Building envelope modeling calibration using aerial thermography
Not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
Explore the source record for details and available documents.
A calibration technique is proposed that will allow the calibration of certain angular measurement devices without requiring the use of absolute standard. The technique assumes that the device to be calibrated has deterministic bias errors. A comparison device must be available that meets the same requirements. The two devices are compared; one device is then rotated with respect to the other, and a second comparison is performed. If the data are reduced using the described technique, the individual errors of the two devices can be determined.
The Federal Aviation Administration (FAA) is implementing a satellite-based navigation system for aircraft using the Global Positioning System (GPS). Positioning accuracy of a few meters will be achieved by broadcasting corrections to the direct GPS signal. These corrections are derived using the wide-area augmentation system (WAAS), which includes a ground network of at least 24 GPS receivers across the Continental US (CONUS). WAAS will provide real-time total electron content (TEC) measurements that can be mapped to fixed grid points using a real-time mapping algorithm. These TECs will be converted into vertical delay corrections for the GPS L1 frequency and broadcast to users every five minutes via geosynchronous satellite. Users will convert these delays to slant calibrations along their own lines-of-sight (LOS) to GPS satellites. Uncertainties in the delay calibrations will also be broadcast, allowing users to estimate the uncertainty of their position. To maintain user safety without reverting to excessive safety margins an empirical model of user calibration errors has been developed. WAAS performance depends on factors that include geographic location (errors increase near WAAS borders), and ionospheric conditions, such as the enhanced spatial electron density gradients found during ionospheric storms.
NASA SSC maintains four ASD FieldSpec FR spectroradiometers: 1) Laboratory transfer radiometers; 2) Ground surface reflectance for V&V field collection activities. Radiometric Calibration consists of a NIST-calibrated integrating sphere which serves as a source with known spectral radiance. Spectral Calibration consists of a laser and pen lamp illumination of integrating sphere. Environmental Testing includes temperature stability tests performed in environmental chamber.
A radiometric calibration assessment of the AWiFS (Advanced Wide Field Sensor) on the Indian Remote Sensing Resourcesat-1 satellite was performed by the NASA Applied Research & Technology Project Office (formerly the Applied Sciences Directorate) at the John C. Stennis Space Center. A reflectance-based vicarious calibration approach, requiring ground-based measurements coincident with satellite acquisitions and radiative transfer calculations, was used to estimate at-sensor radiance. The AWiFS is a 4-band, multispectral, moderate-resolution (60 m) imaging sensor that operates in the visible through short-wave infrared spectrum and is currently being considered as a Landsat-like alternative. Several study sites near the Stennis Space Center that attempted to span the dynamic range of the sensor were employed. Satellite at-sensor radiance values were compared to those estimated to determine the sensor's radiometric accuracy. The results of this evaluation provide the user community with an independent assessment of the radiometric accuracy of AWiFS image products, which are commercially available through GeoEye. These results are an extension of an independent assessment made by the University of Arizona Remote Sensing Group, the South Dakota State University Satellite Calibration Group & Image Processing Lab, and the NASA Applied Sciences Directorate at the John C. Stennis Space Center the previous year.
The very low signal-to-noise ratios of the 1064 nm CALIOP molecular backscatter signal make it effectively impossible to employ the "clear air" normalization technique typically used to calibrate elastic back-scatter lidars. The CALIPSO mission has thus chosen to cross-calibrate their 1064 nm measurements with respect to the 532 nm data using the two-wavelength backscatter from cirrus clouds. In this paper we discuss several known issues in the version 3 CALIOP 1064 nm calibration procedure, and describe the strategies that will be employed in the version 4 data release to surmount these problems.
Deep convective clouds (DCCs) are ideal visible calibration targets because they are bright nearly isotropic solar reflectors located over the tropics and they can be easily identified using a simple infrared threshold. Because all satellites view DCCs, DCCs provide the opportunity to uniformly monitor the stability of all operational sensors, both historical and present. A collective DCC anisotropically corrected radiance calibration approach is used to construct monthly probability distribution functions (PDFs) to monitor sensor stability. The DCC calibration targets were stable to within 0.5% and 0.3% per decade when the selection criteria were optimized based on Aqua MODerate Resolution Imaging Spectroradiometer 0.65-micrometer-band radiances. The Tropical Western Pacific (TWP), African, and South American regions were identified as the dominant DCC domains. For the 0.65-micrometer band, the PDF mode statistic is preferable, providing 0.3%regional consistency and 1%temporal uncertainty over land regions. It was found that the DCC within the TWP had the lowest radiometric response and DCC over land did not necessarily have the highest radiometric response. For wavelengths greater than 1 micrometer, the mean statistic is preferred, and land regions provided a regional variability of 0.7%with a temporal uncertainty of 1.1% where the DCC land response was higher than the response over ocean. Unlike stratus and cirrus clouds, the DCC spectra were not affected by water vapor absorption.
