Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cascade control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Duty-Cycle Predictive Control of Quasi-Z-Source Modular Cascaded Converter Based Photovoltaic Power System

A duty-cycle predictive control is proposed for dc grid integration of front-end isolated quasi-Z-source modular cascaded converter (qZS-MCC) photovoltaic (PV) power system. The post-stage qZS half-bridge dc-dc converter deals with PV maximum power point tracking, dc grid integration, and dc-link voltage balance; whereas, the front-end isolation converters operate at a constant duty cycle of 50%. Thus, it saves control hardware resources while overcoming challenges from PV-panel voltage variations and dc-bus voltage limit. The proposed control uses the derived circuit model to predict the global active-state duty cycle for grid-connected current control and predict the shoot-through duty cycles for dc-link voltage balance, achieving a fast and accurate tracking target. The proposed control method has advantages of: i) eliminating weighting factors that exist in conventional model predictive control (MPC), ii) no sophisticated loop parameters design that exists in proportional-integral (PI) control, iii) operating at constant switching frequency that is different from the conventional MPC with variable switching frequency. Simulation and experimental tests are carried out to verify the effectiveness of the proposed control method and compare with the PI-based control system.

42 ENGINEERING↗

Exciton Dynamics in Layered Halide Perovskite Light‐Emitting Diodes

Abstract Layered halide perovskites have garnered significant interest due to their exceptional optoelectronic properties and great promises in light‐emitting applications. Achieving high‐performance perovskite light‐emitting diodes (PeLEDs) requires a deep understanding of exciton dynamics in these materials. This review begins with a fundamental overview of the structural and photophysical properties of layered halide perovskites, then delves into the importance of dimensionality control and cascade energy transfer in quasi‐2D PeLEDs. In the second half of the review, more complex exciton dynamics, such as multiexciton processes and triplet exciton dynamics, from the perspective of LEDs are explored. Through this comprehensive review, an in‐depth understanding of the critical aspects of exciton dynamics in layered halide perovskites and their impacts on future research and technological advancements for layered halide PeLEDs is provided.

Baek, Sung‐Doo↗

Failure Probability Constrained AC Optimal Power Flow

Despite cascading failures being the central cause of blackouts in power transmission systems, existing operational and planning decisions are made largely by ignoring their underlying cascade potential. This paper posits a reliability-aware AC Optimal Power Flow formulation that seeks to design a dispatch point which has a low operator-specified likelihood of triggering a cascade starting from any single component outage. By exploiting a recently developed analytical model of the probability of component failure, our Failure Probability-constrained ACOPF (FP-ACOPF) utilizes the system's expected first failure time as a smoothly tunable and interpretable signature of cascade risk. Here, we use techniques from bilevel optimization and numerical linear algebra to efficiently formulate and solve the FP-ACOPF using off-the-shelf solvers. Extensive simulations on the IEEE 118-bus case show that, when compared to the unconstrained and N-1 security-constrained ACOPF, our probability-constrained dispatch points can significantly lower the probabilities of long severe cascades and of large demand losses, while incurring only minor increases in total generation costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frequency and Phase-lock Control of a 3 THz Quantum Cascade Laser

We have locked the frequency of a 3 THz quantum cascade laser (QCL) to that of a far-infrared gas laser with a tunable microwave offset frequency. The locked QCL line shape is essentially Gaussian, with linewidths of 65 and 141 kHz at the -3 and -10 dB levels, respectively. The lock condition can be maintained indefinitely, without requiring temperature or bias current regulation of the QCL other than that provided by the lock error signal. The result demonstrates that a terahertz QCL can be frequency controlled with l-part-in-lO(exp 8) accuracy, which is a factor of 100 better than that needed for a local oscillator in a heterodyne receiver for atmospheric and astronomic spectroscopy.

Betz, A. L.↗

Long duration biaxial cylinder testing of balloon grade polyethylene films with emphasis on automated data acquisition and control

Characterization of a 2-dimensional material constitutive model in the practical biaxial state for engineering utility of balloon envelope structural analysis is achievable with laboratory cylinder tests. Hoop (circumferential, and longitudinal strains are time-wise measured on axially loaded pressurized cylinders. Pre-programmed ramped loading changes as well as precise long term pressure control are achieved through cascaded proportional, integral derivative (PID) flow control loops that are part of an integrated data acquisition and process control system. Real time data reduction and analysis allow monitoring of unattended tests that have durations of up to a month. Measured and controlled parameters and variables are discussed; date analysis techniques are reviewed.

