Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “capacitive loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Electrolyzer Performance Loss from Accelerated Stress Tests and Corresponding Changes to Catalyst Layers and Interfaces

Stress tests are developed for proton exchange membrane electrolyzers that utilize low catalyst loading, elevated potential, and frequent cycling with square- and triangle-waves to accelerate anode catalyst layer degradation during intermittent operation. Kinetics drive performance losses (ohmic/transport secondary) and are accompanied by decreasing exchange current density, decreasing cyclic voltammetric capacitance, and increasing polarization resistance. Decreased kinetics are likely due to a combination of iridium (Ir) migration into electrochemically inaccessible locations in the anode or membrane, Ir particle growth (supported by X-ray scattering), changes in the extent of the Ir oxidation state (supported by X-ray absorption spectroscopy), and anode catalyst layer reordering. Decreasing catalyst/transport layer contact and catalyst/membrane interfacial tearing may add contact resistances and account for increasing ohmic losses. Performance losses for low and moderate catalyst loading, as well as from accelerated and model wind/solar cycling protocols, were likewise dominated by kinetics but vary in severity. Additionally, accelerated cycling (1 cycle per minute) appears to reasonably accelerate relevant loss mechanisms and can be used to project electrolyzer lifetime from anode deterioration. Ongoing accelerated stress test development and studies into performance loss mechanisms will continue to be critical as electrolysis shifts to intermittent power and low-cost applications.

30 DIRECT ENERGY CONVERSION↗

Mechanism-Informed Breakdown: Understanding Degradation by Controlling Voltage-Hold Patterns in Proton Exchange Membrane Water Electrolyzers

Low catalyst loadings pose challenges to performance stability in proton exchange membrane (PEM) water electrolysis over extended operation. To study the impact of degradation mechanisms and voltage loss rates, different stress tests are applied to membrane electrode assemblies. Potential cycling conditions were observed to induce higher degrees of iridium (Ir) oxide crystallization, ionomer degradation, and catalyst layer (CL) thinning, which likely contributed to higher kinetic loss rates. On the other hand, while Ir migrating into the PEM (Ir band) generally impairs performance, the interconnected and more uniform Ir band formed under a constant 2 V hold may allow for Ir at the catalyst/membrane interface to remain electronically connected and kinetically accessible, as well as indicate greater Ir site access during the applied stressor. The 2 V hold also demonstrates improved kinetic durability through a lower Tafel slope, faster polarization kinetics, and reduced charge transfer resistance. In contrast, potential cycling caused the migration of disconnected Ir agglomerates into the membrane bulk and created a steady increase in charge transfer resistance, a more dramatic decrease in capacitance (46.7% loss), and significant damage to the surrounding ionomer, indicating a decline in both the quality and quantity of active sites in the anode CL. This work underscores the distinct degradation pathways associated with load holds versus cycling, highlighting the role of catalyst-ionomer interactions in kinetic performance and long-term stability. These insights can inform operational strategies for PEM electrolyzers powered by intermittent energy sources, aiming to minimize efficiency losses over extended operation.

36 MATERIALS SCIENCE↗

10 kV Class 14 MHz Isolated Power Supply

This paper presents a single-switch based isolated power supply, utilizing a PCB based core-less transformer to achieve high inter-winding isolation and low common-mode capacitance. Detailed design procedure, considering the transformer to achieve full range ZVS, minimize voltage stress and minimize RMS currents is presented. The proposed methodology is experimentally validated at 14 MHz, with a load variation of 10:1 in output power and a maximum output power of 4 W. The proposed power supply is useful in applications such as MV gate drives and sensors.

Tessaro Andrade, Elvey [ORNL] (ORCID:0009000225919↗

DECENTRALIZED APPROACH TO MULTI-ZONE GREY-BOX MODELING FOR MODEL-BASED PREDICTIVE CONTROL

This study aims to improve the easiness of utilizing the grey-box model (i.e., Resistance-Capacitance circuit) for Model-based Predictive Control (MPC). The primary barrier of implementing the MPC is estimating the control-oriented building model that needs to be computationally inexpensive and quick but reasonably precise in predicting building load and indoor conditions. The estimating of the model parameters becomes more complicated when the building scale is larger; e.g., multi-zone building. In this study, a decentralized approach is introduced; each zone is split and individually estimated with measured boundary temperature from adjacent zones integrated into one single system model. The proposed decentralized method is demonstrated with experimental data from a full-scale multi-zone test cell compared with the centralized reference case.

