SSTDR and FDR Detection of Un-Energized and Energized Cable Anomalies Including Thermal Degradation Using Machine Learning

Historically, cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, continued use of these cables must shift to a performance-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. A variety of cable tests are available and are commonly applied during outages when the cables can be taken out of service. Frequency domain reflectometry (FDR) is one of these test methods that is being more broadly accepted and used because it not only detects anomalies along the cable with a low-voltage signal that does not stress the cable insulation, but the technique also locates the anomalies. This supports follow-up local inspection and local repair or partial replacement of a damaged cable segment. Currently, FDR testing is only applied to cables that are taken out of service since the test instrument would be damaged by operational voltages.

36 MATERIALS SCIENCE↗

Residual resistance ratio measurement system for Nb 3 Sn wires extracted from Rutherford cables

Residual resistance ratio (RRR) of superconducting strands is an important parameter for magnet electrical stability. RRR serves as a measure of the low-temperature electrical conductivity of the copper within a conductor that has a copper stabilization matrix. For Nb 3 Sn, due to the need of a reaction heat treatment, the technical requirements for high quality measurements of strands extracted from Rutherford cables are particularly demanding. Quality of wire, cabling deformation, heat treatment temperature, heat treatment atmosphere, sample handling, and measurement methods can all affect the RRR. Therefore, as an integral part of the electrical quality control (QC) of Nb 3 Sn Rutherford cables manufactured at the Lawrence Berkeley National Laboratory, it was prudent that we established a RRR measurement system that can isolate the assessment of cable-fabrication-related impacts from sample preparation and measurement factors. Here we describe a bespoke cryocooler-based measurement system, capable of measuring RRR of over 80 samples in a single cooldown. The samples are mounted on custom-designed printed circuit boards that accommodate the shape of strands extracted from a Rutherford cable without added deformation, which we will show is critical in ensuring that the measurements accurately represent the RRR values of the conductor within the cable. Using this sample mounting solution, we routinely measure the overall RRR of the strand as well as individual intra-strand sections corresponding to both cable edges and cable broad faces with high reproducibility. Such measurements provide valuable information on the variation of RRR along the length of the strands as well as across strand productions and cable runs over time.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Width-bending characteristic of REBCO HTS tape and flat-tape Rutherford-type cabling

Abstract The width-bending behaviors for a rare earth barium copper oxide (REBCO) high-temperature superconducting (HTS) tape have been investigated. It has been found experimentally that the width-bending strain of a Yttrium Barium Copper Oxide (YBCO) tape does not degrade the critical current as much as is expected from the axial strain. The critical current is not directly affected by the width-bending strain but by the axial strain, which the width-bending strain generates by the Poisson effect. Since Poisson’s ratio is about 0.3, the axial strain effective on the critical current is about 30% of the width-bending strain. Therefore, the width-bending strain of even 1.5% degrades the critical current by only 15% if the REBCO layer side is bent inward. However, the critical current degraded by more than 70% when the REBCO layer is outward. The width-bending effects on the critical current have been further examined, considering Poisson’s ratio changes and the neutral plane shift of the REBCO tape substrate. Those changes would occur when the material yields due to severe width-bending. Based on the width-bending of REBCO tapes, flat-tape Rutherford-type cabling is discussed. A REBCO Rutherford-type cable can provide various advantages, especially for narrow-tape cabling. The flat-tape Rutherford-type cable has better characteristics against an electromagnetic transverse Lorentz force. Furthermore, the tape length of the cable can be approximately the same as the cable length allowing for excellent tape usage. REBCO Rutherford-type cabling will be a promising high-current, high-field cabling method using thin substrate REBCO tapes. It will be useful for AC ramp-field and pulse-field applications with low AC losses and low shield currents. It notes that the filaments in the cable are symmetrically distributed in parallel. Therefore, each filament’s inductance is uniform, and a uniform current distribution among the filaments can be obtained.

Physics↗

Tape-in-tape-out (TITO): a new approach for in-situ contact resistance measurements in high temperature superconducting CORC® cables

One of the ongoing development challenges with ReBCO high-temperature superconducting (HTS) cables is normal zone initiation and local heating, which is associated with over-critical current flowing through and around local performance reductions in individual tapes. Although inter-tape contact resistances are well-reported for individual tapes and HTS cables, these measurements are a challenge in CORC® cables as current percolates through much of the cable. In this work, developments in tape-in-tape-out (TITO) automated individual tape powering experiments are presented, and a simplified modeling approach for current percolation in CORC® cables is developed. An optimization is formulated to fit the model parameters to a large set of TITO experiments on a single cable, allowing the layer-dependent inter-tape contact resistance to be extracted. Measurements are presented and discussed for a straight CORC® cable and a cable bent to a 152 mm and 76 mm radius. The approach provides both quantitative insight and facilitates better understanding of current sharing phenomena in HTS cables.

