Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “circulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Endurance test of helium circulator for HTR-PM - 18531

High-temperature Gas-cooled Reactor Pebble-bed Module (HTR-PM) will be built as the world's first pebble-bed type modular HTGR commercial demonstration plant according to Chinese National science and technology program. HTR-PM will be expected to begin generating electricity in the end of 2017 in Shidao bay of China. Helium circulator is one of critical component of HTR-PM, which circulates reactor coolant through the reactor core and steam generators. The helium circulator was designed to be a vertical layout and its rotor was supported by active magnet bearings (AMBs). The whole circulator including motor and cooler was sealed in a pressure vessel. Since it is a large mechanical and electrical equipment and the design is totally advanced integrated with many new technologies, experiment study of helium circulator would be significant for safe and reliable operation of HTR-PM plant in the future. For the lack of engineering experience of this equipment, it was necessary to manufacture a prototype for tests. Meanwhile, Engineering Test Facility- Helium Circulator. ETF-HC was built in Institute of Nuclear and New Energy Technology (INET) for the tests. The prototype is completely same as the real machine for the plant. After prototype fabrication, nitrogen test was firstly conducted in the factory by the manufacturer, designer and users. After successful factory test, the prototype was delivered to INET to be tested in ETF-HC. Although nitrogen simulation test had been completed successfully, helium endurance test has been continually carried out in ETF-HC for one and half years because of several sealing problems caused by helium. After solving all kinds of problem in the field, helium circulator run continuously 50 hours under rated condition. Furthermore, 50 service cycles test was conducted in ETF-HC. More than 500 operation hours was accumulated during endurance test. Throughout the final performance test, a conclusion can be made that the helium circulator performance met the design requirements and its feasibility, availability and reliability was verified. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-Temperature Heat Transfer Fluid Circulator for Concentrating Solar Power Systems

Concentrating Solar Power (CSP) plants with Thermal Energy Storage (TES), require compressors capable of circulating supercritical carbon dioxide (sCO2) heat transfer fluids (HTFs) at temperatures from 500 to 700+°C and pressures from 8 to 25 MPa (80 to 250 Bar or 1160 to 3626 psia) in order to achieve thermal-to-electric efficiencies >50%. A review of papers relating to SCO2 compressors reveals that in almost every case the conditions being considered either allow for cooling of the SCO2 working fluid or are considering operating conditions close to the critical point at a temperature and pressure of approximately 31°C and 1070 psi). While the technology reported in these papers is relevant to most turbomachinery, the current CSP gas pathway circulator operating pressures are well above the CO2 critical point and do not allow for cooling of the main HTF flow. The purpose of this paper was to describe the key system issues affecting the design of a HTF circulator that could be scaled from a small size research and proof of concept circulator compressor to sizes supporting power plants producint upwards of 100 to 300 Mega Watts of electrical power. Due to the high temperatures and pressures the research scale HTF circulator was designed to be hermetically sealed to prevent leakage of the super critical carbon dioxide to the environment. In order to achieve hermetic sealing the drive motor and centrifugal impeller were fully integrated in a single shaft system configuration. From a preliminary assessment of compression power as a function of operating speed and impeller diameter it was determined that a smaller, higher speed impeller would result in a more efficient circulator. However, due to the high pressure and corresponding density of the sCO2 coupled with high operating speeds, large windage losses (i.e., viscous drag on the high speed rotating shaft) would occur which could result in a substantial reduction in efficiency of the system. Therefore tradoff studies were complerted to identify the operating speeds and system component sizes to achieve high efficiency. Based on the trade studies, the final design was a 55 mm diamter compressor impeller operating at speeds to 85,000 rpm. The unit will be built and tested in the future. Key Words: Super Critical Carbon Dioxide, Heat Transfer Fluid, Turbomachinery, Compressor, Circulator, Critical Point, Concentrating Solar Power, Solar Energy

Super Critical Carbon Dioxide, Heat Transfer Fluid↗

Validation of RELAP-7 for Forced Convective and Natural Circulation Reactor Flows

