Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “city evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Urbanization effects on the spatial patterns of spring vegetation phenology depend on the climatic background

Cities have been considered ideal surrogates for evaluating ecological responses to climate warming. Although research has revealed that the urban heat island effect is not the only determinant that drives the rural-urban difference in spring phenology, limited attempts further explore the effect of complex interactions between urbanization and climates on the start of the season (SOS). Here, we employed the percentage of impervious surface area as an indicator of urbanization levels, incorporating the urban heat island (UHI) effect and climates to decipher the multiple effects on the temporal shift in SOS. Our results suggest that urbanization, the UHI effect, and climates jointly drive the phenological timing in cities. Further, the SOS is highly linearly correlated with urbanization levels and UHI effects (p<0.001) in the zones with warm and humid climates, whereas relatively warmer, cooler, or arid climates break down the linearity. Geographically, the SOS is north-south symmetrical for the rural-urban ecosystem at the national scale, which initiates at the mid-latitudes (around 30 °N, 67.58 DOY ± 2.23 days) first and then towards the low (around 20 °N, 105.25 DOY ± 1.31 days) and high-latitudes (45 °N, 123.01 DOY ± 1.45 days). Chilling accumulation and spring temperature jointly contribute to this phenomenon. As the UHI effect is similar to the projected global warming in the future, understanding the phenological responses to urbanization in various climates is insightful for evaluating the impact of future warming on plants' phenological behavior in the global ecosystem.

54 ENVIRONMENTAL SCIENCES↗

Navigating Urban Mobility: Evaluating Infrastructure Strategies for Enhanced Energy-Efficient Access for Micromobility

Cities and communities continue to expand pedestrian and bicycle infrastructure as part of their sustainable mobility and post-pandemic recovery plans. However, the emergence of micro-mobility (e.g., electric bicycles) has created new challenges for urban transport planning. As the popularity of micro-mobility modes has grown, so have safety concerns due to rising injuries, thus challenging many cities to come up with regulatory measures that enable efficient access while minimizing negative impacts from micro-mobility. Leveraging the Open-Source Tool (Mobility Energy Productivity metric), powered by an open-source dataset (OpenStreetMap), and enhanced through the incorporation of perceived discomfort (level-of-traffic stress), this research study focuses on evaluating the accessibility implications of infrastructure planning and regulatory measures for micro-mobility. Five scenarios pertaining to level of traffic stress, sidewalk access, traffic calming, and bike lane coverage were tested in the Denver-Aurora region in Colorado. Maximum improvements in energy-efficient access are realized when allowing sidewalks for micro-mobility use. Cities and planning agencies could leverage this information to assess sidewalk use policies for micro-mobility, while ensuring pedestrian safety and ADA access. Results indicate that expansion of bicycle lane coverage yields 11% accessibility benefits for micro-mobility compared to implementing traffic calming measures yielding 3% accessibility improvements. Further, it was observed most of the population in the Denver-Aurora region is experiencing lower accessibility in-part due to presence of a high-stress connections in the network. Although not generalizable, the use of open-source data and access calculation methodology, make this analysis reproducible and transferable to other locations.

ADVANCED PROPULSION SYSTEMS↗

Where to cool off: a geospatial framework for placement of cooling centers

Indoor cooling is essential to reduce heat stress and increase passive survivability during heatwaves. Although air conditioning (AC) is recommended for maintaining indoor thermal comfort, low- and medium-income households in the U.S. often do not own an AC and/or limit AC usage to reduce energy consumption and associated costs, thereby risking their health and safety. With the frequency and intensity of heatwaves increasing, cooling centers are considered an appropriate alternative to indoor cooling and a possible mitigation strategy to prevent adverse health impacts of heat exposure. However, these centers are limited in numbers and not always accessible. This requires (i) developing a geospatial framework using physical and social factors for optimal siting of cooling centers to meet future needs and (ii) ranking of existing and potential cooling centers (schools, libraries, religious institutions) based on their accessibility among vulnerable populations and proximity to healthcare facilities. We developed and deployed a geospatial framework based on the Multi-criteria Decision Analysis approach in five U.S. cities (Los Angeles (LA), Phoenix, Austin, Atlanta, Miami) to evaluate the effectiveness of the framework in ranking cooling centers based on accessibility and population coverage. The results revealed that (i) access to cooling centers varies across cities and 32.2–50.7% of centers are within walking distance of the most vulnerable populations, (ii) vulnerable populations exposed to Urban Heat Island (UHI) effects are more likely to experience energy burden, and (iii) about 21.2–49.4% of population with high energy burden have access to these centers. Considering that more cooling centers are needed to assist energy burdened households alleviate heat exposure impacts, the framework developed herein could be adapted to incorporate other factors (e.g. health impacts, policies) to assess site suitability of existing shelters, identify potential sites for new cooling centers, and geo-target communities where energy efficient emerging technologies could be deployed to reduce heat stress.