Teyber, Reed↗

Effect of Mechanical Deformation on the Dielectric Electric Field in Dynamic Umbilical Cables

Wave energy converter (WEC) systems have unique umbilical cable design requirements compared to conventional marine designs. Due to their dynamic nature, WEC umbilical cables are required to handle increased loads and larger motions over longer deployment scenarios. However, the life expectancy of dynamic umbilical cables is predominantly analyzed for mechanical fatigue, with little consideration given to the effect of mechanical stress on the response of the dielectric as it has been previously assumed that the non-polymeric components will fail prior to the polymeric components. In this work, we explore the effects of mechanical bending on the concentration of the electric field in the insulation of a conceptual three-core dynamic umbilical cable to determine the limiting requirements for life expectancy. A conceptual industrial schematic of a medium voltage dynamic umbilical cable was used as the basis for the WEC system under study. Simulations on the dynamic umbilical cable were performed using COMSOL Multiphysics®. Mechanical loads up to the calculated limit (2.64 m minimum bend radius or 388 kN transverse load) were applied to the dynamic umbilical in a step-wise fashion with one end of the umbilical cable fixed. One-way coupling in three-dimensions was conducted by first determining the engineering strains, then using the engineering strains as the initial condition for determination of the Green-Lagrange strains, and lastly calculating the electric field in the deformed dielectric. Based upon the input load, deformation of the dielectric at the minimum bend radius produced an increase in the electric field of more than 12% when compared to the undeformed umbilical cable, which may lead to dielectric breakdown of the insulation prior to mechanical failure of the umbilical cable.

Spencer, Mychal P.↗

Temperature Dependence of FDR Response for Thermally Aged Low-Voltage Cables

Frequency Domain Reflectometry (FDR) has attracted significant attention for use in nuclear power plants (NPPs) for non-destructive cable health monitoring. However, cable aging detection using FDR faces challenges due to its high sensitivity to environmental factors such as temperature, vibrations, proximity to other cables, and so on. This work aims to evaluate the influence of measurement temperature on the FDR reflected signal in a low voltage cable undergoing accelerated thermal aging. A 100 ft long multi-core low-voltage unshielded power cable insulated with flame retardant ethylene propylene rubber (FR-EPR) and covered by a chloro-polyethylene (CPE) jacket was selected for this study. The cable was energized during aging by a 480 VAC 3-phase motor, and a 30 ft mid-section of this cable was routed through an air circulating oven held at 140 °C for up to an effective aging time of 62 days. FDR measurements were taken periodically with the oven on (at 140 °C) and with the oven off (at 22 °C). A comparative analysis of data collected at both temperatures showed that the FDR response was strongly dependent on measurement temperature. FDR measurements at ambient temperature showed large peaks corresponding to impedance changes in the aged section of the cable after 3 days of aging. These peaks continued to rise steadily with increasing aging time. However, for measurements taken at 140 °C, slowly rising peaks in the oven region (aged section) were observed only after a lead time of 23 days of aging. This work highlights the importance of measurement temperature on the performance of FDR as a condition monitoring tool for aging cables.

Sriraman, Aishwarya↗

3D Frequency Domain Reflectometry Digital Twin of an Electrical Cable: A First Glance

Electrical cables within nuclear power plants (NPPs) are critical components required for power, control, and instrumentation systems which may be exposed to stressors, such as elevated temperatures and gamma radiation. Such stressors can lead to a reduction in the remaining useful life of electrical cables, jeopardizing the safety of NPP systems. To evaluate the effect of stressors on the degradation of electrical cables, electrical reflectometry methods are commonly employed. Frequency domain reflectometry (FDR) is a non-destructive electrical reflectometry method that uses transmission line theory to detect degradation or impedance changes within electrical cables. However, in most cases FDR is only applied to de-energized cables, limiting the application in NPPs as the cable system must be taken offline. In this work, we explore the development of an FDR digital twin to predict the degradation of an electrical cable exposed to elevated temperature, which is expected to reduce the need for offline FDR. A 3-conductor low-voltage electrical cable was selected for evaluation of the digital twin. The fully three-dimensional digital twin was developed in COMSOL using the RF module. A cable length of 30-m and frequency bandwidth of 400 MHz was selected to mimic real-world application of FDR. Over a 1-m region, the permittivity of the insulation was varied by up to 20% to model thermal degradation. The results demonstrate accurate detection of the insulation damage region, supporting further investigation of the FDR digital twin using real-world data and machine learning for predictive damage estimation or remaining lifetime.

