Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “camera design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Design and engineering challenges of a multi-energy hard x-ray camera for long-pulse profile measurements at WEST tokamak

The WEST tokamak has recently been prepared for long pulse operation with a water-cooled full first wall. Heating is provided by radiofrequency systems, including Lower Hybrid Current Drive (LHCD). The Princeton Plasma Physics Laboratory has developed a multi-energy hard x-ray camera for profile measurements at WEST. The camera is based on a new generation of 2D pixel array detectors that allow the energy threshold to be independently set for each pixel. The diagnostic will provide spatial, temporal and energy resolved measurements of the hard x-ray emission from the full plasma cross-section, investigating several physical quantities such as the electron temperature from continuum emission, the fast electron tail density produced by radiofrequency current drive and runaway electrons, as well as characteristic tungsten x-rays due to beam-target emission at the edge. Overall, this work describes the engineering challenges that the WEST long pulse scenario poses for this diagnostic and how the design addresses and solves them. Vacuum, thermal stress and heat transfer calculations are presented and discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Machine Learning Enabled Sensor Fusion for In-Situ Defect Detection in Laser Powder Bed Fusion

Laser Powder Bed Fusion (L-PBF) Additive Manufacturing (AM) is among the metal 3D printing technologies most broadly adopted by the manufacturing industry. The current industry qualification paradigm for critical-application L-PBF parts relies heavily on expensive non-destructive inspection techniques such as X-Ray Computed Tomography (XCT), which significantly limits the use-cases of L-PBF. In situ monitoring of the process promises a less expensive alternative to ex situ testing, but existing sensor technologies and data analysis techniques struggle to detect sub-surface flaws (e.g., porosity and cracking) on production-scale L-PBF printers. RTX Technologies Research Center (RTRC) has licensed ORNL’s Peregrine software package – a printer- and camera-agnostic data analytics tool designed specifically for detecting process anomalies using in situ data collected during powder bed printing. The goal of this project was to feed temporally rich, multi-modal sensor data, including visible light, integrated near infrared (NIR), and spatially mapped co-axial melt pool thermal emission data into Peregrine to enable detection of subsurface flaws. XCT data was used as ground truth training data to allow Peregrine’s deep learning algorithms to recognize anomalies in these complex data streams in both test artifacts and industrially relevant geometries. Completion of this program has seen the successful implementation of multi-modal, multi-layer sensor data footprints for training of machine learning models in Peregrine. Flaws detected in XCT data have been successfully detected directly from this in situ data footprint, and initial analyses of the in situ probability-of-detection has been conducted, showing performance levels commensurate with traditional non-destructive evaluation (NDE) methods. The in situ monitoring methodology was then applied to an industrially relevant component that was using post-build NDE, highlighting the utility of the proposed method for hard-to-inspect AM components. As a direct result of this program, two journal manuscripts [1], [2] have been published in Additive Manufacturing, with additional manuscripts planned following program completion.

36 MATERIALS SCIENCE↗

Optical Relays for Imaging Scintillators

Cygnus is a dual beam high-energy radiographic x-ray source. Ten years ago, three large zoom lenses were assembled to collect images from 200 mm x 200 mm square scintillators. The zoom capability allows zooming down to a 60 mm x 60 mm picture from the scintillator. Current radiographic imaging needs now require larger 270 mm x 270 mm square scintillators and the capability to use both 92 mm x 92 mm and 62 mm x 62 mm CCD cameras, and a new lens design to meet these needs. This zoom lens incorporates 11 elements and is designed to be telecentric. It images a scintillator emitting light peaking at 435 nm, so special glass types are required for the lens elements. Much larger elliptical pellicles are needed to deflect the scintillator light out of the x-ray path into the lens. The optical axis of the imaging system must be colinear with the x-ray axis. Two scintillators are positioned in each of two Cygnus x-ray axes, for a total of four scintillators and four lens systems. An optional configuration will be shown, enabling two lens systems imaging opposite sides of a single scintillator, for a total of four lenses and two scintillators. Although this configuration has advantages, it suffers from crosstalk. Care must be taken to analyze the anti-reflection coatings applied to all the elements in the imaging chain, including the CCD array and

