cell-attached and isolated patch configurations. Measurements made in the inside-out patch configuration revealed two distinct K(+)-selective channels. Major advantages of the laser microsurgical technique include the avoidance of enzymatic protoplast isolation, the ability to study cell types that have been difficult to isolate as protoplasts or for which enzymatic isolation protocols result in protoplasts not amenable to patch-clamp studies, the maintenance of positional information in single-channel measurements, reduced disruption of cell-wall-mediated signaling pathways, and the ability to investigate intercellular signaling through studies of cells remaining situated within tissue.

Non-NASA Center↗

Laser-assisted patch clamping: a methodology

Laser microsurgery can be used to perform both cell biological manipulations, such as targeted cell ablation, and molecular genetic manipulations, such as genetic transformation and chromosome dissection. In this report, we describe a laser microsurgical method that can be used either to ablate single cells or to ablate a small area (1-3 microns diameter) of the extracellular matrix. In plants and microorganisms, the extracellular matrix consists of the cell wall. While conventional patch clamping of these cells, as well as of many animal cells, requires enzymatic digestion of the extracellular matrix, we illustrate that laser microsurgery of a portion of the wall enables patch clamp access to the plasma membrane of higher plant cells remaining situated in their tissue environment. What follows is a detailed description of the construction and use of an economical laser microsurgery system, including procedures for single cell and targeted cell wall ablation. This methodology will be of interest to scientists wishing to perform cellular or subcellular ablation with a high degree of accuracy, or wishing to study how the extracellular matrix affects ion channel function.

Non-NASA Center↗

EEPD1 evolved a unique DNA clamping dimer protecting reversed replication forks

Exonuclease/endonuclease/phosphatase (EEP)-fold hydrolases are canonically monomeric phosphodiesterases exemplified by APE1, DNase I, and TDP2 nucleases. While EEP family domain containing protein 1 (EEPD1) acts in DNA stress responses, its proposed nuclease activities are enigmatic. Here, we integrate hybrid structural methods, evolution, biochemistry, cancer genomics, plus molecular and cell biology to define EEPD1 structure, assembly, and function at stalled DNA replication forks. Results imply EEPD1 surprisingly requires both unique EEP domain dimer and distinctive tandem Helix-hairpin-Helix [(HhH) 2 ] domains to clamp double-stranded (ds) DNA at reversed DNA replication forks for fork protection. Small-angle X-ray Scattering (SAXS), crystal, and cryo-EM structures unveil an unprecedented tryptophan handshake dimer, conserved interface di-Trp-Pro pocket, and adjustable “wrist” enabling an open-closed conformational switch. EEPD1 dimer cooperatively binds complex dsDNA replication fork intermediates but alone lacks nuclease activity due to loss of key EEP catalytic residues during Metazoan evolution and atmospheric oxygen buildup. Instead, EEPD1 prevents nucleolytic degradation of reversed replication forks by MRE11. Furthermore, cancer bioinformatics support oxidative damage-dependent EEPD1 association as a significant modulator of overall patient survival. Collective findings uncover unexpected EEP dimer and fork protection function in clamping, not cleaving, reversed replication forks for metazoan oxidative stress responses controlling genome stability and cancer outcomes.

Shen, Runze [Univ. of Texas, Houston, TX (United S↗

Rolling Meadows Golf Course - CLAMPS 1 Lidar / Reviewed Data

This dataset contains data from the CLAMPS 1 Halo Photonics StreamLine Doppler Lidar at the Rolling Meadows Golf Course site. CLAMPS 1 deployed during fall-winter 2022 (10/3/22-12/27/23) and summer-fall 2023 (6/16/23-10/1/23).

17 WIND ENERGY↗

ARM Site E36 - CLAMPS 2 AERI / Reviewed Data

This dataset contains radiance data from the CLAMPS 2 AERI at the Atmospheric Radiation Measurement (ARM) site E36. CLAMPS 2 deployed during fall-winter 2022 (10/3/22-12/27/23) and summer-fall 2023 (6/16/23-10/1/23).

17 WIND ENERGY↗

ARM Site E36 - CLAMPS 2 Microwave Radiometer / Processed Data

This dataset contains processed data from the CLAMPS 2 Humidity And Temperature PROfiler (HATPRO) Microwave Radiometer and its associated meteorology tower. CLAMPS 2 deployed during fall-winter 2022 (10/3/22-12/27/23) and summer-fall 2023 (6/16/23-10/1/23).

17 WIND ENERGY↗

Site Rolling Meadows Golf Course - CLAMPS 1 Lidar / Raw Data

This dataset contains raw data from the CLAMPS 1 Halo Photonics StreamLine Doppler Lidar at the Rolling Meadows Golf Course site. CLAMPS 1 deployed during fall-winter 2022 (10/3/22-12/27/23) and summer-fall 2023 (6/16/23-10/1/23).

17 WIND ENERGY↗