Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “blind comparison”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Binding of stereognostically designed ligands to trivalent, pentavalent, and hexavalent f-block elements

Stability constants were determined for the complexes formed from two stereognostically designed ligands and the f-block elements Nd(III), Np(V), and Pu(VI). The ligands investigated were tris[3-(2-carboxyphenoxy)propyl]amine (NPB) and tris-N,N',N''-[2-(2-carboxy-4-ethyl-phenoxy)ethyl]-1,4,7-triazacyclononane (EETAC). A stereognostically blind ligand, nitrilotriacetic acid (NTA), was also investigated for comparison. The results suggest that there is no significant stereognostic effect for complexation of NPB or EETAC to Np(V). On the other hand, a modest stereognostic effect is seen for the NPB ligand when complexed to Pu(VI), leading to an approximately 8-fold increase in the binding strength. A more significant effect is observed for the EETAC system in which a 250-fold increase in binding is observed for Pu(VI) versus Nd(III).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Comparison of Cilostazol and Pentoxifylline for Treating Intermittent Claudication

A randomized, double-blind, placebo-controlled, parallel-group, phase III multicenter trial was performed to evaluate the relative efficacy and safety of cilostazol and pentoxifylline. The study included 54 outpatient vascular clinics, including sites at Air Force, Veterans Affairs, tertiary care, and university hospitals in the United States. Of 922 consenting patients, 698 met the inclusion criteria, were randomized, and received treatment with either cilostazol 100 mg P0 twice a day, pentoxifylline 400 mg PO 3 times a day, or placebo. Treatment was double-dummy to ensure study blindness. Efficacy was primarily established by maximal walking distance (MWD), measured with constant-speed, variable-grade treadmill testing, assessed at baseline and at 4, 8, 12, 16, 20, and 24 weeks. Mean MWD of cilostazol-treated patients (n=227) was significantly improved at every visit compared with patients who received pentoxifylline (n=232) or placebo (n=239). After 24 weeks of cilostazol, mean MWD increased 53.9% (107.3 m) from baseline, and the effect had not plateaued. This was better (P < 0.001) than the 30.4% (64.4 m) MWD improvement with pentoxifylline. MWD improvement with pentoxifylline was similar (P = 0.82) to that of placebo (64.7 m). Deaths and serious adverse event rates were similar in each group. Common side effects included headache (27.8% with cilostazol, 11.2% with pentoxifylline, 11.7% with placebo), palpitations (17.2% with cilostazol, 2.2% with pentoxifylllne, 1.3% with placebo), and abnormal stools. Cilostazol was significantly better than pentoxifylline or placebo for increasing walking distances; pentoxifylline was no better than placebo.

Dawson, David L.↗

Predicting the reliability of an additively-manufactured metal part for the third Sandia fracture challenge by accounting for random material defects

We describe an approach to predict failure in a complex, additively-manufactured stainless steel part as defined by the third Sandia Fracture Challenge. A viscoplastic internal state variable constitutive model was calibrated to fit experimental tension curves in order to capture plasticity, necking, and damage evolution leading to failure. Defects such as gas porosity and lack of fusion voids were represented by overlaying a synthetic porosity distribution onto the finite element mesh and computing the elementwise ratio between pore volume and element volume to initialize the damage internal state variables. These void volume fraction values were then used in a damage formulation accounting for growth of these existing voids, while new voids were allowed to nucleate based on a nucleation rule. Blind predictions of failure are compared to experimental results. The comparisons indicate that crack initiation and propagation were correctly predicted, and that an initial porosity field superimposed as higher initial damage may provide a path forward for capturing material strength uncertainty. Here, the latter conclusion was supported by predicted crack face tortuosity beyond the usual mesh sensitivity and variability in predicted strain to failure; however, it bears further inquiry and a more conclusive result is pending compressive testing of challenge-built coupons to de-convolute materials behavior from the geometric influence of significant porosity.