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electrical design of the flexible imaging diffraction diagnostic for laser experiments (FIDDLE) at the National Ignition Facility (NIF)—Requirements, design, and performance

The Flexible Imaging Diffraction Diagnostic for Laser Experiments (FIDDLE) is a newly developed diagnostic for imaging time resolved diffraction in experiments at the National Ignition Facility (NIF). It builds on the successes of its predecessor, the Gated Diffraction Development Diagnostic (G3D). The FIDDLE was designed to support eight Daedalus version 2 sensors (six more hCMOS sensors than any other hCMOS-based diagnostic in NIF to date) and an integrated streak camera. We will review the electrical requirements, design, and performance of the electrical subsystems that were created to support this large number of cameras in the FIDDLE. The analysis of the data that the FIDDLE is intended to collect relies heavily on the accurate and well-understood timing of each sensor. We report camera-to-camera timing jitter of less than 100 ps rms and sensor integration times of 2.2 ns FWHM in 2-2 timing mode. Additionally, diffraction experiments on the NIF produce electric fields (EMI) on the order of 1 kV/m, which have been observed to negatively impact the performance of some electrical components of the FIDDLE. We report on the results of testing hCMOS camera electronics in a similar EMI environment generated in an offline lab. In addition, we also summarize the use of a novel approach to using a vector network analyzer as an EMI leak detector to understand and reduce the negative impacts of EMI on the FIDDLE.

47 OTHER INSTRUMENTATION↗

Design of a neutron microscope based on Wolter mirrors

The predominant geometry for a neutron imaging experiment is that of a pinhole camera. Here, this is primarily due to the difficulty in focusing neutrons due to the weak refractive index, which is also strongly chromatic. Proof of concept experiments demonstrated that neutron image forming lenses based on reflective Wolter mirrors can produce quantitative, high spatial resolution neutron images while also increasing the time resolution compared to the conventional pinhole camera geometry. Motivated by these results, we report the design of a neutron microscope where two Wolter mirrors replace condensing and objective lenses, in direct analogy with typical visible light microscopes. Ray tracing results indicate that this system will yield 3 µm spatial resolution images with an acquisition time of order <1 s (10 4 faster than currently possible at this spatial resolution) with a field of view of about 5 mm in diameter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Summertime Continental Shallow Cumulus Cloud Detection Using GOES-16 Satellite and Ground-Based Stereo Cameras at the DOE ARM Southern Great Plains Site

Summertime continental shallow cumulus clouds (ShCu) are detected using Geostationary Operational Environmental Satellite (GOES)-16 reflectance data, with cross-validation by observations from ground-based stereo cameras at the Department of Energy Atmospheric Radiation Measurement Southern Great Plains site. A ShCu cloudy pixel is identified when the GOES reflectance exceeds the clear-sky surface reflectance by a reflectance detection threshold of ShCu, ΔR. We firstly construct diurnally varying clear-sky surface reflectance maps and then estimate the ΔR. A GOES simulator is designed, projecting the clouds reconstructed by stereo cameras towards the surface along the satellite’s slanted viewing direction. The dynamic ShCu detection threshold ΔR is determined by making the GOES cloud fraction (CF) equal to the CF from the GOES simulator. Although there are temporal variabilities in ΔR, cloud fractions and cloud size distributions can be well reproduced using a constant ΔR value of 0.045. The method presented in this study enables daytime ShCu detection, which is usually falsely reported as clear sky in the GOES-16 cloud mask data product. Using this method, a new ShCu dataset can be generated to bridge the observational gap in detecting ShCu, which may transition into deep precipitating clouds, and to facilitate further studies on ShCu development over heterogenous land surface.