Spencer, Mychal P.↗

Transition to Online Cable Insulation Condition Monitoring

Nuclear power plant cables were originally qualified for 40 year life and generally have not required specific test verification to assure service availability through the initial plant qualification period. However, license renewals to 60 and 80 years of operation require a cable aging management program that depends on some form of test and verification to assure fitness for service. Environmental stress (temperature, radiation, chemicals, water, and mechanical) varies dramatically within a nuclear power plant and, in some cases, cables have degraded and required repair or replacement before their qualified end-of-life period. In other cases, cable conditions have been mild and dependable cable performance confirmed to extend well beyond the initial qualified life. Most offline performance-based testing requires cables to be de-coupled and de-energized for specially trained technicians to perform testing. These offline tests constitute an expensive operational burden that limits the economic viability of nuclear power plants. Although initial investment may be higher, new online test practices are emerging as options or complements to offline testing that avoid or minimize the regularly scheduled offline test burden. These online methods include electrical and fiber-optic partial discharge measurement, spread spectrum time or frequency domain reflectometry, distributed temperature profile measurements, and local interdigital capacitance measurement of insulation characteristics. Introduction of these methods must be supported by research to confirm efficacy plus either publicly financed or market driven investment to support the start-up expense of cost-effective instrumentation to monitor cable condition and assure reliable operation. This work summarizes various online cable assessment technologies plus introduces a new cable motor test bed to assess some of these technologies in a controlled test environment.

Glass, Samuel W.↗

Ensuring a Nuclear Power Plant Safe State Following an EMP Event - Task 7 Deliverable: EMP Testing of Secondary Coupling to Instrumentation Cables

Sandia National Laboratories performed tests to address the potential vulnerability concerns of a coupled High-Altitude Electromagnetic Pulse (HEMP) inducing secondary coupling onto critical instrumentation and control cables in a nuclear power plant, with specific focus on early-time HEMP. Three types of receiving cables in nine configurations were tested to determine transfer functions between two electrically separated cables referenced to the common mode input current on the transmitting cable. One type of transfer function related the input short circuit current and resulting open circuit voltage on the receiving cable. The other transfer function related the input short circuit current and the resulting short circuit current on the receiving cable. A 500 A standard HEMP waveform was input into the transfer functions to calculate peak coupling values on the receiving cables. The highest level of coupling using the standard waveform occurred when cables were in direct contact, with a peak short circuit current of 85 A and open circuit voltage of 9.8 kV, while configurations with separated cables predicted coupling levels of less than 5 A or 500 V.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Implementation and Verification of Cable Bending Stiffness in MoorDyn

The relatively large motions experienced by floating wind turbines and wave energy converters pose a challenge for power cables, whose internal components provide significant bending resistance and are sensitive to deformation. The behavior and associated design considerations of power cables in these highly dynamic applications make coupled analysis relevant for design. Bending stiffness capabilities have recently been added to the lumped-mass mooring dynamics model MoorDyn to enable simulation of dynamic power cables. MoorDyn is a common modeling choice for floating wind energy simulation (often coupled with OpenFAST) and floating wave energy converter simulation (often coupled with WEC-Sim) but the model’s previous line elasticity formulation only considered axial stiffness. To properly capture the dynamics of power cables, a bending stiffness model has been added that approximates cable curvature based on the difference in tangent vectors of adjacent elements. The resulting bending moment is realized by applying forces on adjacent nodes, enabling cable modeling while leaving the underlying lumped-mass formulation unchanged. In this paper, the new bending stiffness implementation is verified in static conditions against analytical solutions and then in a dynamic power cable scenario in comparison with the commercial simulator OrcaFlex. The dynamic scenario uses prescribed motions and includes wave loadings on the cable. Results indicate correct implementation of bending stiffness and show close agreement with OrcaFlex.

50 EE - Wind and Water Power Program - Water (EE-4↗

Voltage-Current Behavior of a Superconducting STAR ® Wire in a 6-Around-1 Cable Configuration

A 6-around-1 transposed cable using superconducting STAR® wires can be useful for future circular collider applications. We made three cable samples using single STAR® wires with a diameter of 1.3 mm. The first two samples, made with a cabling machine, used STAR® wires consisting of a 0.7 mm diameter Nb-Ti core. The third cable sample was manually wound and used a STAR® wire made with a 0.81 mm diameter Cu core. The first sample showed severe degradation after the cable was bent to a 75 mm radius. The current-carrying capability of the innermost and outermost REBCO tapes in the STAR® wire degraded by 42% to 98% and the middle REBCO tapes remained intact. This was also the case for the second and straight cable sample. After fabrication of the third cable sample, we observed only about 5% reduction in the current along the wire, measured at different locations inside the terminations. Finally, the results indicate that the differences in architecture or fabrication of the STAR® wires could have caused differences in critical current retention after cabling.