58 GEOSCIENCES↗

Phase II Field Demonstration at Lansing Smith Generating Plant, Southport, Florida (Final Report)

The Final Technical Report: Field Test Design and Pressure Management Strategies for Phase II Field Demonstration of Optimal Pressure Control, Plume Management, and Produced Water Strategies presents the culmination of multi-year efforts under the U.S. Department of Energy’s Brine Extraction and Storage Test (BEST) program, led by EPRI in partnership with Gulf Power at the Plant Smith site near Panama City, Florida. The project was designed to evaluate and demonstrate the technical feasibility of managing subsurface pressures and fluid movement associated with large-scale CO₂ injection, using low-salinity water as a proxy fluid. Through a combination of field injection testing, reservoir modeling, and optimization studies, the research team developed and refined active and passive brine extraction strategies aimed at controlling injection-induced pressure buildup, mitigating risks of fault activation, and managing plume migration. The field demonstration incorporated a new injection well (TIW-2), a new monitoring/extraction well (TEMW-A), and an existing well (TIW-1) repurposed for passive pressure relief. Complementary geophysical monitoring was designed to track plume development and evaluate the effectiveness of pressure management strategies. The report details the integrated workflow encompassing wellfield development, regulatory permitting, model calibration, and survey design. It includes a comprehensive electromagnetic (EM) modeling and inversion study used to develop a cost-effective, time-lapse geophysical monitoring plan capable of imaging the evolving low-salinity plume within the highly saline Lower Tuscaloosa formation. Reservoir simulation results guided the design of the 17-month injection program and the timing of active extraction to maintain formation pressures below a hypothetical fault reactivation threshold. Supporting analyses evaluated potential injectivity risks related to clay fines migration and geochemical incompatibility, identifying practical mitigation measures such as salinity and pH control. The final design recommends a series of crosswell EM surveys—conducted before, during, and after injection—as the most effective and economical approach for plume imaging, supplemented by continuous downhole pressure and flow monitoring. Collectively, the study provides a field-ready framework for cost-effective pressure management and monitoring in support of future CO₂ storage projects.

01 COAL, LIGNITE, AND PEAT↗

Crash Simulation of a Boeing 737 Fuselage Section Vertical Drop Test

A 30-ft/s vertical drop test of a fuselage section of a Boeing 737 aircraft was conducted in October of 1999 at the FAA Technical Center in Atlantic City, NJ. This test was performed to evaluate the structural integrity of a conformable auxiliary fuel tank mounted beneath the floor and to determine its effect on the impact response of the airframe structure and the occupants. The test data were used to compare with a finite element simulation of the fuselage structure and to gain a better understanding of the impact physics through analytical/experimental correlation. To perform this simulation, a full-scale 3-dimensional finite element model of the fuselage section was developed using the explicit, nonlinear transient-dynamic finite element code, MSC.Dytran. The emphasis of the simulation was to predict the structural deformation and floor-level acceleration responses obtained from the drop test of the B737 fuselage section with the auxiliary fuel tank.

