Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “capillary pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Compressed CO2 Hard Rock Drill for Mars

We have developed a down-the-hole (DTH) rotary-percussive drill prototype that could operate on compressed Mars atmospheric CO2 gas with a wireline drilling approach. This technology addresses a need for more aggressive sampling and drilling techniques, for both scientific purposes and to obtain In-Situ Resource Utilization (ISRU) resources for future NASA missions and human crew support. Using a spool of lightweight, high-pressure capillary, a DTH drill assembly would be moved in and out of the hole that could be a kilometer or more in depth. The CO2 drill is designed so that Mars atmospheric CO2 could be collected, compressed, and supplied down the hole and routed through microducts, valves, and reservoirs for the purpose of controlling miniature mechanical actuation in the assembly. By using compressed CO2, the drill system avoids the need for heavy electrical cabling and actuator systems or a liquid media for carrying away particulates as is typically used in terrestrial drilling systems. Instead, the liquid CO2 that powers the drill expands to a gas and could be channeled around the drill housing to carry cuttings to be collected in a bailing bucket. Where terrestrial systems often use drill depth vs time as a metric, a Mars drilling system would need to be extremely low mass, but would have no need to perform under tight schedules. In this paper, we will document our trade studies, progression for the design of microduct logic verified through multiple generations of prototypes, and provide predictive performance data on energy consumption, hole depth, and drill time.

Wilcox, Brian↗

Compressed CO2 Hard Rock Drill for Mars

We have developed a down-the-hole (DTH) rotary-percussive drill prototype that could operate on compressed Mars atmospheric CO2 gas with a wireline drilling approach. This technology addresses a need for more aggressive sampling and drilling techniques, for both scientific purposes and to obtain In-Situ Resource Utilization (ISRU) resources for future NASA missions and human crew support. Using a spool of lightweight, high-pressure capillary, a DTH drill assembly would be moved in and out of the hole that could be a kilometer or more in depth. The CO2 drill is designed so that Mars atmospheric CO2 could be collected, compressed, and supplied down the hole and routed through microducts, valves, and reservoirs for the purpose of controlling miniature mechanical actuation in the assembly. By using compressed CO2, the drill system avoids the need for heavy electrical cabling and actuator systems or a liquid media for carrying away particulates as is typically used in terrestrial drilling systems. Instead, the liquid CO2 that powers the drill expands to a gas and could be channeled around the drill housing to carry cuttings to be collected in a bailing bucket. Where terrestrial systems often use drill depth vs time as a metric, a Mars drilling system would need to be extremely low mass, but would have no need to perform under tight schedules. In this paper, we will document our trade studies, progression for the design of microduct logic verified through multiple generations of prototypes, and provide predictive performance data on energy consumption, hole depth, and drill time.

Wilcox, Brian↗

Micro-Textured Black Silicon Wick for Silicon Heat Pipe Array

Planar, semiconductor heat arrays have been previously proposed and developed; however, this design makes use of a novel, microscale black silicon wick structure that provides increased capillary pumping pressure of the internal working fluid, resulting in increased effective thermal conductivity of the device, and also enables operation of the device in any orientation with respect to the gravity vector. In a heat pipe, the efficiency of thermal transfer from the case to the working fluid is directly proportional to the surface area of the wick in contact with the fluid. Also, the primary failure mechanism for heat pipes operating within the temperature range of interest is inadequate capillary pressure for the return of fluid from the condenser to the wick. This is also what makes the operation of heat pipes orientation-sensitive. Thus, the two primary requirements for a good wick design are a large surface area and high capillary pressure. Surface area can be maximized through nanomachined surface roughening. Capillary pressure is largely driven by the working fluid and wick structure. The proposed nanostructure wick has characteristic dimensions on the order of tens of microns, which promotes menisci of very small radii. This results in the possibility of enormous pumping potential due to the inverse proportionality with radius. Wetting, which also enhances capillary pumping, can be maximized through growth of an oxide layer or material deposition (e.g. TiO2) to create a superhydrophilic surface.

Yee, Karl Y.↗

Deterioration of left ventricular chamber performance after bed rest : "cardiovascular deconditioning" or hypovolemia?