6-around-1 cable↗

Spread spectrum time domain reflectometry (SSTDR) and frequency domain reflectometry (FDR) cable inspection using machine learning

Cables are initially qualified for nuclear power plant use for 40 years. As plants extend their operating license to 60 and 80 years, justification for continued cable use must shift to a condition-based approach since it is cost prohibitive to completely replace cables that are likely still capable of performing their design function. The Pacific Northwest National Laboratory (PNNL) Accelerated and Real Time Experimental Nodal Analysis (ARENA) cable motor test bed was used to test the response of a commercial spread spectrum time domain reflectometry (SSTDR) system, a laboratory instrument software-controlled SSTDR, and a vector network analyzer-based frequency domain reflectometry (FDR) system to various cable anomalies. The three instrument systems were able to interrogate cables over a range of frequency bandwidths that can be helpful for human data analysis. Data were subjected to supervised and unsupervised machine learning (ML) analyses to distinguish normal undamaged cable responses from anomalous cable responses. Both supervised and unsupervised ML approaches produced encouraging results with an undamaged/anomalous prediction accuracy from 0.69% to 0.87%. Recommendations for further development and field implementation include increased and more balanced sample sets particularly including more training data.

SSTDR, FDR, Reflectometry, Machine Learning, ARENA↗

Photovoltaic Cable Jackets: A Comparison of Representative Products Using Combined-Accelerated Stress Testing [Slides]

Photovoltaic (PV) cables facilitate the distribution of electricity collected from modules to the energy grid. Durable cabling enables continuous operation of PV installations, whereas cables with a lifetime less than the modules must be replaced - reducing electricity generation and adding to the operating expense. This study primarily focusses on the aging of the key cable types using the combined-accelerated stress testing (C-AST) protocol. Representative cables for utility, building, and control/auxiliary applications were examined. Cable jacket materials examined include: polyolefin, polyethylene, polyamide, poly(vinyl chloride), chlorinated polyethylene, thermoplastic elastomer, and ethylene propylene diene monomer rubber. Specimen characterizations applied include: optical microscopy, mechanical profilometry, instrumented indentation, scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDS), Fourier-transform infrared spectroscopy (FTIR), thermogravimetric analysis (TGA), and differential scanning calorimetry (DSC). A variety of performance and durability characteristics were observed, depending on the base material, polymer formulation, and jacket color. The results from C-AST are analyzed and discussed relative to a recent industry survey on electronic balance of system components in addition to a recent study where similar cables were aged using steady state ultraviolet weathering (International Electrotechnical Commission Technical Specification 62788-7-2). Recommendations are made for the screening, industry qualification, and service life prediction of PV cable jackets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Status of Cable Aging Knowledge Gaps Identified in the Expanded Materials Degradation Assessment (EMDA)

This report summarizes research relevant to cable aging knowledge gaps identified in NUREG/CR-7153, “Expanded Materials Degradation Assessment (EMDA) Volume 5: Aging of Cables and Cable Systems” (EMDA Vol. 5), performed since the EMDA Vol. 5 was published in 2014. It begins with a discussion of the status of cables in long-term operation of U.S. nuclear power plants (NPPs) and the most common cables found in NPP containment. Next, the major polymer cable insulations, and the mechanisms of concern for degradation of those polymers in service are reviewed. A description of the environmental qualification (EQ) process historically used for safety-related cables is provided as is a review of the potential concerns with that process highlighted in the EMDA Vol. 5. Research addressing each of these is then reviewed. Finally, three potential strategies to support continued safe operation of aging cables are proposed: advanced condition-based verification, targeted material aging studies, and predictive simulation.