54 ENVIRONMENTAL SCIENCES↗

Large Game Distribution Camera Study at Los Alamos National Laboratory [Poster]

The unique habitats at the Laboratory support a diverse community of wildlife. The habitat types that include Pinon Juniper, Ponderosa Pine, and Mixed-conifer forests each provide different resources important for a variety of species. Wildlife monitoring for large game animals can be challenging because they avoid interactions with humans, and prefer undeveloped areas. This study was conducted to analyze the distribution of predators and other game animals seasonally across the Laboratory. The data gathered will be used to make recommendations regarding wildlife management for conservation and protection. Utilizing game cameras to remotely monitor wildlife was determined to be the most effective, noninvasive method to gather the necessary data. As camera technology has advanced, game cameras have become adequate for documenting individuals, and are commonly used in wildlife studies on predation, abundance, occupancy, diversity, and endangered species detection. Twenty cameras were placed across the LANL landscape using a modified systematic sampling design. They were deployed in February 2018 and retrieved in January 2019, thus each camera sampled for one full year. All images were reviewed and the species, number, age, and sex of all animals in the photo were recorded. Here we present data for the most abundant species encountered: deer, elk, coyote, bear, bobcat, mountain lion, and fox respectively. The data were summarized by species and season. Future work will include occupancy modelling for each species. This will allow the development of heat maps showing species distributions across the Laboratory.

54 ENVIRONMENTAL SCIENCES↗

Large Game Distribution Camera Study at Los Alamos National Laboratory

The unique habitats at the Laboratory support a diverse community of wildlife. The habitat types that include Pinon Juniper, Ponderosa Pine, and Mixed-conifer forests each provide different resources important for a variety of species. Wildlife monitoring for large game animals can be challenging because they avoid interactions with humans, and prefer undeveloped areas. This study was conducted to analyze the distribution of predators and other game animals seasonally across the Laboratory. This research informs decisions regarding wildlife management recommendations for conservation and protection. This study utilized game cameras to remotely monitor wildlife. As camera technology has advanced, game cameras have become adequate for documenting individuals, and are commonly used in wildlife studies on predation, abundance, occupancy, diversity, and endangered species detection. Twenty cameras were placed across the LANL landscape using a modified systematic sampling design. They were deployed in February 2018 and retrieved in January 2019, thus each camera sampled for one full year. All images were reviewed and the species, number, age, and sex of all animals in the photo were recorded. Here we present data for the most abundant species encountered: deer, elk, coyote, bear, bobcat, mountain lion, and fox respectively. The data were summarized by species and season. Future work will include occupancy modelling for each species. This will allow the development of heat maps showing species distributions across the Laboratory.

59 BASIC BIOLOGICAL SCIENCES↗

SPT-3G+: mapping the high-frequency cosmic microwave background using kinetic inductance detectors

We present the design and science goals of SPT-3G+, a new camera for the South Pole Telescope, which will consist of a dense array of 34100 kinetic inductance detectors measuring the cosmic microwave background (CMB) at 220, 285 and 345 GHz. The SPT-3G+ dataset will enable new constraints on the process of reionization, including measurements of the patchy kinematic Sunyaev-Zeldovich effect and improved constraints on the optical depth due to reionization. At the same time, it will serve as a pathfinder for the detection of Rayleigh scattering, which could allow future CMB surveys to constrain cosmological parameters better than from the primary CMB alone. In addition, the combined, multi-band SPT-3G and SPT-3G+ survey data, will have several synergies that enhance the original SPT-3G survey, including: extending the redshift-reach of SZ cluster surveys to z > 2; understanding the relationship between magnetic fields and star formation in our Galaxy; improved characterization of the impact of dust on inflationary B-mode searches; and characterizing astrophysical transients at the boundary between mm and sub-mm wavelengths. Finally, the modular design of the SPT-3G+ camera allows it to serve as an on-sky demonstrator for new detector technologies employing microwave readout, such as the on-chip spectrometers that we expect to deploy during the SPT-3G+ survey. In this paper, we describe the science goals of the project and the key technology developments that enable its powerful yet compact design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and commissioning of resistive foil bolometer diagnostics on the ST40 tokamak