Martone, Michael↗

Metasurface-assisted 3D beam shaping for desired phase, amplitude, and polarization

Cascaded metasurfaces can control the phase, amplitude and polarization of an electromagnetic beam, shaping it in three dimensional configuration not achievable with other methods. Each cascaded metasurface has dielectric or metallic scatterers arranged in a period array. The shape of the scatterers determines the three dimensional configuration of the output beam and is determined with iterative calculations through computational simulations.

Kamali, Seyedeh Mahsa↗

Metasurface-assisted 3D beam shaping using array of scatterers

Cascaded metasurfaces can control the phase, amplitude and polarization of an electromagnetic beam, shaping it in three dimensional configuration not achievable with other methods. Each cascaded metasurface has dielectric or metallic scatterers arranged in a period array. The shape of the scatterers determines the three dimensional configuration of the output beam and is determined with iterative calculations through computational simulations.

Kamali, Seyedeh Mahsa↗

Documentation and Control of Flow Separation on a Low Pressure Turbine Linear Cascade of Pak-B Blades Using Plasma Actuators

This work involved the documentation and control of flow separation that occurs over low pressure turbine (LPT) blades at low Reynolds numbers. A specially constructed linear cascade was utilized to study the flow field over a generic LPT cascade consisting of Pratt & Whitney "Pak-B" shaped blades. Flow visualization, surface pressure measurements, LDV measurements, and hot-wire anemometry were conducted to examine the flow fields with and without separation control. Experimental conditions were chosen to give a range of chord Reynolds numbers (based on axial chord and inlet velocity) from 10,000 to 100,000, and a range of freestream turbulence intensities from u'/U(infinity) = 0.08 to 2.85 percent. The blade pressure distributions were measured and used to identify the region of separation that depends on Reynolds number and the turbulence intensity. Separation control was performed using dielectric barrier discharge (DBD) plasma actuators. Both steady and unsteady actuation were implemented and found to work well. The comparison between the steady and unsteady actuators showed that the unsteady actuators worked better than the steady ones. For the steady actuators, it was found that the separated region is significantly reduced. For the unsteady actuators, where the signal was pulsed, the separation was eliminated. The total pressure losses (a low Reynolds number) was reduced by approximately a factor of two. It was also found that lowest plasma duty cycle (10 percent in this work) was as effective as the highest plasma duty cycle (50 percent in this work). The mechanisms of the steady and unsteady plasma actuators were studied. It was suggested by the experimental results that the mechanism for the steady actuators is turbulence tripping, while the mechanism for the unsteady actuators is to generate a train of spanwise structures that promote mixing.

Corke, Thomas c.↗

An error control system with multiple-stage forward error corrections

A robust error-control coding system is presented. This system is a cascaded FEC (forward error control) scheme supported by parity retransmissions for further error correction in the erroneous data words. The error performance and throughput efficiency of the system are analyzed. Two specific examples of the error-control system are studied. The first example does not use an inner code, and the outer code, which is not interleaved, is a shortened code of the NASA standard RS code over GF(28). The second example, as proposed for NASA, uses the same shortened RS code as the base outer code C2, except that it is interleaved to a depth of 2. It is shown that both examples provide high reliability and throughput efficiency even for high channel bit-error rates in the range of 0.01.

Takata, Toyoo↗

Comprehensive AI-based System for Control, Sensor Estimation, and Fault Detection of Cascaded Multilevel Inverters

In this paper, an Artificial Intelligence-based (AI) system is proposed for an 11-level cascaded H-bridge multilevel inverter (MLI) with the aims of harmonic suppression and reliability enhancement. The system consists of three seamlessly integrated Neural Networks (NNs). First, a multilayer perceptron is used to generalize the optimal switching angles for selective harmonic elimination under non-equal DC voltages. Next, an autoencoder NN estimates the voltage sensor readings to address potential drifting. Finally, a perceptron NN detects inverter faults based solely on the output voltage of the MLI. Simulation scenarios were evaluated, and the results show that the proposed system provides a comprehensive solution for the robust operation of the MLI. The proposed solution is capable of minimizing the targeted harmonics orders with minimal impact on the fundamental voltage, even when the voltage sensor drifts. Furthermore, the inverter under fault conditions was successfully identified.