BACKGROUND: Orthostatic intolerance after bed rest is characterized by hypovolemia and an excessive reduction in stroke volume (SV) in the upright position. We studied whether the reduction in SV is due to a specific adaptation of the heart to head-down tilt bed rest (HDTBR) or acute hypovolemia alone. METHODS AND RESULTS: We constructed left ventricular (LV) pressure-volume curves from pulmonary capillary wedge pressure and LV end-diastolic volume and Starling curves from pulmonary capillary wedge pressure and SV during lower body negative pressure and saline loading in 7 men (25+/-2 years) before and after 2 weeks of -6 degrees HDTBR and after the acute administration of intravenous furosemide. Both HDTBR and hypovolemia led to a similar reduction in plasma volume. However, baseline LV end-diastolic volume decreased by 20+/-4% after HDTBR and by 7+/-2% after hypovolemia (interaction P<0.001). Moreover, SV was reduced more and the Starling curve was steeper during orthostatic stress after HDTBR than after hypovolemia. The pressure-volume curve showed a leftward shift and the equilibrium volume of the left ventricle was decreased after HDTBR; however, after hypovolemia alone, the curve was identical, with no change in equilibrium volume. Lower body negative pressure tolerance was reduced after both conditions; it decreased by 27+/-7% (P<0.05) after HDTBR and by 18+/-8% (P<0.05) after hypovolemia. CONCLUSIONS: Chronic HDTBR leads to ventricular remodeling, which is not seen with equivalent degrees of acute hypovolemia. This remodeling leads to a greater decrease in SV during orthostatic stress after bed rest than hypovolemia alone, potentially contributing to orthostatic intolerance.

NASA Discipline Cardiopulmonary↗

Capillary electrophoresis: Imaging of electroosmotic and pressure driven flow profiles in fused silica capillaries

This study is a continuation of the summer of 1994 NASA/ASEE Summer Faculty Fellowship Program. This effort is a portion of the ongoing work by the Biophysics Branch of the Marshall Space Flight Center. The work has focused recently on the separation of macromolecules using capillary electrophoresis (CE). Two primary goals were established for the effort this summer. First, we wanted to use capillary electrophoresis to study the electrohydrodynamics of a sample stream. Secondly, there was a need to develop a methodology for using CE for separation of DNA molecules of various sizes. In order to achieve these goals we needed to establish a procedure for detection of a sample plug under the influence of an electric field Detection of the sample with the microscope and image analysis system would be helpful in studying the electrohydrodynamics of this stream under load. Videotaping this process under the influence of an electric field in real time would also be useful. Imaging and photography of the sample/background electrolyte interface would be vital to this study. Finally, detection and imaging of electroosmotic flow and pressure driven flow must be accomplished.

Williams, George O., Jr.↗

An Experimental Study of Pressure Oscillation in a Capillary Pumped Loop with Multiple Evaporators and Condensers

The heat transport capability of a capillary pumped loop (CPL) is limited by the pressure drop that its evaporator wick can sustain. The pressure drop in a CPL is not constant even under seemingly steady operation, but rather exhibits an oscillatory behavior. A hydrodynamic theory based on a mass-spring-dashpot model was previously developed to predict the pressure oscillation in a CPL with a single evaporator and a single condenser. The theory states that the pressure oscillation is a function of physical dimensions of the CPL components and operating conditions. Experimental data agreed very well with theoretical predictions. The hydrodynamic stability theory has recently been extended to predict the pressure oscillations in CPLs with multiple evaporators and multiple condensers. Concurrently, an experimental study was conducted to verify the theory and to investigate the effects of various parameters on the pressure oscillation. Four evaporators with different wick properties were tested using a test loop containing two condenser plates. The test loop allowed the four evaporators to be tested in a single-pump, two-pump or four-pump configuration, and the two condenser plates to be plumbed either in parallel or in series. Test conditions included varying the power input, the reservoir set point temperature, the condenser sink temperature, and the flow resistance between the reservoir and the loop. Experimental results agreed well with theoretical predictions.