Following successful campaigns on the compact high field spherical tokamak ST40, resistive gold foil bolometers have now been installed to measure the radiated power profile. Positioned on the midplane, two bolometer cameras offer perspectives of the horizontal and vertical planes, while the third camera, situated above the midplane, provides a vertical view of the top divertor plates, including the X-point and the strike points. Further, these cameras use a commercial off-the-shelf data acquisition platform with modules specifically designed for bolometers in a Wheatstone bridge configuration, providing both phase sensitive detection and in situ calibration. This paper presents an overview of the design and functionality of all three cameras and the commissioning of the horizontal plane camera. The commissioning of the horizontal camera shows data from a range of plasma pulses, presenting a positive correlation between the relative profiles measured from the bolometer camera and an absolute extreme ultraviolet diode camera viewing along similar lines of sight.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A time-resolved, in-chamber x-ray pinhole imager for Z

We have commissioned a new time-resolved, x-ray imaging diagnostic for the Z facility. The primary intended application is for diagnosing the stagnation behavior of Magnetized Liner Inertial Fusion (MagLIF) and similar targets. We have a variety of imaging systems at Z, both time-integrated and time-resolved, that provide valuable x-ray imaging information, but no system at Z up to this time provides a combined high-resolution imaging with multi-frame time resolution; this new diagnostic, called TRICXI for Time Resolved In-Chamber X-ray Imager, is meant to provide time-resolved spatial imaging with high resolution. The multi-frame camera consists of a microchannel plate camera. A key component to achieving the design goals is to place the instrument inside the Z vacuum chamber within 2 m of the load, which necessitates a considerable amount of x-ray shielding as well as a specially designed, independent vacuum system. Here, a demonstration of the imaging capability for a series of MagLIF shots is presented. Predictions are given for resolution and relative image irradiance to guide experimenters in choosing the desired configuration for their experiments.

47 OTHER INSTRUMENTATION↗

Developing time-resolved x-ray diffraction diagnostics at the National Ignition Facility (invited)

As part of a program to measure phase transition timescales in materials under dynamic compression, we have designed new x-ray imaging diagnostics to record multiple x-ray diffraction measurements during a single laser-driven experiment. Our design places several ns-gated hybrid CMOS (hCMOS) sensors within a few cm of a laser-driven target. The sensors must be protected from an extremely harsh environment, including debris, electromagnetic pulses, and unconverted laser light. Another key challenge is reducing the x-ray background relative to the faint diffraction signal. Building on the success of our predecessor (Target Diffraction In Situ), we implemented a staged approach to platform development. First, we built a demonstration diagnostic (Gated Diffraction Development Diagnostic) with two hCMOS sensors to confirm we could adequately protect them from the harsh environment and also acquire acceptable diffraction data. This allowed the team to quickly assess the risks and address the most significant challenges. Here, we also collected scientifically useful data during development. Leveraging what we learned, we recently developed a much more ambitious instrument (Flexible Imaging Diffraction Diagnostic for Laser Experiments) that can field up to eight hCMOS sensors in a flexible geometry and participate in back-to-back shots at the National Ignition Facility (NIF). The design also allows for future iterations, such as faster hCMOS sensors and an embedded x-ray streak camera. The enhanced capabilities of the new instrument required a much more complex design, and the unexpected issues encountered on the first few shots at NIF remind us that complexity has consequences. Our progress in addressing these challenges is described herein, as is our current focus on improving data quality by reducing x-ray background and quantifying the uncertainties of our diffraction measurements.

