Performance Evaluation of Three RTU Energy Efficiency Technologies

This project was part of an effort by CLEAResult and ComEd to evaluate the energy saving potential of emerging technologies in the Chicago area. This project focused on evaluating emerging technologies related to rooftop units (RTUs). An RTU with a single-stage compressor and a constant-speed fan with an induction motor was selected as the baseline for technology comparison. Three retrofit strategies were investigated. The first two involved replacing the single-stage compressor of an RTU by either a two-stage or variable-speed compressor and adding a variable frequency drive (VFD) to the constant speed fan. The use of a multi-/variable-stage compressor improves the part-load efficiency of the compressor which will ultimately result in annual energy savings as well as peak demand shaving in some cases where the design capacity of the RTU is larger than the maximum cooling load of the building space that it is serving. The third technology was the use of a high rotor pole switched reluctance motor (SRM) as a replacement for the constant-speed supply fan. The SRM was applied in single-speed, two-stage and variable-speed compressor RTUs. SRM motors run via reluctance torque. Their stator poles are driven by direct current (DC) power and require an inverter as well as active control when using alternating current (AC) power. This inherent property results in high efficiency over a range of operating conditions. It also exhibits higher efficiency compared to variable frequency drives (VFDs) since its switching frequency is much slower (SCE, 2018).The three technologies investigated are summarized below: 1) Replacing the single-speed compressor with a two-stage compressor and adding a VFD to the supply fan. 2)Replacing the single-speed compressor with a variable-speed compressor and adding a VFD to the supply fan. 3) Replacing the constant-speed induction motor of the supply fan with a high rotor pole SRM. DOE’s building simulation platform EnergyPlus and its graphical user interface OpenStudio were used to evaluate the energy-saving potential of upgrading RTUs, by leveraging experimental data from previous research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Dual-season thermal energy storage-integrated heat pump system for load shifting: experiments, modeling and nationwide analysis

Here, this paper proposes and validates a dual-season thermal energy storage-integrated heat pump (TES-HP) system that shifts building electric load in both cooling and heating modes using a single phase-change TES. The design uses the TES as a heat sink for the condenser in summer and a heat source for the evaporator in winter, thereby reducing on-peak electric demand while ensuring compatible with existing air-distribution systems. A 14-kW TES-HP prototype with six operating modes and novel refrigerant charge management strategies was experimentally tested under varied conditions. Subsequently, data-driven polynomial performance curves were developed and validated against experiments, then coupled with a phase change material (PCM) model and a calibrated building model within a rule-based controller. Single-day case studies demonstrated effective on-peak demand reduction while maintaining thermal comfort. During cooling, hourly power was lowered by up to 1.5 kW; in heating, average hourly power decreased from over 3.5 kW to 1.8 kW, compared to an HP-only system, achieving 64.5 % load shifting, and the need for resistance heating was eliminated. Seasonal simulations showed typical on-peak electricity savings of 25–35 % in cooling and 40–65 % in heating, with the largest benefits on the hottest and coldest days. Extended response-surface analysis and nationwide mapping quantified load shifting as functions of ambient and TES temperatures, revealing a seasonal trade-off in TES phase-change temperature. These results demonstrate the TES-HP system as a practical and scalable solution for grid-interactive buildings that reduces on-peak demand and electricity use while maintaining thermal comfort and enhancing grid flexibility and reliability.

Grid-interactive buildings↗

Techno-economic feasibility of borehole thermal energy storage system connected to geothermal heat pumps for seasonal heating load of two buildings in Fairbanks, Alaska