New reactor designs such as small modular reactors and newly proposed passive safety systems rely on natural circulation two-phase flow cooling of the reactor core under accident conditions. Without a pump to drive the flow, the circulation rate is a strong function of void fraction. Under these conditions where the flow rate, pressure drop, and heat transfer are all closely coupled through the mixture density, the accurate prediction of void fraction is pivotal. Furthermore, while these passive systems boast a more reliable cooling option, the sensitivity of the system to two-phase flow instabilities is more likely than in forced convective cooling and can result in dangerous density wave or flow excursion conditions. Improvement of one-dimensional system codes and further development of three-dimensional code capability are all important efforts in addressing these issues. The proposed work is a critical step towards providing confidence through validation of the capability of thermal-hydraulic tools to meet the emerging challenges in reactor simulation. Historically, system analysis codes develop a stiffness over time due to fine-tuning of adjustable code parameters that result in a reluctance or inability to adopt improved models. Therefore, a rigorous effort should be invested in preparation for RELAP-7 to identify required modeling improvements of constitutive relations and validation of the code applicability to the wide range of possible reactor flow conditions. Part of this validation involves the uncertainty quantification which is a critical step in the Code Scaling, Applicability, and Uncertainty (CSAU) methodology and Best-Estimate Plus Uncertainty (BEPU) licensing method. BEPU allows recovery of safety margins and potentially optimizing plant performance, resulting in economic benefit for the reactor operators. Beginning with the collection of past experimental data covering prototypic LWR conditions, this document reviews three critical datasets available for the validation of system codes. The experimental methods, procedures, facilities, instrumentation, and supplementary information are consolidated to aid the validation efforts of this work and future projects. These three datasets (824 conditions) are chosen due to their wide acceptance and demonstrated application for code validation. Two experimental datasets from the Nuclear Power Engineering Corporation (NUPEC) span prototypic conditions of Boiling Water Reactors (BWR) and Pressurized Water Reactors (PWR). These datasets are labeled as the BFBT (BWR Full-size Fine-mesh Bundle Test) and the PSBT (PWR Subchannel and Bundle Test) datasets respectively. The third dataset is taken in an internally heated annulus that is scaled based on a BWR subassembly and includes two-phase flows important to post-blowdown analysis. Together, the datasets consider the full range of pressure and mass flux expected in LWR forced convective flows from steady-state to long term cooling conditions. Recognizing the deficiency of available data under low-pressure, low-flow, a new natural circulation dataset consisting of 107 conditions is obtained. With system pressures ranging between 145 and 950 kPa, natural circulation is driven by a heat flux up to 275 kW/m2 in a 3 m long heated region of the annulus test section which is followed by a 2 m long unheated region before entering a condenser. Stable natural circulation flow rates in this facility were measured to be between 182 and 590 kg/m2-s. Pressure and temperature are measured at ten locations in the facility. In addition, measurements of void fraction, interfacial area concentration, and gas velocity are obtained at five axial locations in the annulus test section. The RELAP5-3D code demonstrates good accuracy for void fraction predictions in BFBT and PSBT benchmarks, but shows relatively large discrepancy in the annulus experiments at lower pressures. In two-phase natural circulation, large oscillations are observed in many system parameters during the simulation of 19 experiment cases which were conducted at low pressures, and the model shows good predictive performance with the remaining 88 experiment cases. However, some discrepancies in void fraction and temperature predictions are found which may require improved constitutive modeling under these low-pressure, low-flow condition. The quantified uncertainty in void fraction predictions in three forced convection benchmarks due to uncertainties in boundary conditions and geometries are relatively small, except for a few cases in the annulus experiment. The output uncertainty of the natural circulation model is quantified by considering the measurement error in boundary conditions, and it is shown that the output uncertainty ranges are relatively small for the range of conditions considered. Through this work, a clear pathway is provided for validation of RELAP7 once the code is available.

42 ENGINEERING↗

Optimization design of helium circulator diffuser in HTR-PM - 18488

Circulator is very important in HTR-PM. It needs to supply enough pressure rise to circulate cooled helium in the primary loop of HTR-PM to bring heat out. Its pressure rise requirement is the highest among the worldwide circulators. Diffuser is one main component to produce pressure rise for circulator. And the most particular for HTR-PM is that the helium must flow out from two round tubes after flowing through the diffuser, which is very different from other circulators. This special export structure increases flow loss and decreases diffuser efficiency. So it is necessary to optimize diffuser to satisfy high pressure rise requirement of HTR-PM circulator with the special export structure. Four geometrical variables of diffuser have been studied and optimized. Based on the flow and performance analysis, the optimum structure was chosen. Then the detailed simulation was done by combining it with impeller to obtain performance characteristics of the whole circulator. Finally, the simulation results were compared with experimental results. It was obtained that simulation pressure rise was 201 kPa and experimental result was 210 kPa, which verified that optimization design of diffuser was effective. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Validation of SAS4A/SASSYS-1 for predicting steady-state single-phase natural circulation