42 ENGINEERING↗

Spread Spectrum Time-Domain Reflectometry and Frequency Domain Reflectometry to Detect Shielded and Unshielded Cable Moisture Exposure

This work evaluates the feasibility to extend spread spectrum time-domain reflectometry (SSTDR) and frequency domain reflectometry (FDR) electrical cable testing to characterize whether an electrical cable is submerged in water or not and where it may be submerged. Using PNNL’s ARENA cable and motor test bed, shielded and non-shielded electrical cables were evaluated using SSTDR and FDR methods to detect and locate electrical cable exposure to water. Both SSTDR and FDR showed the presence of water with a non-shielded cable. Moisture was only detectable with the shielded cable if the insulation was damaged.

reflectometry cable test, cable moisture detection↗

AC loss and contact resistance in REBCO CORC ® , Roebel, and stacked tape cables

Abstract Many high-temperature superconductor (HTS) applications require superconducting cables with high currents while operating in an alternating magnetic field. HTS cables should be composed of numerous superconducting tapes to achieve the required current capacity. Alternating current and magnetic fields cause AC losses in such cables and can provoke conductor instability. AC losses and contact resistances were measured of several cable designs based on commercially available REBCO tapes at the University of Twente. The AC loss was measured under identical conditions for eight REBCO conductors manufactured according to three types of cabling methods—CORC ® (Conductor on Round Core), Roebel, and stacked tape, including a full-size REBCO CICC (cable in conduit conductor). The measurements were done at T = 4.2 K without transport current in a sinusoidal AC magnetic field of 0.4 T amplitude and frequencies from 5 to 55 mHz. The AC loss was measured simultaneously by calibrated gas flow calorimeter utilizing the helium boil-off method and by the magnetization method using pick-up coils. Also, the AC loss of two CORC® conductors and a Roebel cable was measured at 77 K. Each conductor was measured with and without background field of 1 T. The measured AC coupling loss in the CORC ® and Roebel conductors is negligible at 4.2 K for the applied conditions while at 77 K coupling loss was observed for all conductors. The absence of coupling loss at 4.2 K can be explained by shielding of the conductor interior; this is confirmed with measurement and calculation of the penetration field of CORC ® and Roebel cables. The inter-tape contact resistance was measured for CORC ® and stacked tape samples at 4.2 and 77 K. It was demonstrated that a short heat treatment of CORC ® conductor with solder-coated tapes activates tape-to-tape soldering and decreases the contact resistance. The reduction of contact resistance by two orders in magnitude to tens of nΩm is comparable with the interstrand contact resistance in ITER Nb 3 Sn type conductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Performance of low-loss demountable joints between CORC ® cable-in-conduit-conductors at magnetic fields up to 8 T developed for fusion magnets

Abstract High-temperature superconductors (HTS) are promising candidates for use in the high-field magnets needed in particle accelerators and fusion reactors. HTS conductor on round core (CORC ® ) cables and wires wound from ReBa 2 Cu 3 O 7- x (REBCO) coated tapes are being developed for use in high-field magnet applications including fusion magnets operating at currents beyond 80 kA, requiring them to be bundled into cable-in-conduit conductor (CICC) configurations. The use of HTS cables enable demountable superconducting fusion magnets that would allow easier access to the fusion machine for maintenance and parts replacement. Such demountable magnets require practical, low-resistance joints, capable of injecting current uniformly into the many REBCO tapes that make up different cable designs. Optimization steps on CORC ® cables have resulted in high-current terminations and joints with a joint resistance measured between a pair of 30-tape CORC ® cables of 51 nΩ at 76 K and 1.9 nΩ at 4 K. Demountable joints between CICCs consisting of six CORC ® cables arranged in flat and round configurations were also tested and compared to joints between low-temperature superconducting (LTS) CICCs consisting of NbTi Rutherford cables. Samples were paired into two configurations (LTS-to-LTS and HTS-to-HTS) with a demountable joint between them that were each tested in series with currents up to 10 000 A in an applied background magnetic field of up to 8 T. The total loop resistance of the HTS-to-HTS sample, including their terminations and joint, was about 4 nΩ at 4 K in self-field with the resistance of the copper pressed joint being less than 1 nΩ. At 8 T, the total loop resistance increased to 6.9 nΩ with the pressed joint contributing 1.4 nΩ. These initial tests prove the feasibility of producing remountable (dry) joints with low resistance between superconducting magnet windings in future compact fusion machines.

Physics↗

Evaluation of Damage in Medium Voltage Cable Using Machine Learning

Developments in cable test instrumentation coupled with artificial intelligence and machine learning (ML) to aid in interpretation of cable test signals supports the feasibility for automated analysis of reflectometry tests for low voltage power cables. This work seeks to leverage prior ML work and success for low voltage cables to evaluate potential application to medium voltage (2kV to 10kV) installations. The Accelerated and Real-Time Environmental Nodal Assessment (ARENA) Cable Motor Test Bed at Pacific Northwest National Laboratory (PNNL) was used to test a medium voltage cable with several types of damage including thermal aging and low resistance conductor-to-shield faults. The cable was tested using an inductive clamshell coupler to protect the test instruments from the energized cable voltages that would damage the test instruments if coupled directly to the energized conductor.

42 ENGINEERING↗