The SMAP is one of four first-tier missions recommended by the US National Research Council's Committee on Earth Science and Applications from Space (Earth Science and Applications from Space: National Imperatives for the Next Decade and Beyond, Space Studies Board, National Academies Press, 2007). The observatory was launched on Jan 31, 2015. The goal of the SMAP is to measure the global soil moisture and freeze/thaw from space. The L-band radiometer is the passive portion of the spaceborne instrument. It measures all four Stokes antenna temperatures and outputs counts. The Level 1B Brightness Temperature (L1B_TB) science algorithm converts radiometer counts to the Earths surface brightness temperature. The results are reported in the radiometer level 1B data product together with the calibrated antenna temperature (TA) and all of the corrections to the unwanted sources contribution. The calibrated L1B data product are required to satisfy the overall radiometer error budget of 1.3 K needed to meet the soil moisture requirement of 0.04 volumetric fraction uncertainty and the calibration drift requirement of no larger than 0.4 K per month.
The SMAP is one of four first-tier missions recommended by the US National Research Council's Committee on Earth Science and Applications from Space (Earth Science and Applications from Space: National Imperatives for the Next Decade and Beyond, Space Studies Board, National Academies Press, 2007)]. The observatory was launched on Jan 31, 2015. The goal of the SMAP is to measure the global soil moisture and freeze/thaw from space. The L-band radiometer is the passive portion of the spaceborne instrument. It measures all four Stokes antenna temperatures and outputs counts. The Level 1B Brightness Temperature (L1B_TB) science algorithm converts radiometer counts to the Earths surface brightness temperature. The results are reported in the radiometer level 1B data product together with the calibrated antenna temperature (TA) and all of the corrections to the unwanted sources contribution. The calibrated L1B data product are required to satisfy the overall radiometer error budget of 1.3 K needed to meet the soil moisture requirement of 0.04 volumetric fraction uncertainty and the calibration drift requirement of no larger than 0.4 K per month.
The Moderate Resolution Imaging Spectroradiometer (MODIS) instruments aboard Terra and Aqua satellites are radiometrically calibrated on-orbit with a set of onboard calibrators (OBCs), including a solar diffuser, a blackbody, and a space view port through which the detectors can view the dark space. As a whisk-broom scanning spectroradiometer, thirty-six MODIS spectral bands are assembled in the along-scan direction on four focal plane assemblies (FPAs). These bands capture images of the same target sequentially with the motion of a scan mirror. Then the images are coregistered onboard by delaying the appropriate band-dependent amount of time, depending on the band locations on the FPA. While this coregistration mechanismis functioning well for the far-field remote targets such as earth view scenes or the moon, noticeable band-to-band misregistration in the along-scan direction has been observed for near field targets, particularly in OBCs. In this paper, the misregistration phenomenon is presented and analyzed. It is concluded that the root cause of the misregistration is that the rotating element of the instrument, the scan mirror, is displaced from the focus of the telescope primary mirror. The amount of the misregistrationis proportional to the band location on the FPA and is inversely proportional to the distance between the target and the scan mirror. The impact of this misregistration on the calibration of MODIS bands is discussed. In particular, the calculation of the detector gain coefficient m1of bands 8-16 (412 nm 870 nm) is improved by up to 1.5% for Aqua MODIS.
Satellite imager calibration teams are tasked with maintaining stable measurement records to facilitate reliable monitoring of geophysical parameters and ensure dependable input for forecast models. Satellite imagers are neither uniformly calibrated nor radiometrically scaled to a common reference standard. Consistent inter-calibration between various earth-orbiting satellite imager pairs is a critical step in the creation of seamless earth-scene reflectance data records over time for input to higher level algorithms that retrieve earth system climate-sensitive properties. Each imager inherently by virtue of its optics (and associated properties like spectral response etc.) and orbit will have a unique measurement of the same earth-scene reflected signal. A key part of this is the computationally efficient and optimal identification and prediction of science opportunities where the imager pairs from the irrespective earth-orbits near-simultaneously view the same stable terrestrial targets with nearly identical viewing and solar geometry.