Joe, Jaewan↗

More Powerful Twistron Carbon Nanotube Yarn Mechanical Energy Harvesters

We report that stretching a coiled carbon nanotube (CNT) yarn can provide large, reversible electrochemical capacitance changes, which convert mechanical energy to electricity. Here, it is shown that the performance of these “twistron” harvesters can be increased by optimizing the alignment of precursor CNT forests, plastically stretching the precursor twisted yarn, applying much higher tensile loads during precoiling twist than for coiling, using electrothermal pulse annealing under tension, and incorporating reduced graphene oxide nanoplates. The peak output power for a 1 and a 30 Hz sinusoidal deformation are 0.73 and 3.19 kW kg -1 , respectively, which are 24- and 13-fold that of previous twistron harvesters at these respective frequencies. This performance at 30 Hz is over 12-fold that of other prior-art mechanical energy harvesters for frequencies between 0.1 and 600 Hz. The maximum energy conversion efficiency is 7.2-fold that for previous twistrons. Twistron anode and cathode yarn arrays are stretched 180° out-of-phase by locating them in the negative and positive compressibility directions of hinged wine-rack frames, thereby doubling the output voltage and reducing the input mechanical energy.

36 MATERIALS SCIENCE↗

Removal and recovery of ammonia from simulated wastewater using Ti3C2Tx MXene in flow electrode capacitive deionization

Abstract Flowing electrode capacitive deionization systems (FE-CDI) have recently garnered attention because of their ability to prevent cross contamination and operate in uninterrupted cycles ad infinitum. Typically, FE-CDI electrodes suffer from low conductivity, reducing deionization performance. Utilization of higher mass loadings to combat this leads to poor rheological properties. Herein, Ti 3 C 2 T x MXene was introduced as 1 mg mL −1 slurry electrodes in an FE-CDI system for the removal and recovery of ammonia from simulated agricultural wastewater. The electrode performance was evaluated by operating the FE-CDI system with a feed solution of 500 mg L −1 NH 4 Cl running in batch mode at a constant voltage of 1.20 and −1.20 V in charging and discharging modes, respectively. Despite the low loading, Ti 3 C 2 T x flowing electrodes showed markedly improved performance, achieving 60% ion removal efficiency in a saturation time of 115 min with an adsorption capacity of 460 mg g −1 . To understand the high adsorption performance of the electrodes, physiochemical and structural analysis was done via a variety of characterization techniques such as SEM, TEM, XRD, DLS, and Raman spectroscopy. Cyclic voltammetry and galvanostatic charge/discharge profiles were obtained to evaluate the electrochemical properties of the electrodes. The system proved to be an energy-saving technology by exhibiting a charge efficiency of 58–70% while operating at an energy consumption of 0.45 kWh kg −1 . A 92% regeneration efficiency showed that the electrodes were stable and suitable for long term and scalable usage. The results demonstrate that MXenes have the potential to improve the FE-CDI process for energy-efficient removal and recovery of ammonia.

36 MATERIALS SCIENCE↗

Interdigitated power connector

An electrical connector carries large amounts of electrical current between two circuit boards with low resistance and low self-inductance by means of an interdigitated anode and cathode, thereby providing low dynamic voltage loss. The connector also may include, near where power will be consumed, an interposer board with on-board capacitance to provide even lower dynamic voltage loss. The connector has application to delivering low-voltage, high-current power from a power supply on a first board to electronics on a second board: the low resistance provides low voltage drop for a load current that is constant, while the low inductance and the capacitors provide low voltage fluctuation for a load current that changes. These issues are of great importance, for example, in designing high-performance computers.

Coteus, Paul W.↗

Selective pseudocapacitive immobilization of REE elements on carbon based electrodes