Ku, Jen-Tung↗

Recent bed rest results and countermeasure development at NASA

Bedrest studies of normal subjects provide opportunities to understand physiologic responses to supine posture and inactivity. Furthermore, head-down tilt has been a valuable procedure to investigate adaptation to microgravity and development of countermeasures to maintain the health and well-being of humans during space-flight. Recent bedrest experiments at NASA have ranged in duration from a few hours to 17 weeks. Acute studies of 6 degrees head-down tilt indicate that elevation of capillary blood pressure from 28 to 34 mm Hg and increased capillary perfusion in tissues of the head cause facial and intracranial edema. Intracranial pressure increases from 2 to 17 mm Hg going from upright posture to 6 degrees head-down tilt. Microvessels of the head have a low capacity to constrict and diminish local perfusion. Elevation of blood and tissue fluid pressures/flow in the head may also explain the higher headward bone density associated with long-term head-down tilt. These mechanistic studies of head-down tilt, along with a better understanding of the relative stresses involved with upright posture and lower body negative pressure, have facilitated development of suitable physiologic countermeasures to maintain astronaut health during microgravity. Presently no exercise hardware is available to provide a blood pressure gradient from head to feet in space. However, recent studies in our laboratory suggest that treadmill exercise using a graded lower-body compression suit and 100 mmHg lower body negative pressure provides equivalent or greater physiologic stress than similar upright exercise on Earth. Therefore, exercise within a lower body negative pressure chamber may provide a cost-effective and simple countermeasure to maintain the cardiovascular and neuro-musculoskeletal systems of astronauts during long-duration flight.

manned↗

Measurements of capillary system degradation

The effects of vibration, flow transients, and warm gas pressurization on capillary acquisition system performance were evaluated. The degradation observed under wide band random and high frequency sinusoidal vibration was of a substantially different nature from that obtained under low frequency sinusoidal vibration. With the former, ingestion of small gas bubbles into the liquid region was correlated by a hydrostatic model, while the capillary stability was destroyed and liquid was lost from the liquid region with the latter. No degradation was observed as a result of flow transients in a flight-type multichannel screen device, but it was observed in a transparent laboratory device. Liquid hydrogen outflow tests were conducted with a multilayer dual-screen-liner system with both helium and hydrogen pressurant gases. The tendency towards dryout of the device with hydrogen pressurant was found to increase with increasing pressurant temperature and length of prepressurization period. Dryout did not occur with helium pressurant.

Warren, R. P.↗

Chronic mitral regurgitation and Doppler estimation of left ventricular filling pressures in patients with heart failure

Previous studies relating Doppler parameters and pulmonary capillary wedge pressures (PCWP) typically exclude patients with severe mitral regurgitation (MR). We evaluated the effects of varying degrees of chronic MR on the Doppler estimation of PCWP. PCWP and mitral Doppler profiles were obtained in 88 patients (mean age 55 +/- 8 years) with severe left ventricular (LV) dysfunction (mean ejection fraction 23% +/- 5%). Patients were classified by severity of MR. Patients with severe MR had greater left atrial areas, LV end-diastolic volumes, and mean PCWPs and lower ejection fractions (each P <.01). In patients with mild MR, multiple echocardiographic parameters correlated with PCWP; however, with worsening MR, only deceleration time strongly related to PCWP. From stepwise multivariate analysis, deceleration time was the best independent predictor of PCWP overall, and it was the only predictor in patients with moderate or severe MR. Doppler-derived early mitral deceleration time reliably predicts PCWP in patients with severe LV dysfunction irrespective of degree of MR.

NASA Discipline Cardiopulmonary↗

Measurement of viscosity of gaseous mixtures at atmospheric pressure

Coefficients of viscosity of various types of gas mixtures, including simulated natural-gas samples, have been measured at atmospheric pressure and room temperature using a modified capillary tube method. Pressure drops across the straight capillary tube section of a thermal mass flowmeter were measured for small, well-defined, volume flow rates for the test gases and for standard air. In this configuration, the flowmeter provides the volumetric flow rates as well as a well-characterized capillary section for differential pressure measurements across it. The coefficients of viscosity of the test gases were calculated using the reported value of 185.6 micro P for the viscosity of air. The coefficients of viscosity for the test mixtures were also calculated using Wilke's approximation of the Chapman-Enskog (C-E) theory. The experimental and calculated values for binary mixtures are in agreement within the reported accuracy of Wilke's approximation of the C-E theory. However, the agreement for multicomponent mixtures is less satisfactory, possible because of the limitations of Wilkes's approximation of the classical dilute-gas state model.