36 MATERIALS SCIENCE↗

Laboratory Measurements of Instrumental Signatures of the LSST Camera Focal Plane

Electro-optical testing and characterization of the Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST) Camera focal plane, consisting of 205 charge-coupled devices (CCDs) arranged into 21 stand-alone Raft Tower Modules (RTMs) and 4 Corner Raft Tower Modules (CRTMs), is currently being performed at the SLAC National Accelerator Laboratory. Testing of the camera sensors is performed using a set of custom-built optical projectors, designed to illuminate the full focal plane or specific regions of the focal plane with a series of light illumination patterns: the crosstalk projector, the flat illuminator projector, and the spot grid projector. In addition to measurements of crosstalk, linearity and full well, the ability to project realistically-sized sources, using the spot grid projector, makes possible unique measurements of instrumental signatures such as deferred charge distortions, astrometric shifts due to sensor effects, and the brighter-fatter effect, prior to camera first light. Here we present the optical projector designs and usage, the electro-optical measurements and how these results have been used in testing and improving the LSST Camera instrumental signature removal algorithms.

79 ASTRONOMY AND ASTROPHYSICS↗

The fast camera (Fastcam) imaging diagnostic systems on the DIII-D tokamak

Two camera systems are installed on the DIII-D tokamak at the toroidal positions of 90° (90° system) and 225° (225° system), respectively. The cameras have two types of relay optics, namely, a coherent optical fiber bundle and a periscope system. The periscope system provides absolute intensity calibration stability while sacrificing resolution (10 lp/mm), while the fiber system provides high resolution (16 lp/mm) while sacrificing calibration stability. The periscope is available only for the 90° system. The optics of the 225° system were designed for view stability, repeatability, and easy maintenance. The cameras are located inside optimized neutron, x ray and magnetic shielding in order to reduce electronics damage, reboots, and magnetic and neutron interference, increasing the overall system reliability. An automated filter wheel, providing remote filter change, allows for remote wavelength selection. A software suite automates camera acquisition and data storage, allowing for remote operation and reduced operator involvement. System metadata is used to streamline the data analysis workflow, particularly for intensity calibration. Here, the spatial calibration uses multiple observable wall features, resulting in a reconstruction accuracy ≤2 cm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exploiting universal nonlocal dispersion in optically active materials for spectro-polarimetric computational imaging

Recent years have seen significant advancements in exploring novel light-matter interactions such as hyperbolic dispersion within natural crystals. However, current studies have predominantly concentrated on local optical response of materials characterized by a dielectric tensor without spatial dispersion. Here, we investigate the nonlocal response in optically-active crystals with screw symmetries, revealing their lossless, super-dispersive properties compared to traditional optical response functions. We leverage this universal nonlocal dispersion, i.e. the dispersion of optical rotatory power, to explore a novel spectral de-multiplexing scheme compared to conventional gratings, prisms and metasurfaces. We design and demonstrate an ‘Nonlocal-Cam’ - a camera that exploits nonlocal dispersion through sampling of polarized spectral states and the application of computational spectral reconstruction algorithms. The Nonlocal-Cam captures information in both laboratory and outdoor field experiments which is unavailable to traditional intensity cameras - the spectral texture of polarization. Merging the fields of nonlocal electrodynamics and computational imaging, our work paves the way for exploiting nonlocal optics of optically active materials in a variety of applications, from biological microscopy to physics-driven machine vision and remote sensing.