2,3-butanediol (2,3-BDO) is an economically important platform chemical that can be used in a variety of chemical feedstocks, liquid fuels, and biosynthetic building blocks. While 2,3-BDO can be efficiently produced by fermentation, the fermentation requires continuous monitoring and control to maximize 2,3-BDO yields and minimize inhibitory coproducts. Because of the time required for sampling and at-line measurement of fermentation samples with high pressure liquid chromatography (HPLC), the ability for operators to perform real-time modification to fermentation conditions is limited. To overcome this challenge, researchers from the National Renewable Energy Laboratory (NREL) have developed a calibration model which can predict the concentration of several analytes in real-time using near-infrared (NIR) spectra of the filtered fermentation broth. While significantly reducing the need for off-line sampling, NREL expects this technology to play a critical role in maximizing 2,3-BDO production. 2,3-butanediol (2,3-BDO) is a useful chemical platform that can be used to create a variety of products. For instance, 2,3-BDO can be (1) dehydrated and converted into methyl ethyl ketone, a liquid fuel additive or (2) deoxydehydrated into 1,3-butadiene for synthetic rubber, which can also be oligomerized in high yields to gasoline, diesel, and jet fuel. In order to maximize 2,3-BDO production, frequent measurement of fermentation samples is needed, as small changes in oxygen concentration can drive the fermentation to undesired products. For example, oxygen-deficient conditions result in glycerol production, while excess oxygen concentrations result in acetoin production. This results in the need for measuring dissolved oxygen, glucose, and xylose concentrations in order to optimize the aeration rate of the fermentation. Traditional monitoring methods occurs off-line and can take up to 30 minutes per sample. With multiple fermenters and high-pressure liquid chromatography (HPLC) injectors, resulting in the need for multiple samples, the sampling process can take hours to complete. NREL’s calibration model can predict the glucose, xylose, 2,3-BDO, acetoin, and glycerol concentrations from NIR spectra of filtered fermentation liquor samples. Using a partial least-squares (PLS) calibration model, NREL’s model can monitor the concentration of these analytes during subsequent fermentations at bench- and pilot-scale, demonstrating the utility of NIR spectroscopy combined with chemometrics for real-time, at-line monitoring of 2,3-BDO fermentations.
Improved calibration techniques - weekly noise temperature calibrations for Mars and Venus Deep Space Stations
A method is described for calibrating cameras including radial lens distortion, by using known points such as those measured from a calibration fixture. The distortion terms are relative to the optical axis, which is included in the model so that it does not have to be orthogonal to the image sensor plane.
To aid in calibrating and monitoring the performance of the NASA scatterometer (NSCAT), a calibration ground station(CGS) was operated in White Sands, New Mexico from mid November 1996 through February 1997.
The infra-red video bolometer (IRVB) is a diagnostic equipped with an infra-red camera that measures the total radiated power in thousands of lines of sight within a large field of view. Recently validated in MAST-U [Fderici et al., Rev. Sci. Instrum. 94, 033502 (2023)], it offers a high spatial resolution map of the radiated power in the divertor region, where large gradients are expected. The IRVB’s sensing element comprises a thin layer of high Z absorbing material, typically platinum, usually coated with carbon to reduce reflections [Peterson et al., Rev. Sci. Instrum. 79, 10E301 (2008)].Here, the possibility of using a relatively inert material such as titanium, is explored that can be produced in layers up to 1 μm compared to 2.5 μm for Pt and then coat it with Pt of the desired thickness (0.3 μm per side here) and carbon. This leads to a higher temperature signal (about 3 times) and better spatial resolution (about 4 times), resulting in higher accuracy in the measured power [Peterson et al., Rev. Sci. Instrum. 79, 10E301 (2008)]. This assembly is also expected to improve foil uniformity, as the Pt layer is obtained via deposition rather than mechanical processes [Mukai et al., Rev. Sci. Instrum. 87, 2014 (2016)].Given its multi-material composition, measuring the thermal properties of the foil assembly is vital. Various methods using a calibrated laser as a heat source have been developed, analyzing the temperature profile shape [Sano et al., Plasma and Fusion Res. 7, 2405039 (2012)] and [Mukai et al., Rev. Sci. Instrum. 89, 10E114 (2018)] or fitting the calculated laser power for different intensities and frequencies [Fderici et al., Rev. Sci. Instrum. 94, 033502 (2023)]. Here, a simpler approach is presented, which relies on analyzing the separate components of the foil heat equation for a single laser exposure in a given area. This can then be iterated over the entire foil to capture local deviations.
DarkSide-50 has demonstrated the high potential of dual-phase liquid argon time projection chambers in exploring interactions of WIMPs in the GeV=c 2 mass range. The technique, based on the detection of the ionization signal amplified via electroluminescence in the gas phase, allows us to explore recoil energies down to the sub-keV range. We report here on the DarkSide-50 measurement of the ionization yield of electronic recoils down to ~180 eV er , exploiting 37 Ar and 39 Ar decays, and extrapolated to a few ionization electrons with the Thomas-Imel box model. Further, we present a model-dependent determination of the ionization response to nuclear recoils down to ~500 eV nr , the lowest ever achieved in liquid argon, using in situ neutron calibration sources and external datasets from neutron beam experiments.