Singh, J. J.↗

Passive Water Assurance Delivery System

This report provides an analysis and evaluation of proposed design improvements to the internal water delivery system of NASA’s passive vegetable growing system. The VEGGIE system is designed to provide fresh vegetables and psychological benefits for astronauts aboard the International Space Station. Preliminary testing conducted by NASA for the VEGGIE system revealed flaws in the water delivery system. In these tests, the interface between the plants and the water reservoir failed to provide passive water delivery through the system both in microgravity experiments and experiments conducted on Earth. Our team’s goal was to fix this interface such that water can be passively delivered from the water reservoir to the plant rooting pillows to grow vegetative crops from seed to harvest. The system requirements outlined by NASA include: minimal total mass, on-demand passive water delivery, same dimensions as existing fixtures, minimal pressure on system to prevent leaking, zero mold growth, minimal swelling or clogging for non-flammable capillary materials, pressure stabilization between the water reservoir and plant pillow bags, even dispersal of water during initial priming, minimal bubble obstruction of capillary interface, maximum gas availability to plant roots, growth in a mixed artificial media (50:50 Arcillite:Fafard #2), and to avoid overwatering and drought conditions for plants. The major proposed design improvements are to use a single-interface capillary cord design to directly connect the water reservoir to the plant-rooting pillows, and to alter the water reservoir to model a propellant management device (PMD) in order to ensure consistent and long term watering for the VEGGIE system. The plant rooting pillow required minimal changes outside of replacing the capillary mat on the bottom of the pillow with O-ring insertion points the single-interface capillary system. - Research was conducted to determine which materials are able to uptake water through capillary action to grow Outredgeous Lettuce plants from seed to harvest. The primary requirements to be met by the team's design and evaluation of the capillary interface were: continuous passive watering for 90 days using non-flammable capillary materials and a peak water delivery rate of 30 mL/hr./0.15 m 2 . The results of the team's experimentation showed that the capillary material Nomex displayed the highest capillary water delivery potential with a maximum flow rate of 3.6 mL/hr. The Nomex capillary systems were the only capillary material to consistently grow Outredgeous Lettuce plants from seed to harvest, and displayed the highest average flow rate for multiple experiment sets. The Nomex material was previously incorporated into the VEGGIE system using a matted version of the capillary material, though the team recommends using a cord configuration in the single-interface capillary system for greater system stability. Nomex has proven to be a promising material, as it has passed both health and fire standards for use aboard the International Space Station. PMDs are made of materials that utilize surface tension and adhesive forces to overcome adverse accelerations to improve stability and ensure fluid delivery. PMDs are typically used in fuel tanks to ensure fuel delivery. The team recommends using a sponge PMD in order to mitigate bubble obstruction, decrease system weight, and ensure reliable water delivery to the capillary interface. The PMD water reservoir requires a rigid water reservoir and a vent tube for pressure stabilization. Since PMD’s cannot be tested in 1-G (Earth conditions), further theoretical modeling and testing is required for the proposed water reservoir design. The intent of this proposed system is to passively water plants in microgravity, though the technology is not limited to microgravity applications. The testing at The Ohio State University has proven that the design is highly effective on Earth, demonstrating that it could serve as a simple water delivery system in home and office applications. This would make vegetative crops more accessible in all indoor applications, thereby improving indoor air quality and occupant comfort. Additionally, this technology has great potential to be utilized in greenhouse plant production, cutting back on more sophisticated watering system energy and time requirements.

Alexandria Jensen↗

Short-term reversibility of ultrastructural changes in pulmonary capillaries caused by stress failure

We previously showed that when the pulmonary capillaries in anesthetized rabbits are exposed to a transmural pressure (Ptm) of approximately 40 mmHg, stress failure of the walls occurs with disruption of the capillary endothelium, alveolar epithelium, or sometimes all layers. The present study was designed to determine whether some of the ultrastructural changes are rapidly reversible when the capillary pressure is reduced. To test this, the Ptm was raised to 52.5 cmH2O for 1 min of blood perfusion and then reduced to 12.5 cmH2O for 3 min of saline-dextran perfusion, followed by intravascular fixation at the same pressure. In another group of animals, the pressure was elevated for 1 min of blood and 3 min of saline-dextran before being reduced. The results were compared with previous studies in which the capillary pressures were maintained elevated at 52.5 cmH2O during the entire procedure. Control studies were also done at sustained low pressures. The results showed that the number of endothelial and epithelial breaks per millimeter and the total fraction area of the breaks were reduced when the pressure was lowered. For example, the number of endothelial breaks per millimeter decreased from 7.1 +/- 2.1 to 2.4 +/- 0.7, and the number of epithelial breaks per millimeter fell from 11.4 +/- 3.7 to 3.4 +/- 0.7. There was evidence that the breaks that closed were those that were initially small and were associated with an intact basement membrane. The results suggest that cells can move along their underlying matrix by rapid disengagement and reattachment of cell adhesion molecules, causing breaks to open or close within minutes.(ABSTRACT TRUNCATED AT 250 WORDS).