36 MATERIALS SCIENCE↗

Dark matter blind spots at one-loop

We evaluate the impact of one-loop electroweak corrections to the spinindependent dark matter (DM) scattering cross-section with nucleons (σ SI ), in models with a so-called blind spot for direct detection, where the leading-order prediction for the relevant DM coupling to the Higgs boson, and therefore σ SI , are vanishingly small. Adopting a simple illustrative scenario in which the DM state results from the mixing of electroweak singlet and doublet fermions, we compute the relevant higher order corrections to the scalar effective operator contributions to σ SI , stemming from both triangle and box diagrams involving the SM and dark sector fields. It is observed that in a significant region of the singlet-doublet model-space, the one-loop corrections “unblind” the tree-level blind spots and lead to detectable SI scattering rates at future multi-ton scale liquid Xenon experiments, with σ SI reaching values up to a few times 10 -47 cm 2 for a weak scale DM with O(1) Yukawa couplings. Furthermore, we find that there always exists a new SI blind spot at the next-to-leading order, which is perturbatively shifted from the leading order one in the singlet-doublet mass parameters. For comparison, we also present the tree-level spin-dependent scattering cross-sections near the SI blind-spot region, that could lead to a larger signal. Our results can be mapped to the blind-spot scenario for bino-Higgsino DM in the MSSM, with other sfermions, the heavier Higgs boson, and the wino decoupled.

79 ASTRONOMY AND ASTROPHYSICS↗

Planning, design and logistics of a decision analysis study: The FBI/Ames study involving forensic firearms examiners

This paper describes design and logistical aspects of a decision analysis study to assess the performance of qualified firearms examiners working in accredited laboratories in the United States in terms of accuracy (error rate), repeatability, and reproducibility of decisions involving comparisons of fired bullets and cartridge cases. The purpose of the study was to validate current practice of the forensic discipline of firearms/toolmarks (F/T) examination. It elicited error rate data by counting the number of false positive and false negative conclusions. Preceded by the experimental design, decisions, and logistics described herein, testing was ultimately administered 173 qualified, practicing F/T examiners in public and private crime laboratories. The first round of testing evaluated accuracy, while two subsequent rounds evaluated repeatability and reproducibility of examiner conclusions. This project expands on previous studies by involving many F/T examiners in challenging comparisons and by executing the study in the recommended double-blind format.

99 GENERAL AND MISCELLANEOUS↗

Propulsion Diagnostic Method Evaluation Strategy (ProDiMES) User's Guide

This report is a User's Guide for the Propulsion Diagnostic Method Evaluation Strategy (ProDiMES). ProDiMES is a standard benchmarking problem and a set of evaluation metrics to enable the comparison of candidate aircraft engine gas path diagnostic methods. This Matlab (The Mathworks, Inc.) based software tool enables users to independently develop and evaluate diagnostic methods. Additionally, a set of blind test case data is also distributed as part of the software. This will enable the side-by-side comparison of diagnostic approaches developed by multiple users. The Users Guide describes the various components of ProDiMES, and provides instructions for the installation and operation of the tool.

Simon, Donald L.↗

Rare-earth element fractionation in uranium ore and its U(VI) alteration minerals

We developed a cation exchange chromatography method employing sulfonated polysterene cation resin (DOWEX AG50-X8) in order to separate rare-earth elements (REEs) from uranium-rich materials. The chemical separation scheme is designed to reduce matrix effects and consequently yield enhanced ionization efficiencies for concentration determinations of REEs without significant fractionation using solution mode-inductively coupled plasma mass spectrometry (ICP-MS) analysis. This method was then applied to determine REE abundances in four uraninite (ideally UO 2 ) samples and their associated U(VI) alteration minerals. In three of the samples analyzed, the concentration of REEs for primary uraninite are higher than those for their corresponding secondary uranium alteration phases. The results for U(VI) alteration minerals of two samples indicate enrichment of the light REEs (LREEs) over the heavy REEs (HREEs). This differential mobilization is attributed to differences in the mineralogical composition of the U(VI) alteration. There is a lack of fractionation of the LREEs in the uraninite alteration rind that is composed of U(VI) minerals containing Ca 2+ as the interlayer cation (uranophane and bequerelite); contrarily, U(VI) alteration minerals containing K + and Pb 2+ as interlayer cations (fourmarierite, dumontite) indicate fractionation (enrichment) of the LREEs. Our results have implications for nuclear forensic analyses since a comparison is reported between the REE abundances for the CUP-2 (processed uranium ore) certified reference material and previously determined values for uranium ore concentrate (UOC) produced from the same U deposit (Blind River/Elliott Lake, Canada). UOCs represent the most common form of interdicted nuclear material and consequently is material frequently targeted for forensic analysis. The comparison reveals similar chondrite normalized REE signatures but variable absolute abundances. Based on the results reported here, the latter may be attributed to the differing REE abundances between primary ore and associated alteration phases, and/or is related to varying fabrication processes adopted during production of UOC.