Fasanella, Edwin L.↗

City Climate Action Plans Through the Lens of The Food-Energy-Water Nexus

Interdependent resource management concepts originated in the mid-20th century, and the recent use of the term “nexus” highlights interconnected relationships among resources like food, energy, and water. United States and European science foundations have shown a growing interest in the food-energy-water (FEW) nexus, leading to increased research on their joint management. However, one major criticism of the FEW nexus is the limited translation of the research into practical policies and implementation, such as climate action plans. To assess the incorporation of FEW nexus principles into climate planning, we systematically evaluate 100 climate action plans from large U.S. cities. Our findings show that the most discussed FEW links involve energy, particularly the water-for-energy and food-for-energy connections, found in over half of the documents (56%). Our analysis promotes the integration of the FEW nexus into climate action plans while addressing the barriers to its effective implementation.

Mounir, Adil [Air Force Institute of Technology]↗

Seasonal performance evaluation of zero-superheat active refrigerant charge control for variable-speed heat pumps

Heat pumps account for a significant portion of electricity consumption in buildings, making their energy efficiency a critical area of research. Control optimization is recognized as an effective approach for enhancing the efficiency of building HVAC systems. Specifically, since the efficiency of heat pumps increases with reduced superheat and the optimal refrigerant charge level varies with operating conditions, zero-superheat active charge control is a promising strategy to maximize the system’s COP. However, due to its complexity, this control strategy remains in the research phase and has only been tested under limited operating conditions. This paper proposes a methodology to evaluate the seasonal performance improvement of zero-superheat active charge control across a full range of heating conditions in buildings. The methodology includes the development of an optimal controller that utilizes an accumulator to store excess refrigerant and manages the active charge level at zero superheat through subcooling control, as well as the creation of a detailed physics-based heat pump model. Targeted a 3-ton variable-speed heat pump with R410A refrigerant, we selected ten U.S. cities representing different climate regions for seasonal performance evaluation. Our simulations indicate that, depending on the climate conditions, the optimal control strategy could achieve energy savings ranging from 5.8 % to 8.0 % over the entire heating season. These results suggest that zero-superheat active charge control, combined with coordinated compressor and fan speeds, could substantially improve the energy efficiency of heat pump systems while maintaining the required heating capacity.

Guo, Fangzhou↗

Expansion of Microbial Monitoring Capabilities on the International Space Station (ISS)

Microbial monitoring is one of the tools that the National Aeronautics and Space Administration (NASA) uses on the International Space Station (ISS) to help maintain crew health and safety. In combination with regular housekeeping and disinfection when needed, microbial monitoring provides important information to the crew about the quality of the environment. Rotation of astronauts, equipment, and cargo on the ISS can affect the microbial load in the air, surfaces, and water. The current ISS microbial monitoring methods are focused on culture-based enumeration during flight and require a significant amount of crew time as well as long incubation periods of up to 5 days there by proliferating potential pathogens. In addition, the samples require return to Earth for complete identification of the microorganisms cultivated. Although the current approach assess the quality of the ISS environment, molecular technology offers faster turn-around of information particularly beneficial in an off-nominal situation. In 2011, subject matter experts from industry and academia recommended implementation of molecular-based technologies such as quantitative real-time polymerase chain reaction (qPCR) for evaluation to replace current, culture-based technologies. The RAZOR EX (BioFire Defense, Inc, Salt Lake City, UT) a ruggedized, compact, COTS (commercial off the shelf) qPCR instrument was tested, evaluated and selected in the 2 X 2015 JSC rapid flight hardware demonstration initiative as part of the Water Monitoring Suite. RAZOR EX was launched to ISS on SpaceX-9 in July 2016 to evaluate the precision and accuracy of the hardware by testing various concentrations of DNA in microgravity compared to ground controls. Flight testing was completed between September 2016 and March 2017. Data presented will detail the hardware performance of flight testing results compared to ground controls. Future goals include additional operational ground-based testing and assay development to determine if this technology can meet spaceflight microbial monitoring requirements.