Wang, Xueji [Purdue Univ., West Lafayette, IN (Uni↗

Chemical and physical transformations of carbon-based nanomaterials observed by liquid phase transmission electron microscopy

This article addresses recent advances in liquid phase transmission electron microscopy (LPTEM) for studying nanoscale synthetic processes of carbon-based materials that are independent of the electron beam—those driven by nonradiolytic chemical or thermal reactions. In particular, we focus on chemical/physical formations and the assembly of nanostructures composed of organic monomers/polymers, peptides/DNA, and biominerals. The synthesis of carbon-based nanomaterials generally only occurs at specific conditions, which cannot be mimicked by aqueous solution radiolysis. Carbon-based structures themselves are also acutely sensitive to the damaging effects of the irradiating beam, which make studying their synthesis using LPTEM a unique challenge that is possible when beam effects can be quantifi ed and mitigated. With new direct sensing, high frame rate cameras, and advances in liquid-cell holder designs, combined with a growing understanding of irradiation effects and proper experimental controls, microscopists have been able to make strides in observing traditionally problematic carbon-based materials under conditions where synthesis can be controlled, and imaged free from beam effects, or with beam effects quantified and accounted for. These materials systems and LPTEM experimental techniques are discussed, focusing on nonradiolytic chemical and physical transformations relevant to materials synthesis.

Parent, Lucas R.↗

SOAR/Goodman Spectroscopic Assessment of Candidate Counterparts of the LIGO/Virgo Event GW190814*

On 2019 August 14 at 21:10:39 UTC, the LIGO/Virgo Collaboration (LVC) detected a possible neutron star–black hole merger (NSBH), the first ever identified. An extensive search for an optical counterpart of this event, designated GW190814, was undertaken using the Dark Energy Camera on the 4 m Victor M. Blanco Telescope at the Cerro Tololo Inter-American Observatory. Target of Opportunity interrupts were issued on eight separate nights to observe 11 candidates using the 4.1 m Southern Astrophysical Research (SOAR) telescope’s Goodman High Throughput Spectrograph in order to assess whether any of these transients was likely to be an optical counterpart of the possible NSBH merger. Here, we describe the process of observing with SOAR, the analysis of our spectra, our spectroscopic typing methodology, and our resultant conclusion that none of the candidates corresponded to the gravitational wave merger event but were all instead other transients. Finally, we describe the lessons learned from this effort. Application of these lessons will be critical for a successful community spectroscopic follow-up program for LVC observing run 4 (O4) and beyond.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of a SiPM-based monolithic neutron scatter camera using dark counts

The Single Volume Scatter Camera (SVSC) Collaboration aims to develop portable neutron imaging systems for a variety of applications in nuclear non-proliferation. Conventional double-scatter neutron imagers are composed of several separate detector volumes organized in at least two planes. A neutron must scatter in two of these detector volumes for its initial trajectory to be reconstructed. As such, these systems typically have a large footprint and poor geometric efficiency. We report on the design and characterization of a prototype monolithic neutron scatter camera that is intended to significantly improve upon the geometrical shortcomings of conventional neutron cameras. The detector consists of a 50 mm×56 mm× 60 mm monolithic block of EJ-204 plastic scintillator instrumented on two faces with arrays of 64 Hamamatsu S13360-6075PE silicon photomultipliers (SiPMs). The electronic crosstalk is limited to < 5% between adjacent channels and < 0.1% between all other channel pairs. SiPMs introduce a significantly elevated dark count rate over PMTs, as well as correlated noise from after-pulsing and optical crosstalk. In this article, we characterize the dark count rate and optical crosstalk and present a modified event reconstruction likelihood function that accounts for them. We find that the average dark count rate per SiPM is 4.3 MHz with a standard deviation of 1.5 MHz among devices. The analysis method we employ to measure internal optical crosstalk also naturally yields the mean and width of the single-electron pulse height. Here, we calculate separate contributions to the width of the single-electron pulse-height from electronic noise and avalanche fluctuations. We demonstrate a timing resolution for a single-photon pulse to be (128 ± 4) ps. Finally, coincidence analysis is employed to measure external (pixel-to-pixel) optical crosstalk. We present a map of the average external crosstalk probability between 2×4 groups of SiPMs, as well as the in-situ timing characteristics extracted from the coincidence analysis. Further work is needed to characterize the performance of the camera at reconstructing single- and double-site interactions, as well as image reconstruction.

47 OTHER INSTRUMENTATION↗