The validation of system analysis codes for nuclear reactor systems is required for the development and application of these computational tools. Designed as a comprehensive system analysis code for advanced nuclear reactors, SAS4A/SASSYS-1 requires validation of its physics model for capturing single-phase natural circulation behavior. To support the validation of SAS4A/SASSYS-1, high-precision experiments are performed capturing steady-state single-phase natural circulation on a scaled facility with comprehensive instrumentation. In this work, dedicated tests are performed quantifying the critical modeling parameters, and a single-phase natural circulation benchmark dataset is obtained with well-documented uncertainty and comprehensive facility description. The validation is then performed against the dataset examining the capability of SAS4A/SASSYS-1 in simulating steady-state single-phase natural circulation. The experimental facility is modeled in the candidate code. Solution verification is performed using Richardson-extrapolation-based estimators which quantify and restrict numerical errors from discretization. Input uncertainty provided by the benchmark dataset is forward propagated through the candidate code, quantifying the output uncertainty in a Monte Carlo approach. The composition of the output uncertainty is also quantified through a variance-based sensitivity analysis. With the uncertainty quantified for each individual condition, a detailed comparison between the simulation results and experimental data is performed covering the whole dataset. The results show consistent agreement for all primary parameters. The current validation activity provides a valuable benchmark dataset for the validation of system analysis codes in capturing single-phase natural circulation and demonstrates satisfactory prediction capability of SAS4A/SASSYS1 for steady-state single-phase natural circulation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Changes in atmospheric circulation amplify extreme snowfall fueled by Arctic sea ice loss over high-latitude land

Arctic sea-ice retreat has been linked to increased winter precipitation and heavy snowfall over land, likely due to a combination of enhanced evaporation from ice-free Arctic marginal seas (AMS) and changes in atmospheric circulation. However, their relative roles and contributions remain uncertain. Here, we show that a greater proportion of AMS evaporative moisture reached high-latitude land during the cold seasons from 1980–1989 to 2012–2021. Atmospheric circulation changes added an additional 13 % increase in the AMS moisture contribution, accounting for 11 % of the total increase in AMS-sourced land precipitation. Notably, 46 % of the increase in AMS-sourced extreme snowfall is attributed to circulation-driven landward moisture transport, representing an 84 % increase beyond the effect of enhanced AMS evaporation alone. Further analysis indicates that both the rise in Arctic moisture and the atmospheric circulation shifts are primarily driven by anthropogenic forcing. These findings highlight how atmospheric circulation changes amplify extreme snowfall fueled by AMS evaporation, underscoring the synergistic effects of Arctic sea ice loss and circulation change on high-latitude winter precipitation.

Anthropogenic forcing↗

Statistical analysis of dose heterogeneity in circulating blood: Implications for sequential methods of total body irradiation

Purpose: Improvements in delivery techniques for total body irradiation (TBI) using Tomotherapy and intensity modulated radiation therapy have been proven feasible. Despite the promise of improved dose conformality, the application of these ''sequential'' techniques has been hampered by concerns over dose heterogeneity to circulating blood. The present study was conducted to provide quantitative evidence regarding the potential clinical impact of this heterogeneity. Methods: Blood perfusion was modeled analytically as possessing linear, sinusoidal motion in the craniocaudal dimension. The average perfusion period for human circulation was estimated to be approximately 78 s. Sequential treatment delivery was modeled as a Gaussian-shaped dose cloud with a 10 cm length that traversed a 183 cm patient length at a uniform speed. Total dose to circulating blood voxels was calculated via numerical integration and normalized to 2 Gy per fraction. Dose statistics and equivalent uniform dose (EUD) were calculated for relevant treatment times, radiobiological parameters, blood perfusion rates, and fractionation schemes. The model was then refined to account for random dispersion superimposed onto the underlying periodic blood flow. Finally, a fully stochastic model was developed using binomial and trinomial probability distributions. These models allowed for the analysis of nonlinear sequential treatment modalities and treatment designs that incorporate deliberate organ sparing. Results: The dose received by individual blood voxels exhibited asymmetric behavior that depended on the coherence among the blood velocity, circulation phase, and the spatiotemporal characteristics of the irradiation beam. Heterogeneity increased with the perfusion period and decreased with the treatment time. Notwithstanding, heterogeneity was less than {+-}10% for perfusion periods less than 150 s. The EUD was compromised for radiosensitive cells, long perfusion periods, and short treatment times. However, the EUD was unaffected (within 10%) for perfusion periods of less than 150 s or treatment times of 20 min or greater. Treatment over six fractions improved the EUD per fraction such that all parametric combinations resulted in unaffected EUD. The stochastic models confirmed these results. Conclusions: Dose heterogeneity in circulating blood cells is clinically acceptable for typical treatment times, perfusion rates, and cell types. Development of conformal, sequential TBI treatment techniques should not be withheld based on concerns over circulating blood dose heterogeneity.