Khodadad, Christina L.↗

Building Energy Analysis of Manufactured and Multifamily Housing Types in Juneau, Alaska

This report details the results of building energy modeling analysis evaluating the potential energy savings, economic outcomes, and grid-level electricity reduction associated with cold climate air source heat pump (ccASHP) adoption across multifamily and manufactured housing (MMFH) building typologies in the City and Borough of Juneau (CBJ). Three building archetypes were evaluated: multifamily 4-plex apartments, multifamily 8-plex apartments, and manufactured housing units. Building energy models were developed using OpenStudio-HPXML and calibrated to actual utility consumption data and local meteorological data from the Juneau International Airport weather station using an automated calibration tool following the BPI-2400-S-2015 v.2 standard for model calibration. Occupant behaviors present the greatest variability in successful calibrations. Calibrated models were benchmarked against a baseline electric resistance heating condition, with the selected ccASHP modeled as the retrofit condition and typical meteorological year weather data for all results generation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Quantifying and simulating the weather forecast uncertainty for advanced building control

Weather forecast uncertainty is unavoidable despite technological advancements. Accurately quantifying and modelling this uncertainty is essential for developing and comparing advanced building controllers. In this study, we present a structured approach using a first-order autoregressive model (AR(1)) to model uncertainty in ambient temperature and global solar irradiation (GHI) forecasts. We analyzed weather data from four cities and employed Jensen–Shannon divergence (JSD) to evaluate the similarity between synthetic and actual forecast errors. The average JSD values for temperature are 0.027 (Berkeley), 0.021 (Leuven), 0.018 (Berlin), and 0.008 (Oslo), and for GHI, the average JSD values are 0.016 (Berkeley), 0.058 (Leuven), and 0.013 (Berlin). The low JSD values indicate a high similarity between the synthetic and real forecast error distributions. Further, our approach successfully generates synthetic weather forecasts that mirror the statistical properties of actual forecasts. The implementation of our method for uncertain forecast generation is being added to the BOPTEST framework.

54 ENVIRONMENTAL SCIENCES↗

The Feasibility of Establishing Operational Water Hyacinth-Based Systems at the Treatment Facilities of Existing Cities

The wastewater treatment facilities of three communities in southern Florida and two in southern Texas areas having populations of 20,000 or fewer persons were surveyed to determine: (1) their performance characteristics and the nature of their customers; (2) facility upgrading requirements needed to meet current and future EPA and State standards; (3) their adaptability to water hyacinth utilization and harvested plant disposal; and (4) the level of community support. Guidelines for site selection were established and applied to five cities in Texas and four in Florida. An evaluation of the prospective sites reveals that the Florida locations are generally unsuitable for implementation of water hyacinth based systems because of regulatory philosophy. All five Texas sites have excellent potential.

Source record↗

Premature Deaths Due to Heat Exposure: the Potential Effects of Neighborhood-Level Versus City-Level Acclimatization Within Us Cities

For the population of a given US city, the risk of premature death associated with heat exposure increases as temperatures rise, but risks in hotter cities are generally lower than in cooler cities at equivalent temperatures due to factors such as acclimatization. Those living in especially hot neighborhoods within cities might therefore suffer much more than average if such adaptation is only at the city-wide level, whereas they might not experience greatly increased risk if adjustment is at the neighborhood level. To compare these possibilities, we use high spatial resolution temperature data to evaluated heat-related deaths assuming either adjustment at the city-wide or at the neighborhood scale in 10 large US cities. On average, we find that if inhabitants are adjusted to their local conditions, a neighborhood that was 10°C hotter than a cooler one would experience only about 1.0–1.5 excess heat deaths per year per 100,000 persons. By contrast, if inhabitants are acclimatized to city-wide temperatures, the hotter neighborhood would experience about 15 excess deaths per year per 100,000 persons. Using idealized analyses, we demonstrate that current city-wide epidemiological data do not differentiate between these differing adjustments. Given the very large effects of assumptions about neighborhood-level acclimatization found here, as well as the fact that current literature is conflicting on the spatial scale of acclimatization, more neighborhood-level epidemiological data are urgently needed to determine the health impacts of variations in heat exposure within urban areas, better constrain projected changes, and inform mitigation efforts.

heat island↗

Plan evaluation for heat resilience: complementary methods to comprehensively assess heat planning in Tempe and Tucson, Arizona