Current extraction technologies for rare earth elements at ambient conditions are reagent and energy intensive, giving rise to significant quantities of secondary waste streams. Exploration of the removal of common cations from aqueous streams has been undertaken with carbon materials and have shown promising results. However, those promising materials have not been explored extensively for rare earth element capture from aqueous process streams. In this study, a carbon electrode was investigated for the adsorption and immobilization of REE elements from aqueous solutions. Cyclic voltammetry studies of the carbon electrode displayed a pseudocapacitive behavior where it was verified that cation adsorption is accompanied by an electron transfer process. Preliminary tests showed that a current density of 89.1 mA. g -1 , allowed for the pseudocapacitive adsorption (PSA) of Nd 3+ cation without the formation of rare earth hydroxides. Hence, the selective PSA of Nd 3+ was verified in an electrolyte solution with equimolar concentrations of Nd 3+ , Mg 2+ , Li + , Na + and K + , achieving separation factors of 8.6, 1.1, and 10.9 for Nd 3+ /Li + , Nd 3+ /Na + , and Nd 3+ /Mg 2+ , respectively. Analysis of the potential-time curves for the various cations suggests that storage of ions in the electrode involved pore-spacings rather than interlayer spacings and was corroborated by XRD analysis. Specific capacitance as high as >640 F.g -1 for Nd 3+ was also observed for the carbon electrode, with Faradaic efficiencies (FE) of > 20% for Nd 3+ and Mg 2+ , and > 9% for Na + . Furthermore, adsorption capacity of >125 mg g -1 after 4hrs of electrosorption was observed for Nd 3+ . In the presence of the Nd 3+ electrolyte, the electrode achieved increasing storage of Nd 3+ with >94% retention of Nd 3+ with a FE > 20% over 6 cycles between loading and releases in 1 M KCl solution. In conclusion, these preliminary results provide information and some guidance on the selective recovery of rare earth elements, such as Nd, in aqueous streams in the presence of competitive cations employing the use of carbon-based materials.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development and validation of a second-order thermal network model for residential buildings

Heating, Ventilation, and Air Conditioning (HVAC) systems can maintain the space air temperature of residential buildings, either directly by heating/cooling the air, or indirectly via heat transfer to and from the building structure that acts as a thermal mass. Hence, HVAC systems can help achieve load shifting, peak load reduction, and/or energy cost saving, thus enabling grid-interactive HVAC operation. A home thermal model that can accurately reflect the dynamics of the space air and interior wall surface temperatures, is therefore valuable. This paper develops such a model using the standard RC (resistance-capacitance) approach. The model contains a virtual envelope node and an internal space node and is thus second-order. A hybrid parameter identification scheme, made up of the least-squares and optimal search methods, is also developed. The proposed model and scheme were validated using data collected from a test home. It was found that a modest amount of training data was sufficient to yield reliable parameter estimates and accurate prediction. It was also found that when making 24-hour-ahead prediction of the space air temperature, both methods had comparable performances when the training data began in a transition season. However, when they began in an HVAC season, the optimal search method performed better. Furthermore, the least-squares method is recommended during a transition season due to its lower computational burden, while the optimal search method is recommended during an HVAC season due to its better estimation performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Engineering of Self‐Aggregation‐Resistant MnO 2 Heterostructure with A Built‐in Field for Enhanced High‐Mass‐Loading Energy Storage

Abstract Although MnO 2 has been intensively investigated for energy storage, further applications are limited by van der Waals force‐triggered self‐aggregation that always leads to poorly exposed active sites and compromised reaction dynamics, especially under high‐mass‐loading conditions. Herein, by synergistically coupling interfacial modulation with the Kirkendall effect, this work achieves in situ topological structure reorganization of MnOOH toward the high‐aspect‐ratio MnO 2 heterostructure (Heter‐MnO 2 ) with fully exposed active sites, which is ready to assemble into self‐supporting high‐mass‐loading film (30 mg cm −2 ) with restrained self‐aggregation. Theoretical calculation and dynamics analysis results demonstrate the generation of the built‐in field within the heterostructure, thus enhancing the electronic‐transfer and ionic‐adsorption/transport rates. As such, the 30 mg cm −2 Heter‐MnO 2 electrode achieves a superior areal capacitance of 4762 mF cm −2 at 1 mA cm −2 and a sound rate performance (79% at 100 mA cm −2 ) comparable to those of low‐mass‐loading/thin‐film electrodes. As a proof of concept, the fabricated planar interdigital quasi‐solid‐state symmetric micro‐supercapacitor (MSC) based on the Heter‐MnO 2 electrode can deliver a remarkable areal capacitance of 181 mF cm −2 and a considerable volumetric energy density of 10.3 mWh cm −3 . This methodology highlights the promise of surface/interface chemistry modulation for the configuration of easy‐to‐integrate hierarchical nanostructures to better meet practical energy applications.

Chemistry↗

Dynamic Capacitive Wireless Power Transfer System for Electric Vehicles (CRADA Final Report)

