Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Real Time Calibration Method for Signal Conditioning Amplifiers

A signal conditioning amplifier receives an input signal from an input such as a transducer. The signal is amplified and processed through an analog to digital converter and sent to a processor. The processor estimates the input signal provided by the transducer to the amplifier via a multiplexer. The estimated input signal is provided as a calibration voltage to the amplifier immediately following the receipt of the amplified input signal. The calibration voltage is amplified by the amplifier and provided to the processor as an amplified calibration voltage. The amplified calibration voltage is compared to the amplified input signal, and if a significant error exists, the gain and/or offset of the amplifier may be adjusted as necessary.

Pedro J Medelius↗

Comparison of temperature adaptive calibration methods for laser induced fluorescence based fuel-in-oil instrument

Fuel dilution of engine oil (or fuel-in-oil, FiO) is an important issue as multiple and late-cycle fuel injection, integral to many combustion efficiency and emissions improvements (e.g., downsized boosted gasoline engines and catalyst thermal management) increases FiO rate. In addition to causing general wear and corrosion in engine due to decreased oil viscosity and pH buffering, FiO is also believed to cause destructive low speed pre-ignition (or super knock) in boosted SI engines. To understand the effects of engine operating conditions on the FiO rate, an optical diagnostic capable of measuring transient FiO on minute timescales was recently developed and demonstrated on a modified GM Ecotech engine system (Neupane et al., Applied Spectroscopy 2021). The measurement is based on adding a dye to the fuel and monitoring for its presence in oil via laser-induced fluorescence (LIF). The measured LIF signal is related to FiO concentration via pre-determined calibration factors using a multivariate classical least square (CLS) method.Since fluorescence quantum yield is a function of temperature, measured LIF intensity not only depends on FiO concentration but also oil temperature. To expand the applicability of the FiO diagnostic to transient oil-temperature conditions (e.g., cold start in practical engines), this study develops a method to account for oil-temperature variations. The effect of oil temperature (20°C - 95°C) on the LIF spectra of eight FiO samples ranging from ~0.8-15% was investigated. LIF intensities of the FiO samples decreased linearly with increasing temperature; the reductions being more significant at dye peaks. We develop a new calibration model (T-adaptive CLS) incorporating the temperature (T) effects on LIF intensity that enables simultaneous calculation of FiO and oil temperature. The improved FiO diagnostic with T-adaptive calibration is more robust, and applicable to varying oil-temperature conditions. For example, when strategies such as multiple/late fuel injections are applied to overcome cold-start instability due to use of low vaporization bio-based fuels such as ethanol, FiO rate is expected to be very high; the improved T-adaptive FiO diagnostic is hence relevant for engine- and fuel-system calibration and optimization. The diagnostic could also provide validation data for flow-field and spray interaction CFD models, further broadening the diagnostic’s utility for advancing engine technology and efficiency.

Neupane, Sneha↗

ISS Payload Racks Automated Flow Control Calibration Method

Payload Racks utilize MTL and/or LTL station water for cooling of payloads and avionics. Flow control range from valves of fully closed, to up to 300 Ibmhr. Instrument accuracies are as high as f 7.5 Ibm/hr for flow sensors and f 3 Ibm/hr for valve controller, for a total system accuracy of f 10.5 Ibm/hr. Improved methodology was developed, tested and proven that reduces accuracy of the commanded flows to less than f 1 Ibmhr. Uethodology could be packed in a "calibration kit" for on- orbit flow sensor checkout and recalibration, extending the rack operations before return to earth. -

Simmonds, Boris G.↗

A Dynamic Calibration Method for Experimental and Analytical Hub Load Comparison

This paper presents the results from an ongoing effort to produce improved correlation between analytical hub force and moment prediction and those measured during wind-tunnel testing on the Aeroelastic Rotor Experimental System (ARES), a conventional rotor testbed commonly used at the Langley Transonic Dynamics Tunnel (TDT). A frequency-dependent transformation between loads at the rotor hub and outputs of the testbed balance is produced from frequency response functions measured during vibration testing of the system. The resulting transformation is used as a dynamic calibration of the balance to transform hub loads predicted by comprehensive analysis into predicted balance outputs. In addition to detailing the transformation process, this paper also presents a set of wind-tunnel test cases, with comparisons between the measured balance outputs and transformed predictions from the comprehensive analysis code CAMRAD II. The modal response of the testbed is discussed and compared to a detailed finite-element model. Results reveal that the modal response of the testbed exhibits a number of characteristics that make accurate dynamic balance predictions challenging, even with the use of the balance transformation.