58 GEOSCIENCES↗

STRONG FIELD-TO-FIELD VARIATION OF Ly{alpha} NEBULAE POPULATIONS AT z {approx_equal} 2.3

Understanding the nature of distant Ly{alpha} nebulae, aka 'blobs', and connecting them to their present-day descendants requires constraining their number density, clustering, and large-scale environment. To measure these basic quantities, we conduct a deep narrowband imaging survey in four different fields, Chandra Deep Field South (CDFS), Chandra Deep Field North (CDFN), and two COSMOS subfields, for a total survey area of 1.2 deg{sup 2}. We discover 25 blobs at z = 2.3 with Ly{alpha} luminosities of L{sub Ly{alpha}=} (0.7-8) x 10{sup 43} erg s{sup -1} and isophotal areas of A{sub iso} = 10-60 {open_square}arcsec. The transition from compact Ly{alpha} emitters (LAEs; A{sub iso} {approx} a few {open_square}arcsec ) to extended Ly{alpha} blobs (A {sub iso} > 10 {open_square}arcsec) is continuous, suggesting a single family perhaps governed by similar emission mechanisms. Surprisingly, most blobs (16/25) are in one survey field, the CDFS. The six brightest, largest blobs with L {sub Ly{alpha} {approx}}> 1.5x10{sup 43} erg s{sup -1} and A{sub iso} > 16 {open_square}arcsec lie only in the CDFS. These large, bright blobs have a field-to-field variance of {sigma} {sub v} {approx}> 1.5 (150%) about their number density n {approx}1.0{sup +1.8}{sub -0.6}x 10{sup -5} Mpc{sup -3}. This variance is large, significantly higher than that of unresolved LAEs ({sigma} {sub v} {approx} 0.3 or 30%), and can adversely affect comparisons of blob number densities and luminosity functions (LFs) among different surveys. Our deep, blind survey allows us to construct a reliable blob LF. We compare the statistics of our blobs with dark matter halos in a 1 h {sup -1} Gpc cosmological N-body simulation. At z = 2.3, n implies that each bright, large blob could occupy a halo of M{sub halo} {approx}>10{sup 13} M{sub sun} if most halos have detectable blobs. The predicted variance in n is consistent with that observed and corresponds to a bias of {approx}7. Blob halos lie at the high end of the halo mass distribution at z = 2.3 and are likely to evolve into the {approx}10{sup 14} M{sub sun} halos typical of galaxy clusters today. On larger scales of {approx}10 comoving Mpc, blobs cluster where compact LAEs cluster, indicating that blobs lie in coherent, highly overdense structures.

79 ASTRONOMY AND ASTROPHYSICS↗

The seventh blind test of crystal structure prediction: structure generation methods

A seventh blind test of crystal structure prediction was organized by the Cambridge Crystallographic Data Centre featuring seven target systems of varying complexity: a silicon and iodine-containing molecule, a copper coordination complex, a near-rigid molecule, a cocrystal, a polymorphic small agrochemical, a highly flexible polymorphic drug candidate, and a polymorphic morpholine salt. In this first of two parts focusing on structure generation methods, many crystal structure prediction (CSP) methods performed well for the small but flexible agrochemical compound, successfully reproducing the experimentally observed crystal structures, while few groups were successful for the systems of higher complexity. A powder X-ray diffraction (PXRD) assisted exercise demonstrated the use of CSP in successfully determining a crystal structure from a low-quality PXRD pattern. The use of CSP in the prediction of likely cocrystal stoichiometry was also explored, demonstrating multiple possible approaches. Crystallographic disorder emerged as an important theme throughout the test as both a challenge for analysis and a major achievement where two groups blindly predicted the existence of disorder for the first time. Additionally, large-scale comparisons of the sets of predicted crystal structures also showed that some methods yield sets that largely contain the same crystal structures.