Road transportation accounts for 23% of our nation's total energy consumption, 59% of our petroleum consumption and 22% of our total emissions. Electric vehicles (EVs) have much higher well-to-wheel efficiency compared to gasoline vehicles and can reduce our dependence on oil, minimize emissions, improve local air quality and provide a platform for technological innovation and economic growth. While major progress has been made in the development of electric vehicles, their penetration remains under 1 The main hurdles in their widespread adoption are high cost, limited range and long charging times, due to limitations in battery technology. An approach to overcome these hurdles is to substantially reduce the on-board energy storage and instead deliver power wirelessly to the vehicle while it is in motion dynamic wireless power transfer (WPT). For EV charging applications, researchers have traditionally focused on inductive WPT. An issue with inductive WPT systems is that for magnetic flux guidance and shielding, they require ferrite cores, making them expensive, bulky and difficult to embed in the roadway. Under an ARPA-E IDEAS grant, the CU Boulder team has recently developed an alternative approach to WPT based on capacitive coupling that is much smaller, lighter, less expensive, and easier to embed in the roadway than inductive WPT; and have demonstrated a 1.2-kW 6.78-MHz version of this capacitive WPT system on a stationary platform. Under this seed grant program, preliminary work will be carried out on a dynamic capacitive WPT system to prepare a strong proposal for the ARPA-E OPEN 2018 FOA.

33 ADVANCED PROPULSION SYSTEMS↗

An analysis of the hybrid internal mass modeling approach in EnergyPlus

Accurate simulation of building system dynamics is particularly important for understanding building energy flexibility. Among all dynamics in a building, a zone temperature’s variation is especially important, as it significantly affects a building’s electricity load profile when its heating, ventilating, and air conditioning (HVAC) system is controlled with on/off cycles or setpoint reset strategies. To accurately simulate a zone temperature’s dynamics, internal mass needs to be modeled carefully. In this paper, we compare the two internal mass modeling approaches provided by EnergyPlus, i.e., internal mass object and zone air capacitance multiplier, to better understand their impacts on zone temperature simulation. Real building zone temperature dynamic data from small- and medium-sized office buildings are analyzed and compared with simulated data. In particular, we illustrate the effectiveness of a hybrid method of the two EnergyPlus modeling approaches, which yields more realistic zone temperature dynamics, especially when the zone is conditioned with heat pump systems with on/off cycling.

Chen, Zhelun↗

Non-contact Current-Voltage (I-V) Tracer for Photovoltaics

This report presents a non-contact approach to simultaneously obtain current-voltage (I-V) curves of photovoltaic (PV) substrings and modules in a string without the need of disconnecting the individual modules from the string. There are two types of I-V curve tracers currently available in the marketplace, capacitor-based and electronic load-based. The primary requirement of these conventional I-V tracers is the disconnection of individual modules in the string so the individual modules contacted through the connectors of the individual modules. These contact-tracers have three major limitations in the utility scale power plants: First limitation – Weather and Accuracy: The mass-produced commercial contact-tracers cannot obtain the I-V curves of both string and its modules (as high as 30 modules), almost simultaneously (within about 5 minutes) at, practically, a single irradiance level, a single module temperature, a single spectrum and a single AOI (angle of incidence). This inability of the contact-tracers forces the testing personnel to wait for an extended or multiple sunny (>800 W/m 2 ) duration(s) of a cloudy day. This is a serious limitation as waiting for the sunny conditions or days is a huge practical challenge in almost all locations, except desert locations. Also, since the I-V curves are obtained at different prevailing weather conditions, it becomes critical to translate all the measured I-V curves of 30 modules in the string to a single test condition, for example STC (standard test conditions), so the underperforming modules can be identified. The accuracy of translation equations is heavily influenced by the irradiance level and temperature, spectral and AOI ranges; Second limitation - Safety: The second limitation is related to the high voltage electrical safety of the test personnel during disconnecting and reconnecting of individual modules or cable connectors from the string under daylight conditions and damaging of the original module connectors (especially the field aged connectors) during the disconnecting and reconnecting process; Third limitation – Labor: The third limitation is related to the enormous amount of time and hardship for the test personnel under prevailing (often harsh) protracted field conditions. This project was executed by Arizona State University in collaboration with its industry partner, PV Measurements Inc. (PVM). To mitigate all the three challenges of the state-of-the-art equipment indicated above, we utilized a non-contact I-V (NCIV) tracer approach. In this approach, we utilized an electrostatic voltmeter (ESV) and voltage sensor/probe combination to obtain I-V curves. The ESV units are extensively used in the high voltage industry but not in the PV industry. To obtain the simultaneous I-V curves of the substrings and modules within a string, we utilized multiple commercial ESV-Probe sets. In this approach, we utilized a non-contact voltage sensor (called, Probe) placed on the glass surface of the module (above the last cell of the module). This probe senses the module voltage (with respect to ground) through measured capacitance which is dictated by the surface charges (which in turn is dictated by the module voltage) and transmits the sensed voltage to the voltmeter (called, ESV or NCV, non-contact voltmeter). The current is sensed by a non-contact hall sensor. In a 30-module string, the 30th probe obtains the entire string I-V along with the string I-V obtained by the electronic load. so that the I-V curves of the substrings and modules can be obtained by NCIV without the need of disconnecting the individual modules in the string. The string I-V curves obtained by the electronic load and NCIV can be compared for the accuracy determination. One can use 30 ESV units and 30 Probes to obtain 30 I-V curves of a 30-module string or use just 5 ESV units and 30 Probes in conjunction with 5 six-channel switchboxes (called, 6:1 switchboxes). To reduce the equipment cost, we utilized the 6:1 switchbox approach so the number of ESV units is reduced from 30 to 5. The approaches, achievements and challenges of this project are detailed in this report.