Kreshock, Andrew R.↗

Systems for passive microwave remote sensing and their calibration methods

A system for passive microwave remote sensing using at least one microwave radiometer includes a fixed body portion and a mobile body portion. The mobile body portion is configured for rotatably coupling with the fixed body portion for rotation about a rotation axis. The mobile body portion is configured for supporting the microwave radiometer therein such that the microwave radiometer rotates about the rotation axis when the mobile body portion is rotated about the rotation axis such that a polarization axis of the radiometer is aligned with an earth axis. The fixed body portion includes a motor mechanism for effecting rotation of the mobile body portion. In an embodiment, the mobile body portion includes a plurality of body section, each body section being configured for supporting a microwave radiometer therein. In another embodiment, each one of the plurality of body sections is configured to be interchangeably coupled with each other.

47 OTHER INSTRUMENTATION↗

Systems for passive microwave remote sensing and their calibration methods

A system for passive microwave remote sensing using at least one microwave radiometer includes a fixed body portion, the fixed body portion being configured to attach to a mobile platform, and a mobile body portion, the mobile body portion being configured for rotatably coupling with the fixed body portion for rotation about a rotation axis. The mobile body portion is configured for supporting the at least one microwave radiometer therein such that the at least one microwave radiometer rotates about the rotation axis when the mobile body portion is rotated about the rotation axis such that a polarization axis of the at least one radiometer is aligned with an earth axis. The fixed body portion includes a motor mechanism for effecting rotation of the mobile body portion such that the at least one microwave radiometer provides a vertical scanning below and above the mobile platform.

Klein, Marian↗

Bayesian calibration of a physics-based crystal plasticity and damage model

In this work, we present a model parameter calibration procedure for a physics-based crystal plasticity model. The calibration process utilizes a powerful statistics-based Bayesian calibration method. Calibration of the crystal plasticity parameters makes use of experimentally-measured data, i.e. compressive stress–strain response, from $\langle$100$\rangle$ and $\langle$123$\rangle$ single crystal copper dynamically loaded via Kolsky bar tests. The calibration of damage parameters is achieved using experimentally-measured free-surface velocity history data from plate impact test on $\langle$100$\rangle$ and $\langle$110$\rangle$ single crystal copper, which generates shock compression followed by dynamic tensile failure. A validation assessment is then carried out by comparing the calibrated model predictions and experimental measurements of the dynamic tensile damage generated in an impacted bicrystal copper plate. Lastly, a model-informed rationale for the experimentally-observed dependence of the spatial distribution of ductile damage (porosity) on crystallography is provided.

42 ENGINEERING↗

An investigation into force-moment calibration techniques applicable to a magnetic suspension and balance system

The problem of determining the forces and moments acting on a wind tunnel model suspended in a Magnetic Suspension and Balance System is addressed. Two calibration methods were investigated for three types of model cores, i.e., Alnico, Samarium-Cobalt, and a superconducting solenoid. Both methods involve calibrating the currents in the electromagnetic array against known forces and moments. The first is a static calibration method using calibration weights and a system of pulleys. The other method, dynamic calibration, involves oscillating the model and using its inertia to provide calibration forces and moments. Static calibration data, found to produce the most reliable results, is presented for three degrees of freedom at 0, 15, and -10 deg angle of attack. Theoretical calculations are hampered by the inability to represent iron-cored electromagnets. Dynamic calibrations, despite being quicker and easier to perform, are not as accurate as static calibrations. Data for dynamic calibrations at 0 and 15 deg is compared with the relevant static data acquired. Distortion of oscillation traces is cited as a major source of error in dynamic calibrations.

Eskins, Jonathan↗