Abstract Escalating impacts from climate change and urban heat are increasing the urgency for communities to equitably plan for heat resilience. Cities in the desert Southwest are among the hottest and fastest warming in the U.S., placing them on the front lines of heat planning. Urban heat resilience requires an integrated planning approach that coordinates strategies across the network of plans that shape the built environment and risk patterns. To date, few studies have assessed cities’ progress on heat planning. This research is the first to combine two emerging plan evaluation approaches to examine how networks of plans shape urban heat resilience through case studies of Tempe and Tucson, Arizona. The first methodology, Plan Quality Evaluation for Heat Resilience, adapts existing plan quality assessment approaches to heat. We assess whether plans meet 56 criteria across seven principles of high-quality planning and the types of heat strategies included in the plans. The second methodology, the Plan Integration for Resilience Scorecard™ (PIRS™) for Heat, focuses on plan policies that could influence urban heat hazards. We categorize policies by policy tool and heat mitigation strategy and score them based on their heat impact. Scored policies are then mapped to evaluate their spatial distribution and the net effect of the plan network. The resulting PIRS™ for Heat scorecard is compared with heat vulnerability indicators to assess policy alignment with risks. We find that both cities are proactively planning for heat resilience using similar plan and strategy types, however, there are clear and consistent opportunities for improvement. Combining these complementary plan evaluation methods provides a more comprehensive understanding of how plans address heat and a generalizable approach that communities everywhere could use to identify opportunities for improved heat resilience planning.

Environmental Sciences & Ecology↗

Ellicott City Disasters II - Building a Real-Time Predictive Flood Model for Improving Early Warning Systems in Ellicott City, Maryland

As flood events in the United States grow in frequency and intensity, the uses of applied remote sensing analyses are increasingly necessary for effective flood monitoring and warning systems. The NASA DEVELOP Ellicott City Disasters III project investigated the use of machine learning for applications in flood risk detection to support the improvement of early warning systems in Ellicott City, Maryland. To strengthen the efforts of the Howard County Office of Emergency Management (OEM) in building a more robust flood monitoring system, this term built on the predictive capability of the long-short term memory (LSTM) model created by the second term of this DEVELOP project to create a Sequentially Trained Real-time EstimAted Model (STREAM). Enhancements to the model included the integration of both real-time and predicted weather products from the National Weather Service to increase predictive capacity. These weather products were supplemented by stream gauge data from the OEM as well as real-time radar products. The resultant flood risk model was trained to evaluate input variables and predict stage height in Ellicott City in real time. The model, upgraded to predict stage height up to 8 hours in advance, was incorporated into an online dashboard in a user-friendly interface. The project demonstrated the potential for integration of open data and NASA Earth observations into a flood risk forecasting tool capable of informing real-time decision-making.

Erika Munshi↗

Ellicott City Disasters III: Building a Real-Time Statistical Flood Model for Improving Early Warning Systems in Ellicott City, Maryland

As flood events in the United States grow in frequency and intensity, the uses of applied remote sensing analyses are increasingly necessary for effective flood monitoring and warning systems. The NASA DEVELOP Ellicott City Disasters III project investigated the use of machine learning for applications in flood risk detection to support the improvement of early warning systems in Ellicott City, Maryland. To strengthen the efforts of the Howard County Office of Emergency Management (OEM) in building a more robust flood monitoring system, this term built on the predictive capability of the long-short term memory (LSTM) model created by the second term of this DEVELOP project to create a Sequentially Trained Real-time EstimAted Model (STREAM). Enhancements to the model included the integration of both real-time and predicted weather products from the National Weather Service to increase predictive capacity. These weather products were supplemented by stream gauge data from the OEM as well as real-time radar products. The resultant flood risk model was trained to evaluate input variables and predict stage height in Ellicott City in real time. The model, upgraded to predict stage height up to 8 hours in advance, was incorporated into an online dashboard in a user-friendly interface. The project demonstrated the potential for integration of open data and NASA Earth observations into a flood risk forecasting tool capable of informing real-time decision-making.