Rezende da Costa Reis Kimpara, Renata↗

Precision-controlled ultrafast electron microscope platforms. A case study: Multiple-order coherent phonon dynamics in 1T-TaSe2 probed at 50 fs–10 fm scales

We report on the first detailed beam tests attesting the fundamental principle behind the development of high-current-efficiency ultrafast electron microscope systems where a radio frequency (RF) cavity is incorporated as a condenser lens in the beam delivery system. To allow for the experiment to be carried out with a sufficient resolution to probe the performance at the emittance floor, a new cascade loop RF controller system is developed to reduce the RF noise floor. Temporal resolution at 50 fs in full-width-at-half-maximum and detection sensitivity better than 1% are demonstrated on exfoliated 1T-TaSe2 system under a moderate repetition rate. To benchmark the performance, multi-terahertz edge-mode coherent phonon excitation is employed as the standard candle. The high temporal resolution and the significant visibility to very low dynamical contrast in diffraction signals via high-precision phase-space manipulation give strong support to the working principle for the new high-brightness femtosecond electron microscope systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Equivalent-Circuit Models of Grid-Forming IBRs for Electromagnetic-Transient Simulations

We derive equivalent-circuit models of control- and physical-layer subsystems of grid-forming (GFM) inverter-based resources (IBRs) for electromagnetic-transient (EMT) simulations. Three different primary controllers are considered: Droop, Virtual Synchronous Machine (VSM), and dispatchable Virtual Oscillator Control (dVOC). In addition, the models include cascaded voltage- and current-control loops, and LCL output filters. Simulations for a single-inverter setup and for a network of five inverters in a modified IEEE 14-bus topology are presented. The equivalent-circuit models simulated with analog electronic circuit-simulator software (in our case, LTspice) offer the same accuracy, and with no explicit tuning of the solver, lower computational burden compared to block-diagram-based implementations in commercial off-the-shelf EMT software (in our case, MATLAB-Simulink).

electromagnetic transient simulation↗

Equivalent-Circuit Models of Grid-Forming IBRs for Electromagnetic-Transient Simulations: Preprint

We derive equivalent-circuit models of control- and physical-layer subsystems of grid-forming (GFM) inverter-based resources (IBRs) for electromagnetic-transient (EMT) simulations. Three different primary controllers are considered: droop, virtual synchronous machine (VSM), and dispatchable virtual oscillator control (dVOC). In addition, the models include cascaded voltage- and current-control loops, and LCL output filters. Simulations for a single-inverter setup and for a network of five inverters in a modified IEEE 14-bus topology are presented. The equivalent-circuit models simulated with analog electronic circuit-simulator software (in our case, LTspice) offer the same accuracy with up to 150x lower computational burden compared to block-diagram-based implementations in commercial off-the-shelf EMT software (in our case, MATLAB-Simulink).

circuit-equivalent model↗

SiC-Based 5-kV Universal Modular Soft-Switching Solid-State Transformer (M-S4T) for Medium-Voltage DC Microgrids and Distribution Grids

Medium-voltage DC (MVDC) grids are attractive for electric aircraft and ship power systems, battery energy storage system (BESS), fast charging electric vehicle (EV), etc. Such EV or BESS applications need isolated bidirectional MVDC to LVDC or LVAC converters. However, the existing Si-based solutions cannot fulfill the requirements of a high-efficiency and robust converter for MVDC grids. This paper presents a 5 kV SiC-based universal modular solid-state transformer (SST). This universal current-source SST can interface either a LVAC or LVDC grid with a MVDC grid in single-stage power conversion, while the conventional dual active bridge (DAB) converter needs an additional inverter. The proposed SST module using 3.3 kV SiC MOSFETs and diodes is bidirectional and can serve as a building block in series or parallel for higher-voltage higher-power systems. The topology of each module is based on the soft-switching solid-state transformer (S4T) with reduced conduction loss, which features reduced EMI through controlled dv/dt, and high efficiency with full-range ZVS for main devices and ZCS for auxiliary devices. Operation principle of the modular S4T (M-S4T), capacitor voltage balancing control between the cascaded modules, design of components including a medium-voltage (MV) medium-frequency transformer (MFT) to realize a 50 kVA 5 kV DC to 600 V DC or 480 V AC M-S4T are presented. Importantly, the MV MFT prototype achieves very low leakage inductance (0.13%) and 15 kV insulation with coaxial cables and nanocrystalline cores. Here, the proposed universal modular SST is compared against the DAB solution and verified with DC-DC and DC-AC simulation and 4 kV experimental results. Significantly, the MV experimental results of a modular DC transformer with each module at MVDC are rarely covered in the literature and reported for the first time.

14 SOLAR ENERGY↗

Band-elimination filter

Helical resonator is employed to produce stable, highly selective filter. Other features of filter include controlled bandwidth by cascading identical stages and stagger tuning, adjustable notch depth, good isolation between stages, gain set by proper choice of resistors, and elimination of spurious responses.

Shelton, G. B.↗