60 APPLIED LIFE SCIENCES↗

Circulating CD16+CD56+ nature killer cells indicate the prognosis of colorectal cancer after initial chemotherapy

As the prognosis of colorectal cancer (CRC) does not always coincide with the pathology and/or surgical findings, a reliable noninvasive prediction tool for the prognosis of CRC is needed. Patients admitted for initial treatment of CRC between January 1, 2015 and December 31, 2015 were retrieved and reviewed. Records of circulating CD16+ CD56+ natural killer (NK) cells were analyzed before and after the initial chemotherapy of FOLFOX plan. Patients were followed up until June 30, 2019. One hundred and twenty-four cases after the FOLFOX chemotherapy were enrolled into this study. There were no significant differences in gender, age, or number of metastasis cases between the survival group and the nonsurvival group (p > 0.05), but significant differences in pre-chemotherapy, post-chemotherapy, and the differences between pre- and post-chemotherapy circulating CD16+ CD56+ NK cells between the survival group and the nonsurvival group (p < 0.01, p < 0.01, and p < 0.05, respectively) were observed. For the prediction of survival and nonsurvival CRC cases, the Areas Under the Curve were 0.626 and 0.759 in the Receiver-Operating Characteristic curves for the pre- and post-chemotherapy circulating CD16+ CD56+NK cells, respectively. Using an optimal cutoff value of 11.8% in post-chemotherapy circulating CD16+CD56+NK cells to differentiate survival and nonsurvival cases, the odds ratio was 0.12 (0.05, 0.27), p < 0.001. The percentages of both pre-chemotherapy and post-chemotherapy circulating CD16+CD56+NK cells were negatively correlated with the prognosis of CRC. The percentage of post-chemotherapy circulating CD16+CD56+NK cells was able to effectively predict the prognosis of CRC cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Distinct non-invasive evaluation values of tumor-derived cell-free microRNAs, circulating microvesicles and exosomal microRNAs after renal carcinoma cryoablation

Highlights: • Circulating components could be used for the non-invasive evaluation of renal tumor cryoablation therapeutic effects. • Different circulating components have distinct roles in the evaluation of renal tumor cryoablation. • Exosomal microRNAs may be more suitable for the early postoperative judgment of tumor elimination effects. The detection of peripheral circulating tumor-derived components, such as cell-free microRNAs, circulating microvesicles, and exosomal microRNAs, has been shown as a promising noninvasive strategy. However, the different roles of these components in tumor therapy evaluations have remained largely undefined. In this paper, we employed an in vivo model of the human clear cell renal cell carcinoma line Caki-1-bearing mice to evaluate the therapeutic effects of cryoablation, which is a new minimally invasive treatment for renal cell carcinoma. At different times after cryoablation, we found that the levels of the cell-free microRNAs miR-122, miR-155 and miR-210 were first increased and then decreased. Additionally, the number of large-sized microvesicles was increased after cryoablation, but the number of small-sized circulating microvesicles did not change. Furthermore, the exosomal microRNAs miR-126–3p, miR-17–5p, and miR-21–3p rapidly decreased one day after cryoablation, an effect that was well correlated with the treatment degree. Therefore, we suggest that these circulating components may have different levels of importance in the evaluation of the efficacy of renal cell cryoablation, furthermore, exosomal microRNAs may be more suitable for the early postoperative judgment of tumor elimination effects, which are worth further exploration in clinical practice.