14 SOLAR ENERGY↗

Upcycling Linear Low-Density Polyethylene Waste into Graphene for High Mass Loading Supercapacitors

Upcycling plastic into advanced carbons, such as graphene and porous carbon, offers attractive options to manage waste streams by converting the plastic into carbon electrode materials for energy storage devices. Linear low density polyethylene (LLDPE) is firstly bulk-oxidized with a facile and scalable method and then carbonized and catalyticlly graphenized into porous graphene materials. The LLDPE derived graphene (LLDPE-G) has a BET specific surface area up to 1800 m2/g and Raman ID/IG ratio of 0.85. When used as electrode material for symmetric supercapacitor, LLDPE-G possesses outstanding specific capacitance and excellent areal capacitance. Moreover, LLDPE-G exhibits exceptional cycling stability with capacitance retention of 95.8% after 100,000 cycles. Last but not least, KCl is recycled and reused over 3 cycles with material quality and electrocapacitive performance of LLDPE-G retained and verified after each cycle.

Gao, Yuan↗

Resistively loaded coplanar waveguide for microwave measurements of induced carriers

We describe the use of a coplanar waveguide (CPW) whose slots are filled with a resistive film, a resistively loaded CPW (RLCPW), to measure two-dimensional electron systems (2DESs). The RLCPW applied to the sample hosting the 2DES provides a uniform metallic surface serving as a gate to control the areal charge density of the 2DES. As a demonstration of this technique, we present measurements on a Si metal–oxide–semiconductor field-effect transistor and a model that successfully converts microwave transmission coefficients into conductivity of a nearby 2DES capacitively coupled to the RLCPW. We also describe the process of fabricating the highly resistive metal film required for fabrication of the RLCPW.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Improved Fireset Acceptance Using Established Evaluation Measurements

As new insight is gained into the relationship between firesets and detonators, tighter control of the circuit parameters is desired to maintain consistent and optimum system performance. An analysis of the established acceptance method reveals that it has insufficient precision to guarantee a uniform population of units. While the production has been historically very uniform, the uniformity has been primarily due to the quality and consistency of the manufacturing process rather than to the stringency of the acceptance criteria. The established method of evaluating and accepting firesets for the stockpile has been to discharge the units into a representative load and to record the output current waveform. Three characteristics of the output waveform (Peak Current, Rise Time, and Pulse Width) are then analyzed and an acceptance window is applied directly to these measurements. The purpose of this paper is to introduce a new approach that incorporates these same established measurements. However, instead of applying acceptance criteria to the three measurements directly, rather these measurements are used to evaluate the circuit values of capacitance, inductance and resistance to provide a more stringent and uniform acceptance criteria.

42 ENGINEERING↗

Power matching to pulsed inductively coupled plasmas

Matching of power delivery to nonlinear loads in plasma processing is a continuing challenge. Plasma reactors used in microelectronics fabrication are increasingly multi-frequency and/or pulsed, producing a non-linear and, in many cases, non-steady state electrical termination that can complicate efficient power coupling to the plasma. This is particularly the case for pulsed inductively coupled plasmas where the impedance of the plasma can significantly change during the start-up-transient and undergo an E–H (capacitive-to-inductive) transition. In this paper, we discuss the results from a computational investigation of the dynamics of power matching to pulsed inductively coupled plasmas (Ar/Cl 2 mixtures of tens of mTorr pressure) using fixed component impedance matching networks and their consequences on plasma properties. In this investigation, we used set-point matching where the components of the matching network provide a best-case impedance match (relative to the characteristic impedance of the power supply) at a chosen time during the pulsed cycle. Matching impedance early during the pulse enables power to feed the E-mode, thereby emphasizing capacitive coupling and large excursions in the plasma potential. This early power coupling enables a more rapid ramp-up in plasma density while being mismatched during the H-mode later in the pulse. The early match also produces more energetic ion bombardment of surfaces. Matching late in the pulse diminishes power dissipated in the E-mode at the cost of also reducing the rate of increase in plasma density.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