Borehole thermal energy storage (BTES) is an effective solution for managing imbalanced heating and cooling loads in cold regions. This study evaluated the long-term feasibility of a BTES system in the Fairbanks area, Alaska, through building energy modeling, resource characterization, and numerical modeling. The system was designed to store waste heat from a nearby coal power plant during summer and provide thermal energy during winter to geothermal heat pumps supplying heating loads in two buildings. Heating load profiles were modeled for the buildings using EnergyPlus, and the results indicated the annual heating load was 5.6 times greater than the cooling load. 40 borehole heat exchangers were pre-designed approximately 100 m away from the two buildings in terms of land availability and regulatorily optimized depth. The 20-year performance of the designed BTES system under two operational scenarios—one with a 5-year preheating period and one without—was numerically modeled using subsurface temperature and properties characterized through the literature review and thermal response tests. Both scenarios demonstrated that the BTES has the capacity to fully cover the heating loads in the two buildings throughout the 20-year lifetime. Production temperatures at central wells were 33 % higher on average than at outer wells in both scenarios. The 5-year preheating period increased subsurface and extraction temperatures, and correspondingly annual average and total thermal energy production was higher for 8 years than in the scenario without the preheating period. These results highlight the long-term reliability and sustainability of the BTES system in meeting heating demands over its lifetime, with the preheating period offering potential performance improvements. Implementing the BTES system in cold regions with high heating demand, such as Fairbanks, Alaska, could provide a long-term, sustainable energy solution for managing imbalanced heating and cooling loads.

15 GEOTHERMAL ENERGY↗

ComStock Measure Documentation: Ideal Thermal Air Loads

This study provides hypothetical thermal heating and cooling loads for ComStock models representing the U.S. commercial building stock. This measure scenario removes all HVAC models from the baseline ComStock building model and instead uses "ideal air" to meet loads. "Ideal air" can be thought of as an HVAC unit that mixes air at the zone exhaust condition with the specified amount of outdoor air, and then adds or removes heat and moisture at 100% efficiency to produce a supply air stream at the specified conditions. The resulting ideal thermal loads are represented under the "district" fuel type for both heating and cooling and can be found in both annual and timeseries results in the ComStock public dataset. This measure scenario does not represent any real technology or improvement, but rather, serves as a resource for thermal heating and cooling loads for buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A sensitivity model for energy consumption in buildings. Part 1: Effect of exterior environment

A simple analytical model is developed for the simulation of seasonal heating and cooling loads of any class of buildings to complement available computerized techniques which make hourly, daily, and monthly calculations. An expression for the annual energy utilization index, which is a common measure of rating buildings having the same functional utilization, is derived to include about 30 parameters for both building interior and exterior environments. The sensitivity of a general class building to either controlled or uncontrolled weather parameters is examined. A hypothetical office type building, located at the Goldstone Space Communication Complex, Goldstone, California, is selected as an example for the numerical sensitivity evaluations. Several expressions of variations in local outside air temperature, pressure, solar radiation, and wind velocity are presented.

Lansing, F. L.↗

Desiccants enabling energy-efficient buildings: A review

Buildings account for about 39% of the total energy consumption in the United States. Developing highly energy-efficient and environmentally friendly systems that are either actively or passively integrated into buildings plays a crucial role in decarbonizing the building sector. Among various technologies, desiccant-based energy systems have received particular attention in recent years due to their unique advantages, such as being thermally driven using low-grade waste or solar energies and being reliable over a wide range of operating ranges. Extensive research efforts have been exerted on desiccant-enabled technologies at both material and system levels aiming to increase their performance and achieve high technological readiness levels. The present review paper comprehensively discusses research works made at the system level. It overviews desiccant-based air conditioning systems, desiccant-based humidity pumps, desiccant-based thermal energy storage systems, and desiccant-based appliances. The study identifies challenges and opportunities to accelerate the commercialization of desiccant-enabled technologies. It is found that desiccant materials offer great promise to improve energy efficiency and functionality of future buildings through decoupling the latent and sensible cooling loads in air conditioning systems, humidity pumps integrated into building facades, and next-generation appliances. However, commercial viability and widespread acceptance of desiccant-based systems have been hampered by several major obstacles, including liquid and air flow mal-distribution and inferior thermo-physical properties of desiccant materials resulting in low ab/adsorption and regeneration rates and bulky/costly systems.