60 APPLIED LIFE SCIENCES↗

Orthologs of human circulating miRNAs associated with hepatocellular carcinoma are elevated in mouse plasma months before tumour detection

Research examining the potential for circulating miRNA to serve as markers for preneoplastic lesions or early-stage hepatocellular carcinoma (HCC) is hindered by the difficulties of obtaining samples from asymptomatic individuals. As a surrogate for human samples, we identified hub miRNAs in gene co-expression networks using HCC-bearing C3H mice. We confirmed 38 hub miRNAs as associated with HCC in F2 hybrid mice derived from radiogenic HCC susceptible and resistant founders. When compared to a panel of 12 circulating miRNAs associated with human HCC, two had no mouse ortholog and 7 of the remaining 10 miRNAs overlapped with the 38 mouse HCC hub miRNAs. Using small RNA sequencing data generated from serially collected plasma samples in F2 mice, we examined the temporal levels of these 7 circulating miRNAs and found that the levels of 4 human circulating markers, miR-122-5p, miR-100-5p, miR-34a-5p and miR-365-3p increased linearly as the time approaching HCC detection neared, suggesting a correlation of miRNA levels with oncogenic progression. Estimation of change points in the kinetics of the 4 circulating miRNAs suggested the changes started 17.5 to 6.8 months prior to HCC detection. These data establish these 4 circulating miRNAs as potential sentinels for preneoplastic lesions or early-stage HCC.

60 APPLIED LIFE SCIENCES↗

THE MEAN-FIELD SOLAR DYNAMO WITH A DOUBLE CELL MERIDIONAL CIRCULATION PATTERN

Recent helioseismology findings, as well as advances in direct numerical simulations of global dynamics of the Sun, have indicated that in each solar hemisphere meridional circulation may form more than one cell along the radius in the convection zone. In particular, recent helioseismology results revealed a double-cell structure of the meridional circulation. We investigate properties of a mean-field solar dynamo with such double-cell meridional circulation. The dynamo model also includes the realistic profile of solar differential rotation (including the tachocline and subsurface shear layer) and takes into account effects of turbulent pumping, anisotropic turbulent diffusivity, and conservation of magnetic helicity. Contrary to previous flux-transport dynamo models, we find that the dynamo model can robustly reproduce the basic properties of the solar magnetic cycles for a wide range of model parameters and circulation speeds. The best agreement with observations is achieved when the surface meridional circulation speed is about 12 m s{sup –1}. For this circulation speed, the simulated sunspot activity shows good synchronization with the polar magnetic fields. Such synchronization was indeed observed during previous sunspot Cycles 21 and 22. We compare theoretical and observed phase diagrams of the sunspot number and the polar field strength and discuss the peculiar properties of Cycle 23.

79 ASTRONOMY AND ASTROPHYSICS↗

Representation of Extratropical Cyclones, Blocking Anticyclones, and Alpine Circulation Types in Multiple Reanalyses and Model Simulations

Atmospheric circulation types, blockings, and cyclones are prime features of the extratropical flow and key to understanding the climate system. This study intercompares the representation of these features in 10 reanalyses and in an ensemble of 30 climate model simulations between 1980 and 2005. Both modern, full-input reanalyses and century-long, surface-input reanalyses are examined. Modern full-input reanalyses agree well on key statistics of blockings, cyclones, and circulation types. Yet, the intensity and depth of cyclones vary among them. Reanalyses with higher horizontal resolution show higher cyclone center densities and more intense cyclones. For blockings, no strict relationship is found between frequency or intensity and horizontal resolution. Full-input reanalyses contain more intense blocking, compared to surface-input reanalyses. Circulation-type classifications over central Europe show that both versions of the Twentieth Century Reanalysis dataset contain more easterlies and fewer westerlies than any other reanalysis, owing to their high pressure bias over northeast Europe. The temporal correlation of annual circulation types over central Europe and blocking frequencies over the North Atlantic–European domain between reanalyses is high (around 0.8). The ensemble simulations capture the main characteristics of midlatitudinal atmospheric circulation. Circulation types of westerlies to northerlies over central Europe are overrepresented. There are too few blockings in the higher latitudes and an excess of cyclones in the midlatitudes. Other characteristics, such as blocking amplitude and cyclone intensity, are realistically represented, making the ensemble simulations a rich dataset to assess changes in climate variability.