Erika Munshi↗

Ellicott City Disasters II: Enhancing a Statistical Flood Risk Model to Continue Improving Early Warning Systems and Public Safety in Ellicott City, Maryland

As flooding events in the United States grow in frequency and intensity, the use of technological advancements and applied science are increasingly necessary for effective flood monitoring and warning systems. The NASA DEVELOP Ellicott City Disasters II project investigated the use of machine learning for applications in flood risk detection to support the improvement of early warning systems. To strengthen the efforts of the Howard County Office of Emergency Management (OEM) in building a more robust flood monitoring system, the project improved the original statistical flood risk model, FLuME (Flood Learning Model Environment), programmed by the first DEVELOP term. The enhancements incorporated an additional six years of precipitation and soil moisture data from the North American Land Data Assimilation System (NLDAS), modeled using Aqua Advanced Microwave Scanning Radiometer for EOS and Tropical Rainfall Measuring Mission (TRMM) Microwave Imager. These Earth observations were supplemented by stream gauge data from the OEM and the US Geological Survey. The resultant flood risk model FLASH (Flood Learning Environment and Severity Assessment Hub) was trained to evaluate input variables and predict stage height in Ellicott City in real time. The addition of an advanced deep learning framework known as long short-term memory improved the model’s ability to capture relationships between variables. To assess the effectiveness of the new model, FLASH produced a model efficiency metric of 0.99, a significant improvement over the 0.85 value produced by the previous model. The project assisted the OEM in pursuing the integration of open data and NASA Earth observations into a threat matrix capable of informing near real-time decision making.

Disasters↗

Ellicott City Disasters II: Enhancing a Statistical Flood Risk Model to Continue Improving Early Warning Systems and Public Safety in Ellicott City, Maryland

As flooding events in the United States grow in frequency and intensity, the use of technological advancements and applied science are increasingly necessary for effective flood monitoring and warning systems. The NASA DEVELOP Ellicott City Disasters II project investigated the use of machine learning for applications in flood risk detection to support the improvement of early warning systems. To strengthen the efforts of the Howard County Office of Emergency Management (OEM) in building a more robust flood monitoring system, the project improved the original statistical flood risk model, FLuME (Flood Learning Model Environment), programmed by the first DEVELOP term The enhancements incorporated an additional six years of precipitation and soil moisture data from the North American Land Data Assimilation System (NLDAS), modeled using Aqua Advanced Microwave Scanning Radiometer for EOS and Tropical Rainfall Measuring Mission TRMM Microwave Imager. These Earth observations were supplemented by stream gauge data from the OEM and the US Geological Survey. The resultant flood risk model FLASH (Flood Learning Environment and Severity Assessment Hub) was trained to evaluate input variables and predict stage height in Ellicott City in real time. The addition of an advanced deep learning framework known as long short-term memory improved the model’s ability to capture relationships between variables. To assess the effectiveness of the new model, FLASH produced a model efficiency metric of 0.99, a significant improvement over the 0.85 value produced by the previous model. The project assisted the OEM in pursuing the integration of open data and NASA Earth observations into a threat matrix capable of informing near real-time decision making.

Disasters↗

New York City Panel on Climate Change 2019 Report Chapter 4: Coastal Flooding

Coastal flooding from storm surge is one of the most dangerous and damaging natural hazards that societies face. It was responsible for half of all hurricane related mortalities in the United States from 1963 to 2012, far more than any other factor. Coastal extreme water levels are increasing globally, mainly driven by rises in mean sea level. Sea level rise is also causing rapid increases in the annual number of shallow “nuisance floods” for low-lying neighborhoods. The objectives of this chapter are to review the latest knowledge on New York City flood risk from storms and tides, and to evaluate how climate change will affect this risk between now and the end of the century. Methods used by NPCC (2015) for assessing storm-driven extreme floods are generally repeated here, including the use of the Federal Emergency Management Agency (FEMA, 2013) baseline flood hazards (e.g., the 100-year flood(sup a)) and the methods for adding sea level rise and mapping the resulting hazard. New advancements include an innovative analysis of monthly tidal flooding based on a dynamic model, a broadened set of sea level rise scenarios supplemented with the Antarctic Rapid Ice Melt (ARIM) scenario (see Chapter 3), and sensitivity analyses that show how differing methods would affect our results. Wind is a primary factor for coastal storm surge, and a brief review is given in Appendix 4.A, with the latest scientific knowledge on what drives extreme wind events in the New York City area and how they may change in the future.

Orton, Philip↗