25 ENERGY STORAGE↗

Virtual Metering for Monitoring Building Energy Consumption

The United States Department of Energy (DOE) has standard metering requirements of commercial buildings for optimizing energy performance. The guiding principles are to continuously track and optimize energy performance and install building-level meters for electricity, natural gas, and steam. Some buildings at Los Alamos National Laboratory (LANL) have physical submeters monitoring their energy consumption, but these meters have proven to be unreliable. And, in most cases, replacing them has proven to be a slow process. Installing new submeters also requires a temporary lockout of the circuit on which they are being installed. Many buildings at LANL contain laboratories with ongoing experiments or data centers, which makes an equipment power outage nearly impossible to plan. This inability to plan power outages results in long-term submeter failures. Although most submeters are eventually replaced, failures lead to missing consumption data for some unpredictable, extended time. A building automation system (BAS) is a system that provides control and monitoring on a building to maintain the operational performance of the building and occupancy comfort. Many buildings at LANL currently have a BAS, and all new renovations and installs will include installing a BAS if one does not already exist. The intended purpose for a BAS is primarily to monitor the health and efficiency of a building; however, it is also possible to calculate equipment power and energy consumption using BAS information. This project aims to use virtual meters to monitor building energy consumption as a cost-effective and minimally labor-intensive alternative to installing physical submeters. The fault detection and diagnostics tool, SkySpark, provides a centralized database for all the data from the various BAS that are active at LANL. This data includes the information that is needed to create virtual meters for heating, ventilating, and air conditioning (HVAC) systems in most buildings, including heating and cooling loads. 9 This report begins with a detailed summary of the project, including the reasoning, procedure, and results. The specific processes of creating the various virtual meters are then identified. Then the limitations are discussed. And, lastly, the results and future potential are presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermally Anisotropic Building Envelope Integration into Panelized Metal Construction: Laboratory Evaluation in Guarded Hot Box

The Thermally Anisotropic Building Envelope (TABE) is an active building envelope system that can exchange thermal energy with a storage medium to reduce the building’s energy demand. TABE redirects thermal energy along thin conductive layers in the building envelope to hydronic loops that are connected to thermal energy storage (TES), where it will be available to offset future energy demand when the conditions are favorable. TABEs can also be connected with a geothermal loop to reduce the building’s heating and cooling loads. Due to the importance of thermally conductive metal layers to TABE function, this technology has potential for easy adoption into panelized metal construction. In this study, we illustrate the construction process of prototype metal panels containing TABE and the laboratory evaluation in Oak Ridge National Laboratory’s rotatable guarded hot box. The thermal performance of the prototype panel was assessed for both baseline and operational cases and the total heat flow extracted from the panel by TABE was quantified.

Howard, Daniel↗

Performance of a Hybrid HVAC-Integrated Thermal Storage Device

Thermal equipment in buildings is a primary contributor to peak loads on the electrical grid. Thermal energy storage is a cost-effective strategy to decouple electric use from thermal loads, thus reducing grid peak costs for building owners. One method for storing thermal energy in a building is to integrate a phase change material (PCM) directly into the heating, ventilation, and air conditioning system. These systems often require additional glycol loops, pumps, valves, and heat exchangers to couple the storage to the cooling system and building space, which increases the complexity and cost. This work will discuss an alternate approach where the storage is added directly into the heat pump evaporator. A detailed two-dimensional finite difference heat transfer model of a PCM-refrigerant-glycol heat exchanger was developed to simulate the performance of this component. The fluid stream was discretized along the flow direction to capture changes in the fluid properties and local heat transfer rates, and the phase change material was discretized in both the x and y directions to capture the movement of the melt front. The model was used to understand the impact of different material and geometric properties on the charge and discharge characteristics of the device. Finally, a Ragone framework analogous to that used for electrochemical batteries was used to maximize the energy density and round-trip efficiency of the device while supplying loads appropriate for space cooling in buildings.

buildings↗

Accuracy of HVAC Load Predictions: Validation of EnergyPlus and DOE-2 using FLEXLAB Measurements