54 ENVIRONMENTAL SCIENCES↗

Validation of SAS4A/SASSYS-1 for Steady-State Single-Phase Natural Circulation

The development of numerical software for engineering applications requires the validation of the code against experimental benchmark datasets. To support the validation of SAS4A/SASSYS-1 in simulating the single-phase natural circulation within nuclear reactor systems, high-precision steady-state experiments are performed to capture single-phase natural circulation phenomena on an existing scaled facility with comprehensive instrumentation. Forced convection tests are designed precisely capturing the facility’s critical thermal-hydraulic parameters required for one-dimensional modeling, and a comprehensive single-phase natural circulation dataset is obtained with well-documented experimental uncertainty and facility description. Analysis and discussion based on the finalized dataset confirm the dataset’s ability in capturing dominant phenomena and address important physical interpretation of parameters. The dataset reported in this project provides a valuable benchmark resource for the validation of system analysis codes under single-phase natural circulation inside nuclear reactors. Validation of SAS4A/SASSYS-1 is then performed against the obtained benchmark dataset to confirm the capability of its physics model in simulating the steady-state single-phase natural circulation. The experimental facility is modeled in the candidate code. Solution verification is performed using Richardson-extrapolation-based estimators to quantify and restrict numerical errors from discretization. Numerical uncertainty originating from finite maximum pseudo-transient time is also quantified and restricted. Input uncertainty provided by the benchmark dataset is forward propagated through the candidate code, directly quantifying the simulation output in a Monte Carlo approach. The composition of the output uncertainty is further determined by the estimators of Sobol’ indices through a variance-based sensitivity analysis. With uncertainty quantified for each individual condition, detailed comparison between the simulation results and experimental data is performed covering the whole dataset, which shows consistent agreement for all important quantities. The validation activity reported in this project demonstrates that SAS4A/SASSYS-1 can predict the primary parameters with satisfactorily accuracy under steady-state single-phase natural circulation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Performance tests of helium circulator under abnormal cooling conditions - 18523

Helium circulator is one of the key equipment of High-temperature Gas-cooled Reactor Pebble-bed Module (HTR-PM) and the unique rotating equipment of primary loop. It transports heat generated by fission reactions from reactor core to steam generator by forcing helium circulating in primary loop. As the study on the characteristics of helium circulator in HTGR was limited and the advanced designs integrated with many new technologies, a prototype of helium circulator was manufactured. It was supported by Active Magnetic Bearings (AMBs), and was assembled in a pressure vessel. The prototype was tested in Engineering Test Facility - Helium Circulator (ETF-HC), which is a full scale, rated flow rate and power, engineering test loop. Although performance tests under normal operation condition were successfully fulfilled, the complete features and performance still need further verification, especially for abnormal cooling conditions. Thus performance tests under abnormal cooling operation conditions were carried out. Tests such as temporary coolant loss of motor and AMBs cooler and abnormal high-temperature cooling water condition were fulfilled. All performance tests results showed that helium circulator met the entire requirement of HTR-PM plant under abnormal cooling conditions and validated its safety and reliability. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Monolithic Integration of Self-Biased C -Band Circulator on SiC Substrate for GaN MMIC Applications

We have designed and fabricated the first self-biased circulator operating in C-band and monolithically integrated it with Qorvo's GaN MMIC technology by embedding a FeNi-based magnetic nanowire composite (MNC) in a 100 $μ$m thick SiC substrate. This integrated microstrip circulator shows a circulation frequency centered at 5.7 GHz, with an insertion loss of 2.7 dB and isolation of 14 dB. Additionally, the circulator demonstrated power handling of 9.6 W with continuous wave and at least 40W under pulsed conditions. This letter points a path in integrating miniaturized circulators into full-duplex GaN T/R MMICs with stringent form factor limits.