Non-NASA Center↗

Development and characterization of the Capillary DirectINJECT System

The DirectINJECT Project was initiated to create a reliable in-line dosing system for delivering a concentrated silver ion biocide solution into spacecraft potable water. Three dosing systems, including a miniature peristaltic pump, a multi-piston pump, and a differential pressure-driven capillary tube, were quickly prototyped and tested. Although the peristaltic and multi-piston pump systems met the desired flow rate range, the capillary system showed the most promise and was chosen for further development. In FY23, the Capillary DirectINJECT dosing system underwent extensive testing with a nominal injection rate of 1.0 μl/min into varying backpressure conditions. A Primary DirectINJECT System with triplicate testbeds was employed for long-term testing, and auxiliary systems like the Secondary DirectINJECT System and Leak Testbed were developed to characterize specific components and investigate various phenomena related to the dosing system. Parameters such as flow rates, reservoir pressures, and temperature were monitored throughout the testing campaigns.

DirectINJECT↗

Two-Phase Flow in Packed Beds, Filters and Orifices: Summary of Findings of the Packed Bed Reactor Experiment Onboard of the International Space Station

Understanding the hydrodynamics of adiabatic two-phase flows in packed bed reactors enables the optimization of chemical reaction rates and products that crucial in pharmaceuticals and energy production industries. Additionally, this understanding aids in designing more efficient and compact reactors and reducing space and resource requirements. Insights gained from studying and understanding such flows in microgravity contribute to advancements of space technologies and the enhancement of our capabilities for undertaking future long duration safe, and sustainable space exploration missions. The objective of the Packed Bed Reactor Experiment series (PBRE and PBRE-2) was to develop a fundamental understanding of the hydrodynamics of adiabatic two-phase flows through porous media in microgravity. This work provides a description of the PBRE fluid system and presents the highlights of the PBRE and PBRE-2 previously flown with different packings and operated onboard of the International Space Station Microgravity Science Glovebox (ISS-MSG). These highlights include flow patterns and two-phase pressure drop, and the impact of capillary effects on pressure drop at various gas and liquid flow rates. This work also presents preliminary results from the Packed Bed Reactor Experiment-Water Recovery Series (PBRE-WRS) recently flown with filters and orifices, which was also operated on the ISS-MSG. The objective of the experiment is to validate hydrodynamic models at a range of gas and liquid flow rates pertinent to the operation of these test articles. The microgravity environment allows for measurement and observation of aspects of fluid dynamics that are unique when compared to observations made in full or partial gravity environments.

ISS↗

Mechanism of Headward Fluid Shift During Exposure To Microgravity

A prominent feature of early cardiovascular adaptation to the microgravity of space flight is a shift of blood and tissue fluid from the lower body to the upper body. Symptoms of this fluid shift include facial edema, nasal congestion, and headache. Normally on Earth, the human body is exposed to hydrostatic (gravitational) blood pressure gradients during upright posture. In this posture, mean arterial pressures at head, heart, and foot levels are approximately 70, 100, and 200 mm Hg, respectively. Theoretically, all hydrostatic pressures within arteries and veins are lost during exposure to microgravity so that mean arterial pressure in all regions of the body is uniform and approximately equal to that at heart level (100 mm Hg). Acute studies of 60 head-down tilt (simulated microgravity on Earth) indicate that facial edema is caused by: 1) elevation of capillary blood pressure from 28 to 34 mm Hg, 2) reduction of blood colloid osmotic pressure 22 to 18 mm Hg, and 3) 50% increase of blood perfusion in tissues of the head. Furthermore, as compared to microvasculature in the feet, microvessels of the head have a low capacity to constrict and diminish local perfusion. Elevation of blood and tissue fluid pressures/flow in the head may also explain the higher headward bone density associated with long-term head-down tilt. These mechanistic studies of head-down tilt, along with a better understanding of the relative stresses involved with upright posture and lower body negative pressure, have facilitated development of physiologic countermeasures to maintain astronaut health during microgravity. Presently no exercise hardware is available to provide a blood pressure gradient from head to feet in space. However, recent studies in our laboratory suggest that treadmill exercise within lower body negative pressure provides equivalent or greater physiologic stress as compared to similar upright exercise on Earth.

Hargens, Alan R.↗