The aim of the project reported here was to better understand the level of accuracy of three building energy simulation (BES) engines (‘engines’) — EnergyPlus™, DOE-2.1e, and DOE-2.2 — by identifying and investigating significant deviations between the performance predicted by these engines and actual performance as measured in the FLEXLAB® test facility at Lawrence Berkeley National Laboratory (LBNL). The specific test conditions included some of those prescribed in ANSI/ASHRAE Standard 140 - Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs. Detailed measurements of FLEXLAB performance, including indoor temperatures and heat fluxes and air-flow and water flow rates and temperatures in the Heating, Ventilating and Air Conditioning (HVAC) system, together with hourly weather data, were recorded and used in analyzing the simulation results from EnergyPlus v8.8, DOE-2.2 v3.65 and DOE-2.1e v127. These engines are commonly used in the United States for building energy code compliance, federal, state, and utility incentives programs, as well as energy efficient design of new buildings and energy retrofit of existing buildings. Seven conventional overhead mixing ventilation scenarios were tested and each engine was found to have a similar level of agreement with the measurements of space-level heating and sensible cooling loads. These results provide useful information regarding the accuracy of these engines in predicting the cooling and heating load elements of whole building energy performance. This information is intended for practitioners who are concerned about transitioning between simulation tools with different engines and for managers of utility programs leveraging these tools for evaluating and/or projecting measure savings to be incentivized under their programs. The results of the comparisons of simulated and measured performance indicate that the predictions from all three engines are not significantly different. The 24-hour average value of the absolute mean bias indicates the likely magnitude of the error in any particular case. The average mean bias is reduced by cancelation of overprediction in one case by underprediction in another. The daytime absolute mean biases, which may be more important for both energy performance and occupant comfort, are ~6%, presumably because of the greater complexity involved in simulating in the presence of solar radiation. EnergyPlus typically overpredicts the cooling load and/or underpredicts the heating load by ~1.5% and the DOE-2 engines typically underpredict the cooling load by approximately the same amount. The Root Mean Square Error is relatively more sensitive to shorter term variations in the difference between predicted and measured loads; the three engines have similar values, ~10%, suggesting that the uncertainties in their predictions of peak loads may also be similar in magnitude. The implication of these results is that users, both designers and program analysts, can use EnergyPlus, DOE-2.1e, or DOE-2.2 to model conventional commercial buildings equipped with overhead mixing ventilation with a similar level of confidence. Further work is required to better understand the variability in the level of agreement between the engine predictions and FLEXLAB measurements, where a particular engine will agree well with FLEXLAB in some cases and not so well in others and another engine will agree or disagree in different cases. As the sources of this variability are identified and eliminated or reduced significantly, it is recommended that the experimental capabilities and methods developed in the study reported here should be applied to validating heating and cooling load calculations for spaces with different types of furniture and miscellaneous loads. These methods should then be applied to low energy space conditioning systems in EnergyPlus including, in particular, radiant slab and radiant ceiling panel cooling and heating systems and ‘mixed mode’ systems that combine mechanical cooling and natural ventilation systems, focusing on controls, including control of thermal mass. The work reported here addresses the conventional method of heating and cooling occupied spaces; other methods, such as the use of radiant heating and cooling systems have the potential to provide equivalent occupant comfort, or better, with lower energy consumption. These systems are addressed more explicitly in EnergyPlus but there is a need for empirical validation to give users the same level of confidence in modeling these systems that they have, or should have, in modeling conventional systems, based on the results presented here.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stochastic scheduling for commercial building cooling systems: considering uncertainty in zone temperature prediction

Here, this paper presents the first attempt to address the uncertainty in zone temperature prediction with stochastic optimization. The uncertain zone temperature is a process uncertainty and has not been considered in the existing stochastic optimization for building control. To fill this gap, we proposed a novel formulation of stochastic optimization to handle process uncertainty in building control. Specifically, we first examined the accuracy of a typical linear model for predicting zone temperature. We then formulated the scheduling of the building cooling system as a stochastic optimization problem over a 24-hour look-ahead period to minimize the electricity cost of the studied building cooling system. After that, we applied the proposed stochastic load scheduling (SLS) to a direct expansion (DX) cooling system that serves a medium office building. Through simulation with a detailed building energy simulation software, EnergyPlus, we evaluated the operational cost and the thermal comfort compared with a deterministic load scheduling. The operation cost of scheduling was found to vary with the level of zone temperature prediction uncertainty. The proposed SLS can mitigate the impacts of uncertain zone temperature predictions on both operational cost and thermal comfort. The evaluation results indicate that the proposed SLS works better when the uncertainty level is more significant.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Modulating thermal load through lightweight residential building walls using thermal energy storage and controlled precooling strategy