Chemistry↗

Experimental validation and model development for thermal transmittances of porous window screens and horizontal louvred blind systems

Virtually every home in the US has some form of shades, blinds, drapes, or other window attachment, but few have been designed for energy savings. In order to provide a common basis of comparison for thermal performance it is important to have validated simulation tools. This study outlines a review and validation of the ISO 15099 centre-of-glass thermal transmittance correlations for naturally ventilated cavities through measurement and detailed simulations. The focus is on the impacts of room-side ventilated cavities, such as those found with solar screens and horizontal louvred blinds. The thermal transmittance of these systems is measured experimentally, simulated using computational fluid dynamics analysis, and simulated utilizing simplified correlations from ISO 15099. Finally, correlation coefficients are proposed for the ISO 15099 algorithm that reduces the mean error between measured and simulated heat flux for typical solar screens from 16% to 3.5% and from 13% to 1% for horizontal blinds.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

GREEN BANK TELESCOPE ZPECTROMETER CO(1-0) OBSERVATIONS OF THE STRONGLY LENSED SUBMILLIMETER GALAXIES FROM THE HERSCHEL ATLAS

The Herschel Astrophysical Terahertz Large Area Survey (H-ATLAS) has uncovered a population of strongly lensed submillimeter galaxies (SMGs). The Zpectrometer instrument on the Green Bank Telescope (GBT) was used to measure the redshifts and constrain the masses of the cold molecular gas reservoirs for two candidate high-redshift lensed sources. We derive CO(1-0) redshifts of z = 3.042 {+-} 0.001 and z = 2.625 {+-} 0.001, and measure molecular gas masses of (1-3) x10{sup 10} M{sub sun}, corrected for lens amplification and assuming a conversion factor of {alpha} = 0.8 M{sub sun}( K km s{sup -1} pc{sup 2}){sup -1}. We find typical L(IR)/L'(CO) ratios of 120 {+-} 40 and 140 {+-} 50 L{sub sun}( K km s{sup -1} pc{sup 2}){sup -1}, which are consistent with those found for local ultraluminous infrared galaxies (ULIRGs) and other high-redshift SMGs. From analysis of published data, we find no evidence for enhanced L(IR)/L'(CO(1-0)) ratios for the SMG population in comparison to local ULIRGs. The GBT results highlight the power of using the CO lines to derive blind redshifts, which is challenging for the SMGs at optical wavelengths given their high obscuration.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimization of a Lethal, Combat-Relevant Model of Sterile Inflammation in Mice for Drug Candidate Screening

ABSTRACT Introduction Extensive trauma, commonly seen in wounded military Service Members, often leads to a severe sterile inflammation termed systemic inflammatory response syndrome (SIRS), which can progress to multiple organ dysfunction syndrome (MODS) and death. MODS is a serious threat to wounded Service Members, historically causing 10% of all deaths in trauma admissions at a forward deployed combat hospital. The importance of this problem will be exacerbated in large-scale combat operations, in which evacuation will be delayed and care of complex injuries at lower echelons of care may be prolonged. The main goal of this study was to optimize an existing mouse model of lethal SIRS/MODS as a therapeutic screening platform for the evaluation of immunomodulatory drugs. Materials and Methods Male C57BL/6 mice were euthanized, and the bones and muscles were collected and blended into a paste termed tissue–bone matrix (TBX). The TBX at 12.5%–20% relative to body weight of each recipient mouse was implanted into subcutaneous pouches created on the dorsum of anesthetized animals. Mice were observed for clinical scores for up to 48 hours postimplantation and euthanized at the preset point of moribundity. To test effects of anesthetics on TBX-induced mortality, animals received isoflurane or ketamine/xylazine (K/X). In a separate set of studies, mice received TBX followed by intraperitoneal injection with 20 mg/kg or 40 mg/kg Eritoran or a placebo carrier. All Eritoran studies were performed in a blinded fashion. Results We observed that K/X anesthesia significantly increased the lethality of the implanted TBX in comparison to inhaled anesthetics. Although all the mice anesthetized with isoflurane and implanted with 12.5% TBX survived for 24 hours, 60% of mice anesthetized with K/X were moribund by 24 hours postimplantation. To mimic more closely the timing of lethal SIRS/MODS following polytrauma in human patients, we extended observation to 48 hours. We performed TBX dose–response studies and found that as low as 15%, 17.5%, and 20% TBX caused moribundity/mortality in 50%, 80%, and 100% mice, respectively, over a 48-hour time period. With 17.5% TBX, we tested if moribundity/mortality could be rescued by anti-inflammatory drug Eritoran, a toll-like receptor 4 antagonist. Neither 20 mg/kg nor 40 mg/kg doses of Eritoran were found to be effective in this model. Conclusions We optimized a TBX mouse model of SIRS/MODS for the purpose of evaluating novel therapeutic interventions to prevent trauma-related pathophysiologies in wounded Service Members. Negative effects of K/X on lethality of TBX should be further evaluated, particularly in the light of widespread use of ketamine in treatment of pain. By mimicking muscle crush, bone fracture, and necrosis, the TBX model has pleiotropic effects on physiology and immunology that make it uniquely valuable as a screening tool for the evaluation of novel therapeutics against trauma-induced SIRS/MODS.

General & Internal Medicine↗

A new method for detecting velocity shifts and distortions between optical spectra

Recent quasar spectroscopy from the Very Large Telescope (VLT) and Keck suggests that fundamental constants may not actually be constant. To better confirm or refute this result, systematic errors between telescopes must be minimized. We present a new method to directly compare spectra of the same object and measure any velocity shifts between them. This method allows for the discovery of wavelength-dependent velocity shifts between spectra, i.e., velocity distortions, that could produce spurious detections of cosmological variations in fundamental constants. This 'direct comparison' method has several advantages over alternative techniques: it is model-independent (cf. line-fitting approaches), blind, in that spectral features do not need to be identified beforehand, and it produces meaningful uncertainty estimates for the velocity shift measurements. In particular, we demonstrate that, when comparing echelle-resolution spectra with unresolved absorption features, the uncertainty estimates are reliable for signal-to-noise ratios ≳7 per pixel. We apply this method to spectra of quasar J2123–0050 observed with Keck and the VLT and find no significant distortions over long wavelength ranges (∼1050 Å) greater than ≈180 m s{sup –1}. We also find no evidence for systematic velocity distortions within echelle orders greater than 500 m s{sup –1}. Moreover, previous constraints on cosmological variations in the proton-electron mass ratio should not have been affected by velocity distortions in these spectra by more than 4.0 ± 4.2 parts per million. This technique may also find application in measuring stellar radial velocities in search of extra-solar planets and attempts to directly observe the expansion history of the universe using quasar absorption spectra.

79 ASTRONOMY AND ASTROPHYSICS↗

Broadband, 920-nm mirror thin film damage competition

This year’s competition proposed to survey the state-of-the-art broadband, near-IR multilayer dielectric (MLD) mirrors designed for ultra-short, pulsed laser applications. The requirements for the coatings were a minimum reflection of 99.5% at 45-degree incidence angle for S-polarization from 830 nm to 1010 nm and group delay dispersion (GDD) < ± 50 fs 2 . The participants in this effort selected the coating materials, coating design, and deposition method. Samples were damage tested at a single testing facility to enable direct comparison among the participants using a 25 ± 5 fs OPCPA laser system operating at 5 Hz. A double blind test assured sample and submitter anonymity. The damage performance results, sample rankings, details of the deposition processes, coating materials and substrate cleaning methods are shared here. We found that multilayer coatings using tantala and/or hafnia as high index materials were top performers within several coating deposition groups. Specifically, dense coatings by ion-beam sputtering (IBS), magnetron sputtering (MS), and electron-beam ion assisted deposition (e-beam IAD) exhibited highest damage initiation onset (LIDT) while e-beam coatings were low performers. In addition, damage growth onset (LDGT) was also examined and the results are reported here for all samples as this performance metric plays an important role in establishing the safe operational conditions for larger aperture, ultrashort pulsed lasers. As a result, not all coating samples in the survey met the GDD requirements stated above and associated measurements are discussed in the context of the present and past competitions focused on similar broadband, near-IR MLD coatings.

42 ENGINEERING↗

SWIFT Code Assessment for Two Similar Transonic Compressors

One goal of the NASA Fundamental Aeronautics Program is the assessment of computational fluid dynamic (CFD) codes used for the design and analysis of many aerospace systems. This paper describes the assessment of the SWIFT turbomachinery analysis code for two similar transonic compressors, NASA rotor 37 and stage 35. The two rotors have identical blade profiles on the front, transonic half of the blade but rotor 37 has more camber aft of the shock. Thus the two rotors have the same shock structure and choking flow but rotor 37 produces a higher pressure ratio. The two compressors and experimental data are described here briefly. Rotor 37 was also used for test cases organized by ASME, IGTI, and AGARD in 1994-1998. Most of the participating codes over predicted pressure and temperature ratios, and failed to predict certain features of the downstream flowfield. Since then the AUSM+ upwind scheme and the k- turbulence model have been added to SWIFT. In this work the new capabilities were assessed for the two compressors. Comparisons were made with overall performance maps and spanwise profiles of several aerodynamic parameters. The results for rotor 37 were in much better agreement with the experimental data than the original blind test case results although there were still some discrepancies. The results for stage 35 were in very good agreement with the data. The results for rotor 37 were very sensitive to turbulence model parameters but the results for stage 35 were not. Comparison of the rotor solutions showed that the main difference between the two rotors was not blade camber as expected, but shock/boundary layer interaction on the casing.

Chima, Rodrick V.↗

H I-SELECTED GALAXIES AS A PROBE OF QUASAR ABSORPTION SYSTEMS

We investigate the properties of H I-rich galaxies detected in blind radio surveys within the hierarchical structure formation scenario using a semianalytic model of galaxy formation. By drawing a detailed comparison between the properties of H I-selected galaxies and H I absorption systems, we argue a link between the local galaxy population and quasar absorption systems, particularly for damped Lyalpha absorption (DLA) systems and sub-DLA systems. First, we evaluate how many H I-selected galaxies exhibit H I column densities as high as those of DLA systems. We find that H I-selected galaxies with H I masses M{sub H{sub I}} {approx}> 10{sup 8} M{sub sun} have gaseous disks that produce H I column densities comparable to those of DLA systems. We conclude that DLA galaxies where the H I column densities are as high as those of DLA systems, contribute significantly to the population of H I-selected galaxies at M{sub H{sub I}} {approx}> 10{sup 8} M{sub sun}. Second, we find that star formation rates (SFRs) correlate tightly with H I masses (M{sub H{sub I}}) rather than B- (and J-) band luminosities: SFR {proportional_to} M {sup alpha}{sub H{sub I}}, alpha = 1.25-1.40 for 10{sup 6} <= M{sub H{sub I}}/M{sub sun} <= 10{sup 11}. In the low-mass range M{sub H{sub I}} {approx}< 10{sup 8} M{sub sun}, sub-DLA galaxies replace DLA galaxies as the dominant population. The number fraction of sub-DLA galaxies relative to galaxies reaches 40%-60% for M{sub H{sub I}} {approx} 10{sup 8} M{sub sun} and 30%-80% for M{sub H{sub I}} {approx} 10{sup 7} M{sub sun}. The H I-selected galaxies at M{sub H{sub I}} {approx} 10{sup 7} M{sub sun} are a strong probe of sub-DLA systems that place stringent constraints on galaxy formation and evolution.

79 ASTRONOMY AND ASTROPHYSICS↗

A Comparison of Cocrystal Structure Solutions from Powder and Single Crystal Techniques

We demonstrate the effectiveness and accuracy of high resolution powder diffraction for determination of cocrystal structures through a double-blind study. Structures of 10 cocrystals of varying complexity were determined independently using single crystal and powder techniques. The two methodologies give identical molecular packing and hydrogen bond topology, and an rms difference in covalent bond lengths of 0.035 {angstrom}. Powder techniques are clearly sufficient to establish a complete characterization of cocrystal geometry.

08 HYDROGEN↗

AIS-based characterization of navigation conflicts along the US Atlantic Coast prior to development of wind energy

This study characterizes navigation conflicts in a region with a large traffic volume along the US Atlantic Coast, utilizing Automated Identification System (AIS) data for 2010. The region includes areas proposed for wind energy development. The characterization could be useful in evaluating the effect of offshore wind areas on navigation conflicts. The study processes the AIS data to provide pairwise comparisons of vessel interactions (encounters and near-misses) as they occurred. Using the vessel encounter data, analyses are made using a ‘blind’ vessel assumption to evaluate the potential for both near-misses and collisions. Then statistical analyses are made to estimate the point values and uncertainty for each type of encounter (crossing, head-on, overtaking). Examination of the frequency/number of collisions from actual observations is made. The examination of actual near-misses, potential near-misses, and potential collisions provides comparable results in the number of near-misses and collisions. The potential near-miss analyses include an examination of the timing of responses made by vessels to prevent near-misses. This informed the statistical analysis but may also have utility in the simulation of navigation conflicts.

99 GENERAL AND MISCELLANEOUS↗