36 MATERIALS SCIENCE↗

The influence of variability in meridional over turning on global ocean circulation

The Atlantic Meridional Overturning circulation (AMOC) is an important global scale circulation and changes in AMOC can induce significant regional and global climate impacts. In this work, we study the stability of AMOC and its influence on global ocean circulation and the surface climate though analyzing a set of sensitivity experiments using the Community Climate System Model version 1 (CESM1). Results show that a collapsed AMOC can induce changes in global ocean circulation, such as reduced (or reversed) Bering Strait transport, weakened Indonesia throughflow and Agulhas current, but strengthened Drake Passage transport. It also changes the global wind pattern and surface temperature, such as a seesaw-like surface temperature change between Northern and Southern Hemispheres, a weakening of Indian-Australia summer monsoon, a southward shift of the Southern ocean westerlies, etc. We also found that AMOC and the Pacific deep meridional overturning circulation (or PMOC) do not form a natural seesaw under modern day climate and geography. A collapsed AMOC (active PMOC) is not stable under modern conditions if there is no additional freshwater (salt) input in the subpolar North Atlantic (Pacific), suggesting that the modern mean state of AMOC (PMOC) does not depend on local haline forcing although its variability and changes do.

54 ENVIRONMENTAL SCIENCES↗

Potential alteration of fjordal circulation due to a large floating structure—Numerical investigation with application to Hood Canal basin in Puget Sound

Circulation in typical fjords is characterized by a shallow brackish layer at the surface over a deep long and narrow saltwater column. This surface layer is responsible for the outflow of water from the fjord, is easily disrupted by external forces, such as wind, and is influenced by freshwater inflow. In this paper, we postulate that the stability of fjordal circulation may also be vulnerable to impacts from anthropogenic alterations, such as floating structures, that could constrict the mixing and transport in the upper layers of the water column. The potential for alteration of circulation in Hood Canal, a silled-fjord located inside Puget Sound, Washington, has been examined. Using classical analytical treatments along the lines formulated by Hansen and Rattray [1965], Rattray [1967], Dyer [1973] and more recently, MacCready [2004], we develop a solution applicable to a range of estuary classifications varying from a partially mixed estuary regime to classical fjord conditions. Both estuary types exist in the Puget Sound system, and we compare our analytical solution with observed data. The analysis is based on an exponential variation of eddy viscosity with depth, and it has been extended further with modifications of the free surface boundary conditions to develop a solution representing the presence of a floating bridge at the estuary/fjord entrance. The model results show that tidally averaged mean circulation under the influence of such a constraint could reduce by as much as 30 to 50 percent. The overall water quality of fjords and narrow estuaries is dependent on net circulation and flushing. A potential decrease in residual flow or a corresponding increase in residence time of this magnitude merits further study.

3D hydrodynamic model, Unstructured grid, FVCOM, F↗

Time-dependent thermal degradation of lost circulation materials in geothermal systems

Treatment of lost circulation can represent anywhere from 5 to 25 % of the cost in drilling geothermal wells. The cost of the materials used for lost circulation treatment is less important than their effectiveness at reducing fluid losses. In geothermal systems, the high temperatures (>90 °C) are expected to degrade many commonly used lost circulation materials over time. This degradation could compromise different materials ability to mitigate fluid loss, creating more non-productive time as multiple treatments are needed, but may result in recovering desired permeability zones within the reservoir section over time. This research aimed to study how thermal degradation of eight different lost circulation materials affected their properties relevant to sealing loss zones in geothermal wells. Here, mass loss experiments were conducted with each material at temperatures of 90–250 °C for 1–42 days to measure the breakdown of the material at geothermal conditions, collecting gases during several experiments to determine the waste produced during degradation. Compaction experiments were conducted with the degraded materials to show how temperatures reduced the rigidity and increased packing of the materials. Viscosity tests were conducted to show the impact of different materials on drilling fluid rheology. Microscope observations were conducted to characterize the alterations to each material due to thermal degradation. Organic materials tend to degrade more than inorganic materials, with organics like microcellulose, cotton seed hulls and sawdust losing 30–50 % of their mass after 1 day of heating at 200 °C, while inorganics like magma fiber only lose ~5–10 % of its mass after one day of heating at 200 °C. Granular materials are the strongest when compacted despite any mass loss, while fibrous and flaky materials are fairly weak and breakdown easily under stress. The materials do not generally affect fluid rheology unless they have a viscosifying agent as part of the mixture. Microscopic analysis showed that more rigid materials like microcellulose and cedar fiber degrade in brittle manners with splitting and fracturing, while others like cotton seed hulls degrade in more ductile manners forming meshes or clumps of material. The thermal breakdown of lost circulation materials tested suggests that each material should also be classified by its degree of thermal degradability, as at certain temperatures the materials can lose the capability to bridge loss zones around the wellbore.

15 GEOTHERMAL ENERGY↗