Precooling is a recognized technique for reducing cooling energy in buildings during peak hours by shifting load to off-peak hours. This technique is particularly effective in buildings with high thermal mass, because of their large thermal energy storage capacity, and in commercial buildings due to their variable electricity pricing based on time-of-use rates. Precooling in residential buildings has been a matter of limited interest in the past because of their low thermal mass and typically uniform electricity pricing rate. While previous studies on precooling primarily focused on cost savings, an important aspect of precooling is the thermal load modulation, which could be very effective in managing peak demand in lightweight residential buildings integrated with thermal energy storage systems. In this study, we examine different precooling strategies to manage the heat gains in lightweight building walls integrated with phase-change materials. We create nine different precooling profiles by controlling the interior temperature, and then evaluate the influence of the precooling profiles on four key building energy performance parameters: total heat gain, peak heat gain, maximum heat gain during peak hours, and time at which peak occurs. To thoroughly understand the fundamental physics, we first consider hypothetical climates and obtain the optimal precooling strategy required to achieve maximum peak shedding and shifting while minimizing the total heat gains. We then extend the model to Baltimore, Maryland, and estimate the benefits of the optimized precooling strategy under real conditions. The optimal precooling strategy proposed in this study can shift the peak heat gain by up to 14 hours, thereby reducing the heat gain during peak period by up to 95%, at the expense of a 23% increase in the total heat gains.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CalTestBed - Lucent Optics (CRADA Final Report)

The CRADA partner was developing a window film aimed at improving the control of the solar radiation that arrives at a building’s windows, ultimately reducing cooling loads and improving the distribution of daylight. The efforts under this CRADA were aimed at better understanding the performance of one or more prototypes of this film, with the aim of helping to narrow down the film design parameters to values more likely to achieve better performance. The technical means of achieving this project’s goals used LBNL’s world-class test facilities and expertise. These technical means included: (a) measurements of the bidirectional scattering distribution function (BSDF) of film samples, and (b) full-scale measurement of the energy (HVAC, lighting) and comfort (visual, thermal) impacts of at least one film prototype, for two solar angle “seasons” (“high” and “low” solar angle).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SESOP: Program for solar-energy heating-systems analysis

Space heating and cooling loads are calculated for each building based on outside environment, desired inside conditions, building construction and geometry, domestic power usage, occupancy rate, and occupant metabolic rate. Loads are summed to determine requirements of central and alternative utility systems.

Source record↗

Influence of Photovoltaic Shading on Rooftop Heat Transfer, Building Energy Loads, and Photovoltaic Power Output

Photovoltaic (PV) modules on building rooftops provide shade from summer heating, leading to a reduction in cooling load during hot seasons. However, PV shading also reduces passive solar heating during winter months, leading to an increase in the building heating load during cold seasons. In this study, the heat transfer performance of an enclosure formed by adjacent PV modules is analyzed for three locations in the United States, comparing the daily heat flux through rooftops for the case of a PV-shaded rooftop as well as an unshaded roof. Several result metrics are developed as part of this work, including the saved energy load (SEL), or the energy conserved by adding PV-shading to the rooftop, and the additional energy load (AEL), or the supplemental building energy required to replace shaded solar heating. Lastly, this work calculates the utility factor, being the ratio of SEL and PV power output to AEL as a metric of PV effectiveness. SELs are 5.2, 6.2, and 11.7 kWh/m 2 · year for Dayton, Boise, and Phoenix, respectively, while the AELs for the same locations are 1.6, 1.5, and 2.1 kWh/m 2 · year. The utility factors for the same three locations are 61, 71, and 79. In general, locations with hot, non-cloudy summers and clear skies in winter see the largest utility factor. Further, it is shown that PV shading can conserve building energy during the winter months by preventing radiative losses to cold winter skies.

13 HYDRO ENERGY↗

Continuous Monitoring and Partial Water Softening for Cooling Tower Water Treatment

Cooling towers are an integral component of many refrigeration systems, providing comfort or process cooling across a broad range of applications. They are the point in the system where heat is dissipated to the atmosphere through the evaporative cooling process. Cooling towers are commonly found in industrial applications and are also often used in water-cooled chilled water plants in medium to large commercial buildings. Continuous monitoring and partial water softening for cooling towers used in medium to large commercial buildings are the focus of this paper. Cooling towers consume large amounts of water. Cooling tower-related water consumption is one of largest potable water loads within buildings in the United States, with substantial building water use associated with heating and cooling. Regional water shortages have highlighted a need to reduce water consumption; the U.S. General Services Administration (GSA) and Executive Order 13834 place priority on reducing water consumption. This priority has fueled interest in the identification, investigation, and potential broad deployment of cost-effective opportunities to reduce water use, such as alternative water treatment (AWT) technologies for cooling towers. Traditional water treatment approaches use chemicals to extend the ability of the water to hold scaling minerals in suspension, minimize corrosion, and prevent biological growth. This treatment protects the chillers and cooling tower equipment; however, even when chemicals are used regularly, a certain percentage of condenser water must be drained and made up with fresh water to maintain system water quality parameters. In addition, the use of chemicals sometimes creates a waste disposal issue and can cause building owners to incur additional fees, such as disposal or wastewater charges. To manage cooling tower water treatment, GSA typically contracts with a company specializing in conventional chemical maintenance for a fixed fee. While there are many types and vendors of AWT systems, this project assesses the effectiveness of one technology provided by Aqualogix. This system is a chilled water plant monitoring and control system aimed at optimizing system performance by reducing the blowdown occurrences used to remove mineral build-up. The technology consists of two components – continuous programmable logic control (PLC) monitoring and side-stream filtration with partial water softening. PLC monitoring calculates cycles of concentration (CoC) and determines the optimum amount of blowdown water required to satisfy all water chemistry requirements. Side-stream filtration removes suspended matter and improves biocide efficacy while precisely dispensing softened water to achieve optimal makeup water hardness. Unlike other AWT systems evaluated by GSA to date, this system does not replace the legacy treatment system but is used in addition to chemical water treatment. The vendor claims their technology will reduce water consumption, water discharge, and maintenance costs. The AWT system evaluated in this demonstration is a commercialized technology. Given its commercialized state, the system evaluated in this report is at a Technology Readiness Level 9 according to National Aeronautics and Space Administration (NASA) definitions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Site dependent factors affecting the economic feasibility of solar powered absorption cooling

A procedure was developed to evaluate the cost effectiveness of combining an absorption cycle chiller with a solar energy system. A basic assumption of the procedure is that a solar energy system exists for meeting the heating load of the building, and that the building must be cooled. The decision to be made is to either cool the building with a conventional vapor compression cycle chiller or to use the existing solar energy system to provide a heat input to the absorption chiller. Two methods of meeting the cooling load not supplied by solar energy were considered. In the first method, heat is supplied to the absorption chiller by a boiler using fossil fuel. In the second method, the load not met by solar energy is net by a conventional vapor compression chiller. In addition, the procedure can consider waste heat as another form of auxiliary energy. Commercial applications of solar cooling with an absorption chiller were found to be more cost effective than the residential applications. In general, it was found that the larger the chiller, the more economically feasible it would be. Also, it was found that a conventional vapor compression chiller is a viable alternative for the auxiliary cooling source, especially for the larger chillers. The results of the analysis gives a relative rating of the sites considered as to their economic feasibility of solar cooling.

Bartlett, J. C.↗

Solar-heated and cooled savings and loan building-1-Leavenworth, Kanasas

Report describes heating and cooling system which furnishes 90 percent of annual heating load, 70 percent of cooling load, and all hot water for two-story building. Roof-mounted flat-plate collectors allow three distinct flow rates and are oriented south for optimum energy collection. Building contains fully automated temperature controls is divided into five temperature-load zones, each with independent heat